The IEC61508 Inspection and QA Engineer s hymn sheet

Similar documents
The IEC61508 Project Manager's & Project Engineer's hymn sheet

The IEC61508 Operators' hymn sheet

Understanding safety life cycles

Implementing IEC Standards for Safety Instrumented Systems

SIL explained. Understanding the use of valve actuators in SIL rated safety instrumented systems ACTUATION

Proof Testing A key performance indicator for designers and end users of Safety Instrumented Systems

Understanding the How, Why, and What of a Safety Integrity Level (SIL)

Every things under control High-Integrity Pressure Protection System (HIPPS)

FUNCTIONAL SAFETY: SIL DETERMINATION AND BEYOND A CASE STUDY FROM A CHEMICAL MANUFACTURING SITE

innova-ve entrepreneurial global 1

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Achieving Compliance in Hardware Fault Tolerance

Transmitter mod. TR-A/V. SIL Safety Report

Solenoid Valves used in Safety Instrumented Systems

Ultima. X Series Gas Monitor

EVT * -Pro Electronic Valve Tester

High Integrity Pressure Protection Systems HIPPS

Procedure: Pressure equipment safety

Section 1: Multiple Choice Explained EXAMPLE

VALIDATE LOPA ASSUMPTIONS WITH DATA FROM YOUR OWN PROCESS

DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508

New Thinking in Control Reliability

Partial Stroke Testing. A.F.M. Prins

W E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard.

Functional safety. Functional safety of Programmable systems, devices & components: Requirements from global & national standards

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

Safety manual for Fisher GX Control Valve and Actuator

YT-300 / 305 / 310 / 315 / 320 / 325 Series

Failure Modes, Effects and Diagnostic Analysis

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

Section 1: Multiple Choice

Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants

Valve Communication Solutions. Safety instrumented systems

Jamesbury Pneumatic Rack and Pinion Actuator

DeZURIK. KSV Knife Gate Valve. Safety Manual

Failure Modes, Effects and Diagnostic Analysis

SUP 15 Health & Safety Management Pressure Systems. Unified procedures for use within NHS Scotland

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No.

Solenoid Valves For Gas Service FP02G & FP05G

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

PROCESS SAFETY FUNDAMENTALS ENABLING FLAWLESS FIELD EXECUTION

I have to say that I had no idea about compressors. That means it s easy for everybody.

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

Module No. # 01 Lecture No. # 6.2 HAZOP (continued)

Reliability of Safety-Critical Systems Chapter 4. Testing and Maintenance

Bespoke Hydraulic Manifold Assembly

CONTROL OF HAZARDOUS ENERGY

EMERGENCY SHUT-DOWN RELIABILITY ADVANTAGE

New AQF Filter Polymer Filtration System

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

AWHEM RECOMMENDED PRACTICE

Proposed Abstract for the 2011 Texas A&M Instrumentation Symposium for the Process Industries

Impact on People. A minor injury with no permanent health damage

Amusement Device Safety Council. Safety of Amusement Devices: Pre-use inspection

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Safety Manual VEGAVIB series 60

PROCESS AUTOMATION SIL. Manual Safety Integrity Level. Edition 2005 IEC 61508/61511

Safety Manual VEGAVIB series 60

Neles trunnion mounted ball valve Series D Rev. 2. Safety Manual

EM385 Construction Safety and Health Certification Course Section 12 Control of Hazardous Energy

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

Grantek Systems Integration

Gas Safety Management Policy

The Safety Case. The safety case

Significant Change to Dairy Heat Treatment Equipment and Systems

Hydraulic (Subsea) Shuttle Valves

Failure Modes, Effects and Diagnostic Analysis

Accelerometer mod. TA18-S. SIL Safety Report

SPR - Pneumatic Spool Valve

BROCHURE. Pressure relief A proven approach

C. Mokkapati 1 A PRACTICAL RISK AND SAFETY ASSESSMENT METHODOLOGY FOR SAFETY- CRITICAL SYSTEMS

A large Layer of Protection Analysis for a Gas terminal scenarios/ cause consequence pairs

The Risk of LOPA and SIL Classification in the process industry

Safety Manual OPTISWITCH series relay (DPDT)

Rosemount 2130 Level Switch

SEMS II: BSEE should focus on eliminating human error

ESSENTIAL SAFETY RESOURCES

IGEM/SR/15 Edition 5 Communication 1746 Integrity of safety-related systems in the gas industry

