Model Portable Eyewash

Similar documents
Model 9201E Tempered Water Blending System

Model TWBS.SH Tempered Water Blending System

Emergency Shower & Eyewash. Training Guide

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

WEATHERIZING INSTRUCTIONS

Accu-Tab Systems 2000 P Series by Axiall Corporation

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Accu-Tab Systems 1000 Series by Axiall Corporation

Operation and Maintenance Manual

FLANGED TWO-PIECE BALL VALVES

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Installation S Gallon Tank (ASME rated) with Eyewash and Hose Spray

FLANGED TWO-PIECE BALL VALVES

8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER

ROPV R40 E Series User Manual

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

TITAN FLOW CONTROL, INC.

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

BS Series Basket Strainer

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

453 Series Steam Heated Vaporizing Regulator

INSTRUCTIONS PARTS LIST

Sterile Visual Flow Indicator

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation & Instruction Manual For Portable Series R.O. units:

Installation, Operation and Maintenance Manual

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Installation, Operation, and Maintenance Manual

Model ASSEMBLY and OPERATING INSTRUCTIONS

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Pressure Relief Valve Instruction Manual

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

HYDROVEX TTT Membrane Flow Regulator

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Accu-Tab PowerBase 3012AT by Axiall Corporation

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

PC1131 Electric Air Compressor

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

Emergency Eyewash & Shower Testing Program

Adjustable. Unloader Valve. O&M Manual. Part #

J Air and Water Kit Instructions Part# 02584

CF-SERIES HIGH FLOW REGULATORS

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

AIR INLINE METAL SHEAR

D Series Air and Water Kit Part# 02550

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Accu-Tab PowerBase 3070AT by Axiall Corporation

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model No Product Name Handpiece Only Complete System

CSA Sample Draw Aspirator Adapter Operator s Manual

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

8122H AXION Drench / Safety Shower

Yoke Block Instruction Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

CS150 CAP STAPLER OWNER S MANUAL

FLANGED MULTI-PORT BALL VALVES

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy

Installation S S19-788LHS

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

This document to be used with Hurley traditional Davits

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Cocoa Patio Pond with Lit Spillway

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

Geotech 3.5 Reclaimer Installation and Operation Manual

6 digital caliper with case

OPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Geotech 1.66 Reclaimer Installation and Operation Manual

MODEL 1329 Tank Gauge

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 7601.37 Portable Eyewash No. 2080061(17) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 10/17 Model 7601.37 Page 1 of 6

LOCATION OF UNIT: The Model 7601.37 should be placed in close proximity to potential accident areas. It should be clearly identified, free from obstructions and easily accessible. IMPORTANT: Personal wash units shall be protected from freezing, and internal temperatures shall not exceed 38⁰C (100⁰F). Be careful of direct sunlight. WARNING: Use only the handles and the tank skirt when lifting or moving this unit; doing otherwise may damage the unit. NOTICE: Due to differing environments and end user conditions, caution should be observed and the product should be regularly monitored for wear, corrosion, and/or rough service, which can shorten the life of the product. The product should be removed from service if any wear or detrimental service issues occur and should, at minimum, be inspected annually. INSTALLATION INSTRUCTIONS STEP 1: STEP 2: STEP 3: STEP 4: STEP 5: STEP 6: STEP 7: Verify that the tank is depressurized check the pressure gauge and pull up on the relief valve ring. Remove the cover plate on the top of the tank. Use potable water to flush and drain the tank at least twice. Fill the tank with potable water to the top of the water level mark on the tube inside of the tank. A flashlight may be useful to locate the mark. If desired, add Sterile Antimicrobial Preservative Model 9082 as directed (see Step 3 under Maintenance section). Lock the cover plate back in position. Screw the eyewash assembly into the ball valve so that the eyewash is aligned with the push flag. Seal this joint with Loctite 680 (not supplied). Charge the tank with clean compressed air to 100 PSI through the tire-type air valve. The unit is ready for operation. OPERATION INSTRUCTIONS Self-adjusting flow controls assure a constant even flow of.4 gpm, for at least 30 minutes. Instruct all employees in the use of this Portable Emergency Eyewash. Personnel should be assigned to check eyewash liquid level and pressure before any work starts. STEP 1: STEP 2: STEP 3: STEP 4: Lead the injured to the nearest eyewash station. Seconds can make a big difference in preventing serious eye injury. Push the flag to activate the eyewash. Lower head until eyes enter eyewash stream. Use thumbs and forefingers to hold eyelids open so water can flow on surfaces and in folds surrounding eyeballs. Seek qualified medical attention immediately. 10/17 Model 7601.37 Page 2 of 6

