Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Similar documents
Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

D The plus that makes all the difference DRÄGER FABIUS PLUS

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

D The specialist for every environment DRÄGER FABIUS TIRO

D The plus that gives you more DRÄGER FABIUS PLUS

MT Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Fabius MRI. From specialists for specialists. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger Fabius GS premium Anaesthesia Workstations

Dräger Fabius Tiro Anaesthesia Workstations

Dräger Fabius plus XL Anaesthesia Workstations

A9600 Anesthesia Workstation. Your healthcare, we care.

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Anesthesia Workstation

D Your personal anesthesia assistant DRÄGER PRIMUS. Dräger. Technology for Life

Primus Anaesthesia Workstations

The centerpiece of a comprehensive anaesthesia workstation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Your patients, our primary focus. Siesta i Whispa anesthesia machine

State-of-the-art anesthesia technology

Dräger Savina Sub-Acute Care Ventilation

Aespire 7100 Essential performance Compact design

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Oxylog VE300 Emergency & Transport Ventilation

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

GE Healthcare. Aestiva/5. More than superior ventilation

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Oxylog 3000 plus Emergency & Transport Ventilation

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

The anaesthesia workstation focused on you

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

Your patients, our primary focus

DATA SHEET. VENTILATION SERVO-s

Dameca MRI 508. State-of-the-art MRI technology

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

D Reliability goes XL

S/5 Aespire. Quick Reference Guide

Safe Accurate Reliable. CWM-301 Anesthesia System

The anaesthesia workstation focused on you

Anesthesia Machine Intro

Dräger Carina Sub-Acute Care Ventilation

Siesta i Whispa Integrated technology

MT Excellent performance and reliability EVITA 4 EDITION

An intuitive and innovative answer to your anaesthesia challenges

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Hospital and Transport for Controlled Breathing

APUS Anesthesia Machines

Panther 5 Acute Care Ventilator

Technical Data and Specifications

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

D Designed for non-invasive ventilation DRÄGER CARINA

Blease900 Ventilator PATIENT CENTERED VENTILATION

Dräger Carina Sub-Acute Care Ventilation

SERVO-s v8.0 Data sheet

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

D Beyond essentials DRÄGER SAVINA 300 SELECT

Anes Machine Use and Pre-use Check - CA1 focus

MT The secret of harmonious breathing BABYLOG 8000 PLUS

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Emergency Transport and Ventilation

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Oxylog 2000 plus Emergency & Transport Ventilation

Experience the Flow. Streamlined workflow with the compact Flow-c

Multi-Gas Analyzer. Multi-Gas Analyzer bcgroupintl.com. Features - MGA MGA-3050 Multi-Gas Analyzer

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Draeger Fabius GS Pre-Use Check

Vamos / Vamos plus Anaesthetic Gas Monitors

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Supporting your patients every breath

D Rising up to the challenge OXYLOG 3000 PLUS

GE Healthcare. Avance Carestation. Upgrade promotions guide

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

Carestation 650. Physical Specifications Product Description Carestation 620 A1 ANESTESI CARESTATION 650

Hallowell EMC Anesthesia WorkStation Operating Manual

AkzentColor. Anesthesia. Anesthesia and excellent ventilation for neonatal, pediatric and adult patients

Redefining Anaesthesia DRÄGER ZEUS INFINITY EMPOWERED

Focused on essentials DRÄGER SAVINA 300

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

fabian Therapy evolution Our 2-in-1 device

Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring

Instructions for Use Fabius GS premium

Focused on essentials DRÄGER SAVINA 300

Automatic Transport Ventilator

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Anaesthesia Workstation. MODEL 7400A MODEL 7200A Glory Plus. Critical Care

INTENSIVE CARE VENTILATORS

Operation and Maintenance of the EPV200 Portable Ventilator

DATA SHEET. ANESTHESIA SYSTEM FLOW-i

Resuscitaire Neonatal Open Care

SERVO-air ventilator. Datasheet for system version 2.1

HAMILTON-MR1. Technical specifications HAMILTON-MR1

Transcription:

Fabius Tiro TM Designed for your environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Traditional hospital ORs have their needs... With more surgical procedures being performed outside of the traditional OR setting each year, Dräger Medical recognized the need to recruit a specially designed system into our CareArea TM Perioperative Care portfolio. Fabius Tiro TM * represents our commitment to meet the unique and changing needs of non-traditional locations, by making the latest technology available at a fraction of the cost: Same technology and performance as our other popular systems in a compact design Intuitive operation and layout ensures ease of use and a short learning curve Ample illuminated workspace Communication with automated record keeping systems like the Dräger Medical Innovian TM Perioperative Care for enhanced patient throughput Convenient compact breathing system (COSY): Fresh gas decoupled for tidal volume delivery unaffected by fresh gas flow adjustments Simplified design allows easy disassembly for sterilization of all components in contact with patient gas Pivot and height adjustment allow optimized positioning of breathing system Dräger Medical E-Vent piston-based ventilator is the latest in precision anesthesia ventilation technology. Electronically driven and controlled, the E-Vent provides significant advantages for you and your patient: Ventilates any patient even as your needs change to accommodate sicker patients with more complex procedures Consumes no drive gas, allowing dramatically increased ventilation time when running on cylinders Precision volume ventilation for pediatric and other applications where accuracy is critical Pressure controlled ventilation, PS and SIMV/PS are available as options Fabius Tiro TM electronically measures and displays fresh gas flows, allowing this important information to be recorded and utilized for cost savings and quality control uniquely tailored *The Latin word tiro (tîrõ), means Young Recruit.

... we recognize that yours are different.

Until now, you may have been faced with a choice between either a traditional stand-alone anesthesia machine or an IT-ready anesthesia system. If cost and quality have been difficult to balance uncompromised

Dräger Medical gives you the best of both worlds with Fabius Tiro TM the anesthesia workstation that combines the ease-of-use of traditional machines with the latest technlogy. A sound business investment: Advanced ventilation technology meets your needs today and tomorrow Modular design easy to upgrade as your needs change and new features become available, e.g. additional ventilation modes Affordable initial cost and low lifetime costs And that s just the beginning Fabius Tiro TM is also offered as part of our CareArea TM solution, a complete workstation including our leading-edge Infinity Patient Monitoring System TM : Flexible vital signs monitoring Intuitive operation ESU interference suppression Solid state multigas monitoring Infinity network interface for communication with data management systems Integrated patient gas module... Fabius Tiro is your solution.

Ideal for office-based surgery flexible

In the design process of Fabius Tiro TM, special attention was paid to meeting the mobility and flexibility requirements outside the main OR: Maneuverability allows sharing of systems among areas not constantly in use, leading to better asset management Extended operation time with cylinders, since E-vent electronic ventilator consumes no drive gas Advanced safety features provide additional protection: 45-minute battery backup with full operation Fresh gas delivery and manual ventilation are possible even during power failures Self-diagnostics and leak/ compliance tests ensure system functionality Space-saving design makes Fabius Tiro TM ideal for uses where real estate is at a premium Slim footprint Flexible breathing system positioning Wall-mount version provides additional convenience and space savings ideal for induction rooms... and remote anesthetizing locations in the hospital.

Technical data Fabius Tiro Weight (base unit without vaporizers or cylinders) Trolley Mount (cart): 245 lbs. (111 kg) Wall Mount (with mounting bracket): 106 lbs. (48kg) Dimensions Trolley Mount (cart): (W) 22.8 x (H) 53.6 x (D) 24.7 57.9 cm x 136.1 cm x 62.7 cm Wall Mount: (W) 20.8 x (H) 21.9 x (D) 17.4 52.8 cm x 55.6 cm x 44.2 cm Maximum load on 12" mounting arm 18 lbs. (8.17 kg) Power supply 100-240 VAC, 50/60 Hz., 2.3 A max. Battery (supports ventilator and monitor) up to 120 minutes, minimum 45 minutes Ventilator Event Electronically controlled, electrically driven. Operating Modes Standard: Manual / Spontaneous Volume Control (Volume) Options: Pressure Control (Pressure) Pressure Support (PS) Synchronized Volume Controlled Ventilation w/ps (SIMV/PS) Breathing frequency 4 to 60 1/min Max. Minute volume (MV) 99 L/min Positive end-expiratory pressure (PEEP) 0-20 cmh 2 O Inspiration / Expiration ratio (Ti:Te) 4 : 1 to 1 : 4 Pressure limiting (Pmax) 15-70 cmh 2 O Tidal Volume (Vt) 20-1400 ml in Volume Control 20-1100 ml in SIMV/PS Inspiratory pause (Tip:Ti) 0-50 % SIMV Inspiratory time (Tinsp) 0.3-4.0 sec Inspiratory pressure (Pinsp) PEEP + 5 to 65 cmh 2 O Inspiratory flow (InspFlow) 10-75 L/min in Volume and Pressure Control 10-85 L/min in Pressure Support Pressure Support Level ( D PPS) PEEP + 3 to 20 cmh 2 O Min. Frequency for Apnea-Ventilation (Freq. Min.) 3-20 1/min and OFF Trigger 2-15 L/min Integrated safety functions Sensitive Oxygen Ratio Controller (S-ORC) guarantees a minimum O 2 concentration of 23% in an O 2 /N 2 O mixture. N 2 O cut-off if O 2 fresh gas valve is closed or if O 2 flow is less than 0.2 L/min. Audible and visual (flashing red LED) indication in case O 2 pressure drops below 20 psi (1.38 bar) ± 4 psi (0.27 bar). In case of electricity and battery failure, manual ventilation, gas delivery and agent delivery are possible. Positive pressure relief valve opens at 75 ± 5 cmh 2 O. Negative pressure relief valve opens at -7.5 to -9 cmh 2 O Range of fresh gas flow indicators 0.00 to 12.0 L/min Total fresh gas flow meter 0 to 10 L/min, calibrated with a mixture of 50 % O 2 and 50 % N 2 O mixture O 2 flush at 87 psi (6 bar): max. 75 L/min at 41 psi (2.8 bar): min 25 L/min Vaporizer Mount Single Dräger or Selectatec. Optional off-line vaporizer parking position. Control Screen 6,5" (16,5 cm) black/amber Monitoring Continuous monitoring of inspiratory O 2 concentration breathing frequency, tidal volume, minute volume, mean or plateau pressure, peak airway pressure as well as PEEP. In addition, all fresh gas flow information is displayed as virtual flow tubes. Serial interface 1 x RS 232 (standard) 2 nd RS 232 port (option) Protocols Vitalink and Medibus Data available for export All fresh gas flow, ventilation and O 2 data Volume of CO 2 absorber 1.5 Liter, Option: Dräger Medical s prefilled CLIC absorber (1,2 l) Gas Supply O 2, N 2 O & Air Cylinder yokes O 2, N 2 O, Air, pin index yokes Additional accessories Gas scavenging, patient suction, power outlet strip, additional O 2 flow tube Volume of entire compact breathing system 1.7 Liter + bag Writing surfaces Trolley: Pull-out tray standard, flip-up side tray accessory Wall mount: Pull-out tray optional Selectatec is a registered trademark of GE - Datex-Ohmeda USA: Draeger Medical, Inc. 3135 Quarry Road Telford, PA 18969 USA Tel: +1-215-721-5400 Toll-free: +1-800-437-2437 Fax: +1-215-723-5935 E-mail: info.usa@draeger.com www.draeger.com Manufacturer: Dräger Medical AG & Co. KG 23542 Lübeck, Germany The quality management system at Dräger Medical AG & Co. KG is certified according to ISO 13485, ISO 9001 and Annex II.3 of Directive 93/42/EEC (Medical devices). 90 49 996 / 05.08-5 / ls-ed / Printed in Germany / Chlorine-free - environmentally compatible / Subject to modifications / 2008 Dräger Medical AG & Co. KG