Safe-T-Stopper. Gas-Free* Service Tee Renewal and Removal for CenterPoint Energy. *In a controlled gas environment

Similar documents
MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

Continental Industries STEEL SERVICE TEES or FAX Visit

Continental Industries TRANSITION FITTINGS or FAX Visit

B-Too Drilling and Tapping Machine

with self-sealing gas valve system

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Hydrostatic Pressure Testing

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

ASSEMBLY & USE MANUAL

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

INSTALLATION INSTRUCTIONS

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series

FIRST TEAM SPORTS, INC Storm Portable Series Assembly Instructions

! CAUTION! ! WARNING! General Information

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

Halsey Taylor Owners Manual

Pressure Dump Valve Service Kit for Series 3000 Units

SIMPLAIR PIPING TOOL. JXT Company

Cyclops + Cyclops + Written By: John Bamford e3d-online.dozuki.com/ Page 1 of 18

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

GILMONT ACCUCAL FLOWMETERS

INSTALLATION & MAINTENANCE INSTRUCTION

Torque Specifications

Dinghy Racers Parts List

Speed control assembly model A-1

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

GIRARD EQUIPMENT, INC. Specialty Valve Manufacturers for Tank Trailers since 1952

RCV-125 REMOTE CONTROL SYSTEM IMPORTANT WARNING FOR SAFER BLAST CLEANING

Steel Spring Driven Reel Instruction Manual

Introduction to Ecoseal

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

CO2 Tank Conversion Kit P.N , P.N , and P.N

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Engineering Data Sheet

RG1200 Service and Repair Manual

Model VR6 System. Installation, Operation & Maintenance

INSERT FITTINGS INSERT FITTINGS

ATS430 turbidity sensor Retractable insertion assembly

E-116 Assembly Guide

Installation Instructions

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

DBML-60/80 Squeeze Tool

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

! WARNING. Before using this product read and understand instructions.

ZIPP VUMAQUAD INSTALLATION INSTRUCTIONS

REV: 03/17. User Manual

Operating Instructions Models and Hydrostatic Test Pumps

LJ1-25 LouieJRtm Tapping Machine

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

RST INSTRUMENTS LTD.

Hydraulic Piston Accumulators

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Detroit Speed, Inc. Rear Coilover Conversion Kit Camaro/Firebird P/N: &

Detroit Speed, Inc. A-body Rear Coilover Conversion Kit A-body (Moser Rear Axle) P/N: , , , , ,

Halsey Taylor Owners Manual STOP!

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Pressure Dump Valve Service Kit for Series 2300 Units

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Air Intake Snorkel Kit

V-24 OXYGEN LANCE VALVE

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

Section 3- Repair and Calibration Procedures

Operation Manual. PEGAS NovoTap, PEGAS NovoTap+

RegO Adapters, Connector, & Fittings

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Ford Service Saddles and Tapping Sleeves

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Tapping Tool RT3422 WARNING! OPERATOR S MANUAL

Operating instruction

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Precision Duct Systems 4570 Commerce Cir SW Atlanta, GA Phone (404)

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

E-118 Assembly Guide

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

Installation/Care/Use Manual

Tri-Tech Medical Inc.

Float Operated Level Controllers

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

OPERATIONS CHALLENGE 2017

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Hydraulic Punch Drivers

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

5k Slickline Lightweight Pressure Control Equipment 4 ID

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Transcription:

Safe-T-Stopper Gas-Free* Service Tee Renewal and Removal for CenterPoint Energy *In a controlled gas environment 1

Presentation Goals What is the Safe-T-Stopper? What are the tool s benefits? What is the typical operation? 2

What is the Safe-T-Stopper and Why? Increase Worker Safety: Now is the time to get away from blowing gas when renewing or removing service tees Stop Doing This! The Safe-T-Stopper is a tool specifically designed for Gas-Free* service tee renewal or removal on open gut pipe tees and street tees. How does it work? The tool assembly mounts on the tee. The plug is removed and an expandable plug is inserted into the throat of the tee or a self tapping plug is inserted directly into the pipe to stop the flow of gas. Once stopped, renewal connections or service cutoffs can now be performed Gas-Free* 3

Safe-T-Stopper Benefits 1. Increase worker safety- No blowing gas when renewing or abandoning services. 2. Reduce excavation cost Only need to uncover the working area of the service and branch. 3. Efficient operation Procedure can be completed within 30-45 minutes. 4. Reduced fitting and labor cost Eliminates stopple and by-pass procedure. 5. Gas-Free* tooling eliminates the need for personal air supply, saving the cost of bottled air. 6. Environmental Stewardship Operation does not release gas into the atmosphere. 7. No blowing gas No wasted services calls from reports of gas odors. Also, keeps good public relations with neighbors. 4

Energy Tee Characteristics Tee Type Open gut ¾ 1-1/4 Street-Tees threaded into a coupling / half coupling welded on a steel main operating at a maximum of 60 psig. Operation Scenarios 1.Hole in the main is either concentric or non-concentric (e.g. burn hole). 2.The location of the main hole is either off-center or the same bore as the coupling I.D 5

