Guided Wave Radar in Solid Level Applications

Similar documents
Specify the Right Remote Diaphragm Seal Solution for Vacuum Applications

485 Annubar Primary Flow Element Installation Effects

Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor

How to specify a product. Process Sensors and Mechanical Instruments

Ultrasonic level transmitter and indicator

Instrumentation & Data Acquisition Systems

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor

Radar, Ultrasonic and RF Level Transmitters

Rosemount Process Radar in Power Applications

GRAVITY FLOW DILUTE PHASE PNEUMATIC CONVEYING DENSE PHASE PNEUMATIC CONVEYING ORIFICE GATE. Handles powders, granules and pellets

Level MEASUREMENT 1/2016

High-performance submersible pressure transmitter For level measurement Model LH-10

BAPI Pressure Line of Products - FAQs

Structural Design of Tank Weighing Systems

TDR-2000 Two-Wire Guided Wave Radar Installation & Operation Manual

9700 Transmitter Submersible hydrostatic level transmitter

Rosemount 1195 Integral Orifice Primary Element

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Tripod Series OPERATOR S MANUAL

Installation and Operation Manual

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Vacutrans Instructions

Troxler Electronic Laboratories, Inc.

Electro-Pneumatic Converter YT-940 SERIES

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

Residential Meters. Available innov8 Outputs 900 MHz Radio Virtual Network 3W Standard AMR 2W AMR 2W Standard Touchpad Scalable Pulse 4-20mA SCADA

T EK-SUB 4800C 19 mm Submersible Level Transmitter

The cable clamp is a cheap accessory highly recommended to prevent the cable from being damaged.

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

High-performance submersible pressure transmitter For level measurement Model LH-10

The Original Dome Valve Range

Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal

Roller Chain and Sprocket Troubleshooting Guide

Pneumatic blending in a bin or silo that is, aerating. Saving time, labor, and money with pneumatic batch blending

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

Pneumatic blending in a bin or silo that is, aerating. Saving time, labor, and money with pneumatic batch blending. Copyright CSC Publishing

SPWE Series. Setup Instructions. Version 2.0

Model 1159 Remote Diaphragm Seals Manual

Vessel Weighing. Load Cells and Weigh Modules VPG TRANSDUCERS. Technical Note VPGT-06. Scope. Accuracy. Mode of Operation. Mechanical Considerations

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

PHOENIX, ARIZONA USA

Material Handling Hose

256 Pneumatic Pressure Indicator

Gas Pressure Regulator HON 200

DX2/DXX Operating Instructions

TDR Guided Wave Radar

SOLO TRIPOD SERIES Operator s Manual

EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

Precision Liquid Settlement Array Manual

BULK SOLIDS HANDLING Valve Solutions Unlock the Potential

Drag Conveyors DRAG CONVEYORS

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Point Level Measurement. Switching Technology for Liquid and Solid Level Measurement

DTG - LCD Digital Temperature Gauge USER MANUAL

MODEL WEIGH MODULE

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

SDX Submersible Depth Transmitter User Manual

Vessel Weighing. Load Cells VPG TRANSDUCERS. Application Note VPG-06 TECH NOTE. Scope. Accuracy. Mode of Operation. Mechanical Considerations

BUILD-UP & BLOCKAGE CLEARING SYSTEM for silos, bins, hoppers, & most storage vessels

Casing Spacer Technology Leaders

INTERLOCKED METAL HOSE

Autocalibration Systems for In Situ Oxygen Analyzers

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Aquavar SOLO 2 Frequently Asked Questions

Osborne Engineering Limited. OEJ Equalised thrust bearing internals

Electro Controls. Level WattsIndustries.co.uk

Airwalker. Installation and Safety Information. Stretch Products for Dance, Therapy, Education, and Fitness

The Discussion of this exercise covers the following points:

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

Cold-acclimatised pipelines

BaseCal 3, calculating the performance of Diaphragm Seals

3.0 Pressure Transmitter Selection

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

LVU2800 Series. Ultrasonic Level Transmitter

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Rosemount 1195 Integral Orifice Assembly. Quick Start Guide , Rev EA June 2016

Encore PE 50-lb Feed Hopper

Rosemount Integral Orifice Flow Meter Series. Reference Manual , Rev KA December 2017

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

1.0 Fill fluids. Rosemount DP Level Fill Fluid Specifications April Technical Note , Rev EA

Improving distillation tower operation

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

GRAVEL/ FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

STARLOG. Capacitive Water Depth Probe

Laboratory Mortar Mixer (Testing)

A-100, AD, CD, CD2M and PD Membrane level indicator for solids. Operating Instructions. Safety instructions Operating instructions

REVISIONS. App Thom. App Sud. App PC IG 2014/09/19

Limerock Bearing Ratio Technician Training Course

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

Transcription:

