AirFit Nasal Mask. User guide N10. English

Similar documents
Mirage FX. User Guide. English NASAL MASK

User guide English r1 Quattro Air Amer Multi Multi Book.indb 1 14/07/ :30:10 AM

Fitting / Mise en place / Colocación / Ajuste

Fitting / Mise en place / Colocación / Ajuste

Swift LT NASAL PILLOWS SYSTEM. User Guide English

User Guide. English. Nasal Pillows System

English USER GUIDE User guide

Mirage Micro. User Guide. English. nasal mask

User Guide. English. Nasal Pillows System

Quattro Air Non-vented full face mask

Nasal mask. User guide. User guide English

English USER GUIDE User guide

Swift FX Nano Swift FX Nano for Her

Mirage FX. User Guide. English NASAL MASK

Full face mask. User guide English

Mirage Micro for Kids. nasal mask

Full face mask. User guide. English

Mirage Vista Nasal Mask

Quattro FX Quattro FX for Her

Mirage Micro for Kids

Mirage FX. User Guide. English NASAL MASK

Mirage Micro. User Guide. English. nasal mask

AirFit Nasal Mask. User guide N10. English

English. ivolve Full Face Mask. User Manual

Swift FX Bella. User Guide. + Swift FX for Her HEADGEAR NASAL PILLOWS SYSTEM

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

Mirage Quattro FULL FACE MASK

EasyLife INSTRUCTIONS FOR USE. Respironics Inc Murry Ridge Lane Murrysville, PA USA JDH 3/25/10

Hospital masks. User guide. English

Mirage Quattro FULL FACE MASK

Swift FX Nano Swift FX Nano for Her

Mirage Liberty. User Guide 61850/ APAC ENG MIRAGE LIBERTY USER r2 cover.qxp 3/04/2007 4:39 PM Page 1. English FULL FACE MASK

Mirage FX. User Guide. English NASAL MASK

Instructions for Use. OptiLife Nasal Lab Mask

User guide English book.indb 1 14/07/ :51:19 AM

Quattro FX Quattro FX for Her

2010 Koninklijke Philips Electronics N.V. All rights reserved. INSTRUCTIONS FOR USE

Invacare Twilight II Nasal Mask

Full face mask. User guide. English

ComfortGel Full. Full Face Mask

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Pixi. User Guide. Pixi TM PEDIATRIC MASK. English. pediatric MASK

Full face benefits in a compact size

Mirage Activa LT. User Guide. English. nasal mask

Ultra Mirage II Nasal Mask

EasyFit SilkGel Full Face Mask

Log on now to to find useful tips on managing your treatment. Mirage Swift II. Nasal Pillows System. User Guide.

Please read the entire Information and Welcome Guides before using your device.

EasyFit Full Face Mask, Silicone EasyFit Full Face Mask, Gel

Mirage Kidsta Nasal Mask

English Please read the entire Information and Welcome Guides before using your device.

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

English Please read the entire Information and Welcome Guides before using your device.

Full face mask. QuietAir. User guide. English

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Full face mask. User guide. English Deutsch Français Italiano العربیةاللغة Nederlands

S8 Lightweight II. User Guide. English POSITIVE AIRWAY PRESSURE DEVICE

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Nasal mask. User guide. English Deutsch Français Italiano العربیةاللغة Nederlands

Micro Dial-Flowmeter. Instructions for Use

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Contents Warnings, Cautions, and Notes Contents of the Package Introduction to the Harmony S/T A Tour of the Harmony S/T...

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

S8 Series II. S8 AutoSet Spirit II S8 AutoScore II. User Guide. English POSITIVE AIRWAY PRESSURE DEVICES

Rev. B. Operating Instructions

OPERATOR S MANUAL. Pediatric/Infant cap-one Mask YG-232T/YG-242T A. General. Safety Information WARNING WARNING WARNING. Components WARNING

Oxygen Dialflow Meter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use

Pressure Regulator. Instructions for Use

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

Dialflow Regulator. Instructions for Use

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

This mask changes everything

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

User guide User guide English

Model 1700 Patient Operating Instructions. Model 1700

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

User guide User guide English

SOTR Special Operations Tactical Respirator

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Owner s Manual. Model H4685

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Paradise Pump Series Operator s Manual

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

CPR MEDICAL DEVICES INC. OPERATING MANUAL

Pressure Injection Cell Operator s Manual

ATEX ATEX

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

M5400 Operators Manual

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Oxygen Demand Valve. Instructions for Use

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Model ASSEMBLY and OPERATING INSTRUCTIONS

Copyright Trek Bicycle Corporation 2005 All rights reserved

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device.

