NIOSH CERTIFIED FEATURES DUAL APPLICATIONS SUITABLE FOR WELDING APPLICATIONS

Similar documents
8000 SERIES FACEPIECE ASSEMBLY FACEPIECE REPLACEMENT CARTRIDGES 1 ORGANIC VAPORS ACID GASES ORGANIC VAPORS/ ACID GASES AMMONIA/METHYLAMINE

Maintenance Made Simple Fewer replacement parts and super-simple disassembly make cleaning and maintaining the 7000 Series easy.

9000 SERIES FULL FACE RESPIRATORS

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

A. APPLICATIONS 1. WARNING TO USER

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference)

8214/8514/07187 Respirator N95 Particulate

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference)

Nuisance level organic vapor relief* User Instructions (Keep insert for reference)

RESPIRATOR HALFMASK AIR-PURIFYING 7700 SERIES SILICONE HALF MASK CARRY BAG. features and benefits

9210/37021, 9211/37022* Particulate Respirator N95

8200/07023 Particulate Respirator N95

Differentiation in a me-too marketplace.

Particulate Respirator N95

VFlex 9105/9105S Particulate Respirator N95

T R A I N - T H E - T R A I N E R

8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating

Maintenance Made Simple Fewer replacement parts and super-simple disassembly make cleaning and maintaining the 7000 Series easy.

3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference)

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

North RU8500 Series Half Masks

Respiratory Protection

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

3M Half and Full Facepiece Respirators. Unsurpassed comfort. Maximum versatility. 3Innovation

low maintenance respirator

Respiratory Protection Training

BREATHE SAFELY: The Proper Use of Respiratory Protection

Technical. Datasheet. 3M 6000 Series Reusable Full Face Masks. Applications. Product Description. Key Features

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Technical. Datasheet 3M Reusable Half Face Respirator 6000 Series. Main Features. Applications

Phalanx Alpha Phalanx Beta and Ultra Elite

Breathe easily. Weld safely. 3M Disposable and Reusable Respirators for Welding

What type of particles are in your environment? Is the environment hot and humid or is additional worker comfort desired?

"RESPIRATORY PROTECTION AND SAFETY"

Standards of Practice Respiratory Protection: Appendix C

Respiratory Protection for Producers

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

3 Choosing the Right Respirator

The Following information is based on material prepared by the American Lung Association

Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece

Respiratory Protection Self Inspection Checklist

Datasheet. Technical. 3M 6000 Series Full Face Masks. Main Features

Datasheet. Technical. 3M 6000 Series Reusable Half Masks. Main Features. Applications

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

Technical. Datasheet 3M Reusable Half Face Respirator 7500 Series. Main Features. Applications

3M Occupational Health and Environmental Safety Division. Options

A. Evaluation of the written program

Ontario Operations PMP - Daily Safety Message. Respirator Safety

Respiratory Protection Self-Inspection Checklist

Respiratory Protection

Respiratory Protection Program 29CFR

Section 3. Respiratory Protection Plan (SPPM 3.24)

In addition to the responsibility for managing the elements of the respiratory protection program, he/she will be responsible for:

RESPIRATORY PROTECTION

SOTR Special Operations Tactical Respirator

Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece

EP30g, Respiratory Protection.pdf

Respiratory Protection Basics

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

Barry Sanders has the following disclosures to make:

USE INSTRUCTIONS SCOTT HEALTH AND SAFETY PROMASK 25 FULL FACEPIECE RESPIRATOR USE INSTRUCTIONS

Respiratory Protective Equipment Program Appendix A - Definitions and Key Terms

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

RESPIRATORS & FIT TESTING

Respiratory Protection

The Operations Supervisor, is responsible for overall implementation, management and support of our Respiratory Protection Program.