Technical Note Rosemount 5300 Series Guided Wave Radar in Solid Level Applications KEY POINTS Measuring Range Probe End Projection function (PEP) Tensile Strength and Collapse Load Mounting Considerations Electrostatic Discharges and Electromagnetic Interference OVERVIEW Guided Wave Radar is a very reliable method for measuring solids, such as powders, granulates, or pellets with a grain size of up to 0.8 in. (20 mm). Materials include plastics, fly-ash, cement, sand, sugar, cereals, grains, and many others. With the Rosemount 5303, measurements can be made even on fine powders in dusty environments and in silos where the media surface is not flat and where free-propagation radar transmitters may be unsuitable. MEASURING RANGE For a Rosemount 5303 with a flexible single lead probe, the maximum probe length is 164 ft. (50 m). Table 1 shows the maximum measuring range depending upon the dielectric constant of the product. The Rosemount 5303 Probe End Projection (PEP) function may improve the maximum measuring range. TABLE 1. Maximum measuring range Dielectric Constant Maximum Measuring Range w/o PEP Rosemount 5303 with flexible single lead probe Maximum Measuring Range w. PEP 1.4 49 ft. (15 m) 138 ft. (42 m) + air gap (1) 1.8 82 ft. (25 m) 122 ft. (37 m) + air gap (1) 2.0 115 ft. (35 m) 116 ft. (35 m) + air gap (1) 3 138 ft. (42 m) 94 ft. (28 m) + air gap (1) 4 151 ft. (46 m) 82 ft. (25 m) + air gap (1) 6 164 ft. (50 m) Not Needed (1) The air gap is the distance to the material surface. Note, however, that the maximum measuring range cannot exceed the probe length i.e. 164 ft. (50 m). See the Probe End Projection function section for more information. Table 2 shows typical dielectric constants for several solids. The measurement is made where the probe comes in contact with the material, which means that the shape of the material surface is not critical for the measurement. Measurements are also independent of moisture, material fluctuations such as density and temperature. The maximum practical measuring range also depends on the tensile load in your application. See Tensile Strength and Collapse Load section for more information. www.rosemount.com

Rosemount 5300 Series Technical Note TABLE 2. Dielectric Constants of Typical Bulk Solids Dielectric Constants (1) Typical Bulk Solids 1.1-1.9 Plastic powder, granulate White lime, special cement Dry sawdust Sugar granulate Cement, plain 1.9-2.5 Fly ash Burnt Lime Coal dust, dry Portland cement Plaster 2.5-4.0 Starch Grain, seeds Ground stones Carbon black Sand 4.0-7.0 Naturally moist (ground) Stones, ores Salt Cement powder > 7.0 Carbon black Coal dust, moist Brown coal Metallic powders Calcium Carbonate Rosemount 5303 Maximum Measuring Range See Table 1 See Table 1 See Table 1 See Table 1 164 ft. (50 m) (1) Dielectric values can differ depending on particle size and the amount of air or moisture in the material. More air will lower the dielectric value while more moisture will increase it. These tables provide a rough guideline. PROBE END PROJECTION FUNCTION Probe End Projection (PEP) is a function in the 5303 transmitter that allows for measurements when the surface pulse is too weak to be detected. This commonly occurs when the material dielectric is very low, especially in combination with a long distance to the surface, or electromagnetic interference. The method is based on the fact that microwaves propagate slower through product than through air. By using the product dielectric constant and the probe end echo, the surface position is calculated when the surface echo is unavailable. The PEP function will only be activated as a backup if the surface echo is too weak. Reference pulse No pulse from the surface For dielectric constants <1.4, the surface pulse may be too weak to be detected and measurements cannot be made unless the Probe End Projection function is used. For longer measuring ranges, non-contacting radar may be a better choice. See Technical Note Measuring Solids with a Rosemount 5600 Non-Contacting Radar (Document Number 00840-0100-4024). Probe end pulse The PEP function is recommended for solids with a dielectric constant less than or equal to 2. The maximum measuring range with PEP is 164 ft. (50 m) (maximum probe length) divided by the square root (sqrt) of the material dielectric constant (DC) + the air gap to the material surface. If the DC is 2 and the vessel is filled, the maximum measuring range is 115 ft. (35 m) (e.g. 164 ft. (50 m) / sqrt(2)). For a lower DC or with an air gap in the top of a vessel, it is possible to measure longer distances (see Table 1 on page 1 for details). 2