Mirage Liberty. User Guide. English FULL FACE MASK

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

Portable Massage Table User Manual

Transcription:

AirFit Nasal Mask N10 User guide English

Fitting / Mise en place / Colocación / Ajuste 1 2 3 4 5 6 7

Removal / Retrait / Remoción / Remoção 1 2 Disassembly / Démontage / Desmontaje / Desmontagem 1 2 3

Reassembly / Remontage / Montaje / Remontagem 1 2 3 4

ENGLISH Nasal Mask Thank you for choosing the AirFit N10. This document provides the user instructions for the AirFit N10 and AirFit N10 for Her masks referred to collectively as AirFit N10 throughout this manual. AirFit N10 has blue headgear while AirFit N10 for Her has pink headgear. Using this guide Please read the entire guide before use. When following instructions, refer to the images at the front and back of the guide. Intended Use The AirFit N10 channels airflow noninvasively to a patient from a positive airway pressure (PAP) device such as a continuous positive airway pressure (CPAP) or bilevel device. The AirFit N10 is: to be used by patients (> 66 lb (30 kg)) for whom positive airway pressure has been prescribed intended for single-patient re-use in the home environment and multipatient re-use in the hospital/institutional environment. WARNING Magnets used in this mask are within ICNIRP guidelines for general public use. Some active medical implants such as a pacemaker or defibrillator may be affected by localized magnetic fields. The magnetic clips in this mask should be kept at least 2 in. (50 mm) away from any active medical implant. English 1

Contraindications Use of the AirFit N10 may be contraindicated in some patients with the following pre-existing conditions: a metallic hemostatic clip implanted in your head to repair an aneurysm metallic splinters in one or both eyes following a penetrating eye injury. GENERAL WARNINGS The vent holes must be kept clear. The mask should only be used with CPAP or bilevel devices recommended by a physician or respiratory therapist. The mask should not be used unless the device is turned on. Once the mask is fitted, ensure the device is blowing air. Explanation: CPAP and bilevel devices are intended to be used with special masks (or connectors) which have vent holes to allow continuous flow of air out of the mask. When the device is turned on and functioning properly, new air from the device flushes the exhaled air out through the mask vent holes. However, when the device is not operating, insufficient fresh air will be provided through the mask, and the exhaled air may be rebreathed. Rebreathing of exhaled air for longer than several minutes can, in some circumstances, lead to suffocation. This applies to most models of CPAP or bilevel devices. Follow all precautions when using supplemental oxygen. Oxygen flow must be turned off when the CPAP or bilevel device is not operating, so that unused oxygen does not accumulate within the device enclosure and create a risk of fire. Oxygen supports combustion. Oxygen must not be used while smoking or in the presence of an open flame. Only use oxygen in well ventilated rooms. At a fixed rate of supplemental oxygen flow, the inhaled oxygen concentration varies, depending on the pressure settings, patient breathing pattern, mask, point of application and leak rate. This warning applies to most types of CPAP or bilevel devices. 2

The technical specifications of the mask are provided for your clinician to check that they are compatible with the CPAP or bilevel device. If used outside specification or if used with incompatible devices, the seal and comfort of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect the CPAP or bilevel device function. Discontinue using this mask if you have ANY adverse reaction to the use of the mask, and consult your physician or sleep therapist. Using a mask may cause tooth, gum or jaw soreness or aggravate an existing dental condition. If symptoms occur, consult your physician or dentist. As with all masks, some rebreathing may occur at low CPAP pressures. Refer to your CPAP or bilevel device manual for details on settings and operational information. Remove all packaging before using the mask. Using your mask When using your mask with ResMed CPAP or bilevel devices that have mask setting options, refer to the Technical specifications section in this user guide for mask selection options. For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on www.resmed.com on the Products page under Service & Support. If you do not have internet access, please contact your ResMed representative. Fitting 1. With the gray side of the headgear facing outward and with both lower headgear straps released, align the bottom of the cushion opening with the bottom of your nose. 2. Place the mask over your nose. Hold the mask against your face and pull the headgear over your head. Headgear check: Ensure the label on the headgear faces outwards when the headgear is put on. 3. Bring the lower straps below your ears. Attach the magnet clip to the outside of the frame. English 3

