Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Similar documents
Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Steam Trap BK BK 212-ASME. Original Installation Instructions English

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

UNA 45 UNA 46 UNA 46A

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

GESTRA Steam Systems AK 45. Installation Instructions Condensate Drain Valve AK 45

Inverted Bucket Steam Trap IB 16A-7

Steam Trap MK 25/2 MK 25/2S

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

SCA Series Inverted Bucket Steam Traps

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

756 Safety Relief Valves

AK 45. Installation Instructions Condensate Drain Valve AK 45. A Siebe Group Product 1

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

GESTRA Steam Systems BK 45 BK 45U BK 46. English. Installation Instructions Steam Traps BK 45, BK 45U, BK 46

Non-Return Valve SRK 22A

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

Pressure Reducing Valve for Steam Type 2333 A

Swing Check Valve CB 14 CB 24S CB 26 CB 26A

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

776 Cryogenic Safety Valve

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Pressure reducing valves Index

TSS21 Sealed Thermostatic Steam Tracer Trap

CLASS TLP Pressure Reducing Valve

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Regulating valves REG-SA and REG-SB

Production capacity.

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

CA44, CA44S, CA46 and CA46S Air and Gas Traps

S and SF Inverted Bucket Steam Traps

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

TP1 and TP2 Temporary Cone Shaped Strainers

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

PRESSURE REDUCING VALVE RP45 (EN)

CA10S, CA14 and CA14S Air and Gas Traps

ARI-SAFE-SN ANSI Safety valve ANSI - safety valve Semi Nozzle (ANSI )

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

KTM 50 (DN ) Installation, maintenance and operating instructions

L21S/SR/ST Glass Level Gauges

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

PV4 and PV6 Piston Valves

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

Hand operated regulating valves Types REG-SA and REG-SB

CA44 and CA44S Carbon Steel Air and Gas Traps Flanged DN15 to DN25

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Instruction presentation Special valves

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Pressure Reducing Valve DMV 750 set range: bar

Pilot Operated Pressure Reducing Valve

Self-operated Pressure Regulators for special applications

Liquid level regulating valves Types PMFL / PMFH and SV

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Pressure Reducing Valve DMV 755

Materials : Carbon steel ASTM A216 WCB

Types S100K and S102K Pressure Regulators

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL M2

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

GESTRA. GESTRA Steam Systems CB 1... CB 2... Installation Instructions Swing Flap Non-Return Valves CB 1..., CB 2...

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Pressure and Flow Control Valves DBGM, German and European Patents

6301 TYPE CAST IRON SAFETY VALVES

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

DCV6 Disc Check Valve

Transcription:

Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with optional extras/accessories Description Steam traps type UNA 43 and UNA 46 are designed for draining condensate from steam systems. Steam traps type UNA 43 can also be used for removing condensate from compressed air systems. Steam traps type UNA 46 can also be used for removing condensate from gases or gas mixtures. The equipment must only be used within the allowable pressure and temperature limits and only if the chemical and corrosive influences on the equipment are taken into account. Function The control unit opens the orifice as a function of the liquid level. A rising level results in a proportional opening of the equipment. The max. discharge capacity depends on the orifice size when the ball is completely lifted off its seat and the orifice is fully open. Optional extras Float-lifting lever allows the float to be manually lifted (for purging any dirt away from the seat area) Hand-vent valve allows manual air-venting the pipeline Accessories Magnetically operated liquid level gauge Insulation NRG 16-19 or NRG 16-27 End connections UNA 43: Flange EN 1092-2 B PN 16 Flange ASME B 16.1 Class 125 FF Flange JIS B 2239 10K UNA 46: Flange EN 1092-1 B1 PN 40 Flange ASME B 16.5 Class 150 RF Flange ASME B 16.5 Class 300 RF Flange JIS B 2220 10K Flange JIS B 2220 20K Flange KS available on request The different equipment versions allow you to adjust the flow direction of the equipment to the flow pattern of your installation. The flow arrow must correspond to the direction of the fluid flow. The following positions of installation are possible: v Design "v" for installation in vertical line with downward flow hl Design "hl" for installation in horizontal line with flow direction left hr Design "hr" for installation in horizontal line with flow direction right Materials Component part Type EN ASTM Body UNA 43 5.1301 A126-B UNA 46 1.0619 SA216-WCB Cover UNA 43 5.1301 A126-B UNA 46 1.0619 SA216-WCB Body gasket, control unit gasket, adapter gasket all Graphite CrNi Membrane regulator capsule all Hastelloy / stainless steel Sealing plugs, stud bolts, nuts, manual float-lifting lever all Forged steel, heat resistant Other components all Stainless steel 1

