Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Similar documents
Pipetting Small Volumes

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

MOLEBIO LAB #1: Microquantity Measurement

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Pipetting and Determining Protein Concentration

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Pipettor. User Manual

Improving Pipetting Techniques

Improve pipetting results in pharmaceutical formulation by using MICROMAN E

Adjust the Volume Display

Chapter 2. Pipetting techniques. Guide to Pipetting

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Inquiry Module 1: Checking the calibration of a micropipette

Using a micropipette to transfer exact liquid measurements in scientific experiments By: Nicole Hume

RayPette Plus Autoclavable Pipette. User Manual

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

How to Measure R7.1. Reference. I. Linear dimensions

The pipettes cover a volume range from 0.1µl to 10ml.

A N F G J I C D D L A B C D E F

Real World Metric System

MULTICHANNEL. Labnet International, Inc.

SOP-111 Pipetting Small Volumes

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Calibration of Volumetric Glassware

Gel Loading Practice MiniLab

CHM250 Calibration and Measurement Lab. Balance Calibration

Technical Procedure for General Laboratory Equipment

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Standard Operating Procedure. Air Displacement Pipette Calibration

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Experiment 1 Use of Micropipettes: measuring volume accurately

Transferpette -8/-12

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

VOLUMETRIC TECHNIQUES

Fisherbrand. Finnpipette INSTRUCTIONS FOR USE PARK LANE Pittsburgh PA

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

A N B P F G J I C D D L A B C D E F

Operating Instructions. Rainin Classic Manual Pipette

User s Manual. Autoclavable & UV r e s i s t a n t. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

Experiment #2. Density and Measurements

User s Manual. Digital micro pipette for liquid handling CERTIFIED ISO9001

Measuring Mass and Volume

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

BASIC LABORATORY TECHNIQUES (Revised )

Lab Equipment ANALYTICAL BALANCE

Any laboratory is equipped with specific tools, equipment,

BASIC LABORATORY TECHNIQUES (Revised )

Read over Techniques #2, 4, 5, 6, and 9 in the Demonstrations of Nine Practical Lab Techniques booklet.

Hands-On Experiment Density and Measurement

LABORATORY EXERCISE I METRIC SYSTEM OF MEASUREMENT

Purpose. Introduction

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

ali-q TM Gravimetric Verification Procedure

How to Use: 1. Hold the pipette like you are going to shake hands with it.

CHM Introductory Laboratory Experiment (r17sd) 1/13

APPENDIX A CORRECT USE OF DIGITAL PIPETTES

The use of the analytical balance, and the buret.

Varipette Operating manual

Measurements. Metric System

User s Manual. Autoclavable & UV resistant Nichipet EX II. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC)

CHEM 321 Experiment 1

Other languages available on our website:

VITLAB micropipette. Standard Operating Procedure (SOP)

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Nichipet EX Plus II. User s Manual. Autoclavable & UV resistant. Digital micro pipette for liquid handling

A N B P G J I C D L D E

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

Eliminating Sources of Pipetting Error in the Forensic Laboratory David M. Epstein Director of Scientific Operations. Abstract.

EXPERIMENT 1 BASIC LABORATORY TECHNIQUES AND TREATMENT OF DATA MEASUREMENTS

LABORATORY TECHNIQUES. Pouring Liquids

MICROMAN ENGLISH. Other languages can be consulted and downloaded on our website,

Experiment 1 Basic Laboratory Operations

PIPETMAN F ENGLISH. Other languages available on our website:

QAM-I-117 Volumetric Equipment Calibration Verification

SoCal BioMed, LLC 4695 MacArthur Court, 11th Floor Newport Beach, CA Phone: +1 (424) Fax: +1 (323)

SoftGrip Single Channel Pipettes User Manual New Photo To Come

Accuracy and Precision

Transferpette. Single and Multichannel Pipettes

CHM 317H1S Winter Section P Procedures and Tables

Recording Significant Figures

VWR HIGH PERFORMANCE PIPETTOR

VITLAB Volumetric instruments

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Picus NxT Electronic Pipettes Ergonomic, Efficient, & Safe

D. De La Matter 2004 Swimming Pool Chemistry STUDENT ACTIVITIES:

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

The Ideal Gas Constant

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

Before you start sampling, be sure to read

Userts Manual. Digital micro pipette for liquid handling. In Vitro Medical Diagnostic Devices (98/79/EC) Annex III self-declared ISO 8655 STANDARD

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

00 Experiment: Basic Lab Techniques, Compliance of GLP and Calibration of Glassware

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Transcription:

Lab Skills Practice: Pipetting Small Volumes B3 Summer Science Camp at Olympic High School 2016

Pipetter types Serological and micropipettes are used to accurately transfer small liquid volumes (micro-liter to milli-liter) accurately and precisely. Continuously adjustable Can be set to any transfer volume within its range, which is from 10% of the marked volume up to but not beyond the marked volume. Micropipetters: 0.0001-1.0 ml Serological: 1-25ml

Serological pipettes Manual Pump Pipetter Electronic Pump Meniscus Watch: eye level, lowest part estimate volumes between lines Weller UNCC

The MicroPipetter - 1 Make sure you know how to Select the proper micropipetter to transfer a specified volume of sample volume needed must be inside the range of the device, the lowest volume is 1/10 th of the maximum volume, which is how the pipette is labeled. Set a specified volume on the pipette volume indicator using the volume adjustment knob Volume is read on the side window Adjustment knob is either the top plunger itself or just below the plunger Read the volume setting in correct units For most of the micropipetters the unit is a microliter (ul), one millionth of a liter. The 1ml micropipetter (this is 1000ul) shows tens of microliters (20 means 200ul or 0.200ml, with the final amount estimated with a division between 20 and 21 that is really between 200 and 210.

