Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Similar documents
Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Colorado Division of Fire Prevention & Control Driver Operator JPRs (NFPA 1002, 2014 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

Fire Apparatus Operator: ARFF

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

Emergency Vehicle Driver

State of Oregon Department of Public Safety Standards and Training. Driver Task Book. Task Book Assigned To:

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019

Apparatus Operator/Pumper

Driver Releasal Manual

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus.

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker:

Fire Service Training The University of Kansas. Fire Apparatus Driver/Operator Study Guide June National Certification Program

Apparatus Operator Refresher Training Program

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

APPARATUS DRIVER / OPERATOR PUMPER

Driver Operator Pumps: Basic Pump Operations

DRIVER/OPERATOR - PUMPER NFPA 1002

Firefighter Code of Ethics

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

KILGORE FIRE DEPARTMENT

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

TurboDraft Fire Eductor

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

Chapter 14 Water Shuttle Operations

LOS ANGELES COUNTY FIRE DEPARMENT APPARATUS OPERATOR 1C TILLERED EMERGENCY VEHICLE OPERATIONS

City of Mesa Fire/Medical Department Ladder Company Certification Program

FIRE FIGHTER II JPR: FFII-1A

On-Road Skills Demonstration

Head to Head Demo Comparison Sheet

Wilton Fire Protection District. TRAINING DIVISION New apparatus

III. Identify the initial installation requirements for standpipe systems

22. Specialty Valves.

Idaho Fire Service Technology Fire Fighter II

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

Des Plaines Fire Dept. Engineer Program

San Ramon Valley Fire Protection District

FIREGROUND HYDRAULICS

Northeastern Illinois Public Safety Training Academy. Course Syllabus 103

TurboDraft. Fire Eductor Operating Instructions.

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

ENGINE 260 REVISED

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Galva Fire Department SOP

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

LEARNER GUIDE. Asphalt Paver (AP) PO Box 2026 Mountain Gate VIC 3156 p: ABN: RTO: 21396

Florissant Valley Fire Protection District Monthly Training Schedule

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

Chapter 1 FF I Orientation and Fire Service History

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal

TABLE OF CONTENTS LIST OF FIGURES. Figure Title

Chapter 6 Performing Basic Vehicle Maneuvers

2017 Volunteer Week - Course Descriptions

CHECKLIST 5: ROADWORK TRAFFIC SCHEME AUDIT

Poudre Fire Authority Driver/Operator Manual Third Edition March 2006

Pannier Corporation Health and Safety Handbook Marking System Group Aerial Lifts Original Date: Section: Revision date: Page: 12/5/ of 11

Piped Air SCBA Refilling System Standard

TECHNICAL DATA. Page 1 of 12

METRO SAFETY COUNCIL FLORIDA ROAD TEST PROCEDURE

Backing up Procedures for School Bus Drivers. Leader s Guide and Quiz

Waterous Relief Valve

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

CITY OF CHICAGO FIRE DEPARTMENT FIRE ENGINEER PROMOTIONAL PROCESS STUDY GUIDE UPDATE FOR THE PROFICIENCY TEST

OPERATION MANUAL NTF-15

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

Trilogy Theory of Operation

Chapter Twenty-eight SIGHT DISTANCE BUREAU OF LOCAL ROADS AND STREETS MANUAL

TECHNICAL DATA CAUTION

INSTALLATION OPERATION MAINTENANCE

At this time of year,

Discharge Relief Valve Operation & Maint.

LEARNER GUIDE. Trencher TS. PO Box 2026 Mountain Gate VIC 3156 p: ABN: RTO: 21396

Aerial Lift Safety Program

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION FIREFIGHTER 2 PERFORMANCE EVALUATION

GENERAL CONDITIONS, REQUIREMENTS & SPECIFICATIONS for Drivers Challenges

October 2004 REVISIONS (2) SUPERELEVATION DEVELOPMENT 11.3(2)

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

TECHNICAL DATA. than the water inlet pressure to the concentrate

Defensive Driving Answers, Resha Oylear September 2013

Cozumel Turbodraft. Operational Considerations

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

HYDRANT/WATER POINT INSPECTION AND MAINTENANCE

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Essentials of Fire Fighting 6 th Edition Firefighter I

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system.

Access Management Standards

Vermont Permit Test Flash Cards

Steam Locomotive Operating Procedures SVLS Locomotive 1973 Steam Up

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Identify the letter of the choice that best completes the statement or answers the question.

TECHNICAL DATA Q= C. Table 1 - Specifications

**ALL SHADED SKILLS MUST BE SIGNED OFF BEFORE LIVE FIRE TESTING MAY OCCUR**

Varying pump capacity affects the required hoseline diameter

Transcription:

Skill Sheet: 1 Standard 4.2.1, 4.2.2 Task: Perform and document routine test, inspection and servicing functions on specified systems and components. Performance Outcome: Given a fire department pumping apparatus, the necessary hand tools, and using the provided vehicle inspection checklist (DO1), the candidate shall complete and document an inspection as outlined below, not to exceed 25 minutes: (Provide Flashlight, Pen, Clipboard, Paper Towel/Rag) 1. Candidate inspect apparatus as they approach looking for signs of damage or leaks 2. Check batteries for fluid level and corrosion 3. Check braking system fluid level or for air level and drain moisture from air tanks 4. Check coolant system for fluid levels, leaks, cleanliness 5. Check electrical system including: warning devices, headlights, running lights, turn signals, and warning lights 6. Check fuel level 7. Check hydraulic fluids for level and leaks (if applicable) 8. Check engine for leaks 9. Check tires for pressure and wear, (tread depth minimum : front 4/32, rear 2/32 ) 10. Check steering system for range of motion and excessive looseness 11. Check engine belts for tightness and wear 12. Check tools, appliances, equipment, lighting 13. Check windshield, wiper blades, and washer fluid 14. Start apparatus, monitor gauges and control devices 15. Document and correctly report any deficiencies 16. Completed in 25 minutes or less 17. Did the candidate perform the skill safely?

Standard 4.2.1, 4.2.2 Idaho Fire Service Technology Vehicle Inspection Checklist DO1 Candidate s Name: Date: _ OK Needs Service Battery Braking system Coolant system Electrical system Fuel Hydraulic fluids Oil Tires Steering system Belts Tools, appliances, and equipment Windshield, wipers, fluid Vehicle is serviceable Vehicle is not serviceable Comments about items needing service: _ Evaluator s Name: Date:

Skill Sheet: 2 Standard 4.3.7, 5.1.1 Task: Perform and document the readiness inspection of a fire department pumper. Performance Outcome: Given a fire department pumping apparatus, the necessary hand tools, and using the provided inspection checklist (DO2), the candidate shall conduct and document a readiness inspection, not to exceed 25 minutes: (Provide Flashlight, Pen, Clipboard, Paper Towel/Rag) 1. Check water tank for level and leaks in the system 2. Check foam tank for level and leaks if applicable 3. Exercise pump valves 4. Check and clean intake strainer 5. Check pump gearbox for proper oil and traces of water 6. Chock wheels 7. Start apparatus and place apparatus in pump gear 8. Operate the pump primer with all pump valves closed. Note vacuum reading 9. Operate the changeover valve while operating from tank or other water source (if applicable) 10. Check packing glands for excessive leaks, if applicable 11. Operate the pump pressure control device(s) 12. Check and operate all fixed systems and equipment (if applicable) a. Generator b. Fixed lighting equipment c. Rescue equipment d. Gas-powered tools e. Air compressor/cascade system 13. Document inspection and maintenance performed 14. Complete skill in allotted 25 minute time frame 15. Did the candidate perform the skill safely?

Standard 4.3.7, 5.1.1 Idaho Fire Service Technology Routine Tests/Inspections Checklist DO2 Candidate s Name: Date: _ OK Needs Service Check water tank for level and leaks in the system Check foam tank for level and leaks if applicable Exercise pump valves Check and clean intake strainer Check pump gearbox for proper oil and traces of water Operate the pump primer with all pump valves closed and note vacuum reading Operate the changeover valve while operating from tank (if applicable) Check packing glands for excessive leaks, if applicable Operate the pump pressure control device(s) Operate all fixed systems and equipment Document inspection and maintenance preformed Vehicle is serviceable Vehicle is not serviceable Comments about items needing service: Evaluator s Name: Date:

