Installation, Operation & Maintenance Manual

Similar documents
Installation, Operation and Maintenance Manual

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

2 Sentry MCL Installation, Operation & Maintenance

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual

2 Sentry MVS Installation, Operation & Maintenance

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Installation, Operation & Maintenance Manual

OPERATING AND MAINTENANCE MANUAL

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Index Table. Model 794. Installation, Operating and Maintenance Instructions

1 DRIVE INDUSTRIAL IMPACT WRENCH

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Yoke Block Instruction Manual

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Yoke Block Instruction Manual

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

D05 Pressure Regulating Valves

AIR/OVER HYDRAULIC JACK 20 TON

DelVal Flow Controls Private limited

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

PP-1, PP-1W, PP-2, & PP-3

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

TITAN FLOW CONTROL, INC.

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

WEATHERIZING INSTRUCTIONS

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

600 o F High Temperature Aging Cell Instruction Manual

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Installation, Operation & Maintenance Manual

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

3/8" Dr. Air Butterfly Impact Wrench

GILMONT ACCUCAL FLOWMETERS

FLANGED MULTI-PORT BALL VALVES

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Installation, Operation, and Maintenance Manual

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Booster Pump PB4-60 Replacement Kits

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

Atmospheric relief valve type 1100 Installation and maintenance instructions

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Agilent 1290 Infinity Pump Head Maintenance

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Installation, Operation, and Maintenance Manual

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

ACCESSORY KIT INSTALLATION INSTRUCTIONS

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

InstallatIon and owner s InstrUCtIons

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Constant Pressure Crude Oil Container Model CPCCP

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

600 / 600FC OWNER'S MANUAL

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

INSTRUCTIONS FOR FM4460N SERIES HIGH PRESSURE, METAL TUBE FLOWMETERS

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Duo/Trio Office Bike Owner s Manual

35 TON HYDRAULIC PUNCH WARNING

Model ASSEMBLY and OPERATING INSTRUCTIONS

Installation, operation & maintenance manual - original version

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

User Instruction Manual

Float Operated Level Controllers

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

ALTERNATOR RACKS 135, 170 & 190 INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 3000 Units

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HP-104 & HP-106 Tapping Machine OPERATIONS MANUAL

TECHNICAL DATA. Page 1 of 12

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Transcription:

Original Instructions Installation, Operation & Maintenance Manual Sentry VREL Control Valve Pressure Conditioning S-SW-IOM-00277-15 1-17

Table of Contents Safety Information... 3 General Safety Precautions... 4 Overview.... 5 Installation................................. 5 Operation.... 7 Replacement Parts... 8 Standard Warranty.... 10 Customer Support.... 11 Copyright Do not install, maintain, or operate this equipment without reading, understanding, and following the appropriate Sentry Equipment Corp instructions. Otherwise, injury, damage, or both may result. 2016 by Sentry Equipment Corp. All rights reserved. All product and company names are property of their respective owners. This document contains proprietary information. No part of this document may be photocopied or reproduced without the prior written consent of Sentry Equipment Corp. Limit of Liability Sentry Equipment Corp, its employees, agents, and the authors and contributors to this document specifically disclaim all liabilities and warranties, express or implied (including warranties of merchantability and fitness for a particular purpose), for the accuracy, currency, completeness, and/or reliability of the information contained herein and/or for the fitness for any particular use and/or for the performance of any material and/or equipment selected in whole or part with the user of/or in reliance upon information contained herein. Selection of materials and/or equipment is at the sole risk of the user of this publication. Note The information contained in this document is subject to change without notice. 2 Sentry Equipment Corp

Safety Information Please read the entire manual before attempting to unpack, set up, or operate this product. Pay careful attention to all Warnings, Cautions, and Notes. Failure to do so could result in serious personal injury and/or equipment damage. Use of Hazard Information If multiple hazards exist, the signal word corresponding to the greatest hazard shall be used. Definitions DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address practices not related to personal injury. Â NOTE Information that requires special emphasis. Â TIP Alternate techniques or clarifying information. SHALL: This word is understood to be mandatory. SHOULD: This word is understood to be advisory. Sentry VREL Control Valve 3

General Safety Precautions Product Selection, Installation, and Use Improper selection, installation, or use can cause personal injury or property damage. It is solely the responsibility of users, through their own analysis and testing, to select products suitable for their specific application requirements, ensure they are properly maintained, and limit their use to their intended purpose. Follow proper local, state, and federal regulations for proper installation and operational requirements. Always use caution and common sense when working with any chemical. Read the product label and Material Safety Data Sheets (MSDS) carefully and follow the instructions exactly. Potential Equipment Hazards Hot surfaces! This equipment may have very hot surfaces. If an operator contacts a hot surface, injury may occur. Use protective clothing to prevent injury. If other equipment comes in contact with a hot surface, damage to the equipment may occur. Ensure the area around this equipment is kept clear to prevent this damage from occurring. High pressures! This equipment may contain fluids at very high pressures. Prior to installing, removing, or maintaining this equipment, ensure that the equipment is isolated from all connecting piping, the equipment is depressurized, the contents have been drained, and the equipment is cool. 4 Sentry Equipment Corp

