STEPLADDERS USE AND CARE 3. INSPECTION. NOTICE Not for use or disclosure outside the Bell System except under written agreement

Similar documents
FALL PROTECTION / ELEVATED WORK

Fall Protection and Elevated Work

SHASTA COUNTY OFFICE OF EDUCATION CODE OF SAFE PRACTICES (CONSTRUCTION) Name of Project

Overview. Identify fall hazardous areas Describing potential fall hazards How appropriate portable and extension ladders are used

EMPLOYEE SAFETY ORIENTATION - PHYSICAL PLANT, RESIDENCE

Deans, Directors, Heads of Schools and Departments and Research Institute Directors and Managers

Walking and Working Surfaces: Comprehensive Training

The purpose of this training is to give field technicians awareness training and guidelines on potential hazards they may encounter in the field.

Why Update. OSHA updated Walking Working Standard. Who & What it Covers. Housekeeping (a) 6/25/ nd Leading cause of Workplace fatalities

Slips, Trips, Falls Safety Meeting

8. Fall Protection Procedures WAC

CHAPTER 10 FALL PROTECTION

techconnect CARPENTRY Objectives Unit 2 Workplace Safety TechConnect - STUDENT WORKBOOK 2-1 Workplace Safety - Unit 2

SAFETY FIRST. Inspection Proper Set Up Proper Climbing & Use Proper Storage & Carrying Operating Instructions

Working At Height Policy (including Safe Use of Stepladders guidance)

STEEL TRENCH SHIELDS DW MODELS

WORKPLACE SAFETY INSPECTIONS TABLE OF CONTENTS INTRODUCTION...2 OBJECTIVE...2 REFERENCES...2 PREREQUISITES...2 PRECAUTIONS...2 CHECKLISTS...

User Instruction Manual For Davit Rescue System

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Shoreline Cantilever Lift 2500lb Capacity Models: (108" inside width) - Part # (120" inside width) - Part #

TENNESSEE COMMISSION ON FIRE FIGHTING

DEPARTMENT OF THEATRE AND DANCE CALIFORNIA STATE UNIVERSITY, FULLERTON

GEMTOR. ... when your life is on the line OWNER'S MANUAL. FLW Series Self-Retracting Lanyard/Fall Limiter

Climbing Stick OWNER S MANUAL

Edgewood College Safety Guidelines

HEALTH & SAFETY ARRANGEMENTS FOR MANAGEMENT OF WORK AT HEIGHT

The following items represent the bulk of the exposure to falls on a construction site.

Understanding Why We Fall 3. Identifying Slipping Hazards 4. The Importance of Wearing Proper Footwear 4. Identifying Tripping Hazards 5

PAC. Risk Management Resources. The cost of Workers Compensation can be controlled. Also visit WELLAdvised

INSTRUCTIONS FOR USE

protectors are not required for central office use

CPWR - The Center for Construction Research and Training. Fall Hazard Identification and Control Audit of the Aria Building. City Center Project

OLD GI PART 3, FIXED LADDERS COMPARISON TO NEW RULES

Pole & Tree Climbers. Pole & Tree Climbers. 1972AR Series. Pole Climbers with 1-1/2" Gaffs Complete Set

GENERAL GUIDELINES FOR PROPER RIGGING PRACTICES AND INSPECTION & REMOVAL CRITERIA FOR SLINGS PER OSHA

SPEED SHORE MANUFACTURER S TABULATED DATA "MHS" MODELS. STEEL MANHOLE SHIELDS 4 Single Wall 4 Double Wall 4 Double Wall with Cut-Outs

2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift

A Health and Safety Tip Sheet for School Maintenance Staff. Did you know? Step 1. Identify job hazards. Step 2. Work towards solutions

1.0 Purpose: To provide guidelines for selection, usage, inspection and rejection of rigging equipment

INSTRUCTIONS FOR USE

THE TLC COMPANIES. Self Inspection Program. Self Inspection. Program. Revised 12/13/2002 DC00026

EHS Workplace Inspection Checklist (Ref. SOP QMS-080; EHS-010)

Work Standard CABLE PULLING OPERATIONS

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

Introduction to Evolutionary Hoof Care s New Hoof Care Work Stations TM and Evo Hoof Stands TM Also see Video Instructions at

Pressure Relief Valve Instruction Manual

HEALTH AND SAFETY POLICY APPENDIX B WORKING AT HEIGHT GUIDE AND RISK ASSESMENT

30T A/Manual Hydraulic Shop Press

Fall Protection / Open Holes & Guardrail

Charmborough Bells Risk Assessment and Method Statement

CLUB RISK ASSESSMENT TEMPLATE

Working at Height. Policy and Procedures. Author: Beth Webster Assistant Safety Advisor. On behalf of School Safety Committee.

