* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

Similar documents
MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

MODERN APPROACH FOR CONDITION MONITORING OF POWER TRANSFORMERS USING DISSOLVED GAS ANALYSIS

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

HumiSys HF High Flow RH Generator

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Since the beginning of production of oil for transformers

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Quadruple mass spectrometers (transducer type)

Dissolved Gas Analysis An Early Identification of Faults in High Voltage Power Equipment using MATLAB GUI

A Revised Framework for the Transformer DGA Guide

Understanding Dissolved Gas Analysis (DGA) Techniques and Interpretations

Comparison of Different DGA (Dissolved Gas Analysis) Methods for the Condition Assessment of Power Transformers

Dissolved Gas Analysis - Past, Present and Future

Portable Gas Analyzers

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS

Used with Dissolution Tester for Fraction and Flow Measurements

Online DGA-monitoring of power transformers

The New PHD 4 Portable Helium Detector

Mass Flow Controller (MFC) for Gases

Columbus Instruments

AUTOMATIC VAPOR PRESSURE TESTER REID METHOD, DEMI SIZE MODEL AVP-30 INSTRUCTION MANUAL. Rev

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

TRANSFORMER SERVICE. Dissolved gas analysis and oil condition testing

Mass Flow Meter (MFM) for Gases

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

FTC130 Transmitter. Operating Manual

Mass Flowmeters. Mass Flowmeters for Gases

Best Practice Guide, Servomex 2700

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

TM8 On-Line Gas Chromatography DGA Monitor Site Preparation Guide Model TMx Series

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

A REVIEW OF DISSOLVED GAS ANALYSIS AND TRANSFORMER HEALTH CONDITION

Manual of SF6 Comprehensive Tester

Operating Instructions Part No

MODEL CALIBRATION GAS DELIVERY SYSTEM

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

PHOENIX L300i Best-in-class Helium Leak Detectors

Code Basic module and level control complete with optionals code

Applied Technology and Best Practices in CEE. Conference

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

UNDERSTANDING, ACCELERATED

Blood Parameter Monitoring System 550

UT 3000 Mercury Ultratracer

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Discovery HP-TGA 75/750. Site Preparation Guide

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

EI-5 Ethane Identifier. User Manual

OXYBABY - MOBILE HAND HELD GAS ANALYSER

PGA3510 Portable 3-Gas IR Analyzer. Operations Manual

IRwin Methane Leak Detector. Innovation makes the difference

Nandkumar Wagh, D.M. Deshpande

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

O NEof Premium tools for professionals!

TM8 On-Line Gas Chromatography DGA Monitor Operation & Maintenance Guide Model TMx Series

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Mass Flow Controller (MFC) for Gases

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Draft Guide for the Interpretation of Gases in Oil Immersed Transformers

Dr. Tetsuzo KITAGAWA, Tokihiko YONEDA, Shigefumi NAKAJIMA. 1. Preface

Gas-Detection Instruments

Automated Determination of Dissolved Gases in Water Anne Jurek

Specifications of Oxygen Sensor Module V-8344A

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

Improved Monitoring of Dissolved Transformer Gases on the Basis of a Natural Internal Standard (NIS)

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Online Publication Date: 19 January, 2012 Publisher: Asian Economic and Social Society

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

System Overview. TCD Detector temperature setpoint Regulator

Features. Description

DISSOLVED GAS ANALYSIS OF POWER TRANSFORMERS

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

EXPERIMENT 12 GAS LAWS ( BOYLE S AND GAY-LUSSAC S LAW)

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Dräger X-dock Frequently Asked Questions

DAKSHIN TRANSFORMER OIL MULTI STAGE GAS EXTRACTOR

VACCUPERM Vacuum chlorine gas dosing systems

analytical bulk flow distance FLOW level pressure temperature industrial communication

The instrument will process the samples one by one till all the samples have been cleaned up.