Technical Note Rosemount 5300 Series Measurement Output Surface Threshold Surface Pulse Over threshold meaning directly measured Reference Pulse Probe End Pulse Would be positive if anchored (a) Echo Curve Showing Surface Directly Measured Measurement Output PEP calculates the surface by using probe end and product dielectric constant Surface Threshold Surface Pulse Too Weak To Be Detected Reference Pulse Probe End Pulse Would be positive if anchored (b) Echo Curve Showing Surface Detected By PEP 3

Rosemount 5300 Series Technical Note The PEP is easily configured by using the guided setup in either Rosemount Radar Master, AMS, or the Field communicator. For best performance, complete the guided setup with an empty vessel to accurately calibrate probe end offset and probe end pulse polarity, and then a second time with material in the vessel to get a surface echo to calculate the product dielectric constant. For detailed information on configuring PEP, see the Rosemount 5300 Series Reference Manual (Document Number 00809-0100-4530) Accuracy is highly dependent on a correctly configured DC value, and may be affected when using PEP. The longer the measuring range, the higher the error (e.g. sqrt(dc error)*measure range). It is therefore recommended to only use PEP when required and allow the transmitter to go into direct measuring mode. Obtaining the real surface echo will allow automatic correction of the DC. Do not set the surface echo threshold too high in areas where it is possible to reliably detect the real surface. Instead, allow the surface to sometimes be within the maximum measuring range without PEP (see Table 1). However, even if the accuracy may be affected, the repeatability will not be affected. If PEP is used to measure in an application with EMI, the accuracy may be affected. For example, if the surface echo is too weak to distinguish from the noise and the surface threshold is raised to only use the probe end pulse, accuracy will be affected if the DC is not configured correctly. Fixing the end of the probe to a surface (e.g. silo wall) affects the PEP accuracy. First, due to the slack of the probe needed to reduce the risk of probe breakage, the measurement is slightly non-linear. Secondly, if the fixing is not sufficient, the probe end pulse is not consistent. It is recommended to use the probe rope itself for anchoring (e.g. slot through a welded eye and then fasten with a chuck) rather than using a ring attached to the weight. 4

Technical Note Rosemount 5300 Series TENSILE STRENGTH AND COLLAPSE LOAD The flexible single lead probe is recommended for solids. It is available in two versions to handle different loads and lengths: 0.16 in. (4 mm) diameter; Minimum tensile strength is 2698 lb. (12kN); Maximum collapse load is 3597 lb. (16 kn) 0.24 in (6 mm) diameter; Minimum tensile strength is 6519 lb. (29 kn); Maximum collapse load is 7868 lb. (35 kn) Tensile strength is the amount of force the probe can withstand before any deformation occurs. The definition for collapse load is the maximum amount of force needed to break the probe. The collapse load value should be less than what the roof can withstand. If the collapse load is reached, the probe will break before enough force is exerted on the roof to cause collapse. If the probe breaks, the process seal remains intact. It is important to keep the following in mind when planning for installation: TABLE 3. Tensile Load Values (1) Tensile load for 0.16 in (4 mm) flexible single lead probe, lb (kn) In solid applications, media may cause pull down forces on silo roofs. The silo roof must be able to withstand the probe collapse load, or at least the maximum probe tensile load In solid applications, there might be considerable tensile load caused by the media. The tensile load of the media should not exceed the tensile strength of the probe. The tensile load depends on the silo size, material density, and the friction coefficient. Forces increase with the buried length, the silo and probe diameter. In critical cases, such as products with a risk of build-up, it is better to use a 0.24 in. (6 mm) probe Forces on probes, depending on their position, are generally two to ten times greater on probes that are anchored to the vessel. The probe end should not be fixed for 100 ft. (30 m) or longer probes Table 3 shows guidelines for the tensile load from free-flowing solids acting on a suspended probe, free-hanging, not anchored to the vessel, in a silo with smooth metallic walls. A safety factor of 2 is included for the calculations. Consult the factory if more information is needed. Tensile load for 0.24 in (6 mm) flexible single lead probe, lb (kn) Material Probe length 49 ft. (15 m) Probe length 115 ft. (35 m) Probe length 49 ft. (15 m) Probe length 115 ft. (35 m) 10 ft. (3 m) 39 ft. (12 m) 10 ft. (3 m) 39ft. (12 m) Wheat 670 (3) 1120 (5) 1800 (8) 4500 (20) 10 ft. (3 m) 39 ft. (12 m) 10 ft. (3 m) 39 ft. (12 m) 900 (4) 1690 (7.5) 2810 (12.5) 6740 (30) Plastic pellets 340 (1.5) 670 (3) 810 (3.6) 2360 (10.5) 450 (2) 920 (4.1) 1190 (5.3) 3510 (15.6) Fly ash 770 (3.4) 1690 (7.5) 1980 (8.8) 5980 (26.6) Coal dust 540 (2.4) 1190 (5.3) 1390 (6.2) 4230 (18.8) Cement 900 (4) 2020 (9) 2470 (11) 7310 (32.5) Ground limestone 830 (3.7) 1820 (8.1) 2230 (9.9) 6650 (29.6) (1) A safety factor of 2 is included for the figures. 1130 (5) 2520 (11.2) 2950 (13.1) 8990 (40) 790 (3.5) 1780 (7.9) 2070 (9.2) 6320 (28.1) 1350 (6) 2920 (13) 3600 (16) 10790 (48) 1260 (5.6) 2740 (12.2) 3330 (14.8) 9960 (44.3) 5