Overview The Sentry VREL Control Valve is a valve specifically designed for high-pressure liquid sampling. Typical applications are for the pressure reduction and flow control of samples greater than 500 psig (34.5 bar). The adjustable rod-in-tube design allows for variable pressure drop and flow control of high-pressure liquid samples. The VREL valve is also cleanable in place. The VREL valve is an adjustable rod-in-tube pressure reducing device. The pressure of the incoming sample is reduced as the liquid is forced to travel through the narrow gap between the tapered rod and the rod opening. Because the reduction in pressure is done over the entire length of the rod, localized wear is held to a minimum. The result is a very long service life compared with devices in which the pressure drop is taken over a very short distance (fixed orifice, pressure regulator, etc.). Other devices erode frequently causing friction loss and down time. With a VREL valve, the flow or pressure drop can be changed while the sample is flowing by adjusting the position of the rods. Turning the handle moves the rods in or out on the lead screw. If sample flow is blocked, the rods can be fully retracted to allow sample pressure to flush the dirt through. The sample line never needs to be shut off or the VREL valve disassembled to accomplish this. This is very important as the operator tries to get critical samples while boiler pressure is rising or falling during startup or shutdown. Installation To ensure the protection provided by this equipment is not impaired, this equipment must not be installed or used in any manner other than that which is specified in this manual. Ensure that the VREL valve is installed such that it will not be subject to steam or water sample temperatures greater than 300 F. Damage to the VREL valve or downstream equipment may occur. The physical dimensions of the VREL valve are shown on the drawing in Figure 4. The VREL valve can be mounted in any position. The cutouts for panel mounting are shown in Figure 4. The locating pin ensures correct orientation to connecting tubing. As an alternative, a U-bolt can be used to hold the body to a panel face or post. Sentry VREL Control Valve 5

Installing the VREL valve in a Panel Isolate the sample line and make sure that it cannot be opened during installation of the VREL valve. Failure to isolate the sample line could expose personnel to high pressure and/or hot materials. 1. Drill holes in panel per Panel Cutout diagram in Figure 4. 2. Remove valve handle assembly by unscrewing head nut and pulling assembly out of body. 3. Remove panel lock nut. 4. Insert body assembly from rear of panel using locating pin to position body. ÂÂ NOTE Do not rely on the locating pin to hold the barrel assembly while tightening the head nut. 5. Install panel locknut. Pull up snug. 6. Insert rods into barrel. Be sure keyway on rod assembly lines up with key inside barrel. Tighten head nut finger tight. 7. From the backside of the panel, use a wrench on the body nut to hold the body while further tightening the head nut. It may require considerable torque to get a tight seal on the metal-to-metal sealing surface inside the head nut. 8. The head nut must be fully tightened before the packing nut can be tightened or loosened. Tighten packing nut with 15-20 ft-lb (20.3-27.1 Nm) of torque. Connecting Sample Tubing Isolate the sample line and make sure that it cannot be opened during installation of the VREL valve. Failure to isolate the sample line could expose personnel to high pressure and/or hot materials. Three types of tube end configurations are available: Type 1: Plain end 1/4" tubes with no connections for use with customer supplied compression fittings. Type 2: Socket weld socket weld fittings for customer s 1/4", 3/8" or 1/2" tubing. Type 3: 37 Fitting - 37 metal to metal fitting for customer s 1/4" or 3/8" tubing. 6 Sentry Equipment Corp

