Instructions for use. RONDOflex plus Always be on the safe side.

Similar documents
Instructions for use INTRA LUX motor K REF INTRA LUX motor K 200 F - REF

O P E R A T O R S M A N U A L

Instructions for use Compressed air injector with water trap

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Operating and maintenance manual Filter and reducing station Series / 1.0

Ritter AquaBottleSystem

DECLARATION OF CE CONFORMITY DECLARATION OF CE CONFORMITY

MONT BLANC 10400X XL XLED 10401X XL XLED 10403X XL XLED

1. CONDITIONS FOR USE 2. SAFETY

Instruction Manual for Configura Cushionair Portable Pump

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Prestige Endoscopic Graspers Instructions for Use

User s Guide. VetPro 5000 Wall / Cabinet & Table Mount Dental Delivery System. For Models: Rev L (11/10/15)

Cavitron DualSelect. Introduction ENGLISH. Directions For Use. Cavitron DualSelect Dispensing System ENGLISH 1

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Operating Instructions - Rescue Equipment. RAM Support LRS-T EN Edition (translation of the original operating instructions)

Siphon vessel / Priming aid

Instruction Manual. ErgoLAP BIPOLAR

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Roofing Primer. Primer 610 Spray PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Primer for use with S-Vap 7000 E DP & Decostik SP

TABLE OF CONTENTS. INTRODUCTION to the AirVAC... 2 SAFETY INFORMATION... 3 DIMENSIONS & SPECIFICATIONS... 5 UNIT OVERVIEW... 6

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Type BBS-03, BBS-05, BBS-06, BBS-25

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

ROPV R40 E Series User Manual

OWNER S MANUAL SUCTION GUN SG-300

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

AND OPERATION INSTRUCTIONS

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Yoke Block Instruction Manual

Oxygen Dialflow Meter. Instructions for Use

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Roofing Adhesive PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Insulation Adhesive for Sarnafil Roofing Systems

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Yoke Block Instruction Manual

Operating Instructions. ATMOS Chair Comfort. English GA1GB Index 01

ST 18 Aluminium Gas Model

OWNER S MANUAL. Page: 1 of 8

ST 18 Aluminium Gas Model

Technical Data Sheet PART A & PART B

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

Corning Step-R. Repeating Pipettor. Instruction Manual

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

neska High-Speed Handpiece P320

OPERATION INSTRUCTIONS

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

Pressure maintenance valve SDV-P / SDV-P-E

Checklist for care of Respirators

Instruction Manual / Glide. Richie Vas / Maxum Team MMA Bantamweight Champion & Big Wave Surfer

Fingertip Pulse Oximeter

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Operating instructions Automatic spray gun A15 eco. T-Dok-665-GB-Rev Translation of the original operating instructions

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

Model ASSEMBLY and OPERATING INSTRUCTIONS

REMS Swing INSTRUCTION MANUAL SINGLE-HAND TUBE BENDER SWING ANCRA

RayPette Plus Autoclavable Pipette. User Manual

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Sterile Visual Flow Indicator

Inflatable Stand Up Paddle Board Manual

max 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de Cadência Kadencesensor

Frigitronics CRYO-PLUS

ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO PORTUGUÊS

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

B.C.D. Buoyancy Compensator Device User Manual

Versatile, user friendly all glass sliding revolving door w26-c Maintenance Instructions and Directions for Use

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Notes Before Use...2 Notes on charging your watch...2. Your Watch...4 Name of Components...6 About the crown...7

air/hydraulic nut riveter heavy-duty vacuum system

AMBLER SURGICAL INSTRUCTIONS FOR USE - OPHTHALMIC DUET-STYLE SCISSORS

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

English USER GUIDE User guide

WARNING! Equipment for treatment of water intended for human consumption (Directive 98/83 CE).

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

Flexi-pro Aerosol Delivery System (FADS) Manual

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Assembling & Installing your Pool Cleaner

Instrument Operating Manual

The pipettes cover a volume range from 0.1µl to 10ml.

Read where you love to read the pool, the tub, or the beach with the waterproof Guardian Case for Kindle!

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

AS/NZS 1801 USE AND CARE BOOKLET OCCUPATIONAL PROTECTIVE HELMET

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

Work Smarter...Not Harder!