Respiratory Protection. Program

Respiratory Protection in Agriculture

Fire Escape Hood OPERATION AND INSTRUCTIONS

Respiratory Protection Program

RESPIRATORY PROTECTION PROGRAM

Respiratory Protection

Helping protect people At work, at home, for life

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

Don t Forget About Fit What You Need to Know About Respirator Fit-testing

"RESPIRATORY PROTECTION AND SAFETY"

Head Cover BE-12 Series

University of Dayton Respiratory Protection Program 29 CFR

RMM 311 Respiratory Protection Program Page 2 March 2013

HOW TO USE A RESPIRATOR

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

3M Select Software United Kingdom and Ireland

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR PERSONS CONDUCTING A BUSINESS OR UNDERTAKING

RESPIRATORY PROTECTION PROGRAM

Using a Filtering Facepiece Respirator

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11

Respiratory Protection Program

Respiratory Protection Programs Policy

San Mateo County Health System Environmental Health Services Division. Respirator Use

Respiratory Protection

Respiratory Protection For Pesticides

3M TM Full Face Respirator 6000 Series - Schematic

Farm Respiratory Protection 1

Transcription:

NIOSH CERTIFIED N95 Particulate Filter Disk is NIOSH certified to have a filter efficiency level of 95% or greater against non-oil based particulate aerosols up to 10x PEL. Plus relief from nuisance levels (less than OSHA Permissible Exposure Limit) of Organic Vapor Odors and Ozone. DUAL APPLICATIONS Use the 8755 N95 or the 8757 N95 Particulate Filter with the 8900 Filter/Disk Holder for standalone particulate filter aplications. SUITABLE FOR WELDING The N95 Particulate Filters are suitable for most welding applications. Use the 8755 N95 Filter or the 8757 when nuisance levels of OV/Ozone are present. FEATURES 100% PVC-Free. N95 Particulate Filter Disk is lighter than traditional filter cartridge. Suitable for most welding applications; fits under most welding helmets. Use N95 Particulate Filters as a prefilter or as a standalone particulate filter. Wider field of vision because of low profile. Fiberglass-free filters. No plastic casing to throw away. APPLICATIONS Welding, Grinding, Lime, Metal Machining, Aluminum Processing, Bagging, Brazing, Buffing, Cement Work, Dusty Environments, Foundries, Metal Working, Mining, Polishing, Poultry, Sanding, Soldering, Stone Quarrying, Sweeping, Textiles, Torch Cutting, Waste Processing/Recycling. Ideas that wear well.

USE AGAINST 1. Contaminants specified on NIOSH approval label on bag, cartridges, disks/filters/prefilters or instruction manual. 2. Contaminants with good warning properties, i.e. smell, taste or irritation. DO NOT USE AGAINST 1. Concentrations of contaminants which are unknown, or are immediately dangerous to life or health. 2. Concentrations of contaminants which exceed the maximum use concentration or 10 times the OSHA Permissible Exposure Limit, whichever is lower. 3. Gases or vapors with poor warning properties or those which generate high heats of reaction or paint sprays containing isocyanates, or sandblasting. 4. Oil-based mists with N filters. RESTRICTIONS 1. This respirator does not supply oxygen and must not be used in atmospheres containing less than 19.5% oxygen. 2. Do not remain in contaminated area if any physical distress occurs, for example breathing difficulty, dizziness or nausea. 3. Leave contaminated area and replace respirator, cartridge, or disk/filter/prefilters if, it is damaged, distorted, a proper fit cannot be obtained, you taste, smell or become irritated by contaminants, or breathing becomes difficult. 4. Do not alter, modify, or abuse this respirator, cartridge, disk, filter, or prefilter. 5. Store respirator in sealed bag in a clean, dry, non-contaminated area. 6. Dispose of facepiece, and/or cartridges and prefilters, according to your employer s policy and local regulations. 7. Prefilters are required for dusts and mists. 8. Where oil mists may be present in the work area replace R and P filters or prefilters no later than eight hours after first use. Do not exceed 10x PEL or a total of 200 mg loading per respirator, whichever is lower. It is the users responsibility to know the PEL and concentration of the contaminant, the maximum workrate of the employee, and any other worksite specific information to calculate the loading of the filter. 9. Dispose all filters and prefilters no later than thirty days after first use. 10. Use filters before the use by expiration date printed on box. 11. If used for welding, use appropriate eye and face protection. PACKAGING 8755 N95 Particulate Filter Plus 8757 N95 Assembled Nuisance Ozone/Organic Vapors Respirator, Medium 1 Pair per Bag 1 Pair per Bag 50 Bags per Case 12 Bags per Case 8900 Disk Filter Holder 1 Pairs per Bag 5 Bags per Box 6 Boxes per Case SELECTION GUIDE Check 8000 Selection Guide for full line of facepieces, cartridges, pre-assembled respirators with cartridges, filters and prefilters, and NIOSH approvals and limitations. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER This limited warranty is made in lieu of the warranties of merchantability, fitness for particular purposes and all other warranties, express or implied. There are no other warranties which extend beyond the description on the face hereof. The physical standards and specifications of Moldex will be met by products sold. Exclusive Remedies: damages for the breach of this limited warranty are limited to the replacement of such quantity of Moldex products proved to be defectively manufactured. Except as provided above, Moldex shall not be liable or responsible for any loss, damages, or liability, direct, indirect, incidental, special or consequential, arising out of a sale, use or misuse, or the inability to use products by the user.! WARNING TO USER 1. Follow all instructions and warnings on the use of these respirator filters and wear during all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection and may result in sickness or death. 2. For proper use, ask your supervisor or phone 3. Before use, the user must first be trained by the employer in proper respirator use in accordance with applicable safety and health standards for the contaminant and exposure level in the assigned work area. 4. The vapors, gases. dusts, mists, fumes and other contaminants which can be dangerous to your health include those which you cannot see, taste, or smell. 5. Check with your supervisor for the appropriate cartridges and/or filters for the contaminants in your work area. Ideas that wear well.