QUESTIONS and ANSWERS WHY TEST KONGSBERGS

HEIGHT SAFETY IT S EVERYONE S BUSINESS

A study on the relation between safety analysis process and system engineering process of train control system

White Paper. Electrical control valve actuators on oil and gas production separators

IST-203 Online DCS Migration Tool. Product presentation

Workshop Functional Safety

GUIDE TO RUNNING A BIKE SHARE. h o w t o p l a n a n d o p e r a t e a s u c c e s s f u l b i k e s h a r e p r o g r a m

THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS

Valve actuation at the world s largest flow metering calibration facility

4-sight Consulting. IEC case study.doc

Commissioning and safety manual

Transcription:

The IEC61508 Inspection and QA Engineer s hymn sheet A few key points for those inspectors and QA engineers involved with a project using the IEC61508 group of standards by the 61508 Association SAFETY INSTRUMENTED SYSTEMS are too important to leave to chance! DISCLAIMER: Whilst every effort has been made to ensure the accuracy of the information contained in this document neither The 61508 Association nor its members will assume any liability for any use made thereof.

Are you involved with functional safety? Are you involved with SIL? If you are involved with SIL then you are involved with Functional Safety and you should be using one of the IEC61508 group of standards.

fact number 1 The IEC61508 group of standards require that you have in place Functional Safety Management supporting all activities, claims and data. Safety is depending on that one SIL rated loop so EVERYONE involved has to be demonstrably competent... IEC61508 Part 1 Clause 6... Matching requirements appear in the sector specific guidance standards (For example: IEC61511 Part 1 Clause 5)... Regulators are increasingly demanding that safety management is properly covered (See the HSE guidance Managing Competence for Safety Related Systems July 2007) http://www.hse.gov.uk/consult/condocs/competence.htm

fact number 2 The IEC61508 group of standards require that your suppliers and sub-contractors demonstrate Functional Safety Management... so certification of Functional Safety Management, or other appropriate proof, is the FIRST thing that inspection and QA should look for.... interestingly, certificates for components (such as transmitters) are NOT required under the standard (but they might be appropriate for your project).... so don't make the mistake of asking for certificates for equipment (the bit that isn't demanded) when you've forgotten to ask for proof of Functional Safety Management (the bit that IS demanded).

fact number 3 The IEC61508 group of standards require that your suppliers and sub-contractors demonstrate Functional Safety Management... IEC61508 Part 1 Clause 6... matching requirements appear in the sector specific guidance standards (For example: IEC61511 Part 1 Clause 5)... Regulators are increasingly demanding that safety management is properly covered (See the HSE guidance - Managing Competence for Safety Related Systems July 2007) http://www.hse.gov.uk/consult/condocs/competence.htm

fact number 4 The presence of a certified expert is NOT proof of Functional Safety Management... The use of a functional safety expert may sometimes be appropriate as a decision that comes out of a contractor's or supplier's Functional Safety Management, but it is NOT a substitute for a Functional Safety Management system... Functional Safety Management covers EVERBODY involved... not just the expert... not just the technician... it involves everybody involved in the safety system (including you, the Inspection and QA engineer, the Project Manager, the Engineering Manager...everyone!)

fact number 5 A SIL 3 safety loop means that without that one loop functioning correctly the risk of fatality* is more than 1000 times the wrong side of tolerable. A SIL 2 safety loop means that without that one loop functioning the risk of fatality* is more than 100 times the wrong side of tolerable. A SIL 1 safety loop means that without that one loop functioning the risk of fatality* is more than 10 times the wrong side of tolerable. We suggest that you don't even think about SIL 4! *That is if the SIL loop has been provided for protection of people. The SIL loop may have been provided for environmental or asset protection.

fact number 5 continued... SAFETY INSTRUMENTED SYSTEMS are too important to leave to chance! Maintenance and proof testing of safety instrumented systems are not just important they are ESSENTIAL The proof testing is to reassure EVERYONE that the loop works correctly and will save lives* Audit your maintenance departments records of testing and maintenance make sure they are up to date and that all failures particularly dangerous failures are fully documented and the loop designer informed so that continuing compliance (or not) with the required SIL is confirmed. Note that if the recorded dangerous failures are worse than predicted then it is possible that the loop will no longer achieve the required risk reduction and consequently some urgent redesign will be required to maintain safety. *That is if the SIL loop has been provided for protection of people. The SIL loop may have been provided for environmental or asset protection.