RESOLUTION A.1045(27) RECOMMENDATION ON PILOT TRANSFER ARRANGEMENTS

Slip, Trip and Fall Prevention

"STEEL FRAMED" ALUMINUM PANEL SHIELDS

NZQA registered unit standard 1178 version 7 Page 1 of 6

MODULAR ALUMINUM PANEL SHIELDS MAPS

Important Safety Information for Users of. Bashlin Climbers

Los Rios Community College District Job Safety Analysis

ISD #535 Rochester Public Schools

Fall Protection Checklist. Guardrail System

Cylinder Tilt Saddle Instruction Manual

Instructions for the following series products:

Tailgate Topic Review

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

Safety Risk Assessment Working at Height: Mobile Tower Scaffold

Inspection & Maintenance

Once the job has been planned and the site has been inspected according to WHS and site requirements it is important to follow work procedure and

DBI SALA Confined Space Rescue Davit System

Slips, Trips and Falls

USER MANUAL Do not throw away these instructions. Read and understand these instructions prior to use of the Lad Grab Safety System.

Lifting Slings. Before equipment use, please read this operation manual carefully. Serial Number: Date Purchased:

Portable Massage Table User Manual

NEXT GENERATION FLEX FENCE

SAFETY PROGRAM MANUAL INJURY & ILLNESS PREVENTION PROGRAM

Ormiston Academies Trust. Ormiston Horizon Academy. Working at Height Policy October 2016

City of Cerritos SWIMMING POOL, SPA AND EQUIPMENT APPLICATION. (Please print or type) Name: Phone: ( )

STEEL TRENCH SHIELDS TUFF-LITE MODELS

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

Personal commitments you can live and work by:

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

HEALTH AND SAFETY METHOD STATEMENT AIR CONDITIONING/REFRIGERATION MAINTENANCE/SERVICE. 2. Clean filters and screens when necessary

CPHS High School Technical Theater

Thanks To Our Sponsors Platinum Sponsor NS Department of Labour and Workforce Development

IMPORTANT: If you have questions on the use, care, application, or suitability of this equipment contact DBI/SALA.

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

Supplementary Operation, Assembly, Maintenance Manual for F3-42 model and optional attachments

20 Ton SD Shop Press Operating Instructions

Job Hazard Analysis. JHA No. FBP-JHA Revision No. Draft General or Job-Specific Description of Work

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS AND INDUSTRY SERVICES DIRECTOR S OFFICE BUREAU OF SAFETY AND REGULATION

Fall Control User Instructions

CHAPTER 2 OFFICE AND SHOP SAFETY

Safe Use of Access Equipment

Florida Department of Juvenile Justice Employee Safety Handbook

MATERIAL HANDLING - FIELD RIGGING SAFETY PROGRAM

User Instructions 1789 Parapet Wall Anchor

SERVICING MULTI-PIECE AND SINGLE PIECE RIM WHEELS

Fall Protection. Fall Speed vs. Reaction Time. Good body reaction time = 0.5 seconds Travel distance in 0.5 seconds = 4 feet (1.21mts.

Fall Speed vs. Reaction Time

Transcription:

BEU SYSTEM PRACTICES AT&7coSmdard SECTION 065-104-301 Issue 3, November 1981 STEPLADDERS USE AND CARE CONTENTS PAGE 1. GENERAL 1 LIBRARY FILECOPY 1. GENERAL 2. DESCRIPTION 3. INSPKTION 4. USE.......................................... 1 1 1 4 1.01 This section covers the use, inspection, care and storage of stepladders and includes safety precautions, to be followed in their use. 1.02 This section is reissued to add the D and E stepladders and to completely revise the section. Since this is a general revision, revision arrows will not be used. The Equipment Test List is affected. A. General.......... B. Selecting Carrect ladder..... c. Currying.......... D. Raising and lowering..... E. Positioning......... 5. CARE AND STORAGE....... A. Care........... B. Storage.......... Figures 1. DSteplodder......... 4 4 5 5 6 7 7 7 2 2. DESCRIPTION 2.01 Two types of stepladders are provided as standard for building service work. They are designated as mechanics and building stepladders. The front or step section of the mechanics stepladder is provided with steps and the back section with oval rungs to permit working from either section. The building stepladder is lighter in construction, and the back section rungs are round and not intended to carry weight. 2.o2 The D and E stepladders have side rails and treads of strong, light softwood and rungs of hardwood. When in use, the sections are locked in the open position by means of hinged spreaders, with the joint guarded, to prevent pinching type injuries. 2.03 The D stepladder (Fig. 1) is available in 6 and 8 foot sizes. The bucket shelf is useful for certain light building service work. 2. 3. E Stepladder.......... Stepladder (4 feet or larger) Maximum Working Height......... 2 4 2.04 The E stepladder (Fig. 2) is available in 3-1/2, 5, 6, 8, 10, and 12 foot sizes and can be used as a general purpose ladder. 3. INSPECTION 4. 5. Carrying a Stepladder Under 8 Feet in Length............ Raising a Stepladder Over 8 Feet in Length.............. 5 6 3.o1 Craft employees equipped with a stepladder shall examine the ladder each week for defects described in Table A. Employees using a stepladder which is normally stored in a garage, storeroom, etc, shall inspect the ladder prior to use. 3.02 Supervisors shall inspect stepladders used by forces under their supervision at least once each quarter. NOTICE Not for use or disclosure outside the Bell System except under written agreement Printed in U.S.A. Page 1

SECTION 065-104-301 / TOP CAP NO STEP LY I!u Fig. 2 E Stepladder Fig. 1 D Stepladder (b) Decay: Disintegration of the wood due to action of wood destroying fungi. 3.o3 The inspection of a stepladder shall be made when the wood is dry. Absorption of moisture may cause swelling of the wood which could tend to conceal defects. 3.04 The ladder shall be examined to determine the condition of all parts as suggested in the following paragraphs. In order to facilitate a careful inspection for defects, it is advisable to place the ladder in a lighted and convenient position for examining all parts. If any of the defects listed in Table A, or if the condition of the ladder is such that there is any doubt about it being safe to use, it should be exchanged at once for one in good condition in accordance with established routine. 3.OS The following is a description of some of the most common defects found when inspecting wood ladders: (a) Cracks: Fractures across the grain of the wood, usually resulting from mechanical stress. (c) (d) Splits: Separations of the wood fibers extending in the direction of the grain. Through Split: A separation extending from surface to the opposite surface. (e) Checks: Separations of the wood along the fiber direction that usually extend across the annual growth rings resulting from stresses during seasoning. (f) Compression Failure: Damage to the side rails may appear as a fine crack, as a fold or crease in the wood fibers, or splintering of the wood fibers. Such defects are usually caused by overloading a ladder to subjecting it to a hard blow, and may subsequently result in breakage of the ladder under normal loads. 3.06 Splits are most likely to occur at rung or tread intersection at the side rail and at the foot of the side rail. Page 2

. 1SS 3, SECTION 065-104-301 TABLEA STEPLADDER WEEKIY INSPECTION PARTOF MAXIMUM UMIT OF STEfl.ADOER lnspscrlon OEFEC?(NOTE 1 AND NOTE 2) correction Delamination See splits Crushed or depressed 1/4 inch Decay Splinters Remove by dressing rail with a w rasp, file, knife, or sandpaper Checks 6 inches long, 1/2 inch deep (superficial checks due to weathering, not exceeding 1/8 inch in depth, are permissible in any number) Compression failure * Cracks SIDERAIL Splits (In any one foot length or siderail) AND 1. End split TREADS Stop riveted 2 inches beyond rivet Not stop riveted 2 inches 2. Splits due to nailing 2 inches beyond each side of nail 3. Splits from rung or rivet hole 2 inches on each side of hole 4. Through split 2 inches Protruding nails. Protruding nails shall be driven fll and set with a nail set. Treadwear 3/4 inch (loss of wood at lip of tread or ladder cap due to wear is permissible if the width of the tread or cap is not reduced by more than 3/4 inches) RUNGS Cracks Splits 2 inch maximum beyond tenon Splinters Acceptable if removable by dressing without exceeding maximum Checks 6 inches long, 1/2 inch deep (superficial checks due to weathering, not exceeding 1/8 inch in depth, are permissible in any number LOoseness Missing Decay of jointt ljnacceptable Excessive wear Diameter less than 7/8 inch I{ARDWARE hose Where practical, loose rivets shal ( BRACES, BRACKETS, be tighted, by placing the head o RI\ ETS, AND lineman s hammer, or equi~alent, HINGES) against the head of loose rivet. P the other end of the rivet with a ball peen hammer until tight. If this does not correct the conditio replace the ladder with local procedures Missing Broken Cracked Defective N ote 1: A ladder having a condition exceeding these limitations shall be removed from service. fvote 2: Defective hardware exceeding these limitations may be repaired or replaced. If not corrected, the ladder must be removed from service. * Compression failure in the wood fibers is most likely to occur at rung location. The wrinkles or creases may appear alone or with some splitting of tbe wood fibers on the opposite side of the rail, Ladders with this condition shall be removed from service. t Decay at joints may be detected by tapping the rung near the side rail with a hammer handle and comparing tbe sound with that of sound rails. Do not strike rungs with head of hammer. Page 3

