Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter

Features. Description

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

780S Ultra High Purity Series

Wafer type. the product

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Design Features. General Description

Ultra High Purity Model 780S

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

analytical bulk flow distance FLOW level pressure temperature industrial communication

Technology Solutions Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Steel-Mass Model 640S

RCD - Ultra-Rugged Differential Pressure Flowmeter

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Torque Tube TB300 Digital Transmitters

Integral type Differential pressure flowmeter VNT Series

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

SERIES METAL TUBE VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Sensing. Applications. Features

Turbine Flowmeters for Gas Applications

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Vortex Meters for Liquids, Gas, and Steam

Turbine Flowmeters for Gas Applications

Variable Area Flow Meters

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

BUBBLER CONTROL SYSTEM

mass flowmeter approved by Weights and Measures for custody transfer

BUBBLER CONTROL SYSTEM

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range

Steel-Mass Model 640S

Turbine Flowmeters for Gas Applications (Metric)

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter. GE Sensing. Features. Applications

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

C-1500 Series Velocity Transmitter for HVAC Application (Gas, Liquid) C Thermal Mass Flow Meters. Gas & Liquid Type Mass Flow meter

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

TH-1800-T TRX-700-CNG Converter

Expert Hydrostatic Level Transmitters

RCM 7000/8000 Series Liquid/Gas/Steam Flow Meter Differential Pressure Type, 1/4 to 8 Pipe, Alarm, Freq. & Analog Outputs

Thermatel Model TA2 Mass Flow Transmitter

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Level transmitter LT 100

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

Mass Ultrasonic / 2006 Flow meter INSTRUMENTS, INC. THE FLOW MEASUREMENT. HVA/C Mass Flow Meter (HVA/C 1510)

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Bubble Tube Installations

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

SINGLE VALVE WITH LOW-FLOW BYPASS

Flow metering in gases Introduction to COMBIMASS family

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

9700 Transmitter Submersible hydrostatic level transmitter

Radar, Ultrasonic and RF Level Transmitters

Mass Flow Controller (MFC) for Gases

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

T EK-THERMAL 1700B Thermal Mass Flowmeter

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

The Discussion of this exercise covers the following points:

Autocalibration Systems For In Situ Oxygen Analyzers

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

ABB Instrumentation. Specifications. MagMaster Plus MFF Series Electromagnetic Sensors. MagMaster Plus bringing unsurpassed flowmetering performance

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Deep Submersible Level Transducer Series 300DS

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Turbine Flowmeters for Liquid Applications

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Flowatch Multiphase Flow Meter

Porter Analytical & Industrial Products

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

THERMAL MASS FLOW MEASUREMENT FOR GASES

T EK-COR 1100A Coriolis Mass Flowmeter

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

C-Flow Coriolis Mass Flow Meters

Flow Measurement SITRANS F X

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

CLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

ACV-10 Automatic Control Valve

Mass Flow Controller (MFC) for Gases

Mass Flow Meter (MFM) for gases

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

COMPANY TRICOR CORIOLIS MASS FLOW METERS

Turbine Flowmeters for Liquid Applications (Metric)

Transcription:

VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid to sensor contact. No holes to clog. Aalborg s proprietary DSP algorithm accurately filters vortex frequency. High flow turndown ratio up to :. Dual signal processing technology improves accuracy at low flows. Accuracy of + % of rate. Noise cancellation technology. Extensive Diganostics. Password protected data entry. Volumetric and mass flow information simultaneously displayed. Selectable engineering units. On board computer calculates density and mass flow. Two programmable totalizers. Vortex In-line Flow Meter Shown with Wafer Mounting Vortices are created when a fluid passes around a bluff body as shown in Figure. Vortices are alternately shed on each side of the body, degrees out of phase to each other, resulting in an oscillating pressure gradient. As flow increases the frequency of vortices increases in proportion to the increased flow thereby creating a linear relationship. General Description Constructed of type 30 or 36 stainless steel, wafers may be installed in-line by customer provided or built-in flanges. Key pad or communication interface functionalities include measuring units, programmable flow alarm, two programmable totalizers, programmable flow rate pulse output, two programmable optically isolated outputs, battery backed real time clock (RTC), digital communication interface (RS-232 or RS-5), programmable diagnostic events log and register with date and time stamp, programmable process variable log with date stamp, calibration and flowing fluid parameters adjustment, extensive diagnostics. Our exclusive dual signal processing technology independently measures each vortex on either side of the bluff body and filters out non-flow noise. This results in less noise and higher accuracy throughout the flow range. Aalborg s proprietary DSP algorithm accurately filters vortex frequency, improving the quality of flow measurements. Local 2x6 LCD readout provides flow rate and total flow volume reading in selectable engineering units, diagnostic events indication and feature a password protected access to the process parameters to ensure against tampering or resetting. Vortex In-line Flow Meter Shown with Flange Mounting TABLE - FUNCTIONAL SPECIFICATIONS FLUID TYPES MAXIMUM PRESSURE FLUID TEMPERATURE Steam, Gas, Liquid. 69 bar (00 psig) with wafer mount See Table 50 for flange mount. -20 F to 232 F C std./to 260 F C opt. (- F to 50 F F std./to 500 F F opt). LOW FLOW CUT-OFF Adjustable: Set @ min. per Tables to. HIGH FLOW CUT-OFF Adjustable: Set @ max. per Tables to. VOLTAGE FREQUENCY OUTPUTS 5 to 30 VDC standard. 5 or 230 VAC optional. 50 /60 Hz. Two user programmable analog -20 ma outputs ( Ohms or less load), two sets of user-programmable optically isolated outputs, one user programmable optically isolated flow pulse output, RS-232 or RS-5 Digital Interface with Multi-Drop Capability of up to 255 units (RS-5 option). LINEAR RANGE Reynolds number of >,000. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 5

VORTEX IN-LINE FLOW METERS VX Figure TABLE 2 - PERFORMANCE SPECIFICATIONS FLOW ACCURACY FLOW REPEATABILITY + % of rate. + 0.25% of rate. FLOW TURNDOWN RATIO See Tables to. RESPONSE TIME Adjustable based on NRF and Damping settings (minimum 00 ms). DAMPING Adjustable: to 99 sec. VELOCITY RANGE Liq.:.32 or 000µ to 30 ft/sec. ñd 2 Steam & Gas: (/ñ)/3 to 250 ft/sec. ñ= density (lb/ft3). d= pipe diameter (in). µ= viscosity (cp). AGENCY APPROVALS* TABLE 3 - PHYSICAL SPECIFICATION **MATERIALS OF CONSTRUCTION SHEDDER BAR ELECTRODES METERING TUBE FLANGES ELECTRONICS HOUSING FM and CSA Class Div 2 Groups B,C,D. 30 SS or 36 SS. 30 SS or 36 SS encapsulated ceramic. 30 SS or 36 SS. 30L SS or 36L SS. Epoxy coated aluminum. TABLE - ELECTRONIC SPECIFICATIONS AMBIENT TEMPERATURE TRANSMITTER DISPLAY FUNCTIONS OUTPUT SIGNAL ENCLOSURE PROTECTION ENCLOSURE APPROVALS POWER SUPPLY -2 F to 65 F C (-5 F to 9 F F). Microprocessor-based. Two lines, 6 alphanumeric characters each, programmable for different process variable rate and total. Measuring Units, Programmable Flow Alarm, Two Programmable Totalizers, Programmable Flow Rate Pulse Output, Two Programmable Optically Isolated Outputs, Two Programmable analog -20 ma outputs, Battery Backed Real Time Clock [RTC], Digital communication inter face (RS-232 or RS-5), Programmable Diagnostic events Log and register with date and time stamp, Programmable Process Variable Data Log (total 572 records) with date and time stamp, Calibration and Flowing Fluid parameters adjustment, Extensive Diagnostic. Two programmable analog -20 ma into Ohms or less load, two programmable digital optically isolated (UCE @ 0Vdc, ICE @ 50 ma), one programmable optically isolated flow pulse output (UCE @ 60Vdc, ICE @ 50 ma). NEMA X. UL, CSA, FM Class I Groups B, C, D Class II Groups E, F, G KEMA/CENELEC EEx d IIB 5-30 VDC standard 5 or 230 VAC (optional). CONNECTIONS AND MOUNTINGS 55 MOUNTING POSITION TYPICAL STRAIGHT PIPE REQUIREMENTS TEMPERATURE TAP (BY CUSTOMER) PRESSURE TAP (BY CUSTOMER) PROCESS CONNECTIONS ELECTRICAL CONNECT Vertical, horizontal, angle. Upstream: 20 x D. Downstream: 5 x D. Downstream: 3.5 x D. Upstream: 3.5 x D. ANSI Class 50 RF, RF, RF, Wafer. 3/" FNPT. * Designed to meet. Contact Aalborg for status of the agency approval. **The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