NIOSH CERTIFIED All Moldex Particulate Filters are NIOSH certified.the 8940 P100 Particulate Filter has an efficiency level of 99.97% or greater against both oil & non-oil based particulate aerosols. The 8970 R95 Particulate Filter has an efficiency level of 95% or greater against both oil & non-oil based particulate aerosols. The 8755 and 8910 N95 Particulate Filters are 95% efficient against non-oil based particulate aerosols only. The 8755 also offers relief from nuisance levels of OV/Ozone. DUAL APPLICATIONS Use the P100 Particulate Filter Disk, R95 Particulate Filter or the N95 Particulate Filters with the 8900 Filter Disk Holder for standalone particulate filter applications. Or use in combination with any 8000 Series Gas/Vapor Cartridge. Use the 8020 Filter Retainer with the 8970 R95 Particulate Filter or 8910 N95 Particulate Filter for prefilter applications. Use the 8920 Piggyback Adapter with the 8940 P100 Particulate Filter Disk. SUITABLE FOR WELDING The P100, R95 and N95 Particulate Filters are suitable for most welding applications. Use the 8755 N95 Filter when nuisance levels of OV/Ozone are present. P100 APPLICATIONS For contaminants falling under an OSHA substance specific standard requiring a High Efficiency Particulate Air (HEPA) filter. These substances include asbestos, lead, inorganic arsenic and cadmium. Also for use in environments where oil-based particulates are present. FEATURES 100% PVC-Free. P100 Particulate Filter Disk is lighter than traditional Filter Cartridge. Piggyback P100 with Moldex 8000 Gas/Vapor Cartridges or use standalone filter. P100 and R95 can be used for both oil and non-oil based particulates. Use P100, R95 or N95 Particulate Filters as a prefilter or as a standalone particulate filter. Wider field of vision because of low profile. Fiberglass-free filters. No plastic casing to throw away. N95 APPLICATIONS Welding, Grinding, Lime, Metal Machining, Aluminum Processing, Bagging, Brazing, Buffing, Cement Work, Dusty Environments, Foundries, Metal Working, Mining, Polishing, Poultry, Sanding, Soldering, Stone Quarrying, Sweeping, Textiles, Torch Cutting, Waste Processing/Recycling. Ideas that wear well.