780S Ultra High Purity Series

FAS-W. Features. Applications. Automatic condensation hygrometer

Pensky-Martens Closed Cup Automatic Flash Point Tester Model APM-7 with Data Memory Instruction Manual Rev

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Optical Dissolved Oxygen Meter

We measure it. For gas and water installers. testo hpa. bar

Bubble Point / Pressure Decay Test / Gas Transport Rates through Membranes

Operating Instructions Part No

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

Visualize Nitrogen Gas Consumption

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

Transcription:

Portable DGA Dissolved Gas Analyzer <Model : PGA-300> MITSUBISHI Portable Dissolved Gas Analyzer (PGA-300) is used to analyze 6 kinds of dissolved gases in transformer oil, thereby improving prompt action of maintenance and reducing maintenance cost. Operation of this apparatus is easily done after setting the sample oil which is sampled from transformer. A whole operation sequence of this apparatus is controlled by a microprocessor. It has the advantage of being handy to carry. Features * Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2 H 2 that is Key Gas in Transformer Abnormality * Quick Measurement ( 15 minutes ) * Small amount of oil sample (50 cc) * Compact and Light (12 kg) * Equipped with Communication Interface SDK-M8789(1/2)

Configuration Column 4Sensors Sample loop Stirring magnet Sample vessel Heater Sample oil Magnetic stirrer AP Flow controller CPU board Filter AP LCD touch panel Printer Personal Computer Specifications C O N T E N T S C 2 H2 ( A c e t y l e n e ) 0. 5-5 0 0 C 2 H4 ( E t h y l e n e ) 1 0-2, 0 0 0 C O ( C a r b o n M o n o x i d e ) O b j e c t i v e G a s a n d H2 ( H y d r o g e n ) M e a s u r e m e n t R a n g e ( p p m ) C H4 ( M e t h a n e ) 2 0 2, 0 0 0 C 2 H6 ( E t h a n e ) T C G 5 0 1 0, 0 0 0 M e a s u r e m e n t A c c u r a c y ( % ) ± 2 0 M e a s u r e m e n t T i m e ( m i n ) 15 E x t r a c t i o n M e t h o d O i l S t i r r i n g U p a n d C i r c u l a t i n g A i r a b o v e O i l C a r r i e r G a s Air D i m m e n s i o n ( m m ) W 4 5 0 D 2 0 0 H 3 5 5 a n d M a s s 12kg P o w e r S u p p l y 1 0 0-1 2 0 o r 2 0 0-2 4 0 V A C ( 5 0 / 6 0 H z ) 200VA m a x. S i n g l e - p h a s e W o r k i n g E n v i r o m e n t ( d e g r e e C ) 0-4 5 C o m m u n i c a t i o n I / F O n e R S 2 3 2 C p o r t f o r p r i n t e r O n e U S B p o r t f o r p e s o n a l c o m p u t e r MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE: Mitsubishi Denki Building 2-2-3, Marunouchi, Chiyoda-ku, Tokyo 100-8310, Japan http://global. mitsubishielectric. c o m / TRANSMISSION & DISTRIBUTION SYSTEMS CENTER: 651 T e n w a, Ako-city, Hyogo 678-0256, JAPAN Phone +81-791-46-2144 FAX +81-791-46-2387 SDK-M8789(2/2)

Portable DGA (Dissolved Gas Analyzer) Model PGA-300 TECHNICAL SHEET - 1-

1. Outline and Introduction The portable in-oil gas analyzer is a primary diagnosis equipment which is used to prevent serious troubles and designed to detect internal abnormal phenomena of transformer early by measuring the concentration of gases CO, H 2, CH 4, C 2 H 2, C 2 H 4, C 2 H 6.and the total concentration of combustible gases (TCG). After sample oil taken from transformer is set in the oil vessel, a sequence of operations, namely extraction of dissolved gas from the oil, detection of gas, and quantitative determination of gas, is executed automatically. The result of measurement is obtained as analysis data after about 15 minutes. The PGA-300 has the following advantages. (1) Measuring of TCG and 6 component gases The analyzer has the gas detecting ability which is necessary for the detection and diagnosis of incipient transformer abnormality. This analyzer equipped with a special separating column to separate component gases and 4 kinds of sensors having different gas detection characteristics is capable of measuring the total combustible gas concentration (TCG) and the concentration of gases CO, H 2, CH 4, C 2 H 2, C 2 H 4, and C 2 H 6. (2) High sensitivity of the C 2 H 2 (Acetylene) The analyzer can detect very low concentration of C 2 H 2 (Acetylene) even though it s concentration is 0.5ppm in transformer oil. C 2 H 2 (Acetylene) is the key gas for detection of transformer abnormality since it is the characteristic gas produced in occurrence of partial discharge and high temperature local heating in oil immersed transformer. (3) Sampling oil amount is small. The quantity of oil to be taken for analysis is as small as 50 ml. (4) Quick measurement is ensured. Since the result of measurement can be obtained about 15 minutes after start of measurement, quick diagnosis is ensured. (5) Equipped with sophisticated man-machine interface The operator-operation panel interaction system ensures easy measurement. The result of measurement is indicated on the LCD. (6) Compact size and light for carry The analyzer is so compact and light that it can be easily carried to the measuring site. (7) Database can be made on the personal computer by using the attached Data Management Program which performs data communication via USB serial port, data acquisition and diagnosis. - 2-