4. Undo the fastening tabs on the upper headgear straps. Adjust the straps evenly until the mask sits comfortably just under the nose. Reattach the fastening tabs to the upper headgear straps. 5. Undo the fastening tabs on the lower headgear straps. Adjust the straps evenly until the mask is stable. Reattach the fastening tabs. 6. Connect the free end of the short tube assembly to the device air tubing. Turn on your device so that it is blowing air. 7. Adjust the cushion and headgear until the mask sits comfortably on your nose and is not creased or twisted. Notes: The upper straps are the key adjustments for seal and comfort. Ensure they are not overtightened. The lower straps are used to keep the cushion in the right position. They do not need to be tightened much for the mask to fit comfortably. Removing your mask 1. Remove one or both magnets from the frame by twisting the lower headgear strap and clip away. 2. Pull the mask away from your face and back over your head. Disassembly 1. Undo the fastening tabs on the upper headgear straps. Pull the straps out of the frame. 2. Squeeze and pull the cushion away from the frame. 3. If the soft sleeves are fitted, remove them by pulling them off of the frame. Reassembly 1. Attach the cushion to the frame by inserting the top and bottom clips into the correct slots on the frame. 2. To fit the optional soft sleeves, pull them over the upper arms of the frame. 3. With the ResMed logo facing out, thread the top headgear straps into the frame slots from the inside out. Fold the strap over to secure. 4. To reattach the magnet clips to the headgear, thread the lower headgear straps into the slots with the clips facing down. Fold the strap over to secure. 4

Cleaning your mask in your home Your mask and headgear should only be handwashed by gently rubbing in warm (approximately 86 F/30 C) water using mild soap. All components should be rinsed well with drinking quality water and allowed to air dry out of direct sunlight. WARNING Always follow cleaning instructions and use mild soap. Some cleaning products may damage the mask, its parts and their function, or leave harmful residual vapours that could be inhaled if not rinsed thoroughly. CAUTION If any visible deterioration of a system component is apparent (cracking, crazing, tears etc), the component should be discarded and replaced. Daily/After each use: To optimize the mask seal, facial oils should be removed from the cushion after use. Handwash the separated mask components (excluding headgear and soft sleeves). If the vent or swivel requires cleaning, use a soft bristle brush. Weekly: Handwash the headgear and soft sleeves. The headgear may be washed without being disassembled. Reprocessing the mask between patients This mask should be reprocessed when used between patients. Cleaning, disinfection and sterilization instructions are available from the ResMed website, www.resmed.com/masks/sterilization/americas. If you do not have internet access, please contact your ResMed representative. English 5

Troubleshooting Problem/possible cause Mask is too noisy. Vent is blocked or partially blocked. Mask is incorrectly assembled. Mask is leaking. Mask leaks around face. Mask is not positioned correctly. Mask may have been fitted incorrectly. Cushion membrane is creased or folded. Mask is not tightened correctly. Mask may be the wrong size. Mask does not fit properly. Mask is incorrectly assembled. Mask may be the wrong size. Cushion may be dirty. Solution If the vent requires cleaning, use a soft bristle brush. Disassemble the mask, then reassemble according to the instructions. Refit or reposition your mask. Readjust the headgear straps to bring the mask closer to the face and improve your seal. Check that your mask is assembled correctly. Check that the ResMed logo is facing downward on the bottom of the cushion along the bottom of your nose. Pull the mask away from your face and reposition, ensuring that the lower corners of the mask fully enclose your nose. If necessary, readjust the headgear straps to keep the mask in the right place. Remove and refit your mask according to the fitting instructions. Ensure you position the cushion correctly over your nose before pulling the headgear over your head. Do not slide the mask down your face during fitting as this may lead to folding or curling of the cushion. Ensure that the headgear straps are not overtightened or too loose. You may find that this mask does not need to be tightened as much as other nasal masks. Check that the headgear is not twisted. Talk to your clinician. Disassemble the mask, then reassemble according to the instructions. Talk to your clinician. Clean cushion according to the instructions. 6

