Quantitative Analysis of Hydrocarbons by Gas Chromatography

Similar documents
5890II GC Standard Operating Procedure 9/2/2005

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

System Overview. TCD Detector temperature setpoint Regulator

Experiment GC : Analysis of BTEX by GC-FID

AKTA pure 25 New Owner s Intro

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

SOP: Buck Scientific BLC-20P HPLC Operation

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Simplified Backflush Using Agilent 6890 GC Post Run Command Application Note

The Gas Laws: Boyle's Law and Charles Law

GCMSD-Headspace Analysis SOP

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

FROG-4000 TM Chemical Analysis System

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

FROG-4000 TM Chemical Analysis System

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Rapid and Reliable Detection of Dissolved Gases in Water

Boyle s Law VC 09. Experiment 9: Gas Laws. Abstract

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

Gas Absorption Column CAG

Operation of the Perkin Elmer TGA-GC/MS

FROG-5000TM Chemical Analysis System User s Manual

AKTA 3D SOP. Click on the System Control tab. This screen has 4 windows.

In addition to reading this assignment, also read Appendices A and B.

This GC has two columns (I think new columns can be ordered from Restek)

SHIMADZU LC-10/20 PUMP

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

no peaks missing peaks too small peaks increasing retention decreasing retention

Varian 3300 Gas Chromatograph Abbreviated Operating Instructions

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Armfield Distillation Column Operation Guidelines

AKTA MC SOP Page 1 9/27/04 AKTA METAL CHELATING SOP

SOP for use of the SX19 Stopped-Flow Instrument

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

Name Student Activity

Pipetting and Determining Protein Concentration

Manual for continuous distillation

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

Using the Akta Prime plus October 22, 2012

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Physics Experiment 17 Ideal Gas Law Qualitative Study

SOLUBILITY OF A SOLID IN WATER

IMPACT OF THE HELIUM SHORTAGE ON PROCESS GAS CHROMATOGRAPHS

Gas Laws. Introduction

Boyle s Law: Pressure-Volume Relationship in Gases

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

Aerobic Respiration. Evaluation copy

SOLUBILITY OF A SOLID IN WATER

Buck Scientific, Inc.

Boyle s Law: Pressure-Volume Relationship in Gases

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Multiple Gas#5 GC configuration Jan 2016

Boyle s Law: Pressure-Volume. Relationship in Gases

Chromatographic separation procedures: gas chromatography with Cobra4

Exp. 5 Ideal gas law. Introduction

Retention Time Locking: Concepts and Applications. Application

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

Appendix: Simplified Instructions for Operating the HP 5890 GC/FID and Air Sampling Systems

Experiment 18 Properties of Gases

Vapor Pressure of Liquids

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

Evaluation copy. Vapor Pressure of Liquids. computer OBJECTIVES MATERIALS

Vapor Pressure of Liquids

Carrier Gases in Capillary GC

Lab 1. Adiabatic and reversible compression of a gas

Hydrostatics Physics Lab XI

Standard Operational Procedure for Capillary Electrophoresis

ISO INTERNATIONAL STANDARD

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Ideal gas law. Introduction

EXPERIMENT 12 BEHAVIOR OF GASES

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

TROUBLESHOOTING. Dwell Volume Revisited. Gradient transfer does not have to be problematic.

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

Generating Calibration Gas Standards

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

11.1 Dumas Method - Pre-Lab Questions

The instrument will process the samples one by one till all the samples have been cleaned up.

