SCBA 1981 AND NFPA STANDARDS WENT INTO EFFECT FEBRUARY 28, 2014

Similar documents
NFPA 2013 EDITION SCOTT PRODUCTS SCOTT AIR-PAK AND ACCESSORIES

QUESTIONS & ANSWERS AIR-PAK X3 PRO QUESTION. What facepieces are approved for use with the Air-Pak X3 Pro SCBA? ANSWER

AIR-PAK X3 PRO SELF-CONTAINED BREATHING APPARATUS

QUESTIONS & ANSWERS AIR-PAK X3 PRO QUESTION. What facepieces are approved for use with the Air-Pak X3 Pro SCBA? ANSWER

Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus

Dräger PSS 5000 (NFPA 2013 Edition) Self-Contained Breathing Apparatus

FIRE- FIGHTING AT THE NEXT LEVEL

Purchaser Specification Requirements for SCBA Gear

City of Minot Specifications SCBA

Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid

REVISED ATTACHMENT 2 BID PRICING FORM

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 11 Specifications and Overview Revised

The McHenry Township Fire Protection District (MTFPD) invites interested and qualified parties to submit a request for proposal for SCBA.

Bid Specifications for NFPA 1981, 2013 Edition. Self-Contained Breathing Apparatus. General Requirements

Dräger PSS 7000 SCBA (NFPA 2013 Edition) Self-Contained Breathing Apparatus

FIRE FIGHTER I EMERGENCY PROCEDURES WHEN USING SCBA TOPIC: TIME FRAME: 0:30. Level II LEVEL OF INSTRUCTION:

Strong Protection Firefighters Can Count On.

Wireless M7 HUD with auto dim and buddy light

CITY OF FENTON FIRE DEPARTMENT 205 E. Caroline St. Fenton, MI Self Contained Breathing Apparatus (SCBA) Replacement Project October 2018

City of Pigeon Forge Fire Department Tony L. Watson, Chief

REQUEST FOR PROPOSAL RFP FD SCBA. Closing Time: August 23rd, 2018 at 2:00pm Local time

The SCBA shall maintain all NIOSH standards with any of the following types of cylinders listed as provided by the SCBA manufacturer.

Regional SCBA Purchase Bid Specifications

Dräger PSS 4000 Self Contained Breathing Apparatus

The SCBA shall maintain all NIOSH standards with any of the following types of cylinders listed as provided by the SCBA manufacturer.

Air & Gas Technologies, Inc. 42 Industrial Drive Cliff Beach, NJ

BID SHEET. Project: Respiratory Equipment for Fire Department Plain Township Resolution F2 Company Name:

SPECIFICATIONS FOR THE PURCHASE OF FIFTY-EIGHT (58) SELF-CONTAINED BREATHING APPARATUS (SCBA)

BUSINESS OF THE CITY COUNCIL CITY OF MERCER ISLAND, WA

Rapid Intervention Teams

Special Edition. Back To Basics. Search Operations. A Review of the Basics of Fireground Search

SABRE AIRLINE BREATHING APPARATUS

Sperian Warrior SCBA

SCBA Bid Specifications

Wide-view Ultra Elite Facepiece with Kevlar SpeeD-ON Head Harness

PHILADELPHIA FIRE DEPARTMENT OPERATIONAL PROCEDURE # 38 DECEMBER, 2001

TABLE OF CONTENTS PART 11 - FIREFIGHTING

SUBJECT: RAPID INTERVENTION CREW (RIC) SOG DATE ADOPTED: OCTOBER 18, 2012 REVISED: PAGES: 7

Training. Level of training on the Scott 4.5 SCBA air pack must be completed in the order stated on the pages below.