Safe-T-Stopper 3000 BV Based on feedback to date, the customized tool package performs service renewal and abandonment operations under gas-free conditions for use on ¾ - 1 ¼ street tee services threaded into a welded steel coupling on steel mains operating at a maximum of 60 psig. The components will allow the following operations: 1. Insert self tapping plug remotely to stop the flow of gas when main hole is concentric. 2.Over-drill the main hole and insert self tapping plug to stop the flow of gas when main hole is nonconcentric, such as a burn hole. 3.Remove street-tee and replace with a plug when main hole is larger than coupling I.D or off-center. 6

Operation performed on a Street-Tee Threaded into a Welded Coupling 7

Street-Tee Threaded into a Welded Coupling Start by loosening the plug with a pipe wrench to break the initial seal. Aluminum ring with integrated rubber o-ring is placed on the boss of the tee. Housing adapter and ball valve are secured with the chain strap on top of aluminum ring creating gas tight seal. 8

Street-Tee Threaded into a Welded Coupling Plug is removed from the tee. Plug adapter with integrated magnet. Using t-handle the plug adapter is lowered onto the square head of the plug, loosened, removed and retracted above the ball valve. Plug removed. Held in place with magnet. 9

Street-Tee Threaded into a Welded Coupling Verify that the hole in the main is concentric using the sight glass attachment, so the low profile self tapping plug can be inserted into the main to stop the flow of gas. Low profile self-tapping plugs available in different sizes. Fine thread made from 4140 steel and nitride hardened Sight Glass PLCS Threadseal mastic is applied to self tapping plug for leak free seal. Self tapping plug insertion tool 10

Street-Tee Threaded into a Welded Coupling If hole in the main is non-concentric (e.g. burn hole), then simply over-drill the existing hole and insert the self-tapping plug. Drill bit Drill assembly Insert self-tapping plug 11

Street-Tee Threaded into a Welded Coupling Once self tapping plug stops the flow of gas, purge remaining gas, cut branch, remove tee and complete operation by tightening malleable plug into coupling. Check for leaks. Self-tapping plug shown in main for illustration. Self tapping plugs have a low profile in main. Completed operation. 12

Street Tee Threaded into a Welded Coupling (Coupling ID and hole in the main are the same or hole is off-center) If the location of the main hole is either off-center or the same bore as the coupling I.D, then an alternative operation is used. Coupling I.D and hole in the main are the same. Hole is off-center 13

Street Tee Threaded into a Welded Coupling (Coupling ID and hole in the main are the same or hole is off-center) Remove Street-Tee plug and insert rubber expansion plug into the throat of the Street-Tee to stop the flow of gas. Expansion plug insertion tool Expansion plug is secured into throat of tee. Assembly is removed. Rubber expansion stopper is inserted into throat of tee and plug is replace. Expansion stoppers available sizes 1/2-2 14

Street Tee Threaded into a Welded Coupling (Coupling ID and hole in the main are the same or hole is off-center) Once expansion stopper is secure in the throat of the tee, completely remove Safe-T-Stopper assembly. Re-install the malleable plug and tighten the plug. Then loosen the tee to only break the initial seal. (Plug must be tighter than tee) Cut branch close to the body of tee and re-build ball valve assembly on top of the tee using the base adapter. Plug tighter than tee Cut branch. Base adapter: Half collars that seal around coupling. 15

Street Tee Threaded into a Welded Coupling (Coupling ID and hole in the main are the same or hole is off-center) Remove tee with plug removal adapter. Plug removal adapter. Plug removal adapter removes the tee Gas-Free. Tee removed. 16

Street Tee Threaded into a Welded Coupling (Coupling ID and hole in the main are the same or hole is off-center) After tee removal, tighten plug into coupling using plug insertion adapter. Remove assembly and tighten plug with a pipe wrench to complete the operation. Plug insertion adapter Completed operation 17

Street Tee Threaded into a Welded Coupling (Coupling ID and hole in the main are the same or hole is off-center) When performing the tee removal process, the original assembly used a rubber saddle that was fitted on the main. Leaks occurred at the apex of the main between the main and saddle. Rubber Saddle (original design) Leak 18

Street Tee Threaded into a Welded Coupling (Coupling ID and hole in the main are the same or hole is off-center) SOLUTION: A custom rubber gasket used with a set of steel half collars for sizes 3/4-1-1/4, tightened around the coupling to provide the seal. The entire assembly is rigid and held secure by the chains. Rubber gasket is fitted over tee and placed around coupling. Hex wrench tightens collar. Gasket and half collars are fitted around the coupling. Shown without tee for illustration only. Half Collars 19

Contact For more information about the Safe-T-Stopper and other gas distribution products contact: Mazco Products & Services Ltd. 32 Adamic Crescent Leduc, AB T9E 5H9 780-690-7504 ivan@mazcoproducts.com www.mazcoproducts.com 20