Instructions for use Compressed air injector with water trap

Similar documents
Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

BY GREGGERSEN CATA LOG

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Oxygen Dialflow Meter. Instructions for Use

80 Litre Suction Oil Drainer

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

OPERATION MANUAL obl1 OPERATION MANUAL

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1

SILENTAIRE TECHNOLOGY

Instructions for Use Switch Unit AGS 80 D Variant A

Pressure Reducing Valve DMV 750

MODEL CALIBRATION GAS DELIVERY SYSTEM

Attention: This operator's manual should be read carefully before using the pistol! ENGLISH

User Instruction Manual

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Siphon vessel / Priming aid

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

G7S Hand Pump Owner s Manual

Operating instructions - Translation of the original -

Instrument Description and Operating Instructions OXYMAT 2. Its own oxygen source

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Budget Range Operators Handbook

A18W35_MASE 130_F_EN MANUAL

Corning Step-R. Repeating Pipettor. Instruction Manual

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

SILENTAIRE TECHNOLOGY

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

Oxygen Dialflow Meter. Instructions for Use

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

PARTS & SERVICE. regulator (new) for NGW/ GBW applications. Rev. 02/2018 Id.No. DOK50026

BGI, INC. WALTHAM, MA 02451

APC Pressure Reducer with Sensor

The number of test stands can be adapted to the special requirements.

Attention: This operator s manual should be read carefully before using the air rifle. ENGLISH

User's Manual. MixRite TF 10. Edition 05.08

BS ml Bottle Sampling Unit

Pressure relief valve

CSA Sample Draw Aspirator Adapter Operator s Manual

OXYGEN THERAPY FLOWMETERS, REUSABLE AND SINGLE-PATIENT HUMIDIFIERS, PRESSURE REGULATORS, FLOW SELECTORS

USER MANUAL SAVE THESE INSTRUCTIONS. Manuals available on our Website;

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

CONTROLLERS FOR COMPRESSED AIR AND VACUUM MEDAP-FINA SUCTION

A17W23_MASE_MUS_EN MANUAL

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar

DOUBLE MASK REV: /BS

OPERATING INSTRUCTIONS

HOSPITAL STRUCTURAL PRODUCTS 12. MEDICAL GAS SYSTEMS LUMINAIRES AND OTHER EQUIPMENTS WALL CORNER PROTECTION SYSTEMS A. B. C.

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

1. CONDITIONS FOR USE 2. SAFETY

EcoCell Vertical Electrophoresis Unit

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

TactAir PCP Fill Kit/Adapter. Operation Manual

AIR STAPLER MODEL: CSG1C Part No

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Operation Manual. PEGAS NovoTap, PEGAS NovoTap+

Full-Vacuum Chlorinator C 2212 MB / 1

TURBO SET 1000 E D $'9 5(9

Stainless Steel 142 mm Filter Holder YY

Installation and Maintenance Instruction Manual

OPERATING MANUAL EASY-LOAD PUMP HEADS

FIREFIGHTING EQUIPMENT

MEDAP-MOBILE GAS SUPPLY

OPERATING MANUAL EASY-LOAD PUMP HEADS

STEYR evo 10 E STEYR evo 10 E Compact

A N F G J I C D D L A B C D E F

Installation and Maintenance Instruction Manual

Gemini Assisted Bath Product Care & User Operating Instructions

OWNER S MANUAL SUCTION GUN SG-300

TJF-Q180V Cleaning and Disinfection Checklist

You have decided to buy an LP 10 E by STEYR SPORTWAFFEN the new dimension of match air pistols!

CPR MEDICAL DEVICES INC. OPERATING MANUAL

Airtester HP for compressed air according to EN 12021

MEDAP-FLOWMETERS FOR OXYGEN AND COMPRESSED AIR

Pressure relief valve

Operating Instructions Part No

GENO -Flushing Compressor Product Data Sheet F 02

TJF-Q180V Cleaning and Disinfection Checklist

Operating manual for Material pressure tanks Vol./1 and Vol./2

Micro Dial-Flowmeter. Instructions for Use

PRAHER PLC-MP AQUASTAR MANAUL 2009

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Armatures for analytical probes

Pressure maintenance valve SDV-P / SDV-P-E

Tourniquet Systems Pressure Infusion

444C DUAL PERFORMANCE VALUE PACK

Med Aire Alternating Pressure Pump and Pad System

Operating Instructions Part No

Operating Instructions VETTER Industrial Lifting Bags 8 bar - Type IKV

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Transcription:

Instructions for use Compressed air injector with water trap

Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for Cleaning and Care 3.1 Disassembling 3.2 Disinfection and Cleaning 3.2.1 Manual Disinfection and Cleaning 3.2.2 Mechanical Disinfection and Cleaning 3.3 Sterilisation 4. Technical Data 5. Spare Parts 6. Customer Service / Warranty / Maintenance 7. Manufacturer s Data Seite 2 von 16

