Decontamination Procedures for Gilson Pipettes

Similar documents
Other languages available on our website:

Ergonomic Pipetting for Problem Liquids!

NEO. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

The pipette of Choice for Problem Liquids!

Comfortable and Secure by Nature!

PIPETMAN F ENGLISH. Other languages available on our website:

User s Guide VARIABLE VOLUME MODELS. Variable volume single and multichannel models and fixed volume models

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

WITOPET PREMIUM PIPETTE USER S GUIDE

VWR HIGH PERFORMANCE PIPETTOR

Minipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

Contents Page Warranty

MULTICHANNEL. Labnet International, Inc.

RayPette Plus Autoclavable Pipette. User Manual

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

CALIBRATION AND ADJUSTMENT

A N B P G J I C D L D E

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

The pipettes cover a volume range from 0.1µl to 10ml.

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Service and Repair Manual

Chapter 2. Pipetting techniques. Guide to Pipetting

Pipettor. User Manual

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

SoCal BioMed, LLC 4695 MacArthur Court, 11th Floor Newport Beach, CA Phone: +1 (424) Fax: +1 (323)

Eppendorf Research fix variable multi Instruction Manual Bedienungsanleitung Mode d emploi Instruzioni d impiego Manual de Instrucciones

Varipette Operating manual

Technology for Vacuum Systems Instructions for use

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

12S 1st Stage. -Maintenance Procedure-

User's Manual. Autoclavable Nichipet EX Plus Digital micro pipette for liquid handling CERTIFIED ISO9001

Technology for Vacuum Systems. Decontamination

DISCOVERY PRO - features

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Tacta Mechanical Pipette User Manual

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

A N B P F G J I C D D L A B C D E F

Adjust the Volume Display

Transferpette -8/-12

TECHNICAL CHARACTERISTIC CT 071

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Corning Step-R. Repeating Pipettor. Instruction Manual

Instructions for use Compressed air injector with water trap

Transferpette. Lightweight precise rugged reliable!

Transferpette. Lightweight precise rugged reliable!

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

VITLAB micropipette. Standard Operating Procedure (SOP)

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

A N F G J I C D D L A B C D E F

Phone: Fax: More information:

Operating Instructions. Rainin Classic Manual Pipette

School of Biological Sciences: Zoology Building

Pressure relief valve

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

GALISO SOAP OPTION FOR PCT-ADW-D

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Standard Operating Procedure (SOP)

FIELD TIP SHEET. Mark the bag with black permanent marker before filling it with water.

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

Phone: Fax: More information:

Assembly and Installation Procedures

Thermo Scientific F1-ClipTip Single Channel Multichannel

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Installation, Operation, and Maintenance Manual

Chapter 1. Selecting the best pipette for your application

Sterile Visual Flow Indicator

Techcon Systems TS1258 Pressure Pot

Techcon Systems TS1254 Pressure Pot

Cavitron DualSelect. Introduction ENGLISH. Directions For Use. Cavitron DualSelect Dispensing System ENGLISH 1

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

DM-MBST (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Shifting lever. EZ-FIRE Plus ST-EF500 ST-EF510

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

VITLAB Volumetric instruments

RG1200 Service and Repair Manual

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

LEAK SEALING SYSTEMS

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

LRS(H)4 Pressure-Reducing Regulator User Manual

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Operation and Maintenance Instructions

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

HI 2314 HI 2315 HI 23151

EcoCell Vertical Electrophoresis Unit

FOR SAFE AND CORRECT USE

Dissolved Oxygen Sensor

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Operating Instructions

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Hygea Ultrasonic Validation Kit

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

Transcription:

Standard Operating Procedure for Pipettes Decontamination Procedures for Gilson Pipettes (defined for Users to Incorporate in SOPs) in Accordance with ISO8655 Standard Procedure LT802288/E - 2008 Gilson SAS All rights reserved March 2008

Contents Introduction 3 Decontamination Room 3 Equipment and Clothing 3 Solutions for Decontaminating and Cleaning 4 Precautions 4 Procedure for End-user s 5 Complete Procedure for Gilson Distributors 6 Checking the Outside of the Package for Radioactivity 6 Unpacking the Pipettes and Checking for Radioactivity 6 Disassembly Procedures 8 Decontamination Methods 10 Manual Method 10 Immersion Method 11 Associated Documents 12 Notes 13