Design 1 2 3 4 5 6 Item no. Designation 1 Hexagon nuts 2 Body 3 Body gasket 4 Control unit DUPE 5 Stud bolts 6 Cover 7 Drain with sealing plug 8 Name plate 10 9 8 9 Adapter 7 10 Direction of flow arrow Optional extras The following items are available as optional extra: 12 13 11 14 Item no. Designation 11 Control unit SIMPE 12 Hand-vent valve with socket spanner (socket spanner not shown) The connection in the cover for the manual vent valve can also be used for fitting a balance pipe. 13 Sealing plug 14 Electrodes NRG 16-19 or NRG 16-27 15 Manual float-lifting lever In equipment with control unit SIMPE the manual vent valve is included as standard. 13 14 13 15 Dimensions and weights The drawing shows equipment with flanged ends for downward flow. Space required for servicing H2 H B H2 H1 H H1 2 1 2 1 To remove the cover a withdrawal space S of 240 mm (9.4 in) is required. If the supplied socket spanner or the lever extension is attached to the equipment an additional clearance of 150 mm (5.9 in). is required. S B Direction of flow horizontal 2

Dimensions and weights DN 80 (3") Abbreviation End connection [mm] ["] B all 471 18.5 H1 all 150 5.9 H2 all 273 10.7 H all 423 16.7 1 all 250 9.8 2 all 325 12.8 Flange to EN 450 17.7 Flange to ASME, JIS 457 18.0 all 13 0.5 Weights [kg] [lb] Weight EN PN16/40, ASME C 125/150, JIS 10K, JIS 20K 111 244.7 UNA 46 ASME C 300 114 251.3 DN 100 (4") Abbreviation End connection [mm] ["] B all 471 18.5 H1 all 150 5.9 H2 all 273 10.7 H all 423 16.7 1 all 250 9.8 2 all 325 12.8 Flange to EN 450 17.7 Flange to ASME, JIS 457 18.0 all 13 0.5 Weights [kg] [lb] Weight DN 150 (6") EN PN16/40, ASME C 125/150, JIS 10K, JIS 20K 117 257.9 UNA 46 ASME C 300 125 275.6 Abbreviation End connection [mm] ["] B all 503 19.8 H1 all 150 5.9 H2 all 150 10.7 H all 423 16.7 1 all 250 9.8 2 all 325 12.8 Flange to EN 500 19.7 Flange to ASME, JIS 502 19.75 all 13 0.5 Weights [kg] [lb] Weight UNA 43 EN PN 16, ASME C 125, JIS 10K UNA 46 EN PN 40, ASME C 150, JIS 10K, JIS 20K 132 291.0 138 304.2 UNA 46 ASME C 300 150 330.7 3

Pressure and temperature ratings imiting conditions for UNA 43: Flange EN PN 16 Pressure 1 ) p [barg] 16.0 14.4 12.8 12.3 11.2 9.6 Temperature 1 ) T [ C] -10/120 150 200 230 250 300 Max. admissible differential pressure PM [barg] 2, 4, 8, 13 1 ) Pressure and temperature: imit values for body/cover to EN 1092-2 imiting conditions for UNA 43: Flange ASME C 125 Pressure 1 ) p [barg] 13.8 13.3 12.7 10.2 9.6 8.6 Temperature 1 ) T [ C] -29/65 80 100 180 200 232 Max. admissible differential pressure PM [barg] 2, 4, 8, 13 [psi] 29, 58, 116, 188 Pressure 1 ) p [psig] 200 190 180 145 130 125 Temperature 1 ) T [ F] -20/150 200 225 375 425 450 1 ) Pressure and temperature: imit values for body/cover to ASME B16.1 imiting conditions for UNA 43: Flange JIS 10K Pressure 1 ) p [barg] 14.0 14.0 10.0 Temperature 1 ) T [ C] -10/20 120 220 Max. admissible differential pressure PM [barg] 2, 4, 8, 13 1 ) Pressure and temperature: imit values for body/cover to JIS B2239 imiting conditions for UNA 46: Flange EN PN 40 Pressure 1 ) p [barg] 40.0 37.1 33.3 27.6 25.7 13.1 Temperature 1 ) T [ C] -10/20 100 200 300 350 450 Max. admissible differential pressure PM [barg] 2, 4, 8, 13, 22, 32 1 ) Pressure and temperature: imit values for body/cover to EN 1092-1 imiting conditions for UNA 46: Flange ASME C 150 Pressure 1 ) p [barg] 19.6 17.7 13.8 10.2 8.4 5.5 Temperature 1 ) T [ C] -29/38 100 200 300 350 425 Max. admissible differential pressure PM [barg] 2, 4, 8, 13, 22 [psi] 29, 58, 116, 188, 320 Pressure 1 ) p [psig] 285 260 200 140 125 80 Temperature 1 ) T [ F] -20/100 200 400 600 650 800 1 ) Pressure and temperature: imit values for body/cover to ASME B16.5 imiting conditions for UNA 46: Flange ASME C 300 Pressure 1 ) p [barg] 51.1 46.6 43.8 39.8 37.6 28.8 Temperature 1 ) T [ C] -29/38 100 200 300 350 425 Max. admissible differential pressure PM [barg] 2, 4, 8, 13, 22, 32, 40 [psi] 29, 58, 116, 188, 320, 465, 580 Pressure 1 ) p [psig] 740 680 635 570 550 410 Temperature 1 ) T [ F] -20/100 200 400 600 650 800 1 ) Pressure and temperature: imit values for body/cover to ASME B16.5 imiting conditions for UNA 46: Flange JIS 10K Pressure 1 ) p [barg] 14 14 12 10 Temperature 1 ) T [ C] -10/20 120 220 300 Max. admissible differential pressure PM [barg] 2, 4, 8, 13 1 ) Pressure and temperature: imit values for body/cover to JIS B2220 imiting conditions for UNA 46: Flange JIS 20K Pressure 1 ) p [barg] 34 31 29 26 23 20 Temperature 1 ) T [ C] -10/120 220 300 350 400 425 Max. admissible differential pressure PM [barg] 2, 4, 8, 13, 22, 32 1 ) Pressure and temperature: imit values for body/cover to JIS B2220 4