USE AGAINST: 1. Contaminants specified on NIOSH approval label on bag, cartridges, disks/filters/prefilters or instruction manual. 2. Contaminants with good warning properties, i.e. smell, taste or irritation. DO NOT USE AGAINST: 1. Concentrations of contaminants which are unknown, or are immediately dangerous to life or health. 2. Concentrations of contaminants which exceed the maximum use concentration or 10 times the OSHA Permissible Exposure Limit, whichever is lower. 3. Gases or vapors with poor warning properties or those which generate high heats of reaction or paint sprays containing isocyanates, or sandblasting. 4. Oil-based mists with N filters. RESTRICTIONS 1. This respirator does not supply oxygen and must not be used in atmospheres containing less than 19.5% oxygen. 2. Do not remain in contaminated area if any physical distress occurs, for example breathing difficulty, dizziness or nausea. 3. Leave contaminated area and replace respirator, cartridge, or disk/filter/prefilters if, it is damaged, distorted, a proper fit cannot be obtained, you taste, smell or become irritated by contaminants, or breathing becomes difficult. 4. Do not alter, modify, or abuse the respirator, cartridge, disk, filter, or prefilter. 5. Store respirator in sealed bag in a clean, dry, non-contaminated area. 6. Dispose of facepiece, and/or cartridges and prefilters, according to your employer s policy and local regulations. 7. Prefilters are required for dusts and mists. 8. Where oil mists may be present in the work area replace R and P filters or prefilters no later than eight hours after first use. Do not exceed 10XPEL or a total of 200 mg loading per respirator, whichever is lower. It is the users responsibility to know the PEL and concentration of the contaminant, the maximum workrate of the employee, and any other worksite specific information to calculate the loading of the filter. 9. Dispose all filters and prefilters no later than thirty days after first use. 10. Use filters before the use by expiration date printed on box. 11. If used for welding, use appropriate eye and face protection. PACKAGING 8941-SM, 8942-MED 8943-LG 8940 P100 Particulate Filter P100 Assembled Respirator 1 Pair per Bag 1 Per Bag 5 Pairs per Box 12 Per Case 6 Boxes per Case 8970 R95 Particulate Filter 8910 N95 Particulate Filter 5 Pairs per Bag 10 Bags per Case 8900 Disk Filter Holder 8920 Filter Disk Piggyback Adapter 8020 Prefilter Retainer 1 Pair per Bag 1 Pair per Bag 5 Bags per Box 10 Bags per Box 6 Boxes per Case 5 Boxes per Case SELECTION GUIDE Check 8000 Selection Guide for full line of facepieces, cartridges, pre-assembled respirators with cartridges, filters and prefilters, and NIOSH approvals and limitations. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER This limited warranty is made in lieu of the warranties of merchantability, fitness for particular purposes and all other warranties, express or implied. There are no other warranties which extend beyond the description on the face hereof. The physical standards and specifications of Moldex will be met by products sold. Exclusive Remedies: damages for the breach of this limited warranty are limited to the replacement of such quantity of Moldex products proved to be defectively manufactured. Except as provided above, Moldex shall not be liable or responsible for any loss, damages, or liability, direct, indirect, incidental, special or consequential, arising out of a sale, use or misuse, or the inability to use products by the user.! WARNING TO USER 1. Follow all instructions and warnings on the use of these respirator filters and wear during all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection and may result in sickness or death. 2. For proper use, ask your supervisor or phone 3. Before use, the user must first be trained by the employer in proper respirator use in accordance with applicable safety and health standards for the contaminant and exposure level in the assigned work area. 4. The vapors, gases. dusts, mists, fumes and other contaminants which can be dangerous to your health include those which you cannot see, taste, or smell. 5. Check with your supervisor for the appropriate cartridges and/or filters for the contaminants in your work area. Ideas that wear well.

8000 SERIES RESPIRATOR APPROVED COMBINATIONS GAS/VAPOR 8001 Small 8002 Medium 8003 Large CARTRIDGES 8100 Organic Vapors 8200 Acid Gases 8300 Organic Vapors/Acid Gases 8400 Ammonia/Methylamine 8500 Formaldehyde 8600 Multi Gas/Vapor Smart Cartridge PAINT SPRAY/PESTICIDE (R95 for both oil & non-oil based particulates) (N95 for non-oil based particulates only) 8001 Small 8002 Medium 8003 Large 8100 ORGANIC VAPOR CARTRIDGE PARTICULATE FILTERS 8970 R95 Particulate Filter 8910 N95 Particulate Filter 8020 RETAINER P100 PARTICULATE FILTER DISK OR P100 CARTRIDGE STANDALONE 8001 Small 8002 Medium 8003 Large P100 FILTER DISK/CARTRIDGE 8940 P100 Particulate Filter Disk 8990 P100 Particulate Cartridge (8900 Filter/Disk Holder is not required with 8990) 8900 FILTER/DISK HOLDER including RETAINER RING