A VREL valve with Type 1 or Type 3 connectors can be easily disassembled. Type 2 connectors must be cut out. For Type 2 and Type 3 connections, the customer must weld the system tubes either to the socket weld fittings (Type 2), or to the loose weld adapter (Type 3). In the case of Type 3 connections, be sure to slide the nut onto the tube before welding the adapter. See Figure 1. Figure 1. Connection Type 3 37 Fittings CUSTOMER TUBE WELD ADAPTER CUSTOMER TUBE CUSTOMER WELD Operation NUT During operation, the VREL valve may become hot. Do not touch. Use care not to touch adjacent hot sample lines. When starting up a sample line that includes a VREL valve, always be sure that the rods are fully inserted before opening the sample isolation valve (turn handle clockwise to insert rods). The VREL valve is not a positive shut-off device. Even when fully closed, approximately 150 cc/ min sample flow through the VREL valve is possible. When the rods are fully inserted, the yoke bottoms in the barrel. When the rods are fully retracted, the yoke is stopped by the seal. Do not try to turn the handle by using extra force. The threads will be damaged. After opening the isolation valve fully, adjust the setting of the VREL valve until the desired flow is established. Turning the handle clockwise will decrease flow; turning counterclockwise will increase flow. Clean in place Isolate the sample flow before cleaning the VREL valve. When performing this cleaning operation, the sample pressure is not being reduced by the VREL valve. Failure to isolate the sample flow could result in serious injury and/or cause damage to pressure-sensitive equipment downstream from the VREL valve. Since corrosion products, scale, and other foreign matter may be present in sample lines, plugging of the VREL valve is possible. To clean, fully retract the rods by turning the handle in a counter-clockwise direction. Allow the obstruction to clear. Readjust the setting of the VREL valve until desired flow is established. Sentry VREL Control Valve 7

Service Before servicing, ensure that the sample line is isolated and cannot be opened during this service. This is necessary to prevent exposure to high pressure and/or hot materials. Allow the VREL valve to cool to a comfortable touch prior to commencing service. No normal maintenance is required. Replacement parts available are listed below. Replacement Parts Part Number Item 6-02302C VREL Valve Seal Kit (Figure 2) (includes thrust washer, spring seal & backup washer) 6-02302E Valve Handle & Rod Assembly (Figure 3) includes both 6-02302A and 6-02303A 6-02302A Valve Handle Assembly Only (Figure 3) 6-02303A Tapered Rod & Nut Assembly Only (Figure 3) 6-04605A VREL Swivel Handle Figure 2. 6-02302C VREL Seal Kit Thrust Washer Spring Seal & Backup Bushing Ratings Wetted materials: 316 Stainless Steel Weight: 4 lbs Pressure: 5000 psig at 300 F (345 barg at 149 C) 8 Sentry Equipment Corp

Figure 3. 6-02302E Valve Handle & Rod Assembly 6-02303A Rod & Nut 6-02302A Valve Handle Assembly Figure 4. VREL Plain End Alignment Pin Body Nut 1/4" max panel thk Panel Lock Nut 12 7/16" Removal Clearance Required 4" [102mm] REF. 14 1/8" [359mm] REF. 19 9/16" [497mm] REF. 37 Fitting Socket Weld 4 5/16" 5 5/16" Panel Cutout Ø 5/16" 15/16" Ø 1 1/4" Sentry VREL Control Valve 9

Standard Warranty Sentry Equipment Corp ( Seller ) warrants products manufactured by it and supplied hereunder ( Products ) to be free from defects in workmanship and, to the extent materials are selected by Seller, to be free from defects in materials, in each case for a period as defined in the table below: Brand Product Line Warranty Period Sentry Steam & Water Sampling Products and Systems Solid & Powder Sampling Products and Systems Gas Sampling Products and Systems Liquid & Slurry Sampling Products and Systems Pipeline Integrity Products Eighteen months from date of shipment or twelve months from startup (whichever occurs first) Waters Equipment Steam & Water Sampling Products and Systems Twelve months from date of shipment To view the full warranty, go to www.sentry-equip.com/warranty. 10 Sentry Equipment Corp

Customer Support With proven sampling expertise since 1924, Sentry products and services provide business operations the critical insights to optimize process control and product quality. We deliver true representative sampling and analysis techniques to customers around the globe, empowering them to accurately monitor and measure processes for improved production efficiency, output, and safety. Standing behind our commitments, we are determined to tackle any application, anywhere. We know that running an efficient operation isn t easy. It requires thorough, careful analysis of controlled, real-time data achieved through reliable, accurate, and repeatable process monitoring and measuring. By effectively conditioning, sampling, and measuring gas, liquid, slurry, powder, solids, steam, or water within their production environments, our customers obtain the critical insights they need to control and optimize their processes. Yet, controlling your processes also means reliable customer support throughout the life cycle of your equipment. Customer Service General information, warranty claims, order management. Installation Service For systems that require specialized expertise upon installation. Technical Support Troubleshooting, training, and technical manuals. Field Service & Retrofits When a problem needs immediate attention. Replacements Parts & Consumables Order your replacement parts and consumables. Sentry ProShield Services Select from four ProShield Guardian service plans providing different levels of support to protect your large system investments with regularly scheduled maintenance. To learn more, go to www.sentry-equip.com/support. Sentry VREL Control Valve 11

Serving customers in more than 50 countries across six continents worldwide. sentry-equip.com 966 Blue Ribbon Circle North, Oconomowoc, WI 53066 U.S.A. +1-262-567-7256 support@sentry-equip.com