Dräger Bodyguard 1500 Warning Device

Notice July 2, 2018 City of Greenville Greenville, Michigan Department of Public Safety. To Bidders SELF CONTAINED BREATHING APPARATUS

Dräger PSS 3000 Self-Contained Breathing Apparatus

1. TAKING THE HEAT 2. VIRTUALLY BULLET-PROOF ELECTRONICS

FIRE SERVICES CATALOG

Bradford Fire Department. Seeks Bids for the Purchase of Self Contained Breathing Apparatus and Related Equipment GENERAL SPECIFICATIONS WARRANTY

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE SCBA PAGE 1 OF 14 Maintenance Revised

MSA G1 SCBA. Pre-production images and information provided, production model may vary.

MSA G1 SCBA. Pre-production images and information provided, production model may vary.

FIRE SERVICES CATALOG 2017

AirHawk II AirMask. Because every life has a purpose...

How many intakes can I operate from the control center? Up to 4 intakes can be controlled from the control center.

The term MAYDAY typically will be used in the following situations:

UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to:

Improving RIT Operations

AirHawk SCBA. Now available with MSA s Advantage 4000 Facepiece

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

AIR SYSTEMS CYLINDERS PASS DEVICES SCBA SCBA CLEANING

MSA G1 SCBA. USA Edition

We ve worked for almost a hundred years to keep professionals breathing in hazardous environments

Wired Communication in Confined Space

NOTICE TO Bidders. Sealed bids subject to the conditions contained herein will be received until 3:00p.m. on October

#121 April 29, 2002 UPDATE OF TECHNICAL BULLETINS

EWC EARLY WARNING CONTROL OPERATIONAL PRESENTATION. Charles Dickens (757)

PROPAK-EZ-FLO HIGH PERFORMANCE, RUGGED DEPENDABILITY, TRUSTED TECHNOLOGY

MABAS Division V Training Guide RIT. Appendix C

AIR SYSTEMS CYLINDERS PASS DEVICES SCBA SCBA CLEANING. /airsystems. CARRY HANDLES Rated up to 600 lbs. pull force to use as a drag handle

Product Numbers & Ordering Information

AirHawk II Air Mask. Keep the basics. Add the choices.

Dräger Bodyguard 1000 Warning Device

City of Oneonta. Oneonta Fire and Rescue Servic

Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet

Article 203 Self-Contained Breathing Apparatus (SCBA)

FIRE CHIEF S ASSOCIATION OF BROWARD COUNTY

Honeywell TITAN SCBA

One Mask. Countless Possibilities. [ Introducing the new Advantage 4000 Facepiece ]

Respiratory Protection. Pressure Demand Supplied Air Respirator (PD-SAR)

PremAire Cadet Escape. Combination Supplied-Air Respirator with Escape Cylinder

Work Horses of the Breathing Air Industry

STANDARD OPERATING GUIDELINE

ACSi THE FUTURE OF SCBA

MEDICAL EQUIPMENT CATALOG

RAPID INTERVENTION CREW TEAMS

AIR SYSTEMS AIR CYLINDERS CLEANING & STORAGE FULL-FACE MASKS PASS DEVICES

M7XT Parts List PARTS LIST. TAL 1504 (L) Rev. 2 MSA 2015 Prnt. Spec (I) Mat Doc

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

POLICY AND PROCEDURE DIVISION OF FIRE AND RESCUE SERVICES

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

Fire and Rescue Operations Chapter 03 2 In, 2 Out and Rapid Intervention March 2009

PANTHER. Self-Contained Breathing Apparatus (SCBA) Product Specification Sheet

Course Firefighter I. Unit II Safety and Orientation

Alabama Smoke Diver Policies

Manitowoc County MABAS Division 128 Rapid Intervention Policy

===============================================================

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

SITUATIONAL AWARENESS, DISORIENTATION and IMPROVING FIREFIGHTER SURVIVAL AT STRUCTURAL FIRES

Higher efficiency. Proven durability. MARINE FORKLIFTS

North Carolina Fire and Rescue Commission Live Fire Audit Form

We ve worked for almost a hundred years to keep professionals breathing in hazardous environments

SE40. positive pressure demand respirator for emergency response in CBRN environments

Yakima County Fire District 12 Standard Operating Guidlines SOG 2-11 Interior Structure Firefighting

Transcription:

SCBA 1981 AND 1982 2013 NFPA STANDARDS WENT INTO EFFECT FEBRUARY 28, 2014 How does this impact your fire department? We ll be with you every step of the way. Now Shipping NFPA 2013 Approved X3 and AP 75 Air Paks

CRITICAL 2013 EDITION SCBA CHANGES NFPA 1981 Standard on Open Circuit Self-Contained Breathing Apparatus for Emergency Services Personal Alert Safety Systems (PASS) NFPA 1982 Standard on Personal Alert Safety Systems (PASS) HOW THE CURRENT FIRE ENVIRONMENT CHANGED THE NFPA STANDARDS UL Analysis of Changing Fire Dynamics 33% EOSTI low-pressure alarm changes from 25% of cylinder pressure to 33% cylinder pressure + + + AV-3000 HT FACEPIECE Significant high heat and flame testing of the facepiece and lens Enhanced communications The use of EBSS or Buddy Breathers now approved EPIC 3 Safest. Clearest. Most Effective Voice Amplifier Clear person-to-person communication Visual operational indications increase safety Best-in-class battery life ensures reliability Larger Homes New Construction Materials Open Home Geometrics = Changing Fire Dynamics and its Implications Increased Fuel Loads Faster fire propagation Shorter time to flashover Rapid changes in fire dynamics Shorter escape times Reduced time to collapse http://bit.ly/1cr3rxb Changing Fire Environment Resources Universal PASS device alarm Intrinsic safety revision changes Review Information about NFPA 1981, 1982 2013 Edition SCBA Standards www.scott2013firefighter.com NFPA 1981, 2013 Edition NIST Hazard Study South Metro Fire Rescue Video Air Management for Fire Service FDNY Chief (Ret.) John W. Norman, III http://bit.ly/1hznt40 http://1.usa.gov/1fs5q7j http://bit.ly/1jbøgvm http://bit.ly/1lm6xrw http://www.chiefnorman.com

POWERFUL SOLUTIONS TO THE CURRENT FIRE ENVIRONMENT CHALLENGES Air-Pak X3 Enhanced Comfort & Safety The new Air-Pak X3 SCBA platform carries forward many of the features and designs of previous Air-Pak models, including the redundant safety features, ease of use, and durability Scott Air-Pak users have grown to trust. The Air-Pak X3 was designed with additional emphasis on enhancements to comfort, hose and wire management, weight distribution, fireground communications, and serviceability. Hidden hoses and wires for a streamlined design Articulating Shoulder Strap THE ULTIMATE IN SITUATIONAL AWARENESS Scott Safety Exclusive Redundant Safety Systems Deliver the most important commodity firefighters need: AIR, especially in the most demanding situations. Scott Safety exclusive, fireground-proven, redundant backup safety features: Visual Notification in HUD that PASS Device is in Pre-alarm Status Lights with External HUD Provide 360 Visibility REDUNDANT PRESSURE REDUCER 2 reducers in 1 provide automatic backup REGULATOR ¼ turn, dual-locking E-Z Flo+ Regulator No accidental disengagements VIBRALERT Dual primary EOSTI (end-of-service indicator) alarm Tactile and low-frequency sound Powered by breathable air LOUDER. CLEARER. MORE EFFECTIVE. EPIC 3 Communication Platform Vibralert at 33% of Remaining Cylinder Pressure Waist-Mounted Reducer available with either a CGA or Snap-Change Cylinder Connection New Console with Large Sweep Gauge and External HUD External HUD allows Non-Verbal Communication about Air Status EPIC 3 Communication System offers clear communication at the point of speaking for optimum clarity and communication. EPIC AMP Available Now EPIC RI Talk directly over wireless radio Available Fall 2014 CREW TALK (FORMERLY TALK AROUND) Available Spring 2015