INTRODUCTION These instructions for use are meant to support you to operate the outlet systems for compressed air. In addition, you will find a description of the various options available to combine the products with different systems. If any failures or questions should come up during service please do not hesitate to contact our customer service department for help. 1. DESCRIPTION OF FUNCTIONS and MODELS The compressed air injector with water trap combined with a collecting device has been designed for secretion removal by suction over a longer period of time. In addition, this system allows for the very precise and consistent adjustment of small vacuums and the competent, professional application of a secretion removal system by suction. The vacuum required for this purpose is generated by means of compressed air from an injector. The compressed air available from the central supply system streams through an injector and then outside through a sound absorber. When the compressed air streams through the injector nozzle an undertow is generated which comes into effect at the end of the suction hose. Depending on the setting of the infinitely variable regulating valve, this suction is capable of generating a vacuum between 0 and -0.8 bar. This vacuum is limited by the immersion depth of the immersion tube in the water trap. Seite 3 von 16

The maximum immersion depth is 40 cm. This corresponds to a maximum vacuum of 0.04 bar. - water column of 1 cm = 0.001 bar = 1 mbar When the resistance of the secretion rises the vacuum increases as well and the atmospheric pressure of the surrounding presses the water level in the immersion tube more and more under the water level in the bottle. The difference in height (h) of the two water levels in cm corresponds to the currently generated negative pressure in mbar. When the water level in the immersion tube reaches the lowest end (h max.) air escapes through the immersion tube and goes up in the form of air bubbles. This prevents the vacuum from increasing more and it is limited. Due to the fact that the position of the immersion tube can be modified in its height, different limiting positions may be chosen, i.e. it is possible to infinitely adjust different vacuums. Illustration 1 System plan Seite 4 von 16

The compressed air injector with water trap is available in the following designs: Injector for direct connection to the compressed air outlet Article No.: 623-0230 The injector comes equipped with a connector standardised for this particular gas. Injector for wall rail with NIST screw joints Article No.: 623-0210 The injector is connected to the medical gas supply by means of a gas-type coded connecting hose. Seite 5 von 16

Accessories required Air connecting hose for compressed air injector with water trap rail ISO 6600117 / Neutral 6600116 Accessories recommended for permanent drainage injector direct and rail Illustr.: Suction set with finger tip and bacteria filter 606-2400 Bacteria filter In order to avoid contamination, the bacteria filter has to be installed between the injector and the secretion-collecting jar. Secretion-collecting jar The secretion which has been sucked off is collected in the secretioncollecting jar which has been equipped with a float ball to prevent it from overflowing. Once the maximum filling height has been reached, this float ball will lock the connection to the compressed air injector. Seite 6 von 16

The following secretion-collecting jars may be connected: Secretion-collecting jar 1.0 l Rail 6600255 Secretion-collecting jar 1.0 l Jar-carrying rack 6600265 Carrying rack for secrectioncollecting jar 1.0 l 6600260 Illustr. Size 2.0 l 6231000 Also available in Size 1.0 l 6231050 Size 3.0 l 6231060 Secretion-collecting jar with bayonet joint The scaling on all secretion-collecting jars is only meant as an approximate value without measuring function. Alternatively, disposable collecting jars may be used. Seite 7 von 16

Immersion tube Clamp screw for immersion tube Hose adapter to secretion-collecting jar Regulating unit Sound absorber with opening for air outlet Collecting jar with scaling for negative pressure Seite 8 von 16

2. PUTTING INTO OPERATION of compressed air injector with water trap Please make sure that all the components connected, i.e. connecting hose, drainage systems, bacteria filter, safety jar, secretion-collecting jar etc., have been properly and firmly adapted. Screw off the collecting jar and fill it with distilled water up to the marking maximum filling height. Before putting into operation, place the immersion tube with the lower edge onto the marking of the vacuum that you require. The position of the immersion tube is fixed by means of the clamp screw. Please make sure that the clamp screw has been fastened properly. The suction power is set by opening the injector. This process will open the vacuum flow and create the undertow required for suction. Turn the regulating unit anti-clockwise until with closed suction connector air bubbles can be seen at the lower end of the immersion tube. This means that the preset negative pressure has been reached. In order to avoid contamination, a bacteria filter has to be installed between the injector and the secretion-collecting jar. Seite 9 von 16

