Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Similar documents
Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

D The plus that makes all the difference DRÄGER FABIUS PLUS

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

D The specialist for every environment DRÄGER FABIUS TIRO

D The plus that gives you more DRÄGER FABIUS PLUS

Fabius MRI. From specialists for specialists. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

MT Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger Fabius GS premium Anaesthesia Workstations

Dräger Fabius Tiro Anaesthesia Workstations

Dräger Fabius plus XL Anaesthesia Workstations

D Your personal anesthesia assistant DRÄGER PRIMUS. Dräger. Technology for Life

A9600 Anesthesia Workstation. Your healthcare, we care.

The centerpiece of a comprehensive anaesthesia workstation

Anesthesia Workstation

Aespire 7100 Essential performance Compact design

Primus Anaesthesia Workstations

D Reliability goes XL

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger Savina Sub-Acute Care Ventilation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Your patients, our primary focus. Siesta i Whispa anesthesia machine

State-of-the-art anesthesia technology

Oxylog VE300 Emergency & Transport Ventilation

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

The anaesthesia workstation focused on you

Anes Machine Use and Pre-use Check - CA1 focus

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Anesthesia Machine Intro

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Dameca MRI 508. State-of-the-art MRI technology

Safe Accurate Reliable. CWM-301 Anesthesia System

Your patients, our primary focus

Oxylog 3000 plus Emergency & Transport Ventilation

MT Excellent performance and reliability EVITA 4 EDITION

An intuitive and innovative answer to your anaesthesia challenges

Vamos / Vamos plus Anaesthetic Gas Monitors

GE Healthcare. Aestiva/5. More than superior ventilation

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Hallowell EMC Anesthesia WorkStation Operating Manual

Dräger coaxial breathing circuits Consumables and Accessories

Resuscitaire Neonatal Open Care

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

The anaesthesia workstation focused on you

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Siesta i Whispa Integrated technology

Multi-Gas Analyzer. Multi-Gas Analyzer bcgroupintl.com. Features - MGA MGA-3050 Multi-Gas Analyzer

Oxylog 2000 plus Emergency & Transport Ventilation

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

APUS Anesthesia Machines

DATA SHEET. VENTILATION SERVO-s

Hospital and Transport for Controlled Breathing

Made to meet your needs DRÄGER SAVINA 300

D Designed for non-invasive ventilation DRÄGER CARINA

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

D Quality and Precision you can Trust in Oxygen Administration CONVENTIONAL FLOWMETER DIGITAL FLOWMETER COMPACT FLOWMETER

Dräger Carina Sub-Acute Care Ventilation

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger Carina Sub-Acute Care Ventilation

Emergency Transport and Ventilation

Better to have one OXYLOG 3000

Technical Data and Specifications

Blease900 Ventilator PATIENT CENTERED VENTILATION

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger RZ 7000 Test Equipment

Focused on essentials DRÄGER SAVINA 300

D Rising up to the challenge OXYLOG 3000 PLUS

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Draeger Fabius GS Pre-Use Check

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

MT The secret of harmonious breathing BABYLOG 8000 PLUS

Flow meter. bellow vaporizer. APL valve. Scavenging system

Experience the Flow. Streamlined workflow with the compact Flow-c

Dräger RZ 7000 Test Equipment

D Beyond essentials DRÄGER SAVINA 300 SELECT

Anaesthesia as advanced as your MRI FABIUS MRI

Panther 5 Acute Care Ventilator

Dräger NITROX 200 Diving Equipment

SERVO-s v8.0 Data sheet

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Dräger Quaestor 7000 Test Equipment

Setting new trends in ventilation. DRÄGER EVITA INFINITY V500

Anesthesia. Midmark Animal Health Products

Redefining Anaesthesia DRÄGER ZEUS INFINITY EMPOWERED

Supporting your patients every breath

Recommendations on Checking Anaesthesia Delivery Systems

Operation and Maintenance of the EPV200 Portable Ventilator

Airox Supportair Ventilator

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

INTENSIVE CARE VENTILATORS

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Dräger PAS Micro Short Term Breathing Apparatus

D Accessories that actively cooperate DRÄGER INFINITY ID-ACCESSORIES

Transcription:

Fabius Tiro TM Designed for your environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care

Traditional hospital ORs have their needs... With more surgical procedures being performed outside of the traditional OR setting each year, Dräger recognized the need to recruit a specially designed system into our CareArea TM OR/Anesthesia portfolio. Fabius Tiro TM * represents our commitment to meet the unique and changing needs of non-traditional locations, by making the latest technology available at a fraction of the cost: Same technology and performance as our other popular systems in a compact design Intuitive operation and layout ensures ease of use and a short learning curve Ample illuminated workspace Communication with automated record keeping systems like the Dräger Medical Innovian TM Anesthesia Solution for enhanced patient throughput Convenient compact breathing system (COSY): Fresh gas decoupled for tidal volume delivery unaffected by fresh gas flow adjustments Simplified design allows easy disassembly for sterilization of all components in contact with patient gas Pivot and height adjustment allow convenient positioning of breathing system Dräger E-Vent piston-based ventilator is the latest in precision anesthesia ventilation technology. Electronically driven and controlled, the E-Vent provides significant advantages for you and your patient: Ventilates any patient - even as your needs change to accommodate sicker patients with more complex procedures. Consumes no drive gas, allowing dramatically increased ventilation time when running on cylinders Precision volume ventilation for pediatric and other applications where accuracy is critical Pressure control ventilation is available as an option Fabius Tiro TM electronically measures and displays fresh gas flows, allowing this important information to be recorded and utilized for cost savings and quality control. uniquely tailored *The Latin word tiro (tîrõ), means Young Recruit.

... we recognize that yours are different.

Until now, you may have been faced with a choice between either a traditional stand alone anesthesia machine or an IT-ready anesthesia system. If cost and quality have been difficult to balance uncompromised

Dräger Medical gives you the best of both worlds with Fabius Tiro TM ; the anesthesia workstation that combines the ease-of-use of traditional machines with the latest technlogy. A sound business investment: Advanced ventilation technology meets your needs now and in the future Modular design easy to upgrade as your needs change and new features become available, e.g. additional ventilation modes Affordable initial cost and low lifetime costs And that s just the beginning Fabius Tiro TM is also offered as part of our CareArea TM solution, a complete workstation including our renowned Infinity Patient Monitoring System TM : Flexible vital signs monitoring Intuitive operation ESU interference suppression Solide state multigas monitoring Infinity network interface for electronic availability of all displayd datas... Fabius Tiro is your solution.

Ideal for office-based surgery flexible

Special attention was payed in the design process of Fabius Tiro TM to meet the safety and flexibility requirements of anesthesia delivery settings outside the main OR: Maneuverability allows sharing of systems among areas not constantly in use and better asset management Cylinder operation is practical for extended periods, since E-vent electronic ventilator consumes no drive gas Advanced safety features provide additional protection 45 minute battery backup with full operation Fresh gas delivery and manual ventilation possible even when electrical power is lost Self-diagnostics and leak/ compliance tests ensure system integrity Space-saving design, since real estate is at a premium Slim footprint Flexible breathing system positioning Wall-mount version provides additional convenience and space savings ideal for induction rooms... and remote anesthetizing locations in the hospital.

Technical data Weight (base unit without vaporizers or cylinders) Trolley Mount (cart) Wall Mount (with mounting bracket) Dimensions Trolley Mount (cart) Wall Mount 111 kg (245 lbs.) 48 kg (106 lbs.) 57.9 cm x 136.1 cm x 62.7 cm (W) 22.8 x (H) 53.6 x (D) 24.7 52.8 cm x 55.6 cm x 44.2 cm (W) 20.8 x (H) 21.9 x (D) 17.4 Maximum load on 12" mounting arm 8.2 kg (18 lbs. ) Power supply 100-240 VAC, 50/60 Hz., 2.3 A max. Battery (supports ventilator and monitor) 45 minutes Ventilator Electronically controlled, electrically driven. Base unit with volume control and manual/spontaneous modes. Pressure control optional. Pressure limiting (volume control) 15-70 cm H 2 O Tidal volume (volume control) 20-1400 ml Breathing frequency 4-60 bpm I:E (Inspiration/Expiration ratio) 4:1 to 1:4 Inspiratory pause (volume control) 0% - 50% PEEP (Positive end-expiratory pressure) 0-20 cmh 2 O Inspiratory pressure (pressure control) 5-65 cmh 2 O Inspiratory flow (pressure control) 10-75 L/min Integrated safety functions Sensitive Oxygen Ratio Controller (S-ORC) guarantees a minimum O 2 concentration of 23%. In case of electricity and battery failure, manual ventilation, gas delivery and agent delivery are possible. Positive pressure relief valve opens at 75 ± 5 cmh 2 O. Negative pressure relief valve opens at -7.5 to -9 H 2 O. Range of fresh gas flow indicators 0.00 to 12.0 L/min Total fresh gas flowmeter 0 to 10 L/min, calibrated with 50% O 2 and 50% N 2 O mixture O 2 flush at 55 psi (3.8 bar): max. 50 L/min; at 50 psi (3.4 bar): min. 35 L/min Vaporizer Single Dräger or Selectatec. Optional off-line vaporizer parking position. Monitoring Continuous monitoring of inspiratory O 2 concentration, breathing frequency, tidal volume, minute volume, peak airway pressure and PEEP, as well as selection of mean or plateau pressure. In addition, all fresh gas flow information is displayed as virtual flowtubes. Communication interface RS 232 Protocols Vitalink and Medibus Data available for export All fresh gas flow, ventilation and O 2 data Volume of CO 2 absorber 1.5 Liter Volume of entire compact breathing system 2.8 Liter + bag Gas supply O 2, N 2 O & Air, DISS inlet fittings Cylinder yokes O 2 & N 2 O pin index yokes (trolley); O 2 tethered yoke (wall-mount) Writing surfaces Trolley: Pull-out tray standard Wall mount: Pull-out tray optional Additional accessories Gas scavenging, patient suction Selectatec is a registered trademark of GE - Datex-Ohmeda Europe, Middle East, Africa, Latin America, Asia, Pacific: Dräger Medical AG & Co. KGaA Moislinger Allee 53 55 23542 Lübeck GERMANY Tel: +49-1805-3 72 34 37 +49-451-882-808 Fax: +49-451-882-37 79 E-mail: Business.Support@draeger.com www.draeger-medical.com Manufacturer: Dräger Medical AG & Co. KGaA 23542 Lübeck, Germany The quality management system at Dräger Medical AG & Co. KGaA is certified according to ISO 13485, ISO 9001 and Annex II of Directive 93/42/EEC (Medical devices). 90 50 015 / 08.05-4 / ls-dw / Printed in Germany / Chlorine-free - environmentally compatible / Subject to modifications / 2005 Dräger Medical AG & Co. KGaA