Introduction This document contains Decontamination Procedures suitable for Pipetman P, Pipetman Neo, Pipetman F, Pipetman Ultra (Single and Multichannel), Pipetman Concept (Single and Multichannel), Microman and Distriman ; it describes how to decontaminate specific component parts of these pipettes. Only after preliminary checks for radioactivity may the pipette be unpacked and disassembled for subsequent cleaning and decontamination, using disposable gloves. End-users must decontaminate their pipettes before sending them to their local Gilson Service Center. * To be carried out by suitably qualified people only. End-users should refer to their local distributor for further information. Damaged parts: contact your local Gilson distributor, who will either supply you with genuine Gilson userlevel replacements parts or who will service the pipette for you. Decontamination starts with radioactivity checks using a validated Geiger-Müller counter equipped with probes capable of detecting gamma, beta and X-rays. Cleaning is integrated in the combined chemical and biological Decontamination Procedure. Complete servicing consists of three mandatory procedures, to be performed in the following order: decontamination, maintenance [see respective Maintenance Procedure*], calibration [see respective Adjustment Procedure*] and verification [see Verification Procedure for Accuracy and Precision]. Parts that are found to have been damaged or to have been attacked chemically must be replaced with new ones before reassembling the pipette. Any parts that you remove from the pipette because they suffered chemical or mechanical damage should be decontaminated before being discarded. Decontamination Room The decontamination room must be separate from all other rooms in the laboratory. For safety reasons, only authorized personnel should be allowed to enter the decontamination room. Equipment and Clothing 1) Protective clothing, safety glasses, and disposable gloves. 2) Geiger-Müller counter for detecting beta, gamma and X-rays. 3) Benches, one equipped with a safety hood (without filter). 4) Disposable bench covers and safety bags. 5) A safety box (e.g. a lead box). 6) A separate identifiable plastic box for each pipette. 7) For the manual method, small round brushes for cleaning the insides of the tip-holders. 8) For the alternative immersion method: an ultrasonic bath, lattice boxes and lattice container, plus a thermostatically controlled oven (50 C to 60 C).

Introduction Solutions for Decontaminating and Cleaning Gilson recommends the use of a solution containing a mixture of chemicals: a detergent for chemical cleaning and a disinfectant for biological decontamination. Basically, you need to find a product effective against virus, bacteria, fungi, chemicals liquids. For example: Aniospray 41 and Aniosyme P.L.A. from Anios; if you have difficulty in obtaining either of these solutions, you may contact Gilson for a list of distributors. The solutions mentioned above are compatible with pipette materials and have a wide spectrum of action. Other solutions may be used, however you must check with your supplier that the solution you use does not attack any of the following materials: aluminium, stainless steel, nitrile, ABS (acrylonitrile butadiene styrene), PBT (polybutene terephtalate), PC (polycarbonate), PE (polyethylene), PEI (polyether imide), POM (polyoxymethylene), PPS (polyphenylene sulfide), PTFE (polytetrafluoroethylene), PVDF (polyvinylidene fluoride) and PMP (polymethylpentene). Precautions Decontamination implies that for any person in contact with returned pipettes there is a risk of contamination. Therefore, systematic vaccination against hepatitis B of all persons in contact with pipettes is highly recommended. Because other pathogens could be present, great care should be taken when handling pipettes. Use disposable gloves and any other protective clothing that may be necessary throughout the Decontamination Procedure. Disposable gloves must be worn at all times during the cleaning and decontamination procedures. Follow the regulations in force in your country for handling and disposing of material that has been exposed to radioactivity. Dispose of any damaged parts and used water or chemical solutions safely, in accordance with the regulations in force in your country. Record the serial number, which is engraved on the body of the pipette, and identify the boxes used to contain the component parts of the pipette with this serial number.

Procedure for End-users If your pipettes are used for dispensing radioactive liquids, you must check each pipette separately for radioactivity. If a pipette is found to be radioactive, put it in a safety box and proceed according to the regulations that apply in your country. If your pipettes are not used for dispensing radioactive liquids or are found not to be radioactive: - disassemble the pipettes in accordance with the instructions given on 8. - decontaminate and dry the pipettes in accordance with the instructions given on 10.