GAS/VAPOR CARTRIDGES PIGGYBACKED WITH P100 PARTICULATE FILTER/DISK 8001 Small 8002 Medium 8003 Large CARTRIDGES 8100 Organic Vapors 8200 Acid Gases 8300 Organic Vapors/Acid Gases 8400 Ammonia/Methylamine 8500 Formaldehyde 8600 Multi Gas/Vapor Smart Cartridge P100 FILTER DISK 8940 P100 Particulate Filter Disk 8920 FILTER DISK ADAPTER including RETAINER RING PARTICULATE STANDALONE WITH N95 OR R95 FILTERS 8001 Small 8002 Medium 8003 Large PARTICULATE FILTERS 8910 N95 Particulate Filter (non-oil based only) 8755 N95 Particulate Filter Plus Nuisance Levels OV/Ozone 8970 R95 Particulate Filter (R95 for both oil & non-oil based particulates) 8900 PARTICULATE FILTER/DISK HOLDER including RETAINER RING GAS/VAPOR CARTRIDGES WITH N95 PARTICULATE FILTER OR R95 PARTICULATE FILTER 8001 Small 8002 Medium 8003 Large CARTRIDGES 8100 Organic Vapors 8200 Acid Gases 8300 Organic Vapors/Acid Gases 8400 Ammonia/Methylamine 8500 Formaldehyde 8600 Multi Gas/Vapor Smart Cartridge 8020 RETAINER PARTICULATE FILTERS 8910 N95 Particulate Filter (non-oil based only) 8970 R95 Particulate Filter (R95 For both oil & non-oil based particulates)

8000 RESPIRATOR SELECTION GUIDE 8000 SERIES ASSEMBLY DESCRIPTION PACKAGING MODEL # SIZE Includes head strap assembly and exhale valve assembly. 1 Facepiece/Bag 12 Bags/Case 8001 8002 8003 S M L REPLACEMENT CARTRIDGES 1 HAZARD APPROVAL MODEL # PACKAGING ORGANIC VAPORS Organic Vapors. TC-23C-1223 8100 1 PR/BAG ACID GASES Chlorine, Hydrogen Chloride, Sulfur Dioxide, or Chlorine Dioxide; or for escape only from Hydrogen Sulfide; or Hydrogen Fluoride. ORGANIC VAPORS/ ACID GASES Organic Vapors, Chlorine, Hydrogen Chloride, Sulfur Dioxide, or Chlorine Dioxide; or for escape only from Hydrogen Sulfide; or Hydrogen Fluoride. AMMONIA/METHYLAMINE Ammonia/Methylamine. Use with gas-proof goggles. TC-23C-1224 8200 1 PR/BAG TC-23C-1225 8300 1 PR/BAG TC-23C-1369 8400 1 PR/BAG FORMALDEHYDE Formaldehyde. OSHA regulations require gas-proof goggles. TC-23C-1409 8500 1 PR/BAG MULTI GAS/VAPOR Organic Vapors, Ammonia, Methylamine, Chlorine, Hydrogen Chloride, Sulfur Dioxide, or Hydrogen Fluoride, or Chlorine Dioxide, or Formaldehyde, or Hydrogen Sulfide (escape only). TC-23C-1809 8600 1 PR/BAG P100 PARTICULATES Dusts, Fumes, Mists Radionuclides, Radon daughters and Asbestos-containing dusts and mists. TC-84A-1443 8990 1 PR/BAG 1 Refer to NIOSH label for approval limitations, see Instruction Manual and/or packaging.