Before putting the system into operation, a function test should be carried out in accordance with the following schedule: Connect the injector with the outlet Fill the collecting jar Set the lower edge of the immersion tube to the marking 5 mbar Open the regulating unit completely (by turning anti-clockwise until reaching the stop) Please make sure that, with an open hose adapter, there are no air bubbles at the end of the immersion tube. Close the regulating unit completely (by turning clockwise until reaching the stop). Please make sure that, with a closed hose adapter, there are no air bubbles at the end of the immersion tube. In the case of a negative test result, please urgently correct the failure yourself or contact our service department. Make sure that the apparatus is not put into operation. Seite 10 von 16

recommended Drainage system Seite 11 von 16

3. INSTRUCTIONS FOR CLEANING AND CARE 3.1 Disassembling For disinfection, cleaning or sterilisation purposes, screw off the bottle and empty it. Attention: Do not autoclave the collecting jar at 134 C. Do not sterilise the sound absorber. 3.2 Disinfection and cleaning 3.2.1 Manual disinfection and cleaning All those parts which get in contact with the patients breathing air have to be disinfected in any case. Put the corresponding application elements into the disinfecting bath; the exposure time will depend on the type of disinfecting agent which is used (see the package insert of the disinfectant). Take the elements out of the disinfecting bath and rinse them with running sterile water. Dry the cleaned elements. Please make sure that there is no humidity left in the apparatus. For those parts which do not get into contact with the patients breathing air wiping disinfection will be sufficient 3.2.2 Mechanical disinfection and cleaning Please make sure that you only use non-aggressive detergents, for example neo disher MA, neo disher FA or similar products. 3.3. Sterilisation Disposable application elements must not be autoclaved (see order data). Seite 12 von 16

4. Technical Data Compressed air injector with water trap Direct Compressed air injector with water trap Rail Article No.: 6230230 6230210 Control range 0 to 40 mbar Suction power appr. 0.8 l / min appr. 0.8 l / min Material Anodized aluminium / Stainless steel Connection Connector acc. to DIN 13260-2 1) NIST screw joints Fastening ---------------------- Exit Hose adapter for silicone hose 6 x 2 H x W x D mm For device-carrying rail 25 x 10 mm 2) 710 x 140 x 140 710 x 140 x 160 Weight 1,400 g 165 g Accessories Article No. Accessories Article No. 1) Various other connections, e.g. BS, AFNOR or AGA available 2) Also available for other rail dimensions See pages 6 to 7 Connecting hose AIR 1.5 mtr DIN 1) - NIST ISO 660-0117 / Neutral 660-0116 Seite 13 von 16

5 Spare Parts Illustration Designation of article Article number Immersion tube with O-ring 043-2330 O-ring for immersion tube 17 x 2 mm 049-3232 Flat gasket for collecting jar 037-1340 Collecting jar complete 019-2510 Clamping ring 043-3211 O-ring for clamping ring 8 x 2 mm 049-3020 No illustration Filter insert water trap 1570130 Seite 14 von 16

6. CUSTOMER SERVICE / WARRANTY / MAINTENANCE The period of warranty for the equipment is 12 months starting from the date of sale in accordance with the following conditions: During the period of warranty, we will eliminate, free of charge, any damage or failures of the equipment caused by verifiable faults in production or in the material, provided that these failures have been reported without delay after detection. Deviating from this, the warranty for engines of any type, compressors, electric switching devices, semiconductor elements, electric displays and measuring equipment is six months. This warranty is not applicable to fragile parts made of glass, for example, or consumable and wearing parts, e.g. filters. In the case of a guarantee, the decision of whether to repair or exchange the equipment will be at our own option. Cases of guarantee will neither extend the period of warranty nor will they represent the start of a new period of warranty. Spare parts which are installed will not be subject to an individual period of warranty. Any damage caused by improper use, faulty operation, mechanical damage or nonobservance of the instructions for use as well as any damage caused by force majeure or any other unusual environmental conditions will not be covered by the warranty. The warranty claim will expire when interventions, changes or repairs of the equipment have been carried out by people who have not been authorised by us to do so or when the equipment has been used with additional accessories or spare parts of strange origin. The faulty equipment has to be sent in its original packaging - to the address mentioned below with carriage and postage paid. Further claims as well as any so-called consequential damage will be excluded as long as liability is not required by law. Equipment may be subject to technical changes without notice! Maintenance The flawless condition and proper functioning of all the silicone seals in the equipment have to be checked once a year and to be replaced if necessary. Also once a year, the system has to be checked for damage and improper functioning. Seite 15 von 16

7 Manufacturer s Data Manufacturer: Heyer Aerotech GmbH Nieverner Straße 30 D - 56132 Nievern Tel.: +49 (0)2603/2004 Fax: +49 (0)2603/4020 E-Mail: office@heyer-aerotech.de Homepage: www.heyer-aerotech.de Sales office: Heyer Aerotech GmbH Nieverner Straße 30 D - 56132 Nievern Tel.: +49 (0)2603/2004 Fax: +49 (0)2603/4020 E-Mail: office@heyer-aerotech.de Homepage: www.heyer-aerotech.de Rev. 2.1 as per 01 June 2010 Seite 16 von 16