MAINTENANCE IMPORTANT: Before refilling the tank with water: Bleed pressure from the tank by pulling the metal ring on the relief valve. Keep hands and face away from the relief valve as it discharges, and wear hearing protection. OR Activate eyewash and allow unit to drain normally. Note that air will continue to escape after the water supply has been exhausted. NOTE: Customer must use the supplied inspection tag to maintain a record of inspection dates and type of maintenance performed (e.g. adding Sterile Antimicrobial Preservative Model 9082, cleaning tank). STEP 1: STEP 2: STEP 3: When water is filled up to the water level mark on the tube inside the tank, the unit weighs approximately 400 lbs. Use good judgment to check the water level. See Step 4 for additional information regarding units that have been activated. Self contained eyewash equipment shall be visually checked to determine if flushing fluid needs to be changed or supplemented. See Step 4 for additional information regarding units that have been activated. Take proper precautions to help prevent the growth of bacteria in the eyewash tank. We recommend either of the following procedures: Procedure A: Use a suitable sterile antimicrobial preservative, such as Haws Model 9082, to help prevent the growth of bacteria in eyewash tank. The tank should be drained, flushed and refilled with potable water and Sterile Antimicrobial Preservative Model 9082 as directed by the preservative s manufacturer. Procedure B: Drain, flush and refill tank with potable water at least once every week. Thoroughly cleanse tank at least once every month. NOTE: Acanthamoeba survive mild chlorination and are commonly found in tap water. Sterile Antimicrobial Preservative Model 9082 will prevent the growth of Acanthamoeba. Hot water, 158⁰F (70⁰C) or hotter will destroy Acanthamoeba but must be allowed to cool prior to use in eyewash units. STEP 4: If tank pressure drops below 95 psi, ensure the following steps are implemented: A. Follow Procedure A or Procedure B of Step 3 above to ensure that water quality is maintained. B. Refill tank with potable water to the watermark line. C. Charge the tank with clean compressed air to 100 PSI through the tire-type air valve. 10/17 Model 7601.37 Page 3 of 6

TROUBLESHOOTING PROBLEM REPAIR CHECKLIST 1. No flow. 1. a. Tank empty. Refill tank. b. Obstruction in line of fitting. Clean obstruction. 2. Poor flow. 2. a. Tighten head assembly. b. Check for obstructions. If necessary, remove eyewash head(s) and clean flow controls. 3. Eyewash flows for less than 15 minutes. 3. a. Fill tank with water up to the water level mark on tube. b. Fill tank with pressurized air to 100 psi. For more information about Haws products, see our website: www.hawsco.com 2017 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 10/17 Model 7601.37 Page 4 of 6

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. ITEM DESCRIPTION PART NO. 1 VALVE, AIR 0006522676 PARTS BREAKDOWN 2 3 4 GAUGE, PRESSURE VALVE, RELIEF COVER, POP-OFF 0002580702 0110000535 9094 5 HEAD, EYEWASH SP12 6 FLOW CONTROL 0012506950 7 SQUEEZE VALVE SP248 12 8 HOSE SP142 9 HEAD EYE/FACE 0002974804 10 VALVE, BALL 0006546340 11 (NOT SUPPLIED, MUST BE ORDERED SEPARATELY) 11 12 STERILE ANTIMICROBIAL PRESERVATIVE INSPECTION TAG 9082 0510000504 2 3 10 9 7 4 5 2X 6 2X 8 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY MODEL(S) PART NUMBER ECN: 5239 VWC DRAWN DATE CHKD 7601.37 REVISION RTM 1/15/97 VWC APPROVED DATE 37 GALLON PORTABLE EW 17 FV 11/23/17 SCALE: 1:12 DRAWING TYPE: PARTS BREAKDOWN SIZE: A SHEET 1 OF 1 WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER. C 2017 Haws Corporation - All Rights Reserved R HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080061 PAGE 5 of 6

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. WALL RELIEF VALVE PRESSURE GAUGE * 27-1/2" 699mm AIR VALVE Ø 18" 457mm 3 6 OF 6 PAGE * 37-3/4" 959mm 33"- 53" 838 mm-1346 mm FLOW PATTERN * 45-3/4" 1162mm TOP VIEW NOTES: 1. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION DIMENSIONS (LOCATIONS), WASTE AND SUPPLY REQUIREMENTS OTHER THAN SHOWN. 2. TO COMPLY WITH ANSI Z358.1-2014 FOR EMERGENCY EYEWASH OR EYE/FACE WASH: EYEWASH OR EYE/FACE WASH SHALL BE POSITIONED SUCH THAT FLUSHING FLUID PATTERN IS NOT LESS THAN 33" (838mm) AND NO GREATER THAN 53" (1346mm) FROM SURFACE ON WHICH USER STANDS; AND 6.0" (153mm) MINIMUM FROM WALL OR NEAREST OBSTRUCTION. 3 EYEWASH HEAD ASSEMBLY MUST BE PARALLEL TO WALL OR OBSTRUCTION TO MEET CRITERIA STATED IN ACCORDANCE TO NOTES 1 AND 2. *4. DIMENSIONS MAY VARY BY ±1/2" (13 mm). 5. PRESSURIZE TO 100 PSI. REFILL IF PRESSURE BECOMES LESS THAN 95 PSI. C 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY: MODEL(S) PART NUMBER ECN: 5239 VWC 0002080061.D DRAWN: DATE: CHK'D.: 7601.37 REVISION RTM 7/24/03 VWC APPROVED: DATE: 37 GALLON PORTABLE EW 17 FV 11/23/17 SCALE: 1:10 DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 1 R 2017 Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.