8000 RESPIRATOR SELECTION GUIDE ASSEMBLED RESPIRATORS WITH CARTRIDGES OR P100 DISKS 1 HAZARD APPROVAL MODEL # SIZE ORGANIC VAPORS Organic Vapors. TC-23C-1223 8101 8102 8103 S M L PAINT SPRAY/PESTICIDE (includes 8910 N95 prefilters, 8020 retainers, 8100 cartridges) Paint, Lacquer, and Enamel Mists, Pesticides, Organic Vapors, and Dusts and Mists. Waterbased Only. Not for use against two-part isocyanate paints or oil based particulates. MULTI GAS/VAPOR Organic Vapors, Ammonia, Methylamine, Chlorine, Hydrogen Chloride, Sulfur Dioxide, or Hydrogen Fluoride, or Chlorine Dioxide, or Formaldehyde, or Hydrogen Sulfide (escape only). P100 PARTICULATES Facepiece assembly with P100 disk #8940 and Disk/Filter Holder #8900. TC-84A-1337 TC-23C-1809 TC-84A-0117 8111N 8112N 8113N 8601 8602 8603 8941 8942 8943 S M L S M L S M L PAINT SPRAY/PESTICIDE KIT With Free Paint Bucket 1 8000 Series Facepiece Assembly, 5 pairs 8910 N95 Prefilters, 1 8020 Filter Retainer, 1 pair SparkPlugs TC-84A-1337 8111KN 8112KN 8113KN S M L N95 Welding Particulates Plus Nuisance levels of OV/Ozone Facepiece assembly w/n95 filter #8755 and Disk/Filter Holder #8900 TC-84A-3901 8757 M PACKAGING: 1 Fully assembled respirator with cartridges and/or filters per resealable bag, 12 respirators/case. 1 Refer to NIOSH label for approval limitations, see Instruction Manual and/or packaging. PREFILTER RETAINER, HOLDER, AND ADAPTER HAZARD MODEL # PREFILTER RETAINER 8020 Use with 8910 or 8970 and 8000 Series Cartridges. DISK/FILTER HOLDER with retainer ring use with 8001, 8002, 8003 facepiece assemblies and 8910, 8970, 8755 or 8940. DISK PIGGYBACK ADAPTER with retainer ring use with 8000 series cartridges and 8940. 8900 8920 PACKAGING 1 PR/BAG 10 PRS/BOX 5 BXS/CASE 1 PR/BAG 6 BXS/CASE 1 PR/BAG 6 BXS/CASE

8000 RESPIRATOR SELECTION GUIDE 8900 SERIES FILTERS AND DISKS 1 HAZARD APPROVAL MODEL # PACKAGING P100 PARTICULATES Dusts, Fumes, Mists, Radionuclides, Radon daughters and Asbestoscontaining dusts and mists. TC-84A-0117 8940 1 PR/BAG 6 BXS/CASE N95 PARTICULATE FILTER Use with 8020 retainer and 8000 Series cartridges, or standalone with 8900 holder. R95 PARTICULATE FILTER Use with 8020 retainer and 8000 Series cartridges, or standalone with 8900 holder. N95 WELDING PARTICULATE FILTER PLUS NUISANCE OV/OZONE Use as standalone with 8900 holder. TC-84A-1343 8910 5 PRS/BAG 10 BGS/CASE TC-84A-4248 8970 5 PRS/BAG 10 BGS/CASE TC-84A-3901 8755 1 PRS/BAG 50 BGS/CASE 1 Refer to NIOSH label for approval limitations, see Instruction Manual and/or packaging. REPLACEMENT PARTS 2 DESCRIPTION MODEL # PACKAGING HEAD STRAP ASSEMBLY Includes yoke, buckles and 2 straps. 0082 4/BAG 5 BGS/CASE EXHALE VALVE ASSEMBLY Includes holder and diaphragm. 0083 6/BAG 5 BGS/CASE 2 Use with 8001, 8002, 8003 Assembled Facepiece. 8000 FIT TEST PRODUCTS PART # DESCRIPTION PACKAGING 8006 PROBED CARTRIDGE KIT 1 PER BOX INCLUDES: 1 8006 probed cartridge, 1 pair 8940 P100 Particulate Disk, 1 pair 8900 disk holders, 1 pair 8920 disk piggyback adaptors, and instructions. For use with TSI PortaCount. 8007 ALCOHOL WIPES TRAINING AND INSTRUCTIONAL MATERIAL 0701 HOW TO SET UP A RESPIRATORY PROTECTION PROGRAM According to OSHA guidelines 100 WIPES PER BOX

Moldex offers comprehensive training materials and programs on the use and care of 8000 series respirators to help you meet OSHA, state and local regulations. FIT TESTING Improve your respirator program with Moldex s qualitative fit test kit and Probed Cartridge Kit for quantitative fit testing. Make sure your worker s respirators fit satisfactorily. And ensure that your workers are wearing their respirators properly. Moldex s Fit Test Kits will help your respirator program meet OSHA requirements. RESPIRATOR TRAINING PROGRAMS FACTORY-BACKED SUPPORT GROUP Moldex s factory-trained sales force is available to help you and your workers take full advantage of the 8000 series respirator s many safety and value features. In addition, there are training materials available to help ensure the proper use of 8000 series respirators. TECHNICAL SERVICE HELP LINE A toll-free technical service line to help answer your questions about respiratory protection and the use of all Moldex safety products.

IMPORTANT NOTICE TO USERS Read Instruction Manual, included with 8000 respirator facepiece, before wearing. You are responsible to understand and follow all warnings, restrictions and other information contained in the Instruction Manual. Failure to do so may result in sickness or death. USE AGAINST 1. Contaminants specified on NIOSH approval label or bag or cartridges or filters and in Manual. 2. Contaminants with good warning properties, i.e. smell, taste or irritation. DO NOT USE AGAINST 1. Concentrations of contaminants which are unknown, or are immediately dangerous to life or health. 2. Concentrations of contaminants which exceed the maximum use concentration or 10 times the OSHA Permissible Exposure Limit, whichever is lower. 3. Gases or vapors with poor warning properties or those which generate high heats of reaction, or paint sprays containing isocyanates, or sandblasting. 4. Oil-based mists with N filters. WARNING TO USER 1. Follow all instructions and warnings on the use of these cartridges and respirator and wear during all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection, and may result in sickness or death. 2. For proper use, ask your supervisor or phone 3. The user must first be trained by the employer in proper respirator use, in accordance with applicable safety and health standards, for the contaminant and exposure level in the assigned work area. 4. The vapors, gases, dusts, mists, fumes, and other contaminants which can be dangerous to your health include those which you cannot see, taste, or smell. 5. Check with your supervisor for the appropriate cartridges and/or filters for the contaminants in your work area. RESTRICTIONS: 1. This respirator does not supply oxygen and must not be used in atmospheres containing less than 19.5% oxygen. 2. Do not remain in contaminated area if any physical distress occurs, for example breathing difficulty, dizziness or nausea. 3. Leave contaminated area and replace respirator and/or cartridge or filter if it is damaged, distorted, a proper fit cannot be obtained, you taste, smell or become irritated by contaminants, or breathing becomes difficult. 4. Do not alter, modify, or abuse the respirator, cartridge and/or filter. 5. Store cartridges, filters and respirator in sealed bag in a clean, dry, non-contaminated area. 6. Dispose of facepiece, and/or cartridges and disks/filters, according to your employer s policy and local regulations. 7. Filters are required for particulates. 8. Where oil mists are present, either alone or in combination with solid particulates, do not use the R or P filters for longer than one eight-hour work shift. Dispose no later than eight hours after first use. Do not exceed 10XPEL or a total of 200 mg loading per respirator, whichever is lower. It is the user s responsibility to know the PEL and concentration of the contaminant, the maximum workrate of the employee, and any other worksite specific information to calculate the loading of the filter. Where oil mists are present do not use N filters. 9. Where oil mists are not present, dispose of all cartridges, N, R, P filters, no later than thirty days after first use. 10. Use cartridges, filters, and facepieces before the use by expiration date printed on box. TECHNICAL SERVICE LINE Moldex maintains a toll-free Technical Service Line to answer questions about the use of Moldex respirators, contaminants and regulations.

FITTING INSTRUCTIONS FOR MOLDEX 8000 SERIES HALFMASK RESPIRATOR YOUR LUNGS DESERVE ALL THE PROTECTION THEY CAN GET. Place respirator under the chin and pull the cradle to the top of head, so it rests on the crown. Attach the bottom straps behind the neck. Adjust both straps to obtain a secure and comfortable fit. Tighten by pulling on ends, or loosen by pushing out on buckle tab. Seal check your respirator each time you enter a contaminated area. Positive Pressure Seal Check: Cover the exhalation valve vents, and exhale gently to create a slight positive pressure. If air leakage is detected, re-adjust the position of the facepiece and the tension of both headstraps, and repeat the seal check until leakage is eliminated.! WARNING Negative Pressure Seal Check: Cover both cartridges, and gently inhale and hold your breath. The facepiece should slightly collapse. If air leakage is detected, re-adjust the position of the facepiece, and the tension of both headstraps, and repeat the seal check until leakage is eliminated. Failure to follow all instructions and warnings on the proper use of this respirator, each time it is worn, may reduce respirator effectiveness, wearer protection and may result in sickness and/or death. It is the user s responsibility to obtain a proper fit. If you cannot obtain a proper fit, do not enter the contaminated area. OSHA Regulation 1910.134 (f) requires that the user be fit tested before being assigned a respirator. Do not wear with any facial hair, which may prevent the respirator from fitting properly, such as beards or long sideburns.