Technical specifications Pressure-flow curve Dead space information Therapy pressure Resistance Environmental conditions Gross dimensions Mask setting options The mask contains passive venting to protect against rebreathing. As a result of manufacturing variations, the vent flow rate may vary. Pressure (cm H2O) 4 20 8 29 11 35 12 37 16 43 17 44 20 49 22.5 53 24 54 30 61 Flow (L/min) Physical dead space is the empty volume of the mask to the end of the swivel. Using the wide cushions it is 104 ml. 4 to 30 cm H2O Drop in pressure measured (nominal) at 50 L/min: 0.4 cm H2O at 100 L/min: 1.2 cm H2O Operating temperature: +41 F to +104 F (+5 C to +40 C) Operating humidity: 15% to 95% non-condensing Storage and transport temperature: -4 F to +140 F (-20 C to +60 C) Storage and transport humidity: up to 95% non-condensing 19.0" (H) x 6.10" (W) x 4.33" (D) (483 mm (H) x 155 mm (W) x 110 mm (D)) Mask fully assembled with short tube assembly (no headgear) For S9: Select 'Pillows' For other devices: Select 'SWIFT' (if available), otherwise select 'MIRAGE' as the mask option. Notes: The mask system does not contain BPA, PVC, DEHP or phthalates. This product is not made with natural rubber latex. The manufacturer reserves the right to change these specifications without notice. English 7

Storage Ensure that the mask is thoroughly clean and dry before storing it for any length of time. Store the mask in a dry place out of direct sunlight. Disposal This mask does not contain any hazardous substances and may be disposed of with your normal household refuse. 8

Symbols The following symbols may appear on your product or packaging: Catalog number Batch code Humidity limitation Temperature limitation Fragile, handle with care Not made with natural rubber latex Manufacturer European Authorized Representative Keep away from rain This way up Indicates a Warning or Caution and alerts you to a possible injury or explains special measures for the safe and effective use of the device Caution, consult accompanying documents Prescription only (In the US, Federal law restricts these devices to sale by or on the order of a physician) English 9

Limited warranty ResMed Ltd (hereafter ResMed ) warrants that your ResMed mask system (including mask frame, cushion, headgear and tubing) shall be free from defects in material and workmanship from the date of purchase for the period of 90 days or in the case of disposable masks the maximum use period. This warranty is only available to the initial consumer. It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components. This limited warranty does not cover: a) any damage caused as a result of improper use, abuse, modification or alteration of the product; b) repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs; and c) any damage or contamination due to cigarette, pipe, cigar or other smoke. Warranty is void on product sold, or resold, outside the region of original purchase. Warranty claims on defective product must be made by the initial consumer at the point of purchase. This warranty replaces all other expressed or implied warranties, including any implied warranty of merchantability or fitness for a particular purpose. Some regions or states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from region to region. For further information on your warranty rights, contact your local ResMed dealer or ResMed office. 10

Mask components / Composants du masque / Piezas de la mascarilla / Componentes da máscara AirFit N10 AirFit N10 for Her A Headgear / Harnais / Arnés / Arnês 63260 (Std) 63261 (S) 1 Upper headgear straps / Sangles supérieures du harnais / Correas superiores del arnés / Correias superiores do arnês 2 Lower headgear straps / Sangles inférieures du harnais / Correas inferiores del arnés / Correias inferiores do arnês B Cushion / Bulle / Almohadilla / Almofada 63240 (Std) 63241 (S) 63242 (W) C Frame / Entourage rigide / Armazón / 63270 63270 Armação 3 Vent / Orifice de ventilation / Ventilación / Respiradouro 4 Short tube / Tuyau court / Tubo corto / Tubo curto 5 Swivel / Pièce pivotante / Pieza giratoria / Peça giratória B+C Frame system / Entourage complet / Sistema 63230 (Std) 63231 (S) de armazón / Sistema da armação 63232 (W) 6 Magnet clips / Clips magnétiques / Broches magnéticos / Presilhas magnéticas 7 Soft sleeves / Gaines souples / Fundas blandas / Mangas maleáveis A+B+C Complete system / Système complet / Sistema completo / Sistema completo 63200 (Std) 63202 (W) 63201 (S)

S: Small / Petit / Pequeño / Pequeno Std: Standard / Standard / Estándar / Padrão W: Wide / Large / Ancho / Largo

A 1 2 B C 3 4 AirFit N10 for Her 5 6 7 ResMed Ltd DISTRIBUTED BY 1 Elizabeth Macarthur Drive ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA Bella Vista NSW 2153 ResMed (UK) Ltd 96 Jubilee Ave Milton Park Abingdon Australia Oxfordshire OX14 4RW UK See www.resmed.com for other ResMed locations worldwide. For patent information, see www.resmed.com/ip. AirFit is a trademark of ResMed Ltd. 2014 ResMed Ltd. 628051/4 2014-04 ResMed.com 628051