The MicroPipetter - 2 Make sure you know how to Select the correct tips and properly seat them (tap lightly holding the device vertically) To use: pipetter is held vertically, plunger is depressed, tip end is placed a little below the liquid surface, liquid is drawn up slowly, tip is withdrawn from the liquid, moved to target container, plunger is depressed slowly, tip is dragged up along side of container. Properly eject the tip into a waste container.

Parts of the Micropipetter Pipette tips

Operating the Micropipette Step 1: Select the correct pipetter and set the volume Pipettors 3 Volumes: Volume Adjustment Knob: Digital Volume Indicator:

Step 2: Read the volume Operating the Micropipette How to Read the Volume Indicator: (a): P-20 Model 6.86 m l = 0.00686 or 6.86 x 10-3 ml (b): P-200 Model 132.4 m l = 0.1324 or 1.324 x 10-1 ml (c): P-1000 Model 262 m l= 0.262 or 2.62 x 10-1 ml

Operating the Micropipette Step 3: Attach the disposable tip Tip boxes are labeled for the range of barrel they accommodate (there are some manufacturer-specific types so check if you are mixing and matching). Center the end of the barrel in the tip and tap straight down, gently, twice. Attaching the disposable tip Some tips include a filter barrier mostly used for PCR reactions.

Operating the Micropipette Step 4: Depress the Plunger to the First Stop Depress the plunger first: don t put the tip in the liquid and then depress the plunger (the pressure is different). Step 5: Immerse Tip in Sample The tip must be below the surface of the liquid throughout the process of pulling up the liquid. Ideally the pipette is held vertically. To aspirate the sample into the tip, allow the pushbutton to return slowly and smoothly to the fully extended starting position. Step 6: Pause NEVER LET THE PLUNGER SNAP UP! Leave the tip in the solution for 1-2 sec (longer for a viscous solution), then slowly withdraw.

Operating the Micropipette Step 6: Withdraw the tip from the solution Withdraw the pipet from the receiving vessel carefully, touching or sliding the tip along the wall of the vessel. Note you should be wearing gloves no bare hands!

Operating the Micropipette Remove the tip from the sample liquid. There should not be liquid on the outside of the tip if you have used it correctly generally we do NOT touch the tip with anything. Some reagent containers may not allow ideal practice in that case wipe away any droplets on the outside of the tip with a lint-free tissue, such as KIMWIPES. Don t touch the tip opening or you will wick away some of the sample. Note on the left that the volume is not correct (air at bottom). Step 7: Withdraw the Tip No Gloves = bad Kimwipe not recommended usually. Air bubble = bad Proper Droplet Removal WRONG Droplet Removal Note you should be wearing gloves no bare hands!

Operating the Micropipette Step 8: Dispensing the solution to a tube (a) Start Dispensing (b) 1st Stop = Dispense (c) 2nd Stop = Expel a) Touch the tip end to the bottom or side wall of the receiving vessel b) Depress the plunger slowly to the FIRST STOP. c) Pause for at least one second, longer for larger volumes or viscous liquids. d) Press the plunger to the SECOND STOP (the second point, of greater resistance, at the bottom of the stroke) to expel any residual liquid in the tip an air bubble should force out the last drop of liquid.

Operating the Micropipette Step 9: Use the ejector button to eject the tip into a waste container (use a Biohazard can if you are directed, otherwise an empty tip box works pretty well).

First Lab: Pipetting Skills A set of pipette pumps. Serological pipettes, micropipetters and tips Several capped solution containers (colored water why?, then glycerol why?) Parafilm squares and small weigh boats Mass balances (2 levels why?)

Checking the volume If you know the density (mass per volume) of the liquid you are pipetting, and you have a calibrated mass balance, You can pipette a specified volume into a pre-weighed (tared) container and determine the mass of the volume added Why use water to check your pipetting? At 20 C, H 2 O has density as shown: 1ml = 0.9985 gm 1ul = 0.00099 gm = 0. 99ug A very close approximation of 1ug to 1ul Weller UNCC

Using the Balance Pick the right balance: does it go to a small enough amount (you need micrograms for most of the lab)? Close the glass doors: Air currents can change the reading on a very sensitive balance. Make sure you know where the Tare (Zero) control is.

Using Parafilm or weigh boats Parafilm for volumes < 1ml Use a weigh boat for volumes > 1ml Aqueous solutions bead up on Parafilm you can leave the backing paper on, but pipette solution onto the waxy side not the paper side. After weighing the volume, blot it up from the Parafilm with a Kimwipe, re-tare and repeat the pipetting.

Accuracy and Precision Accuracy means the closeness with which the dispensed volume approximates the volume set on the pipette The level of accuracy is specified as mean error, the average deviation of replicate measurements from what is expected from the volume you set. Precision is the "scatter" or variance of individual measurements obtained from the same volume setting. Precision can also be expressed as standard deviation (variance divided by the mean).

Accuracy and Precision (Continued) Device capabilities: relative accuracies are generally about 1% or less for micropipetters within range These micropipettors have recently been calibrated. Precision error is less than 0.5 % except when transferring the smallest recommended volume for a given pipette model Using the pipettes to transfer volumes which are below the recommended range will introduce larger errors

Lab Practice with Pipettes Practice setting a few volumes Practice reading the digits of set volumes Practice seating the tip, drawing up and dispensing samples of water and of a glycerol solution (glycerol is denser and more viscous). Get the "feel" of the 1 st (set volume to pull up ) and 2 nd (blow-out for delivery) stops Practice using the pipette and record how well measurements match settings (indirectly, your skill).