LIGHTER. SMALLER. SAFER. Innovative Market Leader of the 5.5 SCBA Introduces the New X3 Responding to the need for a smaller, lighter SCBA, Scott Safety created the new 5.5 cylinders. 30 CYLINDER The 30 cylinder is a small package and offers an almost 10% reduction in weight when compared to an equivalent 4.5 unit. 4.5 5.5 COMPLETE THE SAFETY SPECTRUM Pak Tracker Fire Fighter Locater Systems Notifies remote users of a man-down situation via the HHR (hand-held receiver). The HHR is also a directional receiver that assists with directing rescue teams to the downed personnel. Scott Safety Pak Tracker Range 100 1100 125 FEET 45 60 75 CYLINDER The 75 cylinder is an industry first. EZ-SCAPE Self-Rescue Belt Self-rescue devices for times when a firefighter s life depends on the equipment Four Models to Meet your Needs CARBON CYLINDER SPECIFICATIONS Built around DOT and TC specifications Rated for 30, 45, 60 and 75 durations based on NIOSH breathing rates Hydrostatic testing performed every five years 15-year life expectancy Host a seminar we will give you an AV-3000 HT facepiece and one Epic 3 Voice Amp Host an informative seminar on NFPA 1981, 1982 SCBA standards, 2013 Edition at your fire department with at least five or more fire departments attending, and we will give you one AV-3000 HT facepiece with communication bracket and one Epic 3 Voice Amp. Informational sessions provided by ShurSales & Marketing include: NFPA 1981, 1982 overview - 33% EOSTI (end-of-service indicator) - Buddy Breathing now recognized - New NFPA-compliant facepiece - Universal PASS - Enhanced Communications Product demonstration, including SCBA communications *Minimum of five department must attend in order to qualify for facepiece and amp. INTRODUCING THE NEW 30-YEAR CYLINDER Enhanced durability in a 4500 psi cylinder SEMS II SCBA Electronic Management System Includes Pak Alert PASS and Pak Tracker locator Provides redundant network to provide PASS and low-air notifications to command for optimal safety Sends evacuation requests to interior teams PATENTED MOBILE MESH NETWORK TECHNOLOGY MESH NETWORK SELF HEALING to allow each transmitter to automatically find the best path to the base station, resulting in reduced breaks in the mesh network. Range of 3500 ft. (line of sight) from the base station to a single SCBA Reduces radio traffic during emergency conditions Graphic User Interface (GUI) enables monitoring of personnel on fireground SEMS II SCREEN DASHBOARD

COMPANIES DON T CREATE THE MARKET LEADER CUSTOMERS DO Major fire departments rely on Scott Safety in 8 of 11 largest US cities San Jose San Diego Phoenix Dallas Everett Redmond Spokane County #9 Bellevue Renton Spokane Kootenai County Valley Region Missoula WA Coeur d Alene TVF&R Clackamas County San Antonio Houston New York Philadelphia OR Roseburg Redmond Medford Boise Meridian Jackson Hole ID Reno denotes a sampling of Scott Safety regional accounts. WY NV UT North Pole AK North Star Clark County North Las Vegas Las Vegas Capital City Fire Denver West Metro Aurora South Metro Durango AZ Flagstaff Central Emergency Services MT Billings Scottsdale Phoenix Mesa Tucson Colorado Springs CO San Juan/Farmington Bernalillo Los Alamos Sante Fe County Albuquerque NM Dona Ana County We welcome back Phoenix Fire Department to the Scott Safety family. THANK YOU We appreciate your business and being of service to America s heroes. We proudly support the Scott Firefighter Combat Challenge and Seattle Stair Climb. Scott Safety is proudly made in the USA. www.scott2013firefighter.com 3830 S. Windermere Street, Englewood, CO 80110 Office 303.789.5696 Fax 303.789.5710 www.shur-sales.com ski@shur-sales.com