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

FLANGED TWO-PIECE BALL VALVES

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Transcription:

Instructions for use RONDOflex plus 360-1.002.2179 Always be on the safe side.

Distributed by: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Phone +49 7351 56-0 Fax +49 7351 56-1488 Manufacturer: Kaltenbach & Voigt GmbH Bismarckring 39 D-88400 Biberach www.kavo.com

Contents Contents 1 User instructions... 4 2 Safety... 5 2.1 Description of safety instructions... 5 2.2 Safety instructions... 5 3 Product description... 7 3.1 Purpose Intended use... 7 3.2 Technical data... 8 3.3 Transportation and storage conditions... 8 4 Start up and shut down... 9 4.1 Connecting to devices... 9 4.2 Mounting the MULTIflex (LUX) / MULTIflex LED coupling... 9 4.3 Checking the pressures... 9 4.4 Check O-rings... 9 5 Operation... 10 5.1 Attaching the medical device... 10 5.2 Removing the medical device... 10 5.3 Filling the powder container... 10 5.4 Inserting the cannula... 10 5.5 Removing the cannulas... 11 5.6 Notes for application... 11 6 Troubleshooting... 13 7 Reprocessing methods according to ISO 17664... 14 7.1 Preparation at the site of use... 14 7.2 Cleaning... 14 7.2.1 Manual external cleaning... 14 7.2.2 Automated external cleaning... 14 7.2.3 Manual internal cleaning... 15 7.2.4 Automated internal cleaning... 15 7.2.5 Cleaning the cannulas... 15 7.3 Disinfection... 16 7.3.1 Manual external disinfection... 16 7.3.2 Manual internal disinfection... 16 7.3.3 Automated external and internal disinfection... 16 7.4 Drying... 16 7.5 Care products and systems - Servicing... 17 7.6 Packaging... 17 7.7 Sterilisation... 17 7.8 Storage... 17 8 Tools and consumables... 19 9 Terms and conditions of warranty... 20 3 / 22

1 User instructions 1 User instructions Dear User Congratulations on purchasing this KaVo quality product. By following the instructions below you will be able to work smoothly, economically and safely. Copyright by KaVo Dental GmbH Symbols Refer to the chapter on Safety/Warning symbol Important information for users and service technicians Can be steam-sterilised at 134 o C -1 o C / +4 o C (273 o F -1.6 o F / +7.4 o F) Thermodisinfectable CE-Zeichen (Communauté Européenne). Ein Produkt mit diesem Zeichen entspricht den Anforderungen der anwendbaren EG-Richtlinie. Action request Target group This document is intended for dentists and their assistants. The section on starting up is also intended for service technicians. 4 / 22

2 Safety 2.1 Description of safety instructions 2 Safety 2.1 Description of safety instructions Warning symbol Structure DANGER The introduction describes the type and source of the hazard. This section describes potential consequences of non-compliance. The optional step includes necessary measures for hazard prevention. Description of hazard levels The safety instructions listed here, together with the three levels of danger will help avert property damage and injury. indicates a hazardous situation that can cause damage to property or mild to moderate injuries. WARNING WARNING indicates a hazardous situation that can lead to serious or fatal injury. DANGER DANGER indicates a maximal hazard due to a situation that can directly cause death or fatal injury. 2.2 Safety instructions WARNING Hazard to the care provider and patient. If product irregularities occur. Stop working and contact service support. Hazard from aerosols. Infection from aerosols. Never work without safety goggles, a dust mask (P 2), protective gloves, particleimpervious clothes and a hood. KaVo recommends working with a dental dam and a dust extraction system. 5 / 22

2 Safety 2.2 Safety instructions Hazard of air embolism and skin emphysema. There is a danger that the insufflation of spray in open wounds in the surgical area can cause air embolisms and skin emphysema. Avoid the insufflation of spray in open wounds in surgical area! Premature wear and malfunctioning from improper storage during long periods of nonuse. Reduced product life. The medical device should be cleaned, serviced and stored in a dry location, according to instructions, before long periods of nonuse. Safety checks since cleansers and disinfectants can attack the plastic housing. This can cause hairline cracks and other damage to arise which can lead to a hazardous situation. The RONDOflex plus therefore has to undergo a safety check every 2 years. Send the RONDOflex plus to the KaVo Customer Service Centre Warthausen or a test centre approved by KaVo. Note Never use the RONDOflex plus on patients with chronic diseases of the respiratory passages. Note It is easiest to remove fine powder deposits with a vacuum cleaner. Wiping them off with a cloth can easily cause scratches in sensitive surfaces. Rinse parts insensitive to moisture under flowing water to remove residual powder. The following individuals are authorized to repair and service KaVo products: Technicians at KaVo branches throughout the world Technicians specially trained by KaVo 6 / 22