Rosemount 5300 Series Technical Note MOUNTING CONSIDERATIONS Mount the probe as far away as possible from filling and emptying ports. This will minimize load and wear and will help to avoid disturbances from the incoming product For environments where electrostatic discharges are likely to occur, e.g. plastics, it is recommended that the probe end is grounded with a proper grounding connection (R<1 Ohm) In case of non metallic tanks, a Rosemount 5303 should be mounted with a metal plate of minimum 8 in. (200 mm) diameter. Use metal shielding for the conduit connections Recommended mounting position Installing the probe at about 1 /3 to 1 /2 of the silo radius is recommended to compensate for measurement errors caused by centered filling of the material cone The minimum recommended probe distance to tank wall or disturbing object is 20 in. (50 cm), unless the wall is comprised of smooth metal, then the distance is 4 in. (10 cm). In any case, the probe should not be able to touch the wall of the tank during operation The maximum recommended nozzle height is nozzle diameter + 4 in. (100 mm) When nozzles are more than 4 in. (100 mm) in height, a Long Stud (LS option) is recommended to prevent the probe from contacting the nozzle Installation with metal sheet in non-metallic vessels In the case of bunkers with a concrete roof, a Rosemount 5303 should be installed flush with the inner roof surface or in a nozzle insert Installation in concrete silo with metal shielding < D + 4 in. (100 mm) To prevent an extremely high tensile load when fixing the probe, and to reduce the risk of probe breakage, the probe must be slack. Select a probe longer than the required measuring range so that there is a sag in the middle of the probe that is greater than or equal to 1 1 /2 in. per 10 feet (1 cm per m) of the probe length Long Stud (9.8 in./250 mm) Nozzle Height Nozzle Diameter Probe installation should occur when the silo is empty, and the probe should be regularly inspected for damage Avoid 10-in. (250 mm) / DN250 or larger diameter nozzles, especially in applications with low dielectric constant Fixing probe with slack For applications with a probe length longer than 115 ft. (35 m), please consult factory Consider using a non-contacting radar for abrasive media that can wear out the probe 6

Technical Note Rosemount 5300 Series ELECTROSTATIC DISCHARGES AND ELECTROMAGNETIC INTERFERENCE In some applications, such as plastic pellets, electrostatic charges can build up and eventually discharge. While the Rosemount 5303 electronics can tolerate some static charge, providing a good earth ground for the electronics and attaching the end of the probe to the vessel will create ground paths for discharge away form the electronics. When the product can build up static electricity, the probe should be properly grounded (R<1 Ohm). For further information grounding see Technical Note Best Practices for Grounding and Transient Protection on Rosemount Radar Transmitters (Document Number 00840-2700-4811). Grounding the probe end in products building up static electricity The Rosemount 5303 uses a patented smart Electromagnetic Interference (EMI) filter, which filters out most common EMI from rotating equipment, motor controllers, and other sources. With severe EMI, the sensitivity may be reduced. Probe End Projection offers additional measurement reliability (see Probe End Projection function on page 2). In a metal silo there is no issue with EMI from rotating equipment, motor controllers, and other sources. To avoid issues with EMI in non-metallic silos, the transmitter s threshold settings should be checked and Probe End Projection should be activated. Forces on probes, depending on their position, are generally two to ten times greater on probes that are anchored to the vessel. 7

Rosemount 5300 Series Technical Note The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. Asset Management Solutions is a trademark of Emerson Process Management. HART is a registered trademark of the HART Communication Foundation. All other marks are the property of their respective owners. Standard Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_sale 2010 Rosemount Inc. All rights reserved. Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 949 7001 Emerson Process Management Blegistrasse 23 P.O. Box 1046 CH 6341 Baar Switzerland Tel +41 (0) 41 768 6111 Fax +41 (0) 41 768 6300 Emerson FZE P.O. Box 17033 Jebel Ali Free Zone Dubai UAE Tel +971 4 811 8100 Fax +971 4 886 5465 Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 Tel +65 6777 8211 Fax +65 6777 0947 Service Support Hotline : +65 6770 8711 Email : Enquiries@AP.EmersonProcess.com 00840-2300-4811 Rev EA, 04/10