VORTEX IN-LINE FLOW METERS VX Flow Ranges Minimum and maximum flow rates to achieve accuracy in gal/min, L/min. Pipe ID based on schedule 0 steel. TABLE 5 - WATER FLOW RATES AT 60 F F SIZE (INCH) 3/" ".5" 2" 3" " min max min max min max min max min max min max gal/min 0. 7 67.2 7 6.9 2 276.0 62 67.6 7 75.3 L/min 5 52.9 25 25.3 62 62..9 23 2337.9 07 070. Minimum and maximum flow rates to achieve accuracy lb/hr. Pipe ID based on schedule 0 steel. TABLE 6 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (English) SIZE (INCH) 3/" ".5" 2" 3" " PRESSURE (psig) min max min max min max min max min max min max 25 50 75 6. 25.5 0. 5.9 63. 255.3 03.6 59.2 27.2 2.5 67. 9. 272. 2.7 67. 93.5 66.9.3 65 22. 669.3 3. 69.5 22.3. 7. 275.6 375.3 73.5 2756.3 3750.2 250.2 390 66.5 3.9 250.6 3. 665. 3.7 35. 67. 73. 60. 35. 67. 73. 60. 0 25 50 200 69.3 3.6 97.9 26.3 693.2 36.2 97.7 262. 5.3 39. 62. 2. 53. 39 62 20.6 23.3 3.7 00 56. 232. 37. 3999.7 560.7 73. 57. 66.3 62. 733.6 57.5 663. 623.5 5. 277. 95 929 5.3 2773.6 99.9 929.7 3 2223.3 2602. 3357.5 29. 22233. 2602. 33575.2 250 350 00 5.7 2. 2.7 2.3 56.9 2. 26.5 23. 257.3 302.9 352. 0. 2573.2 3029.3 3520.7 0.2 632.2 7.2 65 96.2 632.6 72. 69.5 96. 56.3 23.6 5.3 67.9 563.3 235.7 53.3 67.9 2362.9 27.7 3233 366. 2362.6 277. 32330 366.2 2.. 5627.3 66 27.5 7. 56273 659.9 50 500 550 27. 330.5 360. 27.2 7.5 3305.2 3603. 50. 500.3 59. 599.5 50.3 5002.9 59. 599.9 7.6 229. 350.7 72. 75. 2290.7 3507.3 727. 50. 2053. 2257. 26 507.6 20537.6 22570.6 2609.9 39.9 59 50.7 550.9 399 590 507. 5509.2 7505. 7996.2 77.7 95.7 7505.2 79962.2 777. 957.5 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 56

VORTEX IN-LINE FLOW METERS VX Minimum and maximum flow rates to achieve accuracy in (kg/hr) Pipe ID based on schedule 0 steel. TABLE 7 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (Metric) Size (mm) 20 25 0 50 0 0 Pressure (bara) min max min max min max min max min max min max 2 6.6.7 6.7 2.5 5.6 7. 67. 25.2 7.6.6 27. 0. 75. 5.5 27. 07..6 35.7 6. 0.2 6.2 357. 63.9 0.9 3. 59.7.3 67. 3.2 597. 2. 67.2 69.6 33.6 255.6 37.5 696. 335.7 2556.3 37.9 2.2 232.5 5 65. 2.6 232.9 9.5 65.3 22 39. 55 70..9 39.2 59.9 70. 9.3 66.2 9.5 6.7.3 662. 9.7 66.7 2. 62.7 22.7 26.6 37. 627.3 227.2 266. 370. 27.9 375.5 79 50 279.3 3755. 79.7 5799.6 60.3 0 7. 297.3 602.6 399.6 73.9 2972.9 5.7 62 6.9 225. 57.3 620.2 6.5 2250.5 26 2 30 32 0.7.6 6.6 2.5 07. 6.2 65.5 2.7 67.5.7 93.9 207. 675.3 6.9 93.7 2070.5.6 3.9 76.3 50.7 5.7 39.2 762.9 506. 67.7 7. 795.9 50 677.3 77. 795.7 99.9 53. 659.3 70.3 90.3 533.6 6592.6 702.6 903.2 2677.6 2. 309.7 3309 26776. 20.7 3096.9 3309 3 36 3 0 32..3.3 56.2 32 3.3 2.7 562.3 220.2 233. 26.7 259.9 2202. 233. 266.5 259. 5. 573.5 606 63.5 5. 5735 6059.5 63.6 90. 95.3 2.5 66.9 90.3 953 25.3 66.5 2022. 23.6 226.9 236. 2022.2 236 2269 236. 3520.2 373. 392.3 53.7 3520.9 373. 3922.5 537. Minimum and maximum flow rates to achieve accuracy in CFPM (.7 psia 70 F F) CFM at actual process temperature = min. or max values below *530/ (Actual Temp. ( F F) + 60) Pipe ID based on schedule 0 steel. Flow Temp. 70 F F. TABLE - AIR FLOW RATES AT SELECTED PROCESS PRESSURES (English) Size (inch) 3/" ".5" 2" 3" " Density (lb/ft3) Pressure (psig) min max min max min max min max min max min max 57 0.076 0.3 0.2 0. 0.232 0.2 0.336 0.3 0.0 0.93 0.55 0.596 0.69 0.700 0.752 0.0 0.56.6.636 0 5 20 30 0 50 60 70 0 90 0 20 30 50 200 5 6 7 20 23 26 29 32 35 3 7 50 66 96 5.0 60.3 75.6 6.2 36. 67. 9. 22.7 259.3 29.9 320.5 35. 3.7 2.3 3.0 73.6 50.2 657.2 963. 3 23 2 33 3 3 53 5 6 69 7 79 9 60 7.9 0.3 25. 76.7 227.6 27.5 329. 30. 3.3 2.2 533. 5.0 635.0 65.9 736. 77.7 3.6 93.2 602. 25 3 3 56 6 93 6 3 3 56 6 93 206 26 393 3. 26.3 30. 33. 55. 63. 0. 933. 5. 3. 30. 33. 55. 63.. 933. 205. 263. 3933. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 3 52 73 9 35 56 77 9 29 20 26 22 303 32 3 9 65 307.5 2. 56.7 725.9 935..2 353. 562.6 77. 9.0 290.2 2399.3 260.5 27.7 3026.9 3236. 35.3 9.2 653.0 69 92 6 62 209 256 303 350 396 3 90 537 5 630 677 72 77 05 73 6. 922. 56. 62.2 2092.2 2560.3 302. 396. 396.5 32.5.6 536.7 536.7 630. 6772. 720.9 7709.0 09.3 729.9 20 60 20 23 36 6 527 609 690 7 53 935 6 9 79 26 32 750 256 97.9 605.3 202. 227.7 362.6 57.5 5272. 607.3 6902.2 777. 532.0 936.9 6. 976.7 79.6 2606.5 32. 795.9 256.