3 Product description 3.1 Purpose Intended use 3 Product description RONDOflex plus 360 (Mat. no. 1.002.2179) 3.1 Purpose Intended use Indications for use: This medical device is only for dental treatment by a dental professional. The product may not be changed or used for any other purpose since this may be hazardous. The RONODflex plus is an air abrasion system that accelerates aluminium oxide particles in an air jet to a high speed to abrade material from the surface of teeth. A medical device according to relevant national statutory regulations. The RONDOflex plus is suitable for the following indications: Preparation for sealing fissures Opening and expanding fissures Creating micromechanical retention for adhesive restorations to the enamel and dentin with a subsequent acid etching technique Preparing small carious defects Preparing the adhesive surfaces of brackets Cleaning and removing residual adhesive from bridges, crowns, etc. (extraoral) Proper use: According to these regulations, this medical device may only be used for the described application by a knowledgeable user. You need to comply with the following: the applicable health and safety regulations the applicable accident prevention regulations these Instructions for use According to these regulations, the user is required to: only use equipment that is operating correctly, adhere to the specified intended use protect him or herself, the patient and third parties from danger, and avoid contamination from the product. 7 / 22

3 Product description 3.2 Technical data 3.2 Technical data Drive pressure Water pressure Air consumption 3.2-6.0 bar (46-87 psi) 1.5 ± 0.1 bar (22 ± 1 psi) 5-11 Nl/min depending on the type of cannula Water quantity 35-45 ml/min. Attachable to all MULTIflex (LUX) / MULTIflex LED couplings. Note The pressure set for the turbine drive is automatically increased by 20%, from 2.8 to 3.2 bar (41 to 46 psi). Note Have a service technician regularly check the manufacturer's recommended pressures for your treatment centre to ensure that the handpiece works properly. 3.3 Transportation and storage conditions It is hazardous to start up the medical device after it has been stored strongly refrigerated. This can cause the medical device to malfunction. Prior to start-up, very cold products must be heated to a temperature of 20 o C to 25 o C (68 o F to 77 o F). Temperature: -20 C to +70 C (-4 F to +158 F) Relative humidity: 5% RH to 95% RH absence of condensation Air pressure: 700 hpa to 1060 hpa (10 psi to 15 psi) Protect from moisture 8 / 22

4 Start up and shut down 4.1 Connecting to devices 4 Start up and shut down WARNING Hazard from non-sterile products. Infection hazard for care provider and patient. Before first use and after each use, prepare and sterilise the medical device and accessories accordingly. WARNING Disposal of the product in the appropriate manner. Prior to disposal, the product and accessories must be appropriately prepared or sterilised if this is necessary. 4.1 Connecting to devices Damage from contaminated and moist cooling air. Contaminated and moist cooling air can cause malfunctions. Make sure that the supply of cooling air is dry, clean, and uncontaminated according to EN ISO 7494-2. 4.2 Mounting the MULTIflex (LUX) / MULTIflex LED coupling Screw the MULTIflex (LUX) / MULTIflex LED coupling onto the turbine hose and tighten with the wrench. 4.3 Checking the pressures Compressed air connection on devices. Contaminated and humid compressed air leads to premature wear and tear. Ensure that the cooling air is dry, clean and uncontaminated in accordance with EN ISO 7494-2. A drive pressure of 3.2 bar (46 psi) is required for operating the RONDOflex. Place the test manometer (Mat. No. 0.411.8731) between the MULTIflex (LUX) / MULTIflex LED coupling and RONDOflex and check the following pressures: ð - Drive air: 3.2-6.0 bar (46-87 psi) ð - Water: 1.5 ± 0.1 bar (22 ± 1 psi) 4.4 Check O-rings Missing or damaged O-rings. Malfunctions and premature failure. Make sure that all O-rings are on the coupling and undamaged. Number of available O-rings: 5 9 / 22