Skill Sheet: 3 Standard 4.3.6 Task: Operate a fire department pumper using defensive driving techniques so that control of the vehicle is maintained. Note to Evaluators: It is recommended that this skill be conducted on a driving track or nonpublic roadway. The host department is responsible for defining the predetermined route to include the prescribed maneuvers listed below. Conditions: Given a fire department pumping apparatus and a predetermined routs and a given assignment, the candidate shall demonstrate defensive driving skills by operating the vehicle in a safe manner to accomplish the tasks listed below. 1. Ensures vehicle is prepared for departure 2. Ensures all personnel are seated with safety belts fastened 3. Enters traffic in a safe manner a. Maintains safe following distances b. Maintains control of the vehicle while accelerating, decelerating, and turning, given road, weather, and traffic conditions c. Operating under adverse environmental or driving surface conditions and maintains safe following distances d. Use automotive gauges and controls appropriately 4. Brings apparatus to a safe stop 5. Did the candidate perform the skill safely?

Skill Sheet: 4 Standard 4.3.2 Task: Back a vehicle from a roadway into a restricted space on both the right and let sides of the vehicle. (Alley Dock) Performance Outcome: Given a fire department pumping apparatus, back the vehicle from a roadway into a restricted space on both the right and left sides of the vehicle into a restricted space 12ft in width, requiring 90-degree right-hand or left-hand turns from the roadway, so that the vehicle is parked within the restricted area without having to stop and pull forward and without striking obstructions. A spotter will be used only for the purpose of preventing the striking of an object. 1. Adjust and use mirrors for backing 2. Driver and passenger(s) wearing seatbelts 3. Complete skill correctly without crossing over or striking cones 4. Complete skill without having to stop and pull forward 5. Driver spots apparatus completely within restricted space 6. Did the candidate perform the skill safely?

Skill Sheet: 5 Standard 4.3.3 Task: Maneuver fire department pumper around obstructions on a roadway while moving forward and in reverse. (Serpentine) Performance Outcome: Given a fire department pumping apparatus, cones and a roadway with obstructions, the candidate shall maneuver the apparatus through the obstructions first in reverse and then in forward without stopping to change the direction of motion and without crossing over or striking cones. A spotter will be used only for the purpose of preventing t he striking of an object. 1. Adjust and use mirrors for backing 2. Driver and passenger(s) wearing seatbelts 3. Complete skill correctly without crossing over or striking cones 4. Complete skill without having to stop and pull forward 5. Did the candidate perform the skill safely?

Skill Sheet: 6 Standard 4.3.4 Task: Turn a fire department pumping apparatus around 180 degrees within a confined space. Performance Outcome: Given a fire department pumping apparatus, cones, and a confined area where the vehicle cannot perform a U-turn without stopping and backing up, the candidate shall maneuver the apparatus so that the vehicle is turned 180 degrees without passing over striking obstructions within the given space. A spotter will be used only for the purpose of preventing the striking of an object. No. Task Steps Pass First Test Fail Pass Retest Fail 1. Adjust and use mirrors for backing 2. Driver and passenger(s) wearing seatbelts 3. Complete skill correctly without crossing over or striking cones 4. Did the candidate perform the skill safely?

Skill Sheet: 7 Standard 4.3.5 Task: Maneuver a fire department pumping apparatus in restricted horizontal and vertical clearances (Diminishing Clearance) Performance Outcome: Given a fire department pumping apparatus, cones, and a course with an area of restricted horizontal clearance, the candidate shall maneuver an apparatus thought the area with restricted horizontal space, so that the candidate accurately judges the ability of the vehicle to pass through the openings and that no cones are struck. The candidate shall provide the height of the vehicle within 6 inches but not less than the actual height when asked. The candidate shall also identify the location of the highest point on the apparatus. 1. Adjust and use mirrors for backing 2. Driver and passenger(s) wearing seatbelts 3. Complete skill correctly without crossing over or striking cones 4. When asked, the candidate correctly provided the height of and location of the highest point of the apparatus. Answer shall be within 6 inches, but NOT less than the actual height 5. Did the candidate perform the skill safely?