VORTEX IN-LINE FLOW METERS VX Minimum and maximum flow rates to achieve accuracy in M 3 /min ( F C,.03 bar). M 3 /min at actual process temperature = minimum or maximum values below x 273 (actual temp ( F C) + 273). Pipe ID based on schedule 0 steel. Flow Temp 0 F C. TABLE 9 - AIR FLOW RATES AT SELECTED PROCESS PRESSURES (Metric) Size (mm) 20 25 0 50 0 0 Density (kg/m3) Pressure (barg) min max min max min max min max min max min max.293.93 2.56 3. 0 0.5 2 0. 0.2 0.3 0..2.9 2.5 3. 0.2 0.3 0. 0.6 2. 3.. 6.25 0.5 0..0.5 5.2 7.7.35 5.9 0.9.3.7 2.6.69 2.97 7.26 25.2.9 2.9 3.9 5. 9. 29.0 3.69 57.90 3. 5. 6.. 33.92 50.66 67.39 0.5 5.2 6.39 7.67.95 3 5 6 0.5 0.6 0. 0.9 5.07 6.33 7.59.6 0..0.2.5.33.0 2..55 2.0 2.6 3. 3.6 20.6 25.7 30.92 36.06 3..3 5.2 6.0 3.39 2.96 5.53 60. 7.7 9.6.6 3.5 77. 96.32 5.5 3.75 3. 6. 20. 23.5 3.3 67.77 20.2 23.70.22.5 2.77.05 7 9.0..2..2.3 2.6 3.9.7.9 2. 2.3 6.62.70 20.77 22.5..6 5. 5.7.20 6.3 5. 56.62 6.9 7.7.6 9. 6.67 77.2 5.0 9.37 5. 7.3 9.2 2.2 53.96 73.7 92.3 2.59 26. 30.2 33.5 36.9 26.6 30.63 335.09 36.55 5.32 6.6 7. 9.5 2 3.5.6..9 5.7 6.3 7.70.96 2.5 2.7 2.9 3. 2.92 27.00 29.07 3.5 6.2 6.7 7.2 7.7 6.76 66.9 72.05 77.9.3. 2.0 2.9 2.9.5 20.0 2.65 23.0 25.0 26.9 2. 230. 250.02 269.23 2. 0.2 3.5 6.9 50.2 02.0 35. 6.9 502.0 22.9 26. 7 20 2.2 2.6 22.75 26.5 3.7. 37.37 3.59 9.3. 92.6.0 5..0 5.35.06 3.6 0. 36.0 03.7 60.3 70.3 602.79 703. Ambient Temperature Range for Electronics ANSI Flange Pressure - Temperature Ratings. Maximum Pressure in psig. TABLE 50 - FLOW METER PRESSURE RATING TEMP. F F MATERIAL -0 to 0 200 00 500 30L SS/36L SS 50# RF 230 95 75 60 5 30L SS/36L SS # RF 505 55 5 30 30L SS/36L SS # RF 00 00 9 25 765 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 5

VORTEX IN-LINE FLOW METERS VX TABLE 5 Flange Mounting Meter Size Flange Rating Bolt diameter Bolts I.D. O.D. W H in. psi in. no. in. in. in. in. 3/ 50 50.5 50 2 50 3 50 50 7/ 3/ 3/7 -/ 3/ 3/ 3/ 7/ -/ 0.72 3.75.625.625 5.25 0.957.25.75.75 5.75.50 5.00 6.25 6.25 7.00.937 6.00 6.50 6.50.50 2. 7.50.25.25 9.50 3.26 9.00.00.75.50 5. 6.25 6.25 7.25 6.3 6.63 6.63 7.5 6.63 7.3 7.25.25 6.75 7.25 7.50 9.75 7.25.00.25 9.75.25 9.00.25.25 9.75.25.25.375 9.95.27.27.76.35.9.9.35.75.25.25 2.25.60.9.9 2.60 2.37 2.7 3.25 3.62 Wafer Mounting TABLE 52 Meter Size Flange Rating Bolt diameter Bolts I.D. O.D. W H in. psi in. no. in. in. in. in. 59 3/ 50 50.5 50 2 50 3 50 50 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 3/ 3/ 3/ 3/ 3/ 7/ 0.72 2.370 2 9.00 0.957 2.70 2 9.20.500 3.500 2 9.60.937.250 2.00 2. 5.97 2.60 3.26 6.997 2.5.37

ORDERING INFORMATION VORTEX IN-LINE FLOW METERS VX MODEL VX STYLE U Wafer - SCH 0 W Wafer - SCH 0 E Flange - SCH 0 F Flange - SCH 0 SIZE: WAFER or FLANGE 07 3/" (20mm).0" (25mm) 5.5" (0mm) 20 2.0" (50mm) 30 3.0" (0mm) 0.0" (0mm) FLUID TYPE G Gas L Liquid S Steam MAX TEMP. 50 F F 5 500 F F MATERIAL 30 SS 6 36 SS To allow us to confirm selection please return completed application data sheet found on Aalborg's web site at www.aalborg.com.. Select style (wafer or flange). 2. Select meter size to match internal pipe diameter 3. Confirm minimum and maximum flow ranges to maintain stated accuracy from liquid, steam, or air from Tables 5 to are within your requirements.. For other gas applications consult factory. 5. Select fluid type. 6. Select maximum temperature capability. 7. Select desired **Material of Construction.. Select mounting connection. 9. Confirm maximum pressure capability of flange/meter rating with process conditions and select flange rating from Table 50. Confirm suitability of standard local mounted electronics.. Select desired transmitter power. 2. Provide: Fluid, Fluid Viscosity, Minimum & Maximum Operating Pressure, Minimum & Maximum Operating Temperature, Density/Specific Gravity or Specific Volume. 3. Provide minimum and maximum flow range. Options: Remote mount electronics up to 0 ft. (30.5 m). = Wafer and Flange Style for Alignment Ring Selection. ** = The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. MOUNTING CONNECTION A Wafer. Using Customer Flanges B Flange Mounting F Other FLANGE RATING A 50# ANSI RF (Alignment Rings Not Required for Wafer Style) B # ANSI RF (Wafer Style Includes Alignment Rings) C # ANSI RF (Wafer Style Includes Alignment Rings) D OTHER N NONE DISPLAY L2 Local with RS232 R2 Remote with RS232 L Local with RS5 R Remote with RS25 POWER 0 2VDC 2 20VAC 22 220VAC VX W L 5 A B L2 22 EXAMPLE: VXW-L-AB-L222 SPECIFY: FLUID NAME or MEASURING DENSITY, FLOW RATE, TEMPERATURE and PRESSURE (STEAM, GASES). Vortex meter, Wafer style, " diameter size, Liquid at maximum 50 F, 30 stainless steel, Customer flanges, Flange # ANSI RF, Local display with RS232, 220V power. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 60