Complete Procedure for Gilson Distributors The complete procedure comprises the following steps: - checking the outside of the packaging for radioactivity, - unpacking the pipettes and checking each pipette separately for radioactivity, - disassembling the pipettes in accordance with the instructions given in the Maintenance Procedure, - decontaminating and drying; cleaning-up the work area, - transfering the pipettes in their boxes to the repair room for reassembly. Checking the Outside of the Package for Radioactivity Procedures for storage and disposal must be in accordance with the laws and directives (national and international) that apply in your country. 1) Place a disposable absorbent cover on the bench, below the safety hood. 2) Upon receipt, put the package containing the pipette(s) on the disposable cover, below the safety hood. 3) Before undoing the package, check it for radioactivity (beta, gamma, and X-rays) using a Geiger-Müller counter 4) If the level of radioactivity exceeds 10 Bq for beta and gamma rays or 25 Bq for X-rays, store the package in a safety box or dispose of it. 5) We recommend that if the level of radioactivity is less than or equal to 10 Bq for beta and gamma rays or 25 Bq for X-rays, you may unpack the pipette(s). However, if the laws and directives (national and international) that apply in your country prescribe different limits, you should use the lowest limit. Unpacking the Pipettes and Checking for Radioactivity 1) Place a disposable absorbent cover on the bench, below the safety hood. 2) Unpack the pipette(s) and place them on the disposable cover, below the safety hood. Take out the customer s shipping documents before disposing of the packaging. 3) Check the pipettes individually for radioactivity (beta, gamma, and X-rays) using a Geiger-Müller counter. 4) If the level of radioactivity exceeds 10 Bq for beta and gamma rays or 25 Bq for X-rays store the pipette in a safety box or dispose of it. Procedures for storage and disposal must be in accordance with the laws and directives (national and international) that apply in your country.

Complete Procedure for Gilson Distributors 5) We recommend that if the level of radioactivity is less than or equal to 10 Bq for beta and gamma rays or 25 Bq for X-rays, you may disassemble the pipette(s). However, if the laws and directives (national and international) that apply in your country prescribe different limits, you should use whichever of the limits are the lower.

Disassembly Procedures The following are brief summaries of disassembly procedures. We strongly recommend you to refer to the appropriate User s guide for more information. Please refer also to the opposite schematics. It is recommended that you replace the seal and O-ring with new ones. Your local distributor is able to supply you, genuine Gilson spare parts and to advise you about the way to service your pipette. Pipetman P, Pipetman Neo and Pipetman F 1) Push the tip-ejector button and remove the tip-ejector. 2) Unscrew the connecting nut. 3) Remove the piston assembly from the tip-holder. 4) Remove the seal and the O-ring from the piston. Microman 1) Unscrew the capillary-holder. 2) Remove the clamp assembly and return spring from the capillary-holder. Distriman Disassemble the piston retaining assembly. 1) Hold your Distriman in the horizontal position with the red flag in front of you. 2) Hold the filling knob at its lower position using the thumb of on hand. 3) Press lightly on the white locking tab with a screwdriver. 4) Move the filling knob toward the upper position to separate it from the assembly. 5) Pull the assembly out of the Distriman s neck, taking care not to lose the small red flag. Pipetman Ultra and Pipetman Concept Single channel 1) Push the ejection button and remove the tip-ejector by rotating it gently counterclockwise. 2) Unscrew both parts of tip-holder (remove also O-ring and seal). 3) Set the counter to zero for Pipetman Ultra. 4) Unscrew the connecting nut. 5) Pull on the spring guide to remove the piston from the body. Pipetman Ultra and Pipetman Concept Multichannel 1) Push the tip-ejector button and remove the ejector clip by rotating it gently counterclockwise. 2) Set the counter to zero for Pipetman Ultra. 3) Unscrew the connecting nut to separate the head from the body. 4) Take the head and remove the two screws and pull the ejector-cover away. 5) Remove the wire clip(s), and push awards (the piston cover) to flip upwards it. 6) Remove the tip holders and pistons. 7) Pull each piston out of each tip holder.