5 Operation 5.1 Attaching the medical device 5 Operation 5.1 Attaching the medical device Note Pull on the RONDOflex plus to check its seat on the MULTIflex (LUX) / MULTIflex LED coupling. Position the RONDOflex plus precisely on the MULTIflex coupling and push it to the back until it audibly locks into place. 5.2 Removing the medical device Grasp the MULTIflex (LUX) / MULTIflex LED coupling, and pull the RONDOflex plus off towards the front, twisting it slightly. 5.3 Filling the powder container Unscrew the powder container to the left against the direction of the arrow. Fill the powder container half way with RONDOflex powder (20 g). Screw on the powder container straight on to the right in the direction of the arrow. Close the powder container if it is not needed. If you do not need the powder container, close it with the rubber cover. Only use original KaVo RONDOflex powder. Note Observe the safety data sheet for the RONDOflex 2013 powder 50 µm or 27 µm! This can be read under www.kavo.com, Safety data sheets". 5.4 Inserting the cannula Before inserting the cannula, blow out the receiving hole with compressed air. Insert the cannula into the handpiece, and turn it all the way to the right with the key opposite the direction of the arrow. 10 / 22

5 Operation 5.5 Removing the cannulas The markings must coincide; otherwise the cannula can detach. If the adaptor detaches during treatment, it can give rise to a substantially hazard for the patient and user. Pull on the adaptor before each treatment and check if it is seated firmly. Before each treatment, make sure that the adaptor works properly. 5.5 Removing the cannulas Turn the cannula with the key all the way to the left in the direction of the arrow, and remove it. 5.6 Notes for application For practicing with the RONDOflex plus, produce a cavity on a disposable mirror to familiarise yourself with the handpiece. Note KaVo recommends to use a disposable mirror during treatment. To create cavities Focus on a spot. Improve the abrasion performance with an intermittent powder jet. Keep a working distance of 1 mm. Hold the powder jet perpendicular to the surface of the tooth. To roughen surfaces, for example adhesive surfaces of brackets Work with brush-like strokes. Keep a distance of 1 mm. Hold the powder jet perpendicular to the surface of the tooth. Extraoral use The RONDOflex plus can also be used outside of the oral cavity, e.g. in order to remove residual adhesive from crowns. If you work outside of the oral cavity, please remember that powder dust is being generated around the working field. The powder dust may impair the function of devices/ handpieces situated in the vicinity. 11 / 22

5 Operation 5.6 Notes for application Provide for adequate suction. Objects that may contact the powder jet should be covered with a cloth to protect the surface from damage. If necessary, remove dust-sensitive objects from the respective environment. 12 / 22

6 Troubleshooting Possible application errors: The distance to the tooth surface is too large "Painting" with the tip during the preparation of cavities Instructions for use RONDOflex plus 360-1.002.2179 6 Troubleshooting 5.6 Notes for application The caries lesions are too large since the kinetic energy of the powder particles is lost due to the soft caries material Insufficient quantity of powder in the container (must be filled at least 20 %) Low drive pressure 13 / 22

7 Reprocessing methods according to ISO 17664 7.1 Preparation at the site of use 7 Reprocessing methods according to ISO 17664 7.1 Preparation at the site of use WARNING Hazard from nonsterile products. There is a risk of infection from contaminated medical devices. Take suitable personal protective measures. Remove all residual cement, composite or blood without delay. Reprocess the medical device as soon as possible after treatment. The medical device must be dry when transported for reconditioning. Do not place it in a solution or similar. Remove the insert from the medical device. 7.2 Cleaning Malfunctions from cleaning in the ultrasonic unit. Defects in the product. Only clean manually or in a thermodisinfector. Malfunction from cleaning with oils or maintenance spray. Defective product. Do not clean the medical device with oils or maintenance of spray. 7.2.1 Manual external cleaning Accessories required: Tap water 30 o C ± 5 o C (86 o F ± 10 o F) Brush, e.g. medium-hard toothbrush Brush off under flowing tap water. 7.2.2 Automated external cleaning KaVo recommends thermodisinfectors in accordance with EN ISO 15883-1, which are operated with alkaline cleaning agents with a ph value of max. 10 (e.g. Miele G 7781/G 7881 Validation was carried out with Programme "VARIO-TD", cleaning agent "neodisher mediclean", neutralisation agent "neodisher Z" and rinsing agent "neodisher mielclear" and only applies to the material compatibility with KaVo products). For program settings as well as cleansers and disinfectants to be used, please refer to the Instructions for Use of the thermodisinfector (complying with max. ph value of 10). In order to prevent impairment of the KaVo medical device, make sure that the inside and outside of the device is dry after the end of the cycle. 14 / 22

