SCBA 1981 AND 1982 2013 NFPA STANDARDS WENT INTO EFFECT FEBRUARY 28, 2014 How does this impact your fire department? We ll be with you every step of the way. Now Shipping NFPA 2013 Approved X3 and AP 75 Air Paks
CRITICAL 2013 EDITION SCBA CHANGES NFPA 1981 Standard on Open Circuit Self-Contained Breathing Apparatus for Emergency Services Personal Alert Safety Systems (PASS) NFPA 1982 Standard on Personal Alert Safety Systems (PASS) HOW THE CURRENT FIRE ENVIRONMENT CHANGED THE NFPA STANDARDS UL Analysis of Changing Fire Dynamics 33% EOSTI low-pressure alarm changes from 25% of cylinder pressure to 33% cylinder pressure + + + AV-3000 HT FACEPIECE Significant high heat and flame testing of the facepiece and lens Enhanced communications The use of EBSS or Buddy Breathers now approved EPIC 3 Safest. Clearest. Most Effective Voice Amplifier Clear person-to-person communication Visual operational indications increase safety Best-in-class battery life ensures reliability Larger Homes New Construction Materials Open Home Geometrics = Changing Fire Dynamics and its Implications Increased Fuel Loads Faster fire propagation Shorter time to flashover Rapid changes in fire dynamics Shorter escape times Reduced time to collapse http://bit.ly/1cr3rxb Changing Fire Environment Resources Universal PASS device alarm Intrinsic safety revision changes Review Information about NFPA 1981, 1982 2013 Edition SCBA Standards www.scott2013firefighter.com NFPA 1981, 2013 Edition NIST Hazard Study South Metro Fire Rescue Video Air Management for Fire Service FDNY Chief (Ret.) John W. Norman, III http://bit.ly/1hznt40 http://1.usa.gov/1fs5q7j http://bit.ly/1jbøgvm http://bit.ly/1lm6xrw http://www.chiefnorman.com
POWERFUL SOLUTIONS TO THE CURRENT FIRE ENVIRONMENT CHALLENGES Air-Pak X3 Enhanced Comfort & Safety The new Air-Pak X3 SCBA platform carries forward many of the features and designs of previous Air-Pak models, including the redundant safety features, ease of use, and durability Scott Air-Pak users have grown to trust. The Air-Pak X3 was designed with additional emphasis on enhancements to comfort, hose and wire management, weight distribution, fireground communications, and serviceability. Hidden hoses and wires for a streamlined design Articulating Shoulder Strap THE ULTIMATE IN SITUATIONAL AWARENESS Scott Safety Exclusive Redundant Safety Systems Deliver the most important commodity firefighters need: AIR, especially in the most demanding situations. Scott Safety exclusive, fireground-proven, redundant backup safety features: Visual Notification in HUD that PASS Device is in Pre-alarm Status Lights with External HUD Provide 360 Visibility REDUNDANT PRESSURE REDUCER 2 reducers in 1 provide automatic backup REGULATOR ¼ turn, dual-locking E-Z Flo+ Regulator No accidental disengagements VIBRALERT Dual primary EOSTI (end-of-service indicator) alarm Tactile and low-frequency sound Powered by breathable air LOUDER. CLEARER. MORE EFFECTIVE. EPIC 3 Communication Platform Vibralert at 33% of Remaining Cylinder Pressure Waist-Mounted Reducer available with either a CGA or Snap-Change Cylinder Connection New Console with Large Sweep Gauge and External HUD External HUD allows Non-Verbal Communication about Air Status EPIC 3 Communication System offers clear communication at the point of speaking for optimum clarity and communication. EPIC AMP Available Now EPIC RI Talk directly over wireless radio Available Fall 2014 CREW TALK (FORMERLY TALK AROUND) Available Spring 2015
LIGHTER. SMALLER. SAFER. Innovative Market Leader of the 5.5 SCBA Introduces the New X3 Responding to the need for a smaller, lighter SCBA, Scott Safety created the new 5.5 cylinders. 30 CYLINDER The 30 cylinder is a small package and offers an almost 10% reduction in weight when compared to an equivalent 4.5 unit. 4.5 5.5 COMPLETE THE SAFETY SPECTRUM Pak Tracker Fire Fighter Locater Systems Notifies remote users of a man-down situation via the HHR (hand-held receiver). The HHR is also a directional receiver that assists with directing rescue teams to the downed personnel. Scott Safety Pak Tracker Range 100 1100 125 FEET 45 60 75 CYLINDER The 75 cylinder is an industry first. EZ-SCAPE Self-Rescue Belt Self-rescue devices for times when a firefighter s life depends on the equipment Four Models to Meet your Needs CARBON CYLINDER SPECIFICATIONS Built around DOT and TC specifications Rated for 30, 45, 60 and 75 durations based on NIOSH breathing rates Hydrostatic testing performed every five years 15-year life expectancy Host a seminar we will give you an AV-3000 HT facepiece and one Epic 3 Voice Amp Host an informative seminar on NFPA 1981, 1982 SCBA standards, 2013 Edition at your fire department with at least five or more fire departments attending, and we will give you one AV-3000 HT facepiece with communication bracket and one Epic 3 Voice Amp. Informational sessions provided by ShurSales & Marketing include: NFPA 1981, 1982 overview - 33% EOSTI (end-of-service indicator) - Buddy Breathing now recognized - New NFPA-compliant facepiece - Universal PASS - Enhanced Communications Product demonstration, including SCBA communications *Minimum of five department must attend in order to qualify for facepiece and amp. INTRODUCING THE NEW 30-YEAR CYLINDER Enhanced durability in a 4500 psi cylinder SEMS II SCBA Electronic Management System Includes Pak Alert PASS and Pak Tracker locator Provides redundant network to provide PASS and low-air notifications to command for optimal safety Sends evacuation requests to interior teams PATENTED MOBILE MESH NETWORK TECHNOLOGY MESH NETWORK SELF HEALING to allow each transmitter to automatically find the best path to the base station, resulting in reduced breaks in the mesh network. Range of 3500 ft. (line of sight) from the base station to a single SCBA Reduces radio traffic during emergency conditions Graphic User Interface (GUI) enables monitoring of personnel on fireground SEMS II SCREEN DASHBOARD
COMPANIES DON T CREATE THE MARKET LEADER CUSTOMERS DO Major fire departments rely on Scott Safety in 8 of 11 largest US cities San Jose San Diego Phoenix Dallas Everett Redmond Spokane County #9 Bellevue Renton Spokane Kootenai County Valley Region Missoula WA Coeur d Alene TVF&R Clackamas County San Antonio Houston New York Philadelphia OR Roseburg Redmond Medford Boise Meridian Jackson Hole ID Reno denotes a sampling of Scott Safety regional accounts. WY NV UT North Pole AK North Star Clark County North Las Vegas Las Vegas Capital City Fire Denver West Metro Aurora South Metro Durango AZ Flagstaff Central Emergency Services MT Billings Scottsdale Phoenix Mesa Tucson Colorado Springs CO San Juan/Farmington Bernalillo Los Alamos Sante Fe County Albuquerque NM Dona Ana County We welcome back Phoenix Fire Department to the Scott Safety family. THANK YOU We appreciate your business and being of service to America s heroes. We proudly support the Scott Firefighter Combat Challenge and Seattle Stair Climb. Scott Safety is proudly made in the USA. www.scott2013firefighter.com 3830 S. Windermere Street, Englewood, CO 80110 Office 303.789.5696 Fax 303.789.5710 www.shur-sales.com ski@shur-sales.com