Disassembly Procedures Pipetman P/Neo/F Pipetman Ultra Single & Multichannel Pipetman Concept Single & Multichannel Lower Part Upper Part (Body) Pipetman P/Neo/F You may wipe or immerse the following parts: - tip ejector, - tip-holder, - connecting nut. Pipetman Ultra and Concept (Single) You may wipe or immerse the following parts: - tip ejector, - tip-holder (upper and lower parts), - piston assembly, - connecting nut. Pipetman Ultra & Concept Multichannel You may wipe or immerse the entire head or individually the following parts: - piston tray, - ejector-cover, - tip-holder, - piston and spring, - connecting nut, - clips. Wipe only, Do not immerse.

Decontamination Methods Liquid must not enter the upper part (body) of the pipette. Two methods are described below: the manual method, which can be used with any part of the pipette, and the immersion method, which is only for the parts that can be removed from the upper part (body) of the pipette. The body of the pipette must not be immersed in any liquid. The manual method is quicker to perform than the immersion method. If an ultrasonic bath is not available you can still immerse the specified parts after cleaning them manually. When the decontamination process is finished, you should disinfect the empty boxes, the brushes (manual method), the ultrasonic bath (immersion method) and the bench with a 10 % v/v sodium hypochlorite solution; then rinse with water. Manual Method Note: You may find it difficult to clean inside the lower part of the smaller pipettes (e.g. P2, P2N or U2, P10, P10N, U10 or C10), in which case you should either replace the part with a new one or use an ultrasonic bath (immersion method). 1) Wipe the body of the pipette with a tissue soaked in Aniospray 41. 2) Place the body of the pipette in a clean box. 3) Spray the other disassembled pipette parts with Aniospray 41. 4) Clean inside the tip-holder with small (soft plastic) brushes (both parts). 5) Dispose of the O-rings and/or piston seals and any damaged parts (after cleaning them). 6) Place the remaining clean parts from one pipette in a separate box (identified by serial number for cross-referencing with upper part (body). 7) Wipe with a tissue soaked in distilled water, then leave the pipettes to dry (about 15 minutes). Immersion Method 1) Fill the ultrasonic bath with hot water, then add the Aniosyme P.L.A to a concentration of 0.5 % (refer to the instructions given by Anios). 2) Place the component parts from an individual pipette in a separate lattice-box (identified with that pipette s serial number). Put any damaged parts from the batch of pipettes in another box and wash them before disposing of them. 3) Place all of the lattice boxes in a lattice container. 4) Immerse the lattice container in the ultrasonic bath for 15 minutes. 5) Remove the lattice container (containing the lattice boxes and pipette parts) from the ultrasonic bath. 10

Decontamination Methods 6) Rinse the lattice container (containing the lattice boxes and pipette parts) thoroughly with warm water (60 C maximum). 7) Place the component parts (still in their individual lattice-boxes) in an oven for about 30 minutes at 50 C to 60 C. 8) Wipe the upper part (body) of each pipette with a tissue soaked with Aniospray 41, then wipe it with a tissue soaked with distilled water. 9) Reunite the upper part (body) of the pipette with its component parts by placing it in the lattice-box having the same serial number. Damaged Parts: Contact your Gilson Distributor to obtain genuine Gilson spare parts for any damaged parts. Your distributor will also be able to manage the servicing of your pipettes. 11

Associated Documents Documents Pipetman Ultra User s Guide Pipetman P User s Guide Pipetman Neo Addendum Pipetman F User s Guide Pipetman Ultra Multichannel User s Guide Pipetman Concept User s Guide Pipetman Concept Multichannel User s Guide Microman User s Guide Distriman User s Guide Gilson Reference LT801441 LT801117 LT801511 LT801118 LT801462 LT801489 LT801494 LT801367 LT801285 12

Notes 13

World Wide Web: www.gilson.com E-mail: sales@gilson.com, service@gilson.com, training@gilson.com World Headquarters Gilson, Inc. 3000 Parmenter Street, P.O. Box 620027, Middleton, WI 53562-0027, USA Telephone: (1) 800-445-7661 or (1) 608-836-1551 Fax: (1) 608-831-4451 Gilson SAS 19 avenue des Entrepreneurs, B.P. 145 95400 Villiers-le-Bel, France Telephone: (33) 1-34-29-50-00 Fax: (33) 1-34-29-50-20