Capacity Chart The chart shows the maximum capacities for hot condensate for the respective orifice. The capacities are dependent on the differential pressure (working pressure). The differential pressure is the difference between inlet and outlet pressure and depends among other things on the run of the condensate line. If the condensate downstream of the trap is lifted, the differential pressure is reduced by approximately 1 bar for 7 m lift. The maximum admissible differential pressure is dependent on the cross-sectional area of the orifice and the density of the liquid. These curves indicate the max. capacities of hot condensate that the steam traps UNA 43 and UNA 46 can discharge with virtually no banking up. Cold water capacity: Capacity multiplied by factor F. Capacity Chart [lb/h] [kg/h] 100000 200000 60000 100000 40000 80000 30000 60000 20000 40000 30000 10000 6000 10000 4000 8000 3000 6000 DN 80-150 - AO 2 DN 80-150 - AO 4 DN 80-150 - AO 8 DN 80-150 - AO 13 DN 80-150 - AO 22 DN 80-150 - AO 32 DN 80-150 - AO 40 Capacity 4000 3000 2000 2000 1000 0,1 0,2 0,5 1 2 4 8 13 22 32 40 [bar] 1,5 2 3 4 6 8 10 20 30 40 60 80100 200 300 [psi] 465 580 Differential pressure Factor F = 1.11 1.15 1.17 1.19 1.21 1.22 1.24 1.26 1.27 The max. differential pressure Δ PM of the equipment depends on the type of orifice (O) used. Orifice ΔPM [bar] Diameter of bore [mm] 2 2 32.0 4 4 25.8 8 8 19.8 13 13 16.6 22 22 18.5 32 32 15.9 40 40 14.5 5

Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/ JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" Spare Parts 3 17 19 21 4 20 22 12 Inspection and Certification Documentation regarding material tests and in-house examination with test report EN10204 available. All inspection requirements have to be stated with the enquiry or order. After supply of the equipment certification cannot be established. Charges and extent of the above mentioned test certificates as well as the different tests confirmed therein are listed in our Price ist "Test and Inspection Charges for Standard Equipment". For other tests and inspections than those listed above, please consult us. Application of European Directives Pressure Equipment Directive (PED) The equipment conforms to this directive and can be used for the following media: UNA 43 Fluids of group 2 UNA 46 Fluids of group 1 Fluids of group 2 ATE Directive The equipment does not have its own potential ignition source and is not subject to this directive. When installed, static electricity may arise between the equipment and the connected system. When used in potentially explosive atmospheres, the plant manufacturer or plant operator is responsible for discharging or preventing possible static charge. If it is possible for medium to escape, e.g. through actuating mechanisms or leaks in threaded joints, the plant manufacturer or plant operator must take this into consideration when dividing the area into zones. 24 Item no. Designation Orifice Stock code # DUPE SIMPE 2 560720 560727 4 560721 560728 Control unit including orifice, cpl. 8 560722 560729 3, 4/11, 17, with body gasket, adapter gasket and 19, 20 gasket for control unit, socket-head 13 560723 560730 cap screws 22 560724 560731 32 560725 560732 40 560726 560733 3, 17, 19, 22, 23 Gasket set 1 ) all 560750 12, 22 Hand-vent valve, cpl. with joint ring and socket spanner all 560676 15, 16, 23 Manual float lifting lever, cpl. with gasket and lever extension all 560749 3, 21 Membrane regulator capsule 5N2, cpl. with body gasket all 560748 2 560734 560741 4 560735 560742 8 560736 560743 24 Orifice 13 560737 560744 22 560738 560745 32 560739 560746 40 560740 560747 Socket spanner for hand vent valve all 560700 11 15 23 16 1 ) Contains: 4 gaskets 3 /8" 1 gasket 3 /4" 1 body gasket 1 gasket for control unit 1 adapter gasket Supply in accordance with our general terms of business. GESTRA AG Münchener Straße 77, 28215 Bremen, Germany Telefon +49 421 3503-0, Telefax +49 421 3503-393 E-mail info@de.gestra.com, Web www.gestra.de 819584-00/01-17cm (808961-00) GESTRA AG Bremen Printed in Germany 6