DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

Similar documents
MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

The Helium Leak Detector

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

LEAP CO 2 Laboratory CO 2 mixtures test facility

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Optimizing Gas Supply for Industrial Lasers

High Pressure Asher HPA-S

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

Generating Calibration Gas Standards

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

FCTechnik. flox[control] Gas Control Units for Aluminium Production. for aluminium production flox[control] flox[on] FC Technik 1

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

Tensiometer For the measurement of surface and interfacial tension

Differential Pressure Transmiter

Potter Nitrogen Generators

Tensiometer For the measurement of surface and interfacial tension

Procedures for operation of the TA Instruments DSC

Quick Start Guide for SA-9600 Series Surface Area Analyzer

Discovery HP-TGA 75/750. Site Preparation Guide

Instruction Manual Dräger MSI P7 and MSI P7 plus

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Petro-Chemical & Analyzer Sampling Systems

Hovacal DATASHEET JUNHO 2013

LFE OEM TCD - Thermal Conductivity Detector

The Principles of Vacuum Technology

The Decomposition of Potassium Chlorate

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

APPLICATION NOTE. GC Integrated Permeation Device

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

EXAM # 2. First Name Last Name CIRCLE YOUR LECTURE BELOW: INSTRUCTIONS

Chapter 13 Temperature, Kinetic Theory, and the Gas Laws 497

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

1. [Chang7 5.P.013.] Convert 295 mmhg to kpa. kpa Convert 2.0 kpa to mmhg. mmhg

Hiden QIC Series Gas Analysers Real-time gas analysis systems

CHM 111 Unit 5 Sample Questions

Both physical and chemical effects come into play either separately or in combination.

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Succeeding with Production Air Leak Testing Methods. Paul Chamberlain President, CEO

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Carrier Gases in Capillary GC

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Petro-Chemical & Analyzer Sampling Systems

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Operation of the Perkin Elmer TGA-GC/MS

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

EasyLine Continuous Gas Analyzers. So smart, they re simple

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Major Design Features

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

High Purity & Ultra High Purity

MMS Mercury Monitoring System for Natural Gas

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

HiQ laboratory gas generators.

Agilent Auxiliary Gas Module AGM 2. User s Guide

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Phase Changes * OpenStax

Ignition Sensitivity of Nonmetallic Materials in Oxygen-Enriched Air NITROX : A Never Ending Story in SCUBA Diving?

Quebec Quebec Tel : Fax : MSDS: Methane, Oxygen in Nitrogen Mixture PRODUCT INFORMATION

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

The content of your gas cylinders. Pocket Safety Guide No. 1


Date: Period: Gas Laws Worksheet #1 - Boyle s, Charles, Gay-Lussac s, and Combined Gas Law

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Practical approach and problems in in-situ RGA calibration

Name Chemistry Pre-AP

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

deltaflowc deltaflowc Venturi or Probe

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Standard Test Methods for Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point 1

KRONES filling systems for beer Filling of glass containers and cans

Technical Data Sheet MF010-O-LC

Chemistry 1B Chapter 10 Worksheet - Daley. Name

Online DGA-monitoring of power transformers

MV5: Automated concentration system

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

Unit 8: Kinetic Theory Homework Packet (90 points)

Less oxygen, more safety and quality. Targeted protection during production, storage and transportation, through inerting

Under pressure pushing down

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Temperature Influence on the Flammability Limits of Heat Treating Atmospheres

Level MEASUREMENT 1/2016

This test shall be carried out on all vehicles equipped with open type traction batteries.