SECTION 065-104-301 3.07 Thoroughly inspect the ladder on a weekly basis or prior to use for any of the conditions listed in Table A. 3.08 Disposition of Defective Stepladders: Stepladders which have developed defects which cannot be repaired in the field shall be withdrawn from service for repair or destruction. Employees shall tag such ladders as Dangerous, Do Not Use and return for disposition. If the company has established the practice, employees remote from the storeroom shall destroy and dispose of irreparable ladders upon instructions to do so by the supervisor. Defective ladders shall not be destroyed if they are required in connection with an investigation that may be made to determine the cause of an accident or ladder failure. (Fig. 3) is the uppermost horizontal member of the stepladder and is not to be used as a step for working. SIDE RAIL 4. USE A. General 4.o1 Each employee using a stepladder shall at all times assume the responsibility of determining that the ladder is in good condition and that its appearance indicates neither deterioration nor injury sufficient to affect its strength. U--J /// u-j 4.02 When obtaining a stepladder, employees shall examine them for possible defects described in Table A. 4.o3 If a ladder has been dropped or subjected to any other treatment which might damage it, the ladder shall not be used until it has been inspected as described in Part 3 and found to be satisfactory for use. 4.o4 Supervisors shall assure themselves that craft employees perform a visual inspection weekly. Stepladders are to be inspected each quarter by supervision. 4.05 Employees working on stepladders should avoid carrying tools in their pockets if there is any possibility that the tools may fall out. B. Selecting Correct Ladder 4.06 In selecting the proper length of ladders for a job, a ladder of sufficient length will be used so that work can be performed while standing no higher than two steps from the top cap. The top cap Fig. 3 Stepladder (4 feet or larger) Maximum Working Height 4.07 Using ladders that are too short is a common cause of ladder accidents. Be sure to select a ladder of adequate length. 4.08 The D and E type stepladder is an industrialtype ladder built to rigid specifications for durability and safety. Therefore, a customer s ladder or a borrowed ladder is not to be used if a D or E stepladder is available. 4.09 A borrowed stepladder may be used by an employee only after it has been thoroughly inspected and found to be free of any defect which could contribute to an injury. If the ladder is of insufficient length, it shall not be used. 4.10 Do not use or stand on boxes, barrels, radiators, stools, chairs, and other unsafe substitutes for ladders. Page 4

. 1SS 3, SECTION 065-104-301 4.11 The round rungs of the back section of the D and E stepladder provide structural support only and are not intended to carry weight. C. Carrying 4.12 Stepladders up to and including the 8-foot size may conveniently be carried by one person as shown in Fig. 4. 4.13 Ladders over 8 feet in length should generally be carried by two persons, particularly where it is necessary to pass through equipment or office space, operating rooms, or busy corridors. Where it is necessary to handle ladders in narrow corridors, stairways or in congested space of any type, a workman Should not attempt it alone if there is any doubt as to his ability to completely control the ladder. D. Raising and Lowering 4.14 Ladders up to 8 feet in length may conveniently be erected by holding the ladder vertically balanced on the step section legs. The rung section is then pushed away from the step section as far as the workman can reach. The ladder then rests on all four legs and the spreaders are locked down. 4.15 In lowering ladders up to 8 feet in length, the spreaders are first lifted to form an acute angle at the joint. The workman then faces the side of the ladder and with a hand on each rail, pulls the front and back sections together. Care must be taken to grasp the rails so that the finger tips are not in a position where they will be pinched between the side rails of spreaders when the ladder is closed. When Fig. 4 Carrying a Stepladder Under 8 Feet in Length Page 5

SECTION 065-104-301 both sections have been brought together, the workman lowers the ladder. 4.16 Raising or lowering ladders over 8 feet in length in congested space or in close proximity to telephone equipment or moving machinery should be done by two workmen as outlined in paragraph 4.17 and 4.18. 4.17 In raising long stepladders, the ladder is first laid on the floor with the step section up and the feet at approximately the location where it is desired to have it stand. With the foot of the ladder securely braced by one of the workmen in the manner shown in Fig. 5, it is raised to a vertical position by another workman. After raising the ladder to the vertical position, the workman at the rung section then pulls this section open and locks the spreaders down. 4.18 In lowering long stepladders, one workman faces the step section with his feet braced against the bottom of the section. Another workman lifts the spreaders to form an acute angle, then grasps the rung section and lifting it slightly above the floor, pushes it against the front section. The same workman then backs up, lowering the closed ladder while the other man holds it braced against his feet. E. Positioning 4.19 Stepladders are to be placed so as to provide a steady, firm, and reliable position while working from the ladder. 4.20 When it is necessary for a craft person to stand on a stepladder and pull wire og cable, position the stepladder for maximum stability with the pulling force toward the stepladder and in line with the long dimension of the base. I f the wire slips or breaks in this position, the ladder will resist tipping over and the craft person will move toward the Fig. 5 Raising a Stepladder Over 8 Feet in Length Page 6

1SS 3, SECTION 065-104-301 steps and not to the side or backwards stepladder. away from the 4.21 Stepladders shall be placed so the side rails have a secure and reliable footing. When used on a soft or uneven surface, a strong board shall be used to keep the ladder level. 4.22 Ladders shall not be placed on boxes, barrels, or other unstable bases to gain additional height. 4.23 Special precautions must be taken when positioning a stepladder near a door or passageway, and especially where a door will open towards the ladder. When working near a door, secure the door in the open position or arrange to have it locked to avoid it being opened inadvertently. Also, warning devices are to be used to alert others of activity beyond a closed door. 4.24 A stepladder is designed to be self-supporting and its use as a straight ladder will be avoided except where the base can be securely blocked, lashed in position, or held by another employee. 4.25 When in use, the hinged spreaders should be extended to lock the side rails in position and >, to provide maximum spread at the base of the stepladder. 4.26 When required, employees assigned to guard or hold a ladder will not leave the ladder unattended until the other employee has descended the ladder. 4.27 When ascending or descending a ladder, employees shall face the ladder, taking one step at a time. 4.28 The stepladder shall be positioned so an employee can work from the ladder without extending the breastbone beyond either side rail of the ladder. 4.29 The bucket shelf of the D stepladder is not designed to sustain a heavy load and is never to be used as a step. 4.3o Do not leave tools or equipment on the steps, top cap, or bucket shelf of an unattended stepladder. 4.31 Before moving a stepladder, make certain that nothing has been stored on the steps, top cap, or bucket shelf. 4.32 When working on ladders, take care not to overbalance. When it is necessary to reach to the side, take care that the body is not extended so far beyond the side rails as to unbalance the ladder. When it is necessary to exert a strong pull or push on a tool, apply the force in such a manner that if the tool slips, the body will move toward the ladder and not to the side or backwards. 4.33 Never step from one ladder to another without first descending. 5. CARE AND STORAGE A. Care 5.01 Stepladders should not be dropped and heavy objects should not be allowed to fall or rest upon them. 5.02 Ladders shall not be used as guys, braces, or skids, or for other than their intended purpose. s.03 So far as practical, keep ladders free from accumulation of dirt, oil, paint, plaster, etc. 5.o4 Keep ladder rails, rungs, treads, etc, free from splinters by dressing with a rasp, knife, sandpaper, or other suitable means. s.05 Stepladders are not to be painted. Painting could conceal possible defects. Wax should not be used on ladder steps or handrails. B. Storage 5.06 Stepladders that are not being used should be stored at a location where tiey will not be exposed to the elements but where there is ventilation. Never store ladders near radiators, stoves, steam pipes, nor in places where the wood may be subjected to excessive heat or dampness. 5.o7 At garages or storerooms, where ladder racks have not been provided, store stepladders in the verticle position. Do not store ladders in such a position where they would be subjected to pressure that would cause warping or twisting. 5.08 Ladders stored in company vehicles should be stored in such a manner so as to provide ease of access and prevent danger of an injury when with- Page 7

SECTION 065-104-301 drawn for use. Improperly stored stepladders could be subjected to damage, especially splintering, if allowed to strike sharp-edged tools, hardware, or trunk body parts. Page 8 8 Pages