GN 2 CONSTANT FLOW REGULATORS. GUIDANCE NOTE GN 2 Constant Flow Regulators. Page 1 COMMISSIONING SPECIALISTS ASSOCIATION.

Similar documents
2017 Edition GUIDANCE NOTE GN 8 INVERTER DRIVES FOR FANS AND PUMPS GN 8 - INVERTER DRIVES FOR FANS AND PUMPS

CONSTANT FLOW REGULATOR (CFR)

Installation, commissioning and servicing instructions

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

Mainsflush Troubleshooting Guide

Installation, commissioning and servicing instructions

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

Installation, commissioning and servicing instructions

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Scald Protection 3-Way Thermostatic Mixing Valve

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Installation, commissioning and servicing instructions

Scald Protection Three-Way Thermostatic Mixing Valve

Pressure Independent Control Valve (PICV) Fig DN15-32

Installation, commissioning and servicing instructions

Pre-adjustable pressure reducing valves with self-contained cartridge

TECHNICAL DATA. than the water inlet pressure to the concentrate

553 Series.

SAFETY FEATURES OF PORTABLE CRYOGENIC LIQUID CONTAINERS FOR INDUSTRIAL AND MEDICAL GASES

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Rotary Abreast Automatic Teat Sprayer User Manual. Technical Manual Revision 0.01

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Pressure Independent Control Series

Intamix Thermostatic Mixing Valve

System Pressure Manager Standard & System Pressure Manager Plus

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

FloCon Commissioning Modules DESIGN GUIDE - JUNE Variable Flow Systems & Solutions brought to you by Hurlstones

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Veriforce TG CCT 661OP. Training Guide

RiskTopics. Lockout/Tagout October 2017

D05 Pressure Regulating Valves

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

PRESSURE INDEPENDENT CONTROL VALVE (PICV)

INSTALLATION INSTRUCTIONS

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Veriforce TG CCT 609OP. Training Guide

Navigator 600 Silica analyzers

Industry Guidelines POLYETHYLENE (PE) PIPES AND FITTINGS FOR COMPRESSED AIR ISSUE 6.8

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Some system examples

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

92831 TEL: (714) FAX:

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Flamco Flamco-Fill STA Flamco-Fill STM

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

MANUAL FOR INSTALLATION, COMMISSIONING AND MAINTENANCE FOR

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

SUP 15 Health & Safety Management Pressure Systems. Unified procedures for use within NHS Scotland

Expansion Tank Design (Chilled Water)

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

VULCAN GAS SALAMANDER MODEL SG-G

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

SANP ACTING RELAYS YT-520/525/530 SERIES

Model 420-HY Pressure Regulating Hydrant Valve

LOCK UP VALVES YT-400/405/430/435 SERIES

Comparative Tests on Differential Pressure Control Valves

Safety. April 2018 Supersedes all previous publications 2018 Chevron Phillips Chemical Company LP

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

MAINTENANCE AND SAFETY OF CNG REFUELLING STATIONS

The IEC61508 Operators' hymn sheet

Twin & Triple Control Concealed Thermostatic Shower Valve

DS05C,D,G Dial Set Pressure Regulating Valves

PRAHER PLC-MP AQUASTAR MANAUL 2009

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

MANUAL GAS MANIFOLDS

SINGER MODEL 106/206-RPS-L&H

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES

29 SERIES - SAFETY VALVE

Shell & Tube. JATCO Inc. Operating Manual

Accu-Tab Systems 1000 Series by Axiall Corporation

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

C 10 Pressure Reducing Valve

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Series IRV1000/2000/3000

SOLAR AUTOMATIC AIR VENTS AND DEAERATORS FOR SOLAR INSTALLATIONS NEW: AUTOCLOSE DOMESTIC COMMERCIAL SPIRO EXCEPTIONAL GUARANTEE

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

HERZ-Motorised flow controler

AUTOMATIC FLOW CARTRIDGES. Competition Analysis Not All Automatics Are Created Equal

Cim 787 Variable orifice balancing valve

Deluge Optimo Shower valve and kit 10032CP

Pressure relief valve

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

THERMOSTATIC MIXING VALVES

RAC 2200-X/Y-MV DOMESTIC WATER METER TEST BENCH UP TO DN 50 ( 2 ) MANUALLY OPERATED

User Information Sheet 015

Worked Questions and Answers

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Transcription:

GUIDANCE NOTE GN 2 Constant Flow Regulators Page 1 2017 Edition

GUIDANCE NOTE GN2 CONSTANT FLOW REGULATORS Written By M. Lowe, Hattersley Newman Hender Ltd COMPILED BY THE TECHNICAL SUB-COMMITTEE OF THE CSA J Coppin, P Davey, C Davey, C Shearer, D Corner, D Cocksedge, M Todd, A Lucas COPYRIGHT: CSA 1998 9 Kings Court Harwood Road Horsham West Sussex RH13 5UR Tel: 01403 754133 Website: www.csa.org.uk Revision Date Revision 01 25/04/2017 Page 2

DISCLAIMER The purpose of this publication is to provide general guidance for those responsible for the commissioning and any subsequent re-commissioning of building services installations. It is for reference only and does not aim to be comprehensive in content, to be prescriptive or proscriptive in intent, or to be suitable for any particular purpose. Users of this document must exercise their personal judgement in deciding whether to adopt any element of the guidance offered or to deviate from it. This document is compiled from the best information available at the time of publication. The Commissioning Specialists Association, authors and others involved in its publication ( the CSA ) makes no representations or warranties as to the accuracy, completeness or freedom from errors of the document. To the maximum extent permitted by law, the CSA excludes any liability for any accident, damage, loss or liability of any kind resulting directly or indirectly from the use of the guidance provided (therein). Any person or organisation adopting this guidance agrees by doing so to accept full responsibility for any outcome irrespective of the cause (thereof) and to indemnify the Commissioning Specialists Association, the authors and others involved in this publication from any liability (whatsoever). Commissioning Specialists Association July 1997 Page 3

Introduction This Guidance Note deals with the commissioning of constant flow regulators (also known as automatic balancing valves ) in heating and cooling systems. The constant flow regulator is only one of the methods currently being specified or used by installation contractors as a means of saving time in the commissioning of water distribution systems. Other methods such as Differential Pressure Control Valves are also being used in variable volume systems. It is the responsibility of commissioning engineers to be aware of and responsive to such developments and to adapt to the new technologies becoming available. This Guidance Note is intended as a source of advice to commissioning specialists on the application of Constant Flow Regulators and on problems which may be encountered in their use. Constant Flow Regulators The Constant Flow Regulator (CFR) is a device which maintains a constant flow rate regardless of pressure fluctuations within a water distribution system. The device is either of the cartridge type or of the externally adjustable type, each of which has its advantages and disadvantages. The cartridge type consists of an inner cartridge which is either of stainless steel or plastic construction. The cartridge has special profiles within the sides and end that allow water to flow through it. Flow area is restricted as the differential pressure increases. This is achieved either by a piston compressing against a spring, thus reducing flow area, or a diaphragm rolling action progressively covering the available flow area. flow I.V. return I.V. load A.B.V. Automatic balancing device in circuit The profiled piston type devices react to increasing differential pressure, compressing the spring, which allows the piston to move in the direction of flow thus reducing the annular area around the piston available for the flow. System Design & Device Selection Although the CFR s are installed to remove any need to visit each terminal to adjust the flow, there is still a requirement to measure the flowrates on each branch to check Page 4