Skill Sheet: 8 Standard 4.3.1 Task: Drive a fire department pumping apparatus safely over a predetermined route on a public way. Note to evaluator: The host department is responsible for defining the predetermined route to include the prescribed maneuvers listed below. Any situations in the list below that do not exist in the host department s jurisdiction may be omitted. Conditions: Given a predetermined route on a public way that incorporates the maneuvers and features that the driver/operator is expected to encounter during normal operations, so that the apparatus is operated in compliance with all applicable state and local laws and department rules and regulations. 1. Ensures vehicle is prepared for departure 2. Ensures all personnel are seated with safety belts fastened 3. Enters traffic in a safe manner 4. Four left turns and four right turns 5. A straight section of urban street or rural two-lane road at least a mile in length 6. One through-intersection and two intersections where a stop has to be made 7. One railroad crossing 8. One curve, either left or right 9. A section of limited-access highway that includes a conventional ramp entrance and exit and a section of road long enough to allow lane changes 10. A downgrade or up-grade requiring gear changing to maintain speed 11. One underpass or low clearance bridge or obstacle a. Maintains safe following distances b. Maintains control of the vehicle while accelerating, decelerating, and turning, given road, weather, and traffic conditions c. Operating under adverse environmental or driving surface conditions and maintains safe following distances d. Use automotive gauges and controls appropriately 12. Did the candidate perform the skill safely?

Skill Sheet 9 Standard 5.2.1 Task: Using a fire department pumping apparatus, produce an effective hand or master stream given a water source. Performance Outcome: Given a fire department pumping apparatus, supply hose, attack hose, appropriate fittings, tools, nozzles, firefighters to assist, the candidate shall produce and effective hand or master stream given a specified water source so that the pump is engaged, all pressure control and vehicle safety devices are set, the rated flow of the nozzle is achieved a nd maintained, and the apparatus is continuously monitored for potential problems. The correct discharge pressure must be within 5 psi, using the algebraic formula: DP = (CLQ 2 ) + NP + ALP ± ELV. C = Coefficient; L= Length/100; Q = GPM/100; NP = nozzle pressure; APL = appliance loss; and ELV = elevation gain or loss. Evaluator shall specify the GPM flowing and type of nozzle and fire stream, plus any other variable normally encountered by a driver/operator. 1. Candidate calculates appropriate discharge pressure, ± 5 psi (Evaluator chooses fire stream) A. Hand line (minimum 100 of 1 ½ or larger hoses) B. Wyed pair of hand lines (minimum 100 of 2 ½ hoses wyed to a pair of attack lines a minimum 100 of 1 ½ or 1 ¾ hose) C. Master stream (minimum 100 of 2 ½ or larger attack line) 2. Driver and passengers wearing seat belts 3. Stops apparatus and sets parking brake 4. Positions apparatus to operate at a fire hydrant or at a static water source (Evaluator specifies water source) A. Pressurized Source (minimum of 100 of 2 ½ or larger supply hose) B. Static Source (minimum of two 10 sections of draft hose) 5. Chocks wheels 6. Assembles hose lines, nozzles, valves and appliances 7. Makes appropriate connections 8. Operates power transfer from vehicle engine to engage pump 9. Opens tank to pump valve (pressurized source evolution) 10. Drafts (static source evolution) 11. Prime pump 12. Operates pump pressure control system(s) 13. Operates the volume/pressure transfer valve (multistage pumps only) 14. Operates auxiliary cooling systems 15. Transitions from tank water to pressurized source (pressurized source evolution) 16. Monitors discharge pressure and refills water tank (if possible) 17. Completes skill without creating a water hammer or pump cavitation 18. Did the candidate perform the skill safely?