2. Specifications Table 2.1 shows the specifications of the PGA-300. Table 2.1 Specifications of PGA-300 General Extraction section Detection section Control section Size Mass Item Power supply Range of operating temperature W450 D200 H355 (mm) Approx. 12 kg Description AC 100-120 or 200-240V (50/60Hz) 200VA single-phase 0 C - 45 C Gas extraction method Equilibrium extraction with oil stirring and circulating air above oil Quantity of sample oil 50 ml Gases to be detected (Objective gases) Detection concentration Separating column Detecting sensor Measurement accuracy Measurement time Carrier gas PWB Composition Control/ data processing MMI/F Communication I/F Data acquisition Carbon monoxide (CO), hydrogen (H 2 ), methane (CH 4 ), acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ) and TCG TCG : 50 10,000 ppm C 2 H 2 : 0.5 500 ppm C 2 H 4 : 10 2,000 ppm H 2, CO,CH 4,C 2 H 6 : 20 2,000 ppm Special chromatographic column 4 kinds of Semiconductor with Platinum filament sensor (Hot wire semiconductor sensor) ±20% Within the range of C 2 H 2,: 20 to 500 ppm Within the range of CO, H 2, CH 4, C 2 H 4, and C 2 H 6 : 20 to 1,000 ppm 15 minutes (for the first measurement after power is turned on, the waiting time of 30 minutes is required) Atmospheric Air CPU,DI/O PWB x1pc A/I PWB x 1PC 32-bit CPU for control/data processing LCD touch panel Printer (Option) :Graphic thermal printer One RS-232C port for printer and one USB port for personal computer 100 analysis results - 3-

3. Configuration Fig 3.1 shows the piping diagram of Portable DGA. And Fig 3.2 shows the appearance of this apparatus. C o l u m n 4Sensors Sample loop Stirring magnet Sample vessel Heater Sample oil Magnetic stirrer AP Flow controller CPU board Filter AP LCD touch panel Printer Personal Computer Fig.3.1 Block diagram Fig 3.2 Appearance of PGA-300-4-

4. Standard Accessories and Recommended Spare parts Details of standard accessories and spare parts, recommended spare parts, optional parts and maintenance tools are shown in Tables 4.1, 4.2, 4.3 and 4.4 respectively. Table4.1 Standard accessories and spare parts No. Nomenclature Description Quantity 1 Data Management Program For Windows based Personal Computer (Personal Computer is not included.) 1 piece 2 Serial communication cable USB cable 1 piece 3 Oil trap filter For inline of tubing 1 piece 4 Inlet oil filter For gas inlet of gas extraction probe 1 piece 5 O-ring For gas extraction probe 1 piece 6 Sample oil vessel For gas extraction 1 piece Table 4.2 Recommended spare parts No. Nomenclature Description 1 Air filer For carrier air filer 2 Oil trap filter For inline of tubing 3 Inlet oil filter For gas inlet of gas extraction probe 4 O-ring For gas extraction probe 5 Sample oil vessel For gas extraction Table 4.3 Optional parts No. Nomenclature Description 1 Printer Graphic thermal printer with serial communication cable 2 Printer paper For printer Table 4.4 Recommended maintenance tools No. Nomenclature Description Gas cylinder contained gases mentioned bellow O 2 : 21% +/-10% C 2 H 2 : 50ppm +/-20% 1 Standard gas mixture CO: 300ppm +/-20% C 2 H 4 : 300ppm +/-20% H 2 : 200ppm +/-20% C 2 H 6 : 300ppm +/-20% CH 4 : 200ppm +/-20% N 2 : Main component 2 Pressure regulator For cylinder of standard gas mixture Necessary for adjusting output pressure of 10kpa - 5-