fact number 6 You can't replace one certified component with another certified component from a different manufacturer even if they are both certified to the same level You can't even replace a component with one of a different version or model The reliability required to perform correctly in the safety loop is a combination of factors that include the maintenance and proof testing of the component. The component from a different manufacturer will be expected to achieve reliabilities in the same range but with DIFFERENT maintenance and proof-testing requirements. If you substitute a component with one from a different manufacturer then you are affecting the maintenance and proof-testing requirements for the entire loop and the whole loop design must be referred back to the designer.

fact number 7 IEC 61508 group of standards does NOT require certification for components. It does require proof of reliability and suitability for the application A certificate alone is NOT proof of reliability and suitability for the application... The report behind the certificate gives the designer of the safety loop the reliability data needed to design the loop... The report needs to show how the data was generated... The report needs to show the limits of applicability for the data... The report needs to show restrictions and conditions of use

fact number 8 The report that gives the reliability data for the component is the ESSENTIAL information that the designer needs to design the safety loop The safety loop designer CANNOT design the safety loop without the reliability data... A certificate without the report giving the data is useless to the loop designer... A certificate without the reliability data and the basis of the assessment is a waste of paper... If your safety loop designer doesn t have the report then they can't use the component When auditing make sure the right information is available!

fact number 8 continued... The report that gives the reliability data for the component is the ESSENTIAL information that the designer needs to design the safety loop The safety loop designer CANNOT design the safety loop without the reliability data... The report should show the assumptions made and the basis of the reliability assessment as well as the scope (it is not unusual to find that the component's reliability assessment only covers electronic hardware and not the process interface!)... The report should show the techniques of assessment and not just a bland statement that it was assessed. The techniques used are a real part of what demonstrates that the reliability evidence is appropriate for the application

fact number 9 A certified claim that a component is SIL 2 (or any other SIL number) does NOT mean that it is suitable for use in your SIL 2 safety loop.... The SIL number does not apply to the components in isolation... The SIL rating applies to the whole loop and NOT just the individual components in the loop... The loop architecture also plays a part in the reliability required of an individual component... It is NOT at all unusual to find that a collection of SIL 3 parts put together in a loop only achieve SIL 1 or SIL 2... and the SIL rating is a safety LOOP value not a component value

fact number 10 Every component in the loop needs to provide sufficient reliability so that the loop achieves the SIL rated integrity... This means that the valve, pump or end device that takes the ultimate action to maintain safety is INCLUDED.... It is NOT enough to simply use a SIL certified PLC and connect all the loops into that.... It is NOT enough to get a SIL certified PLC and a certified transmitter and ignore the other parts of the safety loop

fact number 11 The part of a safety instrumented system that is most likely to fail is... the people (see fact numbers 1, 2 & 3) Almost everyone will choose a certified PLC usually the MOST reliable part of the loop even without a certificate A lot of people will ask for a certified transmitter less reliable than the PLC but usually robust Some people will ask for a certificate with the valve... an unreliable part of the loop Too many people fail to ask for the safety report... the bit that is ESSENTIAL for the design (they went away surprisingly happy with a certificate!) Hardly anyone asks about the people... the LEAST reliable part (the part covered by functional safety management) You need to consider the whole list as equal in importance

fact number 12 Proven in use or Prior use claims require substantial evidence and cannot easily be used... ONLY the end user can offer a Proven in use or Prior use claim as evidence of suitability in a safety instrumented system (and they need substantial valid evidence of previous use in the same application complete with failure records and safety management amongst other requirements)... A salesperson or supplier cannot offer Proven in use or prior use as evidence of a SIL rating claim As Auditor ensure that your engineers are not required to engineer safety loops with invalid equipment... See the 61508 Association statement on Proven in use and Prior use claims

Your guide for inspection and QA Ask suppliers for evidence of Functional Safety Management (meeting the requirements of IEC61508 part 1 clause 6 or its matching requirements under the sector standards) Don't accept the presence of an expert as proof of Functional Safety Management (there are no certified experts mentioned in the standard) Don't approve components without the report (or equivalent) giving the evidence of reliability and all the associated conditions even if it does have a certificate Don't approve product reliabilities based upon factory return data unless you have proof that the application is the same (not just similar) The SIL applies to the whole loop NOT just to the components Make sure that all parties are involved in safety don t forget the operations, maintenance and service departments!