that the correct cartridges have been installed. To do this effectively the use of metering stations on main and sub-branches is recommended. CFR s are not affected by turbulence and do not require particular lengths of straight pipe up and down stream so can operate close to a bend, coupling or other fitting. Depending on manufacturer and type, CFR s are selected using a table of flow or set to the required constant flow rate by adjustment of the internal cartridge or are externally adjusted. When using the table of flow rates, the design flow rate required by the designer is unlikely to be matched exactly by the selected cartridge. In such cases, the maximum flow rate of the cartridge should always leave a margin of adjustment over the particular design flow rate required. Where this margin is inadequate the next larger device in the range should be selected. The adjustable cartridge type of device is more dependent on metering stations being installed at strategic points so that the flow rates can be checked. The externally adjustable type can be set from graphs or by simply dialling up the design flowrate once the unit has been installed. Identifying the Device Before any checking of flow rates can be carried out, the devices must be identified and visual confirmation made that they have been installed the correct way round and in the return pipework (see above sketch & pictures following). Installation in the return pipework is generally recommended to reduce the effects of entrained air. The installation should also be checked to ensure that provision has been made for maintenance access. Flushing & Cleaning Flushing and chemical cleaning should be carried out in accordance with BSRIA Application Guide AG8/91 Pre-Commissioning Cleaning of Water Systems. If a flushing by-pass is not included and the system is to be flushed/cleaned, then the cartridges must be removed from the CFR s to allow adequate flushing velocities to be achieved in the system. Manually adjustable valves should be set to the full flow position. NB. One manufacturer s device requires that a separate cap (with no regulating device) is fitted for this exercise Page 5

Common Operating Faults and Remedies Once the system has been successfully flushed and is operating satisfactorily, checks can be made at the metering stations to establish flow rates. If any checked flow rate is not equal to the sum of the set flows of the cartridges on that branch, or the reading is not within the +/- 5% stipulated by the manufacturers, then an investigation to establish which device(s) is not performing correctly has to be carried out to determine the cause. This method will vary depending on individual manufacturer s devices, but a general procedure is as follows: a) Shutting off each individual device in turn and subtracting the design flow for it from the aggregate branch flow rate will indicate the suspect device(s). b) Once the suspect device(s) has been located then the design flowrate for it can be established from the manufacturer s tag. If this corresponds with the schedule that the commissioning engineer is working to, i.e. you have the right device in the right place, it may be that the problem lies within the device itself. c) The next check that should be carried out is to establish the pressure differential across the device, as all of them have a range within which they operate correctly. d) If the pressure differential is within the specified range then the next step is to isolate and drain the section of the system containing the device and remove it for inspection (if the cartridge is of the fixed flow design then the manufacturer s reference on the end of the unit can be compared with those on the tag. If the cartridge is an adjustable type, the setting of the cartridge can be compared with the manufacturer s table). e) If the cartridge and tag match a final check is to test the action of the cartridge by depressing the plunger to ensure that the mechanism is working properly and that the spring is not broken. f) When all of the above have been tried without success the only remaining option is to request a new cartridge from the manufacturer. Page 6

g) Where the flowrate on manually operated devices differs from that shown on the valve or from graphs, it can be adjusted, the flowrate remains unchanged, contact the manufacturer. Trouble Shooting Guide Low flow Low Flow Excessive flow Excessive flow Excessive flow Problem Pressure Differential Cause Less than CFR control range a) Insufficient pump (see table below) duty b) Blocked strainer or other restriction to flow c) Partially closed I.V. Within CFR control range Incorrect or faulty cartridge Incorrect flow, but matching another device of same size. Less than CFR control range Within CFR control range More than CFR control range Within CFR control range a) Cartridge not fitted b) Cartridge fitted the wrong way round. a) Cartridge not pushed fully home against stop. b) Flushing by-pass open c) Incorrect or faulty cartridge Excessive pump head Incorrect cartridge fitted Noisy in operation Chattering in operation More than 200 kpa but less than 414 kpa Fluctuating pressure differential (just under the CFR control range) Fluctuating pressure (within the CFR control range). Higher spring range cartridge needed Pump head too low Excessive air in the system Page 7

CFR Pressure Differential Control Ranges Manufacturer Product No. Control Range Hattersley (Standard cartridges) 1050/1051 17-200kPa Hattersley (High pressure cartridges) 1050/1051 35-414kPa Crane sizes A & C D960 22-200kPa Crane sizes B & D D960 30-410kPa Oventrop Hydromat Q 50-200kPa BREFCO (now by Crane as D970) Flowcon 20-200kPa Page 8