SOP Standard Operating Procedure. Etching All Materials

Similar documents
Standard Operating Procedure (SOP)

Standard Operating Procedure (SOP)

Hydrofluoric Acid SOP

Standard Operating Procedure for Solvent use in EMAL

Standard Operating Procedure (SOP)

Standard Operating Procedure

Laboratory Standard Operating Procedure: Sensitizers

TEMPLE UNIVERSITY A Commonwealth University Environmental Health & Radiation Safety (EHRS)

Hydrofluoric Acid. Syracuse University Laboratory Standard Operating Procedure. I. Purpose: Physical and Chemical Properties: Potential Hazards:

Laboratory Standard Operating Procedure: Specimen Preservatives

Laboratory Standard Operating Procedure: Irritants

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

Working Safely with Hydrofluoric Acid

Laboratory Standard Operating Procedure: Reproductive Toxins

STANDARD OPERATING PROCEDURE (SOP): URETHANE

Laboratory Standard Operating Procedure: Carcinogens

Chemical Spill Clean-up Protocol

Laboratory Standard Operating Procedure: Acutely Toxic Substances

University of Saskatchewan Department of Mechanical Engineering Standard Operating Procedure # Mat0006

Corrosives- Strong Bases

General Safety Rules

Hazardous Materials Spill Response

HYDROFLUORIC ACID USE

The health hazards of HF are dependent upon the concentration, temperature and nature of exposure.

Hazardous Materials Spill Response

University of Saskatchewan Department of Mechanical Engineering Standard Operating Procedure # Mat0002

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

Standard Operating Procedure

EHS-SWP-140. Safe Work Practice. Animal Projects with Chemicals. 1.0 Hazard Description

Standard Operating Procedure

Hydrofluoric Acid. Strong Corrosives Strong Acids (SA) & Acutely Toxic Chemicals (ATC)

Standard Operating Procedure

SAFETY ORIENTATION. University of Evansville Department of Chemistry

Standard Operating Procedure (SOP) for (_Hydrpchloric Acid_)

Laboratory Standard Operating Procedure: Cryogenic Liquids

Safety In the Science Lab

Standard Operating Procedure

Yeo Soh Bee A/Prof Dan Yock Young 28/03/2016 Prepared by Approved By Issue Date

UNH Department of Forensic Sciences

HYDROFLUORIC ACID MANAGEMENT GUIDELINES

TITLE: DEALING WITH LABORATORY SPILLAGES

Use, storage and disposal of flammable liquids

Standard Operating Procedure

Date: Review Date: Assessment Reference: Experiment or Procedure (include a brief description, including equipment used and frequency of exposure):

HYDROFLUORIC ACID SAFETY GUIDELINE

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS

Emergency Response Code CODE BROWN HAZARDOUS SPILLS. Purpose & Authority. Definitions

Hydrogen Cyanide (HCN)

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

Safety Rules for the Science Lab

High School Safety Acknowledgment Form

Contents Introduction Purpose Prevention Chemical transport Planning High risk activities...

OKLAHOMA CITY COMMUNITY COLLEGE PERSONAL PROTECTIVE EQUIPMENT PROGRAM. Environmental Health and Safety

HEALTH HAZARDS AND SYMPTOMS OF EXPOSURE

UNIVERSITY OF HOUSTON-CLEAR LAKE ENVIRONMENTAL, HEALTH AND SAFETY DEPARTMENT

Lab: Safety Due: Lab # 0

STANDARD OPERATING PROCEDURE TEMPLATE

Quenching of Self-Heating Substances and Mixtures

Lab-Specific Standard Operating Procedure (LSOP)- Pyrophoric Chemicals

University of New Haven DEPARTMENT OF CHEMISTRY and CHEMICAL ENGINEERING

13 Listed Carcinogens

Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Revision date: 11/11/2015

Chemical Class Standard Operating Procedures

Student Information & Laboratory Safety Contract

1. Substance Information

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Eric Sheagley, Lab Supervisor Fall, 2015

Standard Operating Procedure (SOP) for ( Ammonium metavanadate )

Laboratory Specific Standard Operating Procedures. This SOP must be kept on file for all laboratory employee training and review.

Instructions for Completing the UW-Madison Laboratory Chemical Hygiene Plan Template

Laboratory Inspection Checklist

Environmental Engineering Laboratory General Guidelines for Safety Practices

Self-Heating Substances and Mixtures H251 H252

WHS Guidelines Working with Chemicals

Wolfson Campus Natural Science Department. Biology Laboratory. Student Safety Contract

Standard Operating Procedure (SOP) for ( Sodium Hydroxide )

: Presto Neutral Deodorant Cleaner

Page 1 of 5 Issue date: June 2013

Safety in the Science Lab

Laboratory Chemical Hygiene Plan

1. Safety glasses are to be worn at all times in the laboratory except in the study area adjacent to the lab.

: PC SECTION 1: Identification of the substance/mixture and of the company/undertaking. SECTION 2: Hazards identification

MATERIAL SAFETY DATA SHEET

Learning Goals of Scientific Process & Lab Safety

Standard Operating Procedure

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Preparation of Nerve Agent Simulant Aerosol

Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Revision date: 03/16/2016

: Enzyme Drain Opener

SECTION 1: Identification of the substance/mixture and of the company/undertaking. SECTION 2: Hazards identification

: Perma Gloss Floor Finish

Quenching of Self-Heating Substances and Mixtures

Safety In the Science Lab Rules and Symbols

Name: (Please print or type) Phone: People Soft ID # (Please print or type) Principal Investigator: (If applicable)

Guide to Safety in the Science Classroom

ENVIRONMENTAL HEALTH AND SAFETY in the ARTS Department of Art and Design

RECORD OF DESIGNATED SUBSTANCE ASSESSMENT

Faculty of Biological Sciences Assessment Title SDS-PAGE Gel Electrophoresis preparation of gels Area/Service Protein Production Facility

Transcription:

SOP Standard Operating Procedure Etching All Materials #1 General Process Description This Sop will describe how to safely etch different materials using different techniques. All work described in this SOP will be done in JHE-246/A, in the fume hood. You MUST have WHMIS Training and HF Training (if necessary) before etching any materials. Contact person is Ed McCaffery Laboratory Manager (Room JHE 248 ext 24985). #2 Hazardous Chemicals/Class of Hazardous Chemicals The acids used to etch materials are usually diluted with water and normally do not exceed 5% concentration; but there are etchants which are very concentrated, and also shock sensitive. Concentrated acids may be fatal if inhaled; and can cause severe eye and skin burns, severe respiratory and digestive tract burns. Contact with other material may cause a fire. Whenever working with concentrated acids it MUST be done in the fume hood. Some of the Acids used in the department are: 1. Hydrofluoric Acid 2. Hydrochloric Acid 3. Nitric Acid 4. Picric Acid 5. Chromic Acid 6. Sulphuric Acid 7. Acetic Acid These are not all of the acids which are used to etch materials but some of the most common. #3 PPE (Personal Protective Equipment) Before etching ALL Persons MUST wear the following: 1. Goggles or Safety Glasses (Prescription or Sun glasses are not enough!) 2. Gloves Nitrile or Neoprene 3. Close Toe shoes 4. Long Pants 5. If working with concentrated acids (Face Shield is required) 6. No Contact Lenses! 7. Ensure that the spill kit is available and that all components of the spill kit are intact.

SOP Etchant con t #4 Engineering / Ventilation Controls All work with etchants must be done in the fume hood, with no other persons working close enough to interfere or come into contact with the etchant; someone should be in the immediate area in case of an emergency, the protective shield on the fume hood drawn down as much as possible, but allowing to work comfortable. The person MUST be wearing all of the required PPE. #5 Special Handling Procedures and Storage Requirements All etchants must be stored in a polypropylene bottle with a proper WHMIS label. DO NOT store any etchants in (Glass, Steel, Ceramic bottles), many etchants will react these materials, and can cause a fire or exposure. If you are creating a new etchant; place a secondary containment tray in the fume hood, when handling and pouring concentrated acids. In case you overfill or spill acids, it will stay in this secondary containment. When pouring from a large acid bottle, pour into a clean beaker then, pour the acid from the beaker into a graduated cylinder (this will help reduce the risk of spillage). If you are working with HF you DON T use any glassware, use the plastic beakers and graduated cylinders which are located in JHE-246A. Remember to slowly pour acid into water, never water into acid! Always rinse any glassware 3 times and collect the rinse into the appropriate Chemical Waste Container. #6 Spill and Accident Procedures If you spill acid and the spill is an immediate threat to your health, leave the room, call 88. Remain nearby. In the event of an acid exposure, follow McMaster University First Aid Instructions posted in the labs. If a fire starts because of the release notify anyone in the immediate area to leave, pull the fire alarm and leave the building, call 88 and remain nearby to inform Security. If you accidentally spilled concentrated acid (e.g., while pouring an acid into the measuring cylinder): Don t panic! Remain calm. If the spill is minor (less than 30mL, note a 5 inch x 7 inch paper towel will absorb 5 ml of water ), and will not pose a health issue; use the appropriate spill-containment kit (Note there is a specific HF Spill kit for HF Spills, any other acids use the Acid Spill kit); pour the absorbent; first make a circle encompassing the spill then pour the absorbent on top of the spill. Find a plastic/neoprene-disposal bottle in room JHE 248 and carefully place the soaked absorbent into the bottle, and place in Chemical Waste label on the container. To minimize contact with the acid during clean-up, use the small broom and dust pan to move the soaked absorbent into the bottle. All of this must be done in the fume hood.

If the spill is significant; larger (> 30 ml) or you flipped over an entire bottle of acid, if the spill does not pose a health hazard; inform any other personal in the lab; then use the spillcontainment kit (Note there is a specific HF Spill kit for HF Spills, any other acids use the Acid Spill kit). Pour the absorbent around the spill then pour the absorbent all over the spill. If spill is greater than 30 ml, or cleanup takes longer than 15 minutes, document the cleanup activity either by calling EOHSS at Ext 24352 or by notating the lab inspection forms. IF THE CONCENTRATED ACID IS RUNNING OUT OF THE FUMEHOOD, place spill-containment absorbent on the spill and contact EOHSS at 24352 or call 88 (Emergency) immediately and leave the laboratory making sure you notify any personal in that lab, but stay nearby to provide information to responders. DO NOT TRY to place the soaked absorbent into the neoprene bottle, as fume evaporating from the concentrated acids pose a serious health hazard. Contact Emergency Response (88), then Ed McCaffery Ext 24895, and Lisa Morine Ext 23314. If the spill runs underneath the fume hood; or lab equipment; or if it goes down sink call EOHSS Ext 24967. #7 Waste Disposal If you ve spilled acid and soaked up acid using absorbent, make sure it is disposed into neoprene bottle (4L). These containers will be labeled with a Chemical Waste Label. Any waste acids are to be dispensed in the Chemical Waste Buckets located in the fume hoods. Any glassware used needs to be rinsed three times prior to washing. #8 Training requirements Prior to entering and working in the laboratory, you must have completed the EOHSS WHMIS training. You will have to retain training documentation for at least one year. Any person performing electrical etching using this SOP must receive training on the contents of this SOP. #9 Approval Required All research staff, students, and Graduate students must be trained prior to starting work with the Electrical Etcher. If working after hours you have to ask for approval from your Supervisor and the Person In-charge, Laboratory Manager Ed McCaffery. #10 Decontamination Once finished the area needs to be cleaned, this includes rinsing all glassware three times making sure the rinsate goes into the waste bottle. Clean all glassware with soap and water and wipe down the fume hood with a soapy sponge. Place all equipment underneath the fume hood.

SOP Etchant con t #11 Designated Area Upon leaving a designated work area, remove any personal protective equipment worn and wash hands. After each use (or day), wipe down the immediate work area. At the end of each project, thoroughly decontaminate the designated area before resuming normal laboratory work in the area. #12 Precise Process Description 1. Make sure you have all personal protective equipment on (safety glasses, gloves, etc) 2. Place your polished sample into a containment tray. 3. Take etchant and apply to polished sample (this can be done many ways depending on the sample); (swabbing, pouring, immersing, etc) 4. Either etch sample by timing or by observation. 5. Once sample is etched rinse it with water in the containment tray. 6. Take sample and immerse it with plenty of water, then wash with soap and water, rinse with Ethanol (over ethanol waste bucket) then quickly dry sample. 7. Any of the collection in the containment tray pour into appropriate waste bucket and rinse three times into the aforementioned waste bucket. 8. Rinse any glassware the same as step 7; then wash with soap and water. 9. Clean area with soapy rag or sponge, and return all glassware and containment trays back to the appropriate spots. 10. Wash gloves thoroughly before removing them.

Laboratory Accident Response Procedures Health Threatening Situation - In the event of an imminent or actual health-threatening emergency (threatening local or public health, safety, or welfare; or the environment outside the immediate area): 1) CALL 88 FOR THE EMERGENCY RESPONSE REMAIN IN THE AREA TO ADVISE RESPONDERS IF YOU CAN. 2) ACTIVATE LOCAL ALARM SYSTEMS IF REQUIRED) Once personal safety is established, call EOHSS at Ext 24352 and proceed with local notifications, below. Health Threatening Situation In the event of a major injury: 1) Notify McMaster Responders: Call 88 (24 hours/day, 7 days/week), then 2) Provide local notifications: Name Phone Number Title Ed McCaffery Ext 24985 Lab Manager/ Principal Investigator Lisa Morine Ext 23314 EOHSS Local Response Situation In the event of a minor injury: 1) Notify personnel in the area and restrict access. 2) Make sure the Anvil is not moving or in a position which could pose more harm, make a record in your lab inspection report, and notify your supervisor. Disclaimer: The SOP as written contains our best understanding at this time on how to work safely with this piece of equipment. When new information is found that would improve the safe use of this equipment it will be added in a timely manner. As it stands we cannot be held liable for misuse or abuse of these instructions through negligence on the user s part or based on the content of these notes.