Heat Pump Connections and Interior Piping

Transcription:

DSC 204 HP Phoenix High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

DSC 204 HP Phoenix The ability to apply pressure improves the capabilities of Differential Scanning Calorimetry (DSC). High-Pressure DSC Differential Scanning Calorimetry (DSC) allows not only for the determination of phase transformation temperatures but also for the quantification of transformation enthalpies. In the low-temperature range, samples are generally analyzed in aluminum crucibles with a pierced lid under atmospheric pressure in a constant purge gas flow. With a type of modified DSC where the measuring cell is installed in an autoclave (a pressure DSC ) it becomes possible to carry out measurements under pressures ranging from 5 kpa to 15 MPa (high-pressure DSC). Measurements in Inert or Reactive Gas Atmospheres High-pressure DSC measurements can be carried out in inert or reactive gas atmospheres. If an inert gas is used, the pressure dependency can be studied when sample transformation (usually a caloric effect) is also accompanied by a volume change. This allows for the investigation of dehydration and decomposition reactions with gas release by means of pressure DSC. When using a reactive gas, the gas becomes one of the reactants and the pressure therefore is a measure of its concentration. With this method, aging tests can be performed on organics (such as oils, fats, waxes, greases, etc.) and polymers. Calibration Within the accessible pressure range, melting is only slightly pressuredependent. It is therefore possible to employ metallic reference materials commonly used for DSC measurements for temperature and enthalpy calibration. Application Range of HP-DSC Determination of vapor pressure and evaporation heat (ASTM E1782) Separation of reactions with overlapped evaporation Measurement of adsorption and desorption, e.g., on metallic compounds Oxidation stability of oils, fats, and lubricants (ASTM E1858, ASTM D6186, ASTM E2009, ASTM D5483) Curing of thermosets, e.g., phenolic resins Vulcanization of elastomers Hydration of unsaturated fatty acids Susceptibility of materials to melting point depression in reactive gas atmosphere DSC measurements under ambient pressure can, of course, also be conducted with the DSC 204 HP Phoenix, even under reduced pressure 2

increasing T with p = constant, V expands increasing T with V = constant, p increases 3

DSC 204 HP Phoenix Trendsetting Technology High-Pressure DSC Measurements Even at Subambient Temperatures In contrast to the setup of a regular DSC, the measuring cell of a high-pressure DSC (HP-DSC) is surrounded by an autoclave which is supported by pressure and gas flow control systems. Pressure and purge gas flow are adjusted via a separate control board (see also next page). With the help of liquid nitrogen cooling, it is even possible to achieve temperature programs in the subambient range. The heating and cooling rates achieved (0.01 K/min to 100 K/min and to 50 K/min, respectively) as well as the maximum and minimum temperatures are significantly influenced by the atmosphere and pressure used (e.g., in a helium atmosphere, it is possible to cool down to -70 C at 10 MPa). Thermostat hose connection (outlet) Knurled nut Thermostated lid Sensor Thermostat hose connection (inlet) Cross section of the measuring cell of the coolable DSC 204 HP Phoenix with surrounding autoclave LN 2 cooling 4

In some reactions, the atmosphere not only serves for the generation of pressure but is also a reaction partner in the expected solid-gas reaction. Regulation of pressure and gas flow must be particularly precise. Precise Pressure and Gas Flow Control Measurements in different gas atmospheres such as O 2, N 2, Ar, He, H 2, CO 2 and CH 4 are no problem in the robust measuring cell. The sample atmosphere can be either static or dynamic. The optional electronic pressure control device along with the ability to precisely regulate the purge gas flow are the main features allowing for outstanding accuracy and reproducibility of the measurements. The system also allows for measurements under adjustable reduced pressure. Of course, the DSC 204 HP Phoenix meets all safety regulations which are required for measurements under pressure. Pressure Control Systems for Operation under: Static gas atmosphere Dynamic gas atmosphere Application Constant (defined) gas pressure up to 15 MPa during heating Constant (defined) gas pressure during heating and constant (defined) gas flow at the sample Measurement in static or dynamic gas mixture Use of an inert gas (e.g., Ar) to establish a defined gas pressure and measurement under a dynamic reaction gas atmosphere (e.g., O 2 at 100 ml/min) Autoclave with DSC cell Burst disk Connection for vacuum pump LN 2 outlet Pressure indicator Outlet valve Fast outlet valve Electronic pressure control Gas outlet Gas inlet 1 LN 2 inlet Gas inlet 2 Gas 1 Gas 2 Inlet valves Electronic gas flow control Optional pressure control for accurate, highly precise regulation of pressure and gas flow 5

Versatile Applications Synthetic Oil Increasing Oxygen Pressure Resulting in Oxidation at Lower Temperatures This graph shows the oxidation behavior of a stabilized synthetic oil (sample mass of 3.0 mg ± 0.1 mg) in aluminum pans at 2 K/min in oxygen (100 ml/min) under defined pressures. As oxygen pressure increases, oxidation begins at lower temperatures (lower extrapolated onset temperature). Polycondensation Curing Behavior of Phenolic Resins This graph shows the partial area evaluation of the curing effect of two phenolic resin lots (A, B) under a practical pressure of 9 MPa in an inert gas atmosphere at 10 K/min (sample mass 10.5 mg). lot A lot A lot B lot B Hydrogenation of a Metal Catalyst Here shown is the thermal hydrogenation of a metal catalyst under 7 MPa in a pure hydrogen atmosphere (sample mass 6.09 mg; heating rate 10 K/min). 6

1.2 1.0 0.8 0.6 0.4 0.2 0.0 pressure *10-3 /bar 150050 150045 150040 150035 150030 6 7 2α-FeOOH α-fe2o3 + H2O 8 9 10 11 Time /min Area: 173.59 J/g Peak*: 280.8 C pressure / bar 5 10 15 20 25 30 Time / min [1] [1] 150.5 150.4 150.3 150.2 150.1 150.0 Temp. / C 400 350 300 250 200 150 100 50 0 Precision of the Pressure Control, Dehydration of Iron Oxide Hydroxide Just like decomposition, dehydration reactions are significantly influenced by the pressure applied. This example shows a measurement on a nanocrystalline goethite at a heating rate of 10 K/min. With increasing pressure, the release of gaseous reaction products is shifted to higher temperatures: from 251 C at ambient pressure (not shown here) to 281 C at 150 bar. The pressure variations detected during the dynamic heating segment do not exceed 150 bar ± 0.01 bar (a hundred times smaller than prescribed by ASTM D6186). Influences of the pressure on the DSC signal (e.g., noise) are therefore negligible. Key Technical Data DSC 204 HP Phoenix Temperature range Heating rate Cooling device Pressure range Pressure measurement Atmosphere Gas flow Operation modes -150 C to 600 C, depending on gas pressure and type 0.01 K/min to 100 K/min, depending on gas pressure and type Liquid nitrogen; temperature range depends on gas pressure and type Vacuum to 150 bar (15 MPa, 2175 psi) Precision: ± 0.152% of measurement value Accuracy: ± 0.75 bar Static and/or dynamic, inert (N 2, noble gases), reducing (H 2 )*, oxidizing (O 2, air, CO 2 up to 57 bar); other gases on demand Up to 500 ml/min, accuracy ±1 ml/min Various static and dynamic gas atmospheres and pressure conditions * The user is responsible for reliable operation under hydrogen in accordance with relevant safety regulations. 7

The NETZSCH Group is a mid-sized, family-owned German company engaging in the manufacture of machinery and instrumentation with worldwide production, sales, and service branches. The three Business Units Analyzing & Testing, Grinding & Dispersing and Pumps & Systems provide tailored solutions for highest-level needs. Over 3,400 employees at 210 sales and production centers in 35 countries across the globe guarantee that expert service is never far from our customers. When it comes to Thermal Analysis, Calorimetry (adiabatic & reaction) and the determination of Thermophysical Properties, NETZSCH has it covered. Our 50 years of applications experience, broad state-of-the-art product line and comprehensive service offerings ensure that our solutions will not only meet your every requirement but also exceed your every expectation. NETZSCH-Gerätebau GmbH Wittelsbacherstraße 42 95100 Selb Germany Tel.: +49 9287 881-0 Fax: +49 9287 881 505 at@netzsch.com NGB DSC 204 HP Phoenix EN 1216 NWS Technical specifications are subject to change.