Idaho Fire Service Technology

Skill Sheet 10 Standard 5.2.2 Task: Establish a relay pumping evolution and produce an effective water supply given a water source. Performance Outcome: Given a fire department pumping apparatus, supply hose, and the length and size of a pre-laid relay line (2 ½ or larger), appropriate fittings, tools, firefighters to assist, and the desired flow and intake pressure, the candidate shall produce and maintain an effective water supply relay to an attack pumper, given a specified water source so that the pump is engaged, all pressure control and vehicle safety devices are set, the correct pressure and flow is maintained, and the apparatus is continuously monitored for potential problems. The correct discharge pressure must be within 5 psi, using the algebraic formula: DP = (CLQ 2 ) + NP + ALP ± ELV. C = Coefficient; L= Length/100; Q = GPM/100; NP = nozzle pressure; APL = appliance loss; and ELV = elevation gain or loss. Evaluator shall specify the GPM, length of relay line, attack pumper intake pressure, plus any other variable normally encountered by a driver/operator. 1. Candidate calculates appropriate discharge pressure, ± 5 psi 2. Driver and passengers wearing seat belts 3. Stops apparatus and sets parking brake 4. Positions apparatus to operate at a fire hydrant or at a static water source (Evaluator specifies water source) A. Pressurized Source B. Static Source 5. Chocks wheels 6. Makes appropriate connections 7. Operates power transfer from vehicle engine to engage pump 8. Opens tank to pump valve (pressurized source evolution) 9. Drafts (static source evolution) 10. Prime pump 11. Establishes water supply 12. Operates pump pressure control system(s) 13. Operates the volume/pressure transfer valve (multistage pumps only) 14. Operates auxiliary cooling systems 15. Transitions from tank water to pressurized source (pressurized source evolution) 16. Monitors discharge pressure and refills water tank (if possible) 17. Completes skill without creating a water hammer or pump cavitation 18. Did the candidate perform the skill safely?

Skill Sheet 11 Standard 5.2.3 Task: Produce a foam fire stream so that properly proportioned foam is delivered. Performance Outcome: Given a fire department pumping apparatus, foam concentrate, foam eductor or apparatus mounted foam system, foam nozzle and other related equipment, hose line, and a hose team, the candidate will assemble a foam layout appropriate for the type of concentrate being used. The candidate will deliver properly proportioned foam and clean the system at the completion of the evolution. 1. Verify correct eductor (or proportioner) and nozzle gallonage 2. Set concentrate percentage 3. Assemble a foam layout appropriate for the type of concentrate being used 4. Set appropriate pump pressure for foam layout 5. Deliver properly proportioned foam 6. Clean or flush system when complete 7. Complete skill without creating a water hammer or pump cavitation 8. Did the candidate perform the skill safely?

Skill Sheet 12 Standard 5.2.4 Task: Supply water to fire sprinkler and standpipe systems given a water source. Performance Outcome: Given a fire department pumping apparatus, specific system information, a minimum of 100 feet of supply hose (2 ½" or larger), the candidate shall produce and maintain an effective water supply to a sprinkler or standpipe system, given a specified water source so that the pump is engaged, all pressure control and vehicle safety devices are set, the correct pressure and flow is maintained, and the apparatus is continuously monitored for potential problems so that water is supplied to the system at the correct volume and pressure.. The correct discharge pressure must be within 5 psi, using the algebraic formula: DP = (CLQ 2 ) + S for sprinkler systems or DP = (CLQ 2 ) + NP + ALP + S ± ELV for standpipes. C = Coefficient; L= Length/100; Q = GPM/100; NP = nozzle pressure; APL = appliance loss; S = sprinkler connection pressure or S = standpipe; and ELV = elevation gain or loss. Evaluator shall specify hose lay, the GPM flowing, type of nozzle and fire stream, plus any other variable normally encountered by a driver/operator. 1. Candidate calculates appropriate discharge pressure, ± 5 psi (Evaluator specifies type of system) A. Sprinkler system B. Standpipe system 2. Driver and passengers wearing seat belts 3. Stops apparatus and sets parking brake 4. Positions apparatus to operate at a fire hydrant or at a static water source (Evaluator specifies water source) A. Pressurized Source B. Static Source 5. Chocks wheels 6. Makes appropriate connections 7. Operates power transfer from vehicle engine to engage pump 8. Opens tank to pump valve (pressurized source evolution) 9. Drafts (static source evolution) 10. Prime pump 11. Establishes water supply 12. Operates pump pressure control system(s) 13. Operates the volume/pressure transfer valve (multistage pumps only) 14. Operates auxiliary cooling systems 15. Transitions from tank water to pressurized source (pressurized source evolution) 16. Monitors discharge pressure and refills water tank (if possible) 17. Completes skill without creating a water hammer or pump cavitation 18. Did the candidate perform the skill safely?