7.2.3 Manual internal cleaning Instructions for use RONDOflex plus 360-1.002.2179 7 Reprocessing methods according to ISO 17664 7.2 Cleaning Note Remove the cannula prior to the manual internal cleaning! Can only be done with KaVo CLEANspray or KaVo DRYspray. Cover the medical device with the KaVo CLEANpac bag, and place it on the corresponding care adapter. Press the spray button three times for 2 seconds each time. Remove the medical device from the spray attachment and let the cleaner work for one minute. Afterwards, rinse for 3-5 seconds with KaVo DRYspray. See also: 2 KaVo CLEANspray / KaVo DRYspray Instructions for Use Note KaVo CLEANspray and KaVo DRYspray for manual interior cleaning are only available in the following countries: Germany, Austria, Switzerland, Italy, Spain, Portugal, France, Luxembourg, Belgium, Netherlands, United Kingdom, Denmark, Sweden, Finland and Norway. In other countries interior cleaning can only be carried out with thermodisinfectors in accordance with EN ISO 15883-1. 7.2.4 Automated internal cleaning KaVo recommends thermodisinfectors in accordance with EN ISO 15883-1, which are operated with alkaline cleaning agents with a ph value of max. 10 (e.g. Miele G 7781/G 7881 Validation was carried out with Programme "VARIO-TD", cleaning agent "neodisher mediclean", neutralisation agent "neodisher Z" and rinsing agent "neodisher mielclear" and only applies to the material compatibility with KaVo products). For program settings as well as cleansers and disinfectants to be used, please refer to the Instructions for Use of the thermodisinfector (complying with max. ph value of 10). In order to prevent impairment of the KaVo medical device, make sure that the inside and outside of the device is dry after the end of the cycle. 7.2.5 Cleaning the cannulas Remove the cannulas. Twist the nozzle needle from the front and then from the back into the cannula. Remove the nozzle needle, and blow out the cannula with compressed air. or Remove the cannula and rinse it with tap water. 15 / 22

7 Reprocessing methods according to ISO 17664 7.3 Disinfection 7.3 Disinfection Malfunctioning from using a disinfectant bath or disinfectant containing chlorine. Defects in the product. Only disinfect in a thermodisinfector or manually. 7.3.1 Manual external disinfection KaVo recommends the following products based on material compatibility. The microbiological efficacy must be ensured by the disinfectant manufacturer. Mikrozid AF made by Schülke & Mayr (liquid or cloths) FD 322 made by Dürr CaviCide made by Metrex Consumables required: Cloths for wiping off the medical device. Spray the disinfectant on a cloth, then wipe down the medical device and allow the disinfectant to act according to the instructions of the disinfectant manufacturer. Follow the instructions for use of the disinfectant. 7.3.2 Manual internal disinfection The efficacy of manual internal disinfection must be demonstrated by the manufacturer of the disinfection agent. With KaVo products, use only disinfection agents that have been released by KaVo with respect to the compatibility of materials (e.g. WLcid / made by ALPRO). Follow the instructions for use of the disinfectant. 7.3.3 Automated external and internal disinfection KaVo recommends thermodisinfectors in accordance with EN ISO 15883-1, which are operated with alkaline cleaning agents with a ph value of max. 10 (e.g. Miele G 7781/G 7881 Validation was carried out with Programme "VARIO-TD", cleaning agent "neodisher mediclean", neutralisation agent "neodisher Z" and rinsing agent "neodisher mielclear" and only applies to the material compatibility with KaVo products). For program settings as well as cleansers and disinfectants to be used, please refer to the Instructions for Use of the thermodisinfector (complying with max. ph value of 10). In order to prevent impairment of the KaVo medical device, make sure that the inside and outside of the device is dry after the end of the cycle. 7.4 Drying Manual Drying Blow off the outside and inside with compressed air until water drops are no longer visible. 16 / 22