Gas Diluter Portable Gas Dilution System User s Manual

PRESSURE-TEMPERATURE RELATIONSHIP IN GASES

Calibration of a GC955

Carrier Gases in Capillary GC

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

SOP: Cation Exchange Chromatography of t-pa using AKTA Pure system

FIG: 27.1 Tool String

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Applied Technology and Best Practices in CEE. Conference

1. Determining Solution Concentration

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Experiment. THE RELATIONSHIP BETWEEN VOLUME AND TEMPERATURE, i.e.,charles Law. By Dale A. Hammond, PhD, Brigham Young University Hawaii

Intermolecular Forces

Transcription:

Quantitative Analysis of Hydrocarbons by Gas Chromatography Introduction Gas-liquid chromatography (GLC) accomplishes a separation by partitioning solutes between a mobile gas phase and a stationary liquid held on a solid support. A sample is injected into a column. The solutes are absorbed at the column inlet by the stationary phase and then desorbed by fresh carrier gas. This sorption-desorption process occurs repeatedly as the sample is moved through the column toward the outlet by the carrier gas (mobile phase). Each solute will move at its own characteristic rate, and the individual bands separate to a degree that is determined by the relative strengths of the sorption-desorption partitioning. Non-sorption phenomena such as eddy and molecular diffusion tend to broaden the individual solute bands and reduce separation efficiency, and a main task of chromatographers is always minimizing peak broadening. Signals from a detector located at the column outlet appear as a plot of detector response (counts) vs. time. The time at which a peak appears is characteristic for the component making up the peak; the peak area, and usually peak height as well, are proportional to the concentration of the component. GLC is limited to volatile compounds that can be vaporized below about 400 C without decomposing. About 15% of all organic compounds fall within this classification; a much smaller number of inorganic compounds have the appropriate physical properties for GLC analysis. In this exercise you will measure some properties of a GLC system and use it for both identification and determination of some hydrocarbons in a mixture. Procedure Samples Obtain a set of samples and a syringe from your TA. You should have small bottles containing pentane, an equal volume mixture of pentane, hexane, heptane and octane, and an unknown. Instrument Familiarization The gas chromatograph uses a packed column of polydimethyl siloxane and a thermal conductivity detector with helium as the mobile phase. A simple soap-bubble flowmeter attached to the column outlet allows measurement of the gas flow rate. A computer using a software package called PeakSimple operates the gas chromatograph that will be used in this lab. This software not only controls the GC but also can be used to treat data. 1

The detector can be destroyed if it is turned on without an adequate flow of helium through the system. Your Teaching Assistant will turn on the system and adjust the gas flow. The carrier gas pressure and the detector operating conditions will have been set to appropriate values. Do not adjust these. Note the controls and indicators on the front panel of the chromatograph. LEDs on the status panel show when a component is active or being thermostatically controlled. Locate the LEDs for the thermal conductivity detector (TCD) and the column. The display selector switch toggles between constant display of the column oven temperature (down position) and display of parameters selected by the push buttons below the LEDs on the status panel. The selected quantity is displayed on the three digit LED display. Using the Chromatograph: 1. Put the switch in the up position and note the temperature of the TCD. 2. If the PeakSimple program for your chromatograph is not already running, start it in the usual fashion by double clicking on the appropriate icon (GC1, GC2, GC3 or GC4). 3. When the program completes its initialization, right-click in the chromatogram display zone. 4. Choose Temperature on the menu that appears. 5. Highlight the existing temperature program and click on the Change button. For the initial measurements you will want to run at a constant temperature of 60 C. 6. Set the program for 60 C for 20 minutes then ramp at 0 C/minute to 60 C. 2

7. Exit the menu. 8. Note that the column temperature changes. After the column temperature stabilizes record the column temperature and the TCD temperature. 9. Use a stopwatch and the soap bubble flowmeter 1 to measure and record the flow rate (ml/min) of the mobile phase. 10. By gently squeezing the rubber bulb raise the level of the soap above the side arm so that a soap bubble rises up the pipet column. 11. Use a stop watch to record the time required for the bubble to sweep through a measured volume and calculate the flow rate. Note: If the pipet is dry when you start the bubbles may collapse before they reach the top. You may need to start several bubbles to wet the column. You can refill the bulb by adding soap to the top of the pipet. Injecting Samples When using direct injection, as we will here, the technique used to prepