Heavy Duty Dissolved Oxygen Meter

Similar documents
User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Dissolved Oxygen/Temp Waterproof Tester

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

BI-680 Online Dissolved Oxygen Controller Instruction Manual

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

HI 9143, HI 9143M HI 9145

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

SS32L Dissolved O 2 Probe

Optical Dissolved Oxygen Meter

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

LogIT Dissolved Oxygen Probe

Instruction Manual DO 6+ Dissolved Oxygen/Temp

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

NEULOG OXYGEN LOGGER SENSOR GUIDE

QUICK START GUIDE TO DRINKING WATER MONITORING

Optical Dissolved Oxygen Meter

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

HI 2314 HI 2315 HI 23151

Columbus Instruments

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

PRODUCT SHEET. Order probe only as RXPROBE02

EC214 EC215 - EC215R Bench Conductivity Meters

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Visit us at Code

ADT 761 Automated Pressure Calibrator

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

DISSOLVED OXYGEN SENSOR BT34i

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Pneumatic high-pressure controller Model CPC7000

D-OptoLogger Dissolved Oxygen Logger Operation Manual

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

YSI Model 52 Dissolved Oxygen Meter

12mm Dissolved Oxygen Sensor Care and Use Instructions

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

Oxygen Sensor with Electrode

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Datasheet: K-30 ASCII Sensor

Precision pressure sensor Basic version Model CPT6020

Pneumatic high-pressure controller Model CPC7000

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Instruction Manual. DO 700 Dissolved Oxygen/ºC/ºF Bench Meter. Technology Made Easy...

Using the UltraRAE. Firmware 2.35

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

SPECIFICATIONS APCEPH1

STERILIZABLE DISSOLVED OXYGEN SENSORS

CCT-7320/ROC-2313 Reverse Osmosis Controller

Membrane covered optical CO 2 sensor

PRO20 USER MANUAL. English. Français. Español. Deutsch

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

User Manual DOCUMENT # Pro20 Pro20i USER MANUAL. English

Aerobic Respiration. Evaluation copy

Owner s Manual Humiport 10/20

Micro600DO_ZI INST /1/17 13:16 Page 1. Palintest. Micro 600 DO Meter. Palintest ZI INST 1240

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

DTG - LCD Digital Temperature Gauge USER MANUAL

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

Sensoric 4-20 ma Transmitter Board Operation Manual

! Warning, refer to accompanying documents.

RADIOLOGY/ FLUOROSCOPY 15 RAD-CHECK PLUS X-RAY EXPOSURE METER

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

D-Opto Dissolved Oxygen Sensor Operation Manual

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL RLD10

MARK-302Т DISSOLVED OXYGEN METER

Additel 761 Automated Pressure Calibrators Selection Guide

Vernier Optical DO Probe (Order Code ODO-BTA)

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

Relative Humidity Calibration Kit

Model 130M Pneumatic Controller

SEALED UNIT PARTS CO., INC. PO BOX 21, 2230 LANDMARK PLACE

ISO 9001 & ISO Rev. G. Authorized Representative in the E.U.: MT Promedt Consulting GmbH Altenhofstrasse 80 D St.

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Installation Instructions

PM105 PRESSURE METER USER S MANUAL

Installation Instructions

Experiment C-6 Gas Solubility

RAM 4021-DPX Operation Manual

In Vivo Scientific, LLC INSTRUCTION MANUAL

Flashlight. Hand Lanyard. 36 Super Bright LED Bulbs. Sensor

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

GE Measurement & Control

Transcription:

User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com

Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved Oxygen or Oxygen in air, and Temperature. Units of measure are mg/l for Dissolved Oxygen, % for Oxygen in air, and o C/ o F for temperature. Oxygen is measured with a remote sensor that also contains a thermistor for measuring temperature. Advanced features include RS 232 PC serial interface, data hold, auto shut off, and Min/Max/Avg recording. Meter Description 1. LCD Display 2. POWER ON/OFF key 3. Data HOLD key 4. C/ F selection key 5. LCD Contrast Adjust 6. RECORD key 7. RECALL key 8. Factor adjust key 9. Probe head 10. Sensor body 11. Sensor plug 12. Sensor jack 13. RS-232 output jack 14. Battery cover (rear) 15. Altitude compensation key 16. O 2 Cal key 17. Zero key 18. O 2 calibration key 19. % Salt key 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407510 Product Page 2

Getting Started Note: The dissolved oxygen probe assembly may be shipped to you from the factory dry. If the probe does not contain electrolyte solution, refer to the Electrolyte Replacement section of this manual for the instructions for adding the electrolyte solution prior to initial use. Filling the Electrolyte Container Prior to Initial Use 1. Unscrew and remove the electrolyte container from the tip of the probe. 2. Fill the electrolyte container with new electrolyte. 3. Screw the electrolyte container back onto the electrode holder and probe handle. Excess Electrolyte may be forced out through the threads. Wipe clean. 4. Lightly tap the probe to remove any air bubbles. Calibration For first time use or after long periods (several days) of non-use, calibrate the instrument using the following steps. The procedure should be performed in an open, well-ventilated area. 1. Ensure that the sensor is DISCONNECTED from the meter. 2. Turn ON the meter. 3. Slide the O 2 /DO selector to the O 2 position. 4. Press the zero key to null the meter (the display should indicate "OO"). 5. Connect the DO sensor to the top of the meter (remove the plastic probe head protective cap). 6. Allow the meter to stand for at least five minutes until the display stabilizes. 7. Press the O 2 Cal key and the display will indicate approx. 20.9 (typical O 2 in air). 3

Dissolved Oxygen (DO) Measurements Measurement Preparation Before taking measurements, perform the calibration described above if necessary. In addition, perform the % SALT and ALTITUDE compensation adjustments as described below: % SALT Compensation Slide the O 2 /DO switch to the DO position. If the measured liquid is pure water or is known not to have a salt content, set the % Salt factor to 0%. 1. Press the % Salt key. The display will indicate 0% on the middle portion of the LCD display and S on the bottom portion of the LCD. 2. Pressing the Factor Adj. key once will add 1% to the salt factor. 3. Press the Factor Adj. key until the correct factor is displayed. 4. Press the % Salt key to store the factor. NOTE: 1% = 10 ppt (parts per thousand) ALTITUDE Compensation The meter has a default calibration for sea level operation (0 meters). Any significant deviation from sea level requires a compensation adjustment. Perform the following steps to do so: 1. Press the ALTITUDE key and the display will indicate a 0 in the middle of the LCD and an H on the lower portion of the LCD. 2. Press the Factor Adj. key once to add 100 meters, twice to add 200 meters, and so on. Maximum compensation is 3900 meters. 3. Once the desired compensation is displayed, press the ALTITUDE key again to store the value. Taking Measurements 1. Immerse the probe in the solution under test. For best automatic temperature compensation, immerse the probe to a depth of at least 4" (10 cm). 2. Wait until the display stabilizes. 3. The velocity of the liquid coming into contact with the probe must be at least 0.6 to 1 ft/min (0.2 to 0.3 m/s). If the solution is standing, stir the solution with the probe or use an agitator. 4. Rinse the probe with clean water after each use. Oxygen in Air (O2) Measurements Follow the same steps above for DO measurements except for the variations described below: 1. Slide the O 2 /DO switch to the O 2 position. 2. The display will indicate the oxygen air value in %. Temperature Measurements The lower display will indicate the temperature of the measured solution. Press the o C/ o F key to change the temperature units. 4

Advanced Features Data Hold Press the Data Hold key to freeze the displayed value. The LCD will display DH for Data Hold mode along with the held reading. Press the Hold key again to release the data hold function. MIN/MAX/AVG Data Recording When selected, the Data Recording function records the Min, Max, and Average readings. To start a data recording session: 1. Press the RECORD key once. The REC indicator will appear on the display and the meter will begin to record the lowest (min), highest (max), and average (avg) readings. 2. To recall the data, press the RECALL key once. The MAX indicator will appear along with the highest reading recorded since the RECORD key was pressed. 3. Press the RECALL key again to view the MIN value. 4. Press the RECALL key again to view the AVG reading. 5. To exit the Record mode, press the RECORD key again. The display indicators REC, MIN, MAX, and AVG will disappear. Auto Power OFF The meter includes an Auto shut off feature that preserves battery life. The meter will automatically turn off if no function button is pressed in any 10 minute period. To disable this feature press the RECORD key to engage the record function. LCD Contrast Adjust It may be necessary to adjust the display contrast due to a change in viewing angle or voltage drift. Use the LCD Contrast adjustment located on the right side of the meter to set the preferred contrast. CPU Reset Certain improper keystroke sequences can cause the meter to hang and become inoperable. The following procedure will reset the meter. 1. Slide the O 2 /DO switch to the O 2 position. 2. Turn the meter OFF and disconnect the DO probe. 3. Press and HOLD the O 2 CAL key and then press the POWER key. 4. Release the O 2 CAL key and then press the ZERO key. 5. Connect the DO probe. 6. Wait several minutes for the reading to stabilize and then press the O2 CAL key. RS-232 PC Interface The meter includes a RS-232 serial data port. This interface was designed to operate with the Extech Data Acquisition Software/Hardware kit Part No. 407001. This kit enables the user to capture, store and display readings using a PC. 5

Probe Head Replacement The probe head on the tip of the probe holds a thin Teflon membrane and an electrolyte container. Calibration or reading errors could indicate loss of electrolyte or a dirty/damaged membrane. The membrane is very delicate and can easily be damaged if it comes in contact with solid objects. Replacement probe heads are available from your local distributor. Replacement procedure 1. Unscrew the probe head and electrolyte container from the probe handle and discard. 2. Fill the new probe head/electrolyte container with electrolyte. 3. Screw the probe head onto the probe handle. Excess electrolyte may be forced out through the threads. Wipe clean. 4. Lightly tap the probe to remove any air bubbles. 1. Probe handle 2. Temperature sensor 3. Probe Head Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com 6

Battery Replacement The low battery indication LBT appears on the LCD when the battery runs low. To replace the battery: 1. Remove the meter's rubber protective cover to access the rear battery compartment. 2. Remove the battery compartment cover using a small coin or screwdriver and remove the 9V battery. 3. Replace the 9V battery and reinstall the cover and holster. Specifications General Specifications Circuit Display Custom one-chip LSI microprocessor circuit Dual function 0.5" (13 mm) 1999 count LCD w/ contrast adjust Measurements Dissolved O 2 : mg/l (milligrams per liter); Oxygen in air: %; Temperature: C/ F Data hold Data hold key freezes displayed reading Sensor Structure Remote Polarographic Dissolved Oxygen Sensor Temperature sensor: Precision thermistor Data recording Min/Max/Avg readings stored for later recall Auto power off Meter turns off after 10 minutes Sample rate 0.4 Sec (approx.) Data Output RS 232 PC serial interface Operating conditions Temperature: 32 to 122 F (0 to 50 C); Humidity: < 80% RH Battery power 9V alkaline battery Power Consumption Approx. 6.6 ma DC Weight Dimensions Accessories Optional accessories 0.74 lbs. / 335 g (including batteries & probe) Main instrument: 7.1 x 2.8 x1.3" (180 x 72 x 32mm) Probe: 4.9" x 0.8" length/diameter (125 x 20mm) Carrying case, 9V battery, and 5 membranes Membranes, data acquisition software & RS232 interface cable Electrical Specifications Measurement Range Resolution Accuracy Dissolved Oxygen 0.0-19.9 mg/l 0.1mg/L + 0.4 mg/l Oxygen in air 0-100% O 2 0.1 % O 2 + 0.7% O 2 Temperature (probe only) Compensation adjustments 32 to 122 o F 0 to 50 o C 0.1 o F/C ±1.5 o F + 0.8 o C Temperature (automatic) 32 to 122 o F (0 to 50 o C) Salt 0 to 39% (1% = ppt) Altitude 0 to 3900 meters 7