7 Reprocessing methods according to ISO 17664 7.5 Care products and systems - Servicing Automatic Drying The drying procedure is normally part of the disinfection program of the thermodisinfector. Follow the instructions for use of the thermodisinfector. 7.5 Care products and systems - Servicing Insufficient product care. This can cause damage and malfunction. Before each thermodisinfection or sterilisation, unscrew the powder container, empty it and thermodisinfect or sterilise it together with the handpiece. Likewise, clean off any powder residue on the RONDOflex, especially the cannula, tubes, and powder nozzle. 7.6 Packaging Note The sterilisation bag must be large enough for the handpiece so that the bag is not stretched. The quality and use of the sterilisation packaging must satisfy applicable standards and be suitable for the sterilisation procedure! Individually seal the medical device in the sterilised item packaging. 7.7 Sterilisation Sterilisation in a steam steriliser (autoclave) in accordance with EN 13060 / ISO 17665-1 Contact corrosion due to moisture. Damage to product. Immediately remove the product from the steam steriliser after the sterilisation cycle! The KaVo medical device has a maximum temperature resistance of up to 138 (280.4 F). Select a suitable procedure (depending on the available autoclave) from the following sterilisation processes: Autoclave with three times pre-vacuum: - at least 3 minutes at 134 C -1 C / +4 C (273 F -1.6 F / +7.4 F) Autoclave using the gravity method: - at least 10 minutes at 134 C -1 C / +4 C (273 F -1.6 F / +7.4 F) Use according to the manufacturer's Instructions for Use. 7.8 Storage Reprocessed products should be stored protected from dust with minimum exposure to germs in a dry, dark and cool space. 17 / 22

7 Reprocessing methods according to ISO 17664 7.8 Storage Comply with the expiry date of the sterilised items. 18 / 22

8 Tools and consumables 7.8 Storage 8 Tools and consumables 1 set consists of Available from dental suppliers. Name Mat. no. cannula 110 o - 0.64 mm 1.002.6251 cannula 110 o - 0.46 mm 1.002.9176 Wrench 1.002.6250 Powder container 27 μm 1.003.1235 Rubber cover 1.000.2678 Powder 27 μm 1000 g 1.000.5957 Powder 50 μm 1000 g 1.000.5956 Cleaning drill 1.001.3602 Nozzle tube 1.002.9920 Further tools and consumables Name Mat. no. cannula 90 o - 0.46 mm 1.002.9182 cannula 90 o - 0.64 mm 1.002.9179 O-ring for cannulas 0.200.6019 Powder container 50 μm 1.003.1236 Container seal 0.573.6072 19 / 22

9 Terms and conditions of warranty 7.8 Storage 9 Terms and conditions of warranty The following warranty conditions apply to this KaVo medical device: KaVo provides the end customer with a warranty of proper function and guarantees zero defects in respect of material and processing for a period of 12 months from the date of the invoice, subject to the following conditions: In case of justified complaints, KaVo will honour its warranty with a free replacement or repair. Other claims of any nature whatsoever, in particular with respect to compensation, are excluded. In the event of default, gross negligence or intent, this shall only apply in the absence of mandatory legal regulations to the contrary. KaVo shall not be liable for defects and their consequences that have arisen or may arise from natural wear, improper handling, cleaning or maintenance, non-compliance with operating, maintenance or connection instructions, calcination or corrosion, contaminated air or water supplies or chemical or electrical factors deemed abnormal or impermissible in accordance with KaVo's instructions for use or other manufacturer's instructions. The warranty granted does not usually extend to lamps, light conductors made of glass and glass fibres, glassware, rubber parts, and the colourfastness of plastic parts. All liability is excluded if defects or their consequences originate from manipulations or changes to the product made by the customer or a third party that is not authorised by KaVo. Warranty claims will only be accepted if the product is submitted along with proof of purchase in the form of a copy of the invoice or note of delivery. The dealer, purchase date, type, and serial number must be clearly evident from this document. 20 / 22

1.002.6681 kb 20120706-04 en