VORTEX MULTI-PARAMETER IN-LINE FLOW METERS mvx Design Features Temperature, pressure, density, volumetric and mass flow measurements. No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid to sensor contact. No holes to clog. High flow turndown ratio up to :. Dual signal processing technology improves accuracy at low flows. Accuracy of + % of rate. Noise cancellation technology. Built in platimum RTD and solid state pressure sensor. On board computer calculates density, volumetric and mass flow. Aalborg s proprietary DSP algorithm accurately filters vortex frequency. Extensive Diganostics log with date and time register. Password protected data entry. Volumetric and mass flow information simultaneously displayed. Selectable engineering units. Two programmable totalizers. Digital communication interface: RS-232 or RS-5. Principles of Operation Vortices are created when a fluid passes around a bluff body as shown in Figure. Vortices are alternately shed on each side of the body, degrees out of phase to each other, resulting in an oscillating pressure gradient. As flow increases the frequency of vortices increases in proportion to the increased flow thereby creating a linear relationship. General Description Constructed of type 36 stainless steel, wafers may be installed inline by customer provided or built-in flanges. Key pad or communication interface functionalities include measuring units, programmable flow alarm, two programmable totalizers, programmable flow rate pulse output, two programmable optically isolated outputs, battery backed real time clock (RTC), digital communication interface (RS- 232 or RS-5), programmable diagnostic events log and register with date and time stamp, programmable process variable log with date stamp, calibration and flowing fluid parameters adjustment, extensive diagnostics. Our exclusive dual signal processing technology independently measures each vortex on either side of the bluff body and filters out non-flow noise. This results in less noise and higher accuracy throughout the flow range. Aalborg s proprietary DSP algorithm accurately filters vortex frequency, improving the quality of flow measurements. Local 2x6 LCD readout provides flow rate and total flow volume reading in selectable engineering units, diagnostic events indication and feature a password protected access to the process parameters to ensure against tampering or resetting. Vortex In-line Flow Meter Shown with Wafer Mounting Vortex In-line Flow Meter Shown with Flange Mounting TABLE 53 - FUNCTIONAL SPECIFICATIONS FLUID TYPES MAXIMUM PRESSURE FLUID TEMPERATURE Steam, Gas, Liquid. 69 bar (00 psig) with wafer mount See Table 62 for flange mount. -20 F to 232 F C std./to 260 F C opt. (- F to 50 F F std./to 500 F F opt). LOW FLOW CUT-OFF Adjustable: Set @ min. per Tables 56 to 60. HIGH FLOW CUT-OFF Adjustable: Set @ max. per Tables 56 to 60. VOLTAGE FREQUENCY OUTPUTS 5 to 30 VDC standard. 5 or 230 VAC optional. 50 /60 Hz. Two user programmable analog -20 ma outputs ( Ohms or less load). Each can be assigned to one of the following process variables: volumetric flow, mass flow, temperature or pressure. Two sets of user programmable digital optically isolat ed outputs to actuate user supplied equipment when various diagnostic or system events occurs. One user programmable optically isolated flow pulse output, RS-232 or RS-5 Digital Interface with Multi-Drop Capability of up to 255 units (RS-5 option). LINEAR RANGE Reynolds number of >,000. 6 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

VORTEX MULTI-PARAMETER IN-LINE FLOW METERS mvx TABLE 5 - PERFORMANCE SPECIFICATIONS FLOW ACCURACY FLOW REPEATABILITY + % of rate. + 0.25% of rate. FLOW TURNDOWN RATIO See Tables 57 to 6. RESPONSE TIME TABLE 55 - PHYSICAL SPECIFICATION **MATERIALS OF CONSTRUCTION Adjustable based on NRF and Damping settings (minimum 00 ms). DAMPING Adjustable: to 99 sec. VELOCITY RANGE Liq.:.32 or 000µ to 30 ft/sec. ñd 2 Steam & Gas: (/ñ)/3 to 250 ft/sec. ñ= density (lb/ft3). d= pipe diameter (in). µ= viscosity (cp). AGENCY APPROVALS* FLUID TEMPERATURE MEASUREMENT RANGE TEMPERATURE ACCURACY (INCLUDING LINEARITY) FLUID PRESSURE MEASUREMENT RANGE PRESSURE ACCURACY (INCLUDING LINEARITY) FLUID PROOF PRESSURE FLUID BURST PRESSURE FM and CSA Class Div 2 Groups B,C,D. 20 to 260 F C (- to 500 F F). + 0.5 F C Can be ordered for the following options: 0-0 PSIA. 0-250 PSIA. 0-500 PSIA 0-750 PSIA. 0-00 PSIA. + 0.5% of full scale. 3 X F.S. X F.S. Figure TABLE 56 - ELECTRONIC SPECIFICATIONS AMBIENT TEMPERATURE TRANSMITTER DISPLAY FUNCTIONS -2 F to 65 F C (-5 F to 9 F F). Microprocessor-based. Two lines, 6 alphanumeric characters each, programmable for different process variable rate and total. Measuring Units, Programmable Flow, Temperature and Pressure Alarms, Two Programmable Totalizers, Programmable Flow Rate Pulse Output, Two Programmable Optically Isolated Outputs, Two Programmable analog -20 ma outputs, Battery Backed Real Time Clock [RTC], Digital communication interface (RS-232 or RS-5), Programmable Diagnostic events Log and register with date and time stamp, Programmable Process Variable Data Log (total 572 records) with date and time stamp, Calibration and Flowing Fluid parameters adjustment, Extensive Diagnostic. SHEDDER BAR ELECTRODES METERING TUBE FLANGES ELECTRONICS HOUSING 36 SS. 36 SS encapsulated ceramic. 36 SS. 36 SS. CONNECTIONS AND MOUNTINGS MOUNTING POSITION TYPICAL STRAIGHT PIPE REQUIREMENTS TEMPERATURE TAP (BY CUSTOMER) PRESSURE TAP (BY CUSTOMER) PROCESS CONNECTIONS ELECTRICAL CONNECT Epoxy coated aluminum. Vertical, horizontal, angle. Upstream: 20 x D. Downstream: 5 x D. Downstream: 3.5 x D. Upstream: 3.5 x D. ANSI Class 50 RF, RF, RF, Wafer. 3/" FNPT. OUTPUT SIGNAL ENCLOSURE PROTECTION ENCLOSURE APPROVALS POWER SUPPLY Two programmable analog -20 ma into Ohms or less load, two programmable digital optically isolated (UCE @ 0Vdc, ICE @ 50 ma), one programmable optically isolated flow pulse output (UCE @ 60Vdc, ICE @ 50 ma). NEMA X. UL, CSA, FM Class I Groups B, C, D Class II Groups E, F, G KEMA/CENELEC EEx d IIB 5-30 VDC standard 5 or 230 VAC (optional). * Designed to meet. Contact Aalborg for status of the agency approval. **The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 62

VORTEX MULTI-PARAMETER IN-LINE FLOW METERS mvx Flow Ranges Minimum and maximum flow rates to achieve accuracy in gal/min, L/min. Pipe ID based on schedule 0 steel. TABLE 57 - WATER FLOW RATES AT 60 F F SIZE (INCH) 3/" ".5" 2" 3" " min max min max min max min max min max min max gal/min 0. 7 67.2 7 6.9 2 276.0 62 67.6 7 75.3 L/min 5 52.9 25 25.3 62 62..9 23 2337.9 07 070. Minimum and maximum flow rates to achieve accuracy lb/hr. Pipe ID based on schedule 0 steel. TABLE 5 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (English) SIZE (INCH) 3/" ".5" 2" 3" " PRESSURE (psig) min max min max min max min max min max min max 25 50 75 6. 25.5 0. 5.9 63. 255.3 03.6 59.2 27.2 2.5 67. 9. 272. 2.7 67. 93.5 66.9.3 65 22. 669.3 3. 69.5 22.3. 7. 275.6 375.3 73.5 2756.3 3750.2 250.2 390 66.5 3.9 250.6 3. 665. 3.7 35. 67. 73. 60. 35. 67. 73. 60. 0 25 50 200 69.3 3.6 97.9 26.3 693.2 36.2 97.7 262. 5.3 39. 62. 2. 53. 39 62 20.6 23.3 3.7 00 56. 232. 37. 3999.7 560.7 73. 57. 66.3 62. 733.6 57.5 663. 623.5 5. 277. 95 929 5.3 2773.6 99.9 929.7 3 2223.3 2602. 3357.5 29. 22233. 2602. 33575.2 250 350 00 5.7 2. 2.7 2.3 56.9 2. 26.5 23. 257.3 302.9 352. 0. 2573.2 3029.3 3520.7 0.2 632.2 7.2 65 96.2 632.6 72. 69.5 96. 56.3 23.6 5.3 67.9 563.3 235.7 53.3 67.9 2362.9 27.7 3233 366. 2362.6 277. 32330 366.2 2.. 5627.3 66 27.5 7. 56273 659.9 50 500 550 27. 330.5 360. 27.2 7.5 3305.2 3603. 50. 500.3 59. 599.5 50.3 5002.9 59. 599.9 7.6 229. 350.7 72. 75. 2290.7 3507.3 727. 50. 2053. 2257. 26 507.6 20537.6 22570.6 2609.9 39.9 59 50.7 550.9 399 590 507. 5509.2 7505. 7996.2 77.7 95.7 7505.2 79962.2 777. 957.5 63 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

VORTEX MULTI-PARAMETER IN-LINE FLOW METERS mvx Minimum and maximum flow rates to achieve accuracy in (kg/hr) Pipe ID based on schedule 0 steel. TABLE 59 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (Metric) Size (mm) 20 25 0 50 0 0 Pressure (bara) min max min max min max min max min max min max 2 6.6.7 6.7 2.5 5.6 7. 67. 25.2 7.6.6 27. 0. 75. 5.5 27. 07..6 35.7 6. 0.2 6.2 357. 63.9 0.9 3. 59.7.3 67. 3.2 597. 2. 67.2 69.6 33.6 255.6 37.5 696. 335.7 2556.3 37.9 2.2 232.5 5 65. 2.6 232.9 9.5 65.3 22 39. 55 70..9 39.2 59.9 70. 9.3 66.2 9.5 6.7.3 662. 9.7 66.7 2. 62.7 22.7 26.6 37. 627.3 227.2 266. 370. 27.9 375.5 79 50 279.3 3755. 79.7 5799.6 60.3 0 7. 297.3 602.6 399.6 73.9 2972.9 5.7 62 6.9 225. 57.3 620.2 6.5 2250.5 26 2 30 32 0.7.6 6.6 2.5 07. 6.2 65.5 2.7 67.5.7 93.9 207. 675.3 6.9 93.7 2070.5.6 3.9 76.3 50.7 5.7 39.2 762.9 506. 67.7 7. 795.9 50 677.3 77. 795.7 99.9 53. 659.3 70.3 90.3 533.6 6592.6 702.6 903.2 2677.6 2. 309.7 3309 26776. 20.7 3096.9 3309 3 36 3 0 32..3.3 56.2 32 3.3 2.7 562.3 220.2 233. 26.7 259.9 2202. 233. 266.5 259. 5. 573.5 606 63.5 5. 5735 6059.5 63.6 90. 95.3 2.5 66.9 90.3 953 25.3 76.7 2022. 23.6 226.9 236. 2022.2 236 2269 236. 3520.2 373. 392.3 53.7 3520.9 373. 3922.5 537. Minimum and maximum flow rates to achieve accuracy in CFPM (.7 psia 70 F F) CFM at actual process temperature = min. or max values below *530/ (Actual Temp. ( F F) + 60) Pipe ID based on schedule 0 steel. Flow Temp. 70 F F. TABLE 60 - AIR FLOW RATES AT SELECTED PROCESS PRESSURES (English) Size (inch) 3/" ".5" 2" 3" " Density (lb/ft3) Pressure (psig) min max min max min max min max min max min max 0.076 0.3 0.2 0. 0.232 0.2 0.336 0.3 0.0 0.93 0.55 0.596 0.69 0.700 0.752 0.0 0.56.6.636 0 5 20 30 0 50 60 70 0 90 0 20 30 50 200 5 6 7 20 23 26 29 32 35 3 7 50 66 96 5.0 60.3 75.6 6.2 36. 67. 9. 22.7 259.3 29.9 320.5 35. 3.7 2.3 3.0 73.6 50.2 657.2 963. 3 23 2 33 3 3 53 5 6 69 7 79 9 60 7.9 0.3 25. 76.7 227.6 27.5 329. 30. 3.3 2.2 533. 5.0 635.0 65.9 736. 77.7 3.6 93.2 602. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 25 3 3 56 6 93 6 3 3 56 6 93 206 26 393 3. 26.3 30. 33. 55. 63. 0. 933. 5. 3. 30. 33. 55. 63.. 933. 205. 263. 3933. 3 52 73 9 35 56 77 9 29 20 26 22 303 32 3 9 65 307.5 2. 56.7 725.9 935..2 353. 562.6 77. 9.0 290.2 2399.3 260.5 27.7 3026.9 3236. 35.3 9.2 653.0 69 92 6 62 209 256 303 350 396 3 90 537 5 630 677 72 77 05 73 6. 922. 56. 62.2 2092.2 2560.3 302. 396. 396.5 32.5.6 536.7 536.7 630. 6772. 720.9 7709.0 09.3 729.9 20 60 20 23 36 6 527 609 690 7 53 935 6 9 79 26 32 750 256 97.9 605.3 202. 227.7 362.6 57.5 5272. 607.3 6902.2 777. 532.0 936.9 6. 976.7 79.6 2606.5 32. 795.9 256. 6

VORTEX MULTI-PARAMETER IN-LINE FLOW METERS mvx Minimum and maximum flow rates to achieve accuracy in M 3 /min ( F C,.03 bar). M 3 /min at actual process temperature = minimum or maximum values below x 273 (actual temp ( F C) + 273). Pipe ID based on schedule 0 steel. Flow Temp 0 F C. TABLE 6 - AIR FLOW RATES AT SELECTED PROCESS PRESSURES (Metric) Size (mm) 20 25 0 50 0 0 Density (kg/m3) Pressure (barg) min max min max min max min max min max min max.293.93 2.56 3. 0 0.5 2 0. 0.2 0.3 0..2.9 2.5 3. 0.2 0.3 0. 0.6 2. 3.. 6.25 0.5 0..0.5 5.2 7.7.35 5.9 0.9.3.7 2.6.69 2.97 7.26 25.2.9 2.9 3.9 5. 9. 29.0 3.69 57.90 3. 5. 6.. 33.92 50.66 67.39 0.5 5.2 6.39 7.67.95 3 5 6 0.5 0.6 0. 0.9 5.07 6.33 7.59.6 0..0.2.5.33.0 2..55 2.0 2.6 3. 3.6 20.6 25.7 30.92 36.06 3..3 5.2 6.0 3.39 2.96 5.53 60. 7.7 9.6.6 3.5 77. 96.32 5.5 3.75 3. 6. 20. 23.5 3.3 67.77 20.2 23.70.22.5 2.77.05 7 9.0..2..2.3 2.6 3.9.7.9 2. 2.3 6.62.70 20.77 22.5..6 5. 5.7.20 6.3 5. 56.62 6.9 7.7.6 9. 6.67 77.2 5.0 9.37 5. 7.3 9.2 2.2 53.96 73.7 92.3 2.59 26. 30.2 33.5 36.9 26.6 30.63 335.09 36.55 5.32 6.6 7. 9.5 2 3.5.6..9 5.7 6.3 7.70.96 2.5 2.7 2.9 3. 2.92 27.00 29.07 3.5 6.2 6.7 7.2 7.7 6.76 66.9 72.05 77.9.3. 2.0 2.9 2.9.5 20.0 2.65 23.0 25.0 26.9 2. 230. 250.02 269.23 2. 0.2 3.5 6.9 50.2 02.0 35. 6.9 502.0 22.9 26. 7 20 2.2 2.6 22.75 26.5 3.7. 37.37 3.59 9.3. 92.6.0 5..0 5.35.06 3.6 0. 36.0 03.7 60.3 70.3 602.79 703. Ambient Temperature Range for Electronics ANSI Flange Pressure - Temperature Ratings. Maximum Pressure in psig. TABLE 62 - FLOW METER PRESSURE RATING 65 TEMP. F F MATERIAL -0 to 0 200 00 500 30L SS/36L SS 50# RF 230 95 75 60 5 30L SS/36L SS # RF 505 55 5 30 30L SS/36L SS # RF 00 00 9 25 765 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

VORTEX MULTI-PARAMETER IN-LINE FLOW METERS mvx TABLE 63 Flange Mounting Meter Size Flange Rating Bolt diameter Bolts I.D. O.D. W H in. psi in. no. in. in. in. in. 3/ 50 50.5 50 2 50 3 50 50 7/ 3/ 3/7 -/ 3/ 3/ 3/ 7/ -/ 0.72 3.75.625.625 5.25 0.957.25.75.75 5.75.50 5.00 6.25 6.25 7.00.937 6.00 6.50 6.50.50 2. 7.50.25.25 9.50 3.26 9.00.00.75.50 FOR DIMENSIONS CONTACT AALBORG CUSTOMER SERVICE DEPARTMENT 9.75.25.25.375 9.95.27.27.76.35.9.9.35.75.25.25 2.25.60.9.9 2.60 2.37 2.7 3.25 3.62 Wafer Mounting TABLE 6 Meter Size Flange Rating Bolt diameter Bolts I.D. O.D. W H in. psi in. no. in. in. in. in. 3/ 50 50.5 50 2 50 3 50 50 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 3/ 3/ 3/ 3/ 3/ 7/ 0.72 2.370 9.00 0.957 2.70 9.20.500.937 3.500.250 FOR DIMENSIONS CONTACT AALBORG CUSTOMER SERVICE DEPARTMENT 9.60.00 2. 5.97.60 3.26 6.997.37 66

ORDERING INFORMATION VORTEX MULTI-PARAMETER IN-LINE FLOW METERS mvx MODEL VX STYLE S T C D Wafer - SCH 0 Pressure, Temperature Wafer - SCH 0 Pressure, Temperature Flange - SCH 0 Pressure, Temperature Flange - SCH 0 Pressure, Temperature SIZE: WAFER or FLANGE 07 3/" (20mm).0" (25mm) 5.5" (0mm) 20 2.0" (50mm) 30 3.0" (0mm) 0.0" (0mm) FLUID TYPE G Gas L Liquid S Steam MAX TEMP. / PRESSURE 0 50 F F / 0 PSIA 50 F F / 250 PSIA 2 50 F F / 500 PSIA 3 50 F F / 750 PSIA 50 F F / 00 PSIA 5 500 F F / 0 PSIA 6 500 F F / 250 PSIA 7 500 F F / 500 PSIA 500 F F / 750 PSIA 9 500 F F / 00 PSIA MATERIAL 6 36 SS To allow us to confirm selection please return completed application data sheet found on Aalborg's web site at www.aalborg.com.. Select style (wafer or flange). 2. Select meter size to match internal pipe diameter 3. Confirm minimum and maximum flow ranges to maintain stated accuracy from liquid, steam, or air from Tables 57 to 6 are within your requirements.. For other gas applications consult factory. 5. Select fluid type. 6. Select maximum temperature capability. 7. Select desired **Material of Construction.. Select mounting connection. 9. Confirm maximum pressure capability of flange/meter rating with process conditions and select flange rating from Table 62.. Confirm suitability of standard local mounted electronics.. Select desired transmitter power. 2. Provide: Fluid, Fluid Viscosity, Minimum & Maximum Operating Pressure, Minimum & Maximum Operating Temperature, Density/Specific Gravity or Specific Volume. 3. Provide minimum and maximum flow range. Options: Remote mount electronics up to 0 ft. (30.5 m). = Flange and Wafer Style for Alignment Ring Selection. ** = The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. MOUNTING CONNECTION A Wafer. Using Customer Flanges. B Flange Mounting. F Other. FLANGE RATING A 50# ANSI RF (Alignment Rings Not Required for Wafer Style) B # ANSI RF (Wafer Style Includes Alignment Rings) C # ANSI RF (Wafer Style Includes Alignment Rings) D OTHER N NONE DISPLAY L2 Local with RS232 R2 Remote with RS232 L Local with RS5 R Remote with RS25 POWER 0 2VDC 2 20VAC 22 220VAC 67 VX D L 6 A B L2 22 EXAMPLE: VXD-L-6AB-L222 SPECIFY: FLUID NAME or MEASURING DENSITY, FLOW RATE, TEMPERATURE and PRESSURE (STEAM, GASES). Vortex meter, Flange style, " diameter size, Liquid at maximum 50 F, 00 PSIA, 36 stainless steel, Customer flanges, Flange # ANSI RF, Local display with RS232, 220V power. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

VORTEX INSERTION FLOW METERS ivx Design Features Principles of Operation Wide range of available insertion inside diameter applications. Installation by porting into piping without need to lengthening line. Optional installation and servicing removal of meter without shutting off line. No moving parts to wear or fail Electronics can be remotely mounted up to 30.5 m (0 ft). No holes to clog. Aalborg s proprietary DSP algorithm accurately filters vortex frequency. High flow turndown ratio up to :. Dual sensor signal processing technology improves accuracy at low flows. Accuracy of + % of rate. Noise cancellation technology. Extensive Diganostics. Password protected data entry. Volumetric and mass flow information simultaneously displayed. Selectable engineering units. On board computer calculates density and mass flow. Two programmable totalizers. Vortex Insertion Flow Meter Shown with Fixed Mounting Vortex Insertion Flow Meter Shown with Retractable Mounting Vortices are created when a fluid passes around a bluff body as shown in Figure. Vortices are alternately shed on each side of the body, degrees out of phase to each other, resulting in an oscillating pressure gradient. As flow increases the frequency of vortices increases in proportion to the increased flow thereby creating a linear relationship. General Description Constructed of type 30 or 36 stainless steel, Vortex meters may be inserted into pipe conduits carrying gases, liquids or steam. Insertion applications facilitate inside diameters from to 2 feet! By porting directly into piping, conduit lines need not be lengthened. Optional isolation valve permits installation, servicing, or removal of vortex meters without having to shut gas, liquid or steam processing operations. Key pad or communication interface is provided to access the following parameters: measuring units; programmable flow alarm; two programmable totalizers; programmable flow rate pulse output; two programmable optically isolated outputs; battery backed real time clock (RTC); digital communication interface (RS-232 or RS-5); programmable diagnostic events log and register with date/time stamp; programmable process variable log with date/time stamp; calibration and flowing fluid parameters adjustment; extensive diagnostics. Our exclusive dual signal processing technology independently measures each vortex on either side of the bluff body and filters out non-flow noise. This results in less noise and higher accuracy throughout the flow range. Aalborg s proprietary DSP algorithm accurately filters vortex frequency, improving the quality of flow measurements. User preset temperature and pressure information processed by an on board computer to calculate density and mass flow. Local 2x6 LCD readout provides simultaneous volumetric and mass flow readings, total flow volume reading in selectable engineering units, diagnostic events indication, and password protected - user entered parameters. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 6

VORTEX INSERTION FLOW METERS ivx 69 TABLE 65 - FUNCTIONAL SPECIFICATIONS FLUID TYPES MAXIMUM PRESSURE FLUID TEMPERATURE LOW FLOW CUT-OFF HIGH FLOW CUT-OFF VOLTAGE FREQUENCY OUTPUTS *Designed to meet. Contact Aalborg for status of the agency approval. TABLE 66 - PHYSICAL SPECIFICATIONS **MATERIALS OF CONSTRUCTION SHEDDER BAR ELECTRODES METERING TUBE FLANGES ELECTRONICS HOUSING 30 SS or 36 SS. 30 SS or 36 SS encapsulated ceramic. 30 SS or 36 SS. 30L SS or 36L SS. CONNECTIONS AND MOUNTINGS MOUNTING POSITION TYPICAL STRAIGHT PIPE REQUIREMENTS PROCESS CONNECTIONS ELECTRICAL CONNECT Steam, Gas, Liquid. 69 bar (00 psig) with wafer mount See Table 69 for flange mount. -20 F to 232 F C std./to 260 F C opt. (- F to 50 F F std./to 500 F F opt). Adjustable: Set @ min. per Tables 70 to 73. Adjustable: Set @ max. per Tables 70 to 73. 5 to 30 VDC standard. 5 or 230 VAC optional. 50 /60 Hz. Two user programmable analog -20 ma outputs ( Ohms or less load), two sets of userprogrammable optically isolated outputs, one user programmable optically isolated flow pulse output, RS-232 or RS-5 Digital Interface with Multi-Drop Capability of up to 255 units (RS-5 option). LINEAR RANGE Reynolds number of >,000. Epoxy coated aluminum. Vertical, horizontal, angle. Upstream: 20 x D. Downstream: 5 x D. MNPT, ANSI Class 50 RF, RF, RF, Welded Flange. 3/" FNPT. **The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. TABLE 67 - PERFORMANCE SPECIFICATIONS FLOW ACCURACY FLOW REPEATABILITY FLOW TURNDOWN RATIO RESPONSE TIME + % of rate. + 0.25% of rate. See Tables 70 to 73. Adjustable based on NRF and Damping settings (minimum 00 ms). DAMPING Adjustable: to 99 sec. 000µ VELOCITY RANGE Liq.:.32 or to 30 ft/sec ñd 2 Steam & Gas: (/ñ)/3 to 250 ft/sec ñ= density (lb/ft3) d= pipe diameter (in) µ= viscosity (cp) AGENCY APPROVALS* FM and CSA Class Div 2 Groups B,C,D. TABLE 6 - ELECTRONIC SPECIFICATIONS AMBIENT TEMPERATURE TRANSMITTER DISPLAY FUNCTIONS OUTPUT SIGNAL ENCLOSURE PROTECTION ENCLOSURE APPROVALS POWER SUPPLY -2 F to 65 F C (-5 F to 9 F F). Microprocessor-based. Two lines, 6 alphanumeric characters each, programmable for different process variable rate and total. Measuring Units, Programmable Flow Alarm, Two Programmable Totalizers, Programmable Flow Rate Pulse Output, Two Programmable Optically Isolated Outputs, Two Programmable analog -20 ma outputs, Battery Backed Real Time Clock [RTC], Digital communication interface (RS-232 or RS-5*), Programmable Diagnostic events Log and register with date and time stamp, Programmable Process Variable Data Log (total 572 records) with date and time stamp, Calibration and Flowing Fluid parameters adjustment, Extensive Diagnostic. Two programmable analog -20 ma into Ohms or less load, two programmable digital optically isolated (UCE @ 0Vdc, ICE @ 50 ma), one programmable optically isolated flow pulse out put (UCE @ 60Vdc, ICE @ 50 ma). NEMA X. UL, CSA, FM Class I Groups B, C, D Class II Groups E, F, G KEMA/CENELEC EEx d IIB 5-30 VDC standard, 5 or 230 VAC (optional). www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

VORTEX INSERTION FLOW METERS ivx Ambient Temperature Range for Electronics Figure 2 Figure Dual signal processing technology independently measures each vortex providing increased accuracy and turndown. Flow Meter Pressure Rating ANSI Flange Pressure - Temperature Ratings. Maximum Pressure in psig. TABLE 69 - FLOW METER PRESSURE RATING MATERIAL TEMP. F F -0 to 0 200 00 500 30L SS/36L SS 50# RF 230 95 75 60 5 30L SS/36L SS # RF 505 55 5 30 360 30L SS/36L SS # RF 00 00 9 25 765 720 Flow Ranges Minimum and maximum flow rates to achieve accuracy. Pipe ID based on schedule 0 steel. TABLE 70 - WATER FLOW RATES AT 70 F F " 5" 6" " " 2" " min max min max min max min max min max min max min max gal/min 9 90.3 7 7.6 270 270. 6 675.0 737 7372.0 7 66.3 265 26.9 L/min 5 505.6 70 70.7 22 22.3 770 7696. 279 27905. 3962 396. 7 70. 6" " 20" 2" 30" 36" min max min max min max min max min max min max gal/min 652 652. 209 2095. 2599 2599.0 3760 37595. 5965 596.2 70 7397 L/min 6255 6259.0 797 7969.9 90 9395.3 23 23. 22579 22576.9 3303 33033.6 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 70

VORTEX INSERTION FLOW METERS ivx Minimum and maximum flow rates to achieve accuracy in (lb/hr). Pipe ID based on schedule 0 steel. TABLE 7 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (English) Pressure " 6" " " 2" " 6" " 20" (psig) min max min max min max min max min max min max min max min max min max 25 50 75 2 752 67 2 757 3 66 9 706 2697 3669 92 705 26967 3669 95 295 670 635 97 29539 6696 63535 296 656 7360 05 2965 6560 7360 06 239 6609 25 2392 66090 79 25 52 799 2629 73 52 797 2629 72 6693 3 695 223 66927 32 699 2229 72 3207 2079 20 75 32073 207 2077 527 6 259 35299 5266 6 2590 352993 0 25 50 200 20 262 2 37 2007 269 23 3777 63 557 6539 37 632 5570 6539 37 020 9675 323 6 095 9676 322 609 26 529 7 23029 2606 529 75 23025 793 266 2533 326 7930 266 25330 3263 269 2665 30622 3952 265 2667 30622 3959 232 37 39997 5607 23279 372 399966 5607 3557 3257 50627 65323 35567 32569 50626 653233 5556 5375 62909 7 55555 5375 62907 707 250 350 00 50 55 536 622 7 7979 550 335 339 796 796 220 220 00 00 5362 269 26 26 263 33209 33206 739 73 627 7 26 26 3596 35963 576 576 73 7979 623 7 6226 7 279 3355 2793 3355 006 9223 0057 92230 6265 7055 62650 7057 00 3995 6326 63257 007 0069 9929 9929 56979 56979 72 72 920 9200 705 7053 62223 7550 622229 7550 695 96 6953 96 9 936 360 360 22 222 55 55 799 7993 75 752 95 950 7206 7206 Minimum and maximum flow rates to achieve accuracy in (kg/hr). Pipe ID based on schedule 0 steel. TABLE 72 - SATURATED STEAM FLOW RATES AT SELECTED PROCESS PRESSURES (English) Pressure 0mm 50mm 200mm 250mm mm 350mm 00mm 50mm 500mm (bar abs) min max min max min max min max min max min max min max min max min max 2 6 3 257 93 722 32 257 927 72 305 5 63 305 52 630 527 2 936 236 5272 6 936 236 3 595 3052 7 3 596 305 70 226 332 636 796 22635 339 636 26 2736 5236 767 259 27360 52362 76709 62 357 639 09 62 35735 639 09 2357 523 657 262 2357 5232 656 269 2929 562 757 5759 29292 56206 7569 5756 22 72 69 2065 2500 723 69 2069 25003 266 367 66 567 26605 36739 66 5672 607 6362 5 926 6069 636 6 9256 7262 02 279 57 7266 0276 27905 57 30 23 56 29 3076 230 55 290 259 7205 296 26573 2593 72052 295 265730 6273 2272 266 370 6273 22722 26639 37077 20599 25 3622 3932 20595 27 3622 3932 25596 3535 50 5590 255956 35353 50 5599 26 2 30 2965 39 33 2969 6729 3979 7257 33 777 6726 65 65 365 3653 26069 260690 7257 2567 25670 909 906 2 27 7766 3 335 2253 2253 306 3063 35 3397 3666 359 33973 3665 57 392 7629 57 396 7629 52096 5690 6027 520956 569 6027 673 692 793 67339 6923 793 7 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

VORTEX INSERTION FLOW METERS ivx Minimum and Maximum Flow Rates to achieve Accuracy in CFPM (.7 PSIA and 70 F F). PipeID Based on Schedule 0 Steel. TABLE 73 - AIR FLOW RATES AT 60 F F CONDITIONS Density (lb/ft3) 0.076 0.3 0.2 0. 0.232 0.2 0.336 0.3 0.0 0.93 0.55 0.596 0.69 0.700 0.752 0.0 0.56.6.636 Pressure (PSIG) 0 5 20 30 0 50 60 70 0 90 0 20 30 50 200 " 6" " " 2" " min max min max min max min max min max min max 20 6 20 23 36 6 527 60 690 772 53 935 6 9 79 26 32 79 256 97.9 605.3 202. 227.7 362.6 57.5 5272. 6037.3 6902.2 777. 532.0 936.9 6. 976.7 79.6 2606.5 32. 795.9 256. 27 36 56 6 26 95 30 56 79 93 2 2303 2 2673 257 302 3965 52 275 363 562 609 256 3 950 3797 56 790 9337 2 2303 27 26725 2572 309 3965 523 52 69 76 230 55 939 229 26 3 3357 372 066 2 775 530 5 539 76 56 52 693 756 230 56 939 22936 26 26 3357 376 066 206 775 5296 5 536 76 560 2 30 939 29 3056 365 7 733 5292 550 609 699 7527 0 6 9203 997 755 2 07 302 939 2977 3056 3652 70 732 5295 550 609 69979 75266 05 62 92030 996 756 66 563 959 2752 355 339 532 5925 67 75 30 909 99 6 77 2270 3063 7029 296 659 5625 959 27523 355 336 537 5929 67 753 30 90976 9907 639 77 22703 3063 70293 29609 9 9 236 3327 26 52 6203 762 2 9079 03 977 955 29 373 32 5790 20 307 93 7 236 3326 255 523 62030 76 205 90792 0379 9967 955 292 3729 37 5790 20 307 Density (lb/ft3) Pressure (PSIG) 6" " 20" 2" 30" 36" min max min max min max min max min max min max 0.076 0.3 0.2 0. 0.232 0.2 0.336 0.3 0.0 0.93 0.55 0.596 0.69 0.700 0.752 0.0 0.56.6.636 0 5 20 30 0 50 60 70 0 90 0 20 30 50 200 267 3093 35 5597 650 935 606 59 3 363 565 669 20 9372 2062 265 390 7 2669 30930 352 5597 697 9 935 6063 56 3 3630 5652 6675 97 9379 20622 2653 39076 2330 322 395 5500 705 670 255 325 50 6595 9765 2350 22935 252 266 3037 9 23 3225 3950 55000 705 670 2552 2 3253 503 65953 9765 23505 229355 25205 2656 30307 92 295 30 65 63 0 773 273 73 662 652 2062 2259 2560 26530 2500 3070 3239 27 692 www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 2953 6 63 039 7735 273 727 6622 65 2062 225909 25605 26530 2996 30692 3237 2266 6923 7 562 7037 95 2733 552 3 2279 22 26977 2925 3267 35523 337 220 069 697 66 967 75 56 70362 9 27335 552 30 2279 22 269767 2925 3267 355227 3373 2200 067 6973 6606 967 6999 930 76 6523 22 2606 7 35569 033 5092 95 565 59377 639 6 73662 723 2232 97 69995 9303 76 65227 223 26059 75 35569 03307 50923 9539 5655 59377 637 63 73669 7235 2235 97 973 3050 6362 2296 296 36235 260 93 56 62732 69350 759 2605 9229 9553 27 92 2223 2066 97377 309 63620 22963 2966 3623 259 93 5677 627320 693503 75906 260 9229 9553 2777 920 2223 20663 72

VORTEX INSERTION FLOW METERS ivx Flanged Insertion Meter -" MNPT Insertion Meter Note Note -" Insertion Meter Assembly with Insertion Tool and Ball Valve -" Welded Insertion Meter Note 73 Note : Length dependent on pipe diameter, thickness, and mounting. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337

ORDERING INFORMATION VORTEX INSERTION FLOW METERS ivx MODEL VX STYLE I Insertion SIZE: PIPE I.D. / MAX. INSERTION DEPTH * 2 "-2" / 2" 2 25"-36" / " 36 37"-72" / 2" 73"-" / 36" FLUID TYPE G Gas L Liquid S Steam MAX TEMP. 50 F F 5 500 F F To allow us to confirm selection please return completed application data sheet found on Aalborg's web site at www.aalborg.com.. Style Insertion. 2. Select meter size to match internal pipe diameter (for insertion style select pipe diameter). 3. Confirm minimum and maximum flow ranges to maintain stated accuracy from liquid, steam, or air from Tables 70 to 73 are within your requirements.. For other gas applications consult factory. 5. Select fluid type. 6. Select maximum temperature capability. 7. Select desired **Material of Construction.. Select mounting connection. 9. Confirm maximum pressure capability of flange/meter rating with process conditions and select flange rating from Table 69.. Confirm suitability of standard local mounted electronics.. Select desired transmitter power. 2. Provide: Fluid, Fluid Viscosity, Minimum & Maximum Operating Pressure, Minimum & Maximum Operating Temperature, Density/Specific Gravity or Specific Volume. 3. Provide minimum and maximum flow range. Options: Remote mount electronics up to 0 ft. (30.5 m). MATERIAL 30 SS 6 36 SS = Insertion Style for Alignment Ring Selection. * = Depends on pipe wall thickness and mounting. ** = The selection of materials of construction, is the responsibility of the customer. The company accepts no liability. MOUNTING CONNECTION C Insertion with Flange. D Insertion. With.5 MNPT Thread. E Insertion, Welded. F Other. FLANGE RATING A 50# ANSI RF (Alignment Rings Not Required for Wafer Style) B # ANSI RF (Wafer Style Includes Alignment Rings) C # ANSI RF (Wafer Style Includes Alignment Rings) D OTHER N NONE DISPLAY L2 Local with RS232 R2 Remote with RS232 L Local with RS5 R Remote with RS25 POWER 0 2VDC 2 20VAC 22 220VAC VX I 2 L 5 E B L2 22 EXAMPLE: VXI-2L-5EB-L222 SPECIFY: FLUID NAME or MEASURING DENSITY, FLOW RATE, TEMPERATURE and PRESSURE (STEAM, GASES). Vortex meter, Insertion style, " diameter size, Liquid at maximum 500 F, 30 stainless steel, Insertion Welded Mounting Connection, Flange # ANSI RF, Local display with RS232, 220V power. www.aalborg.com - e-mail info@aalborg.com - 5.770.0 - fax 5.770.30 - Toll Free in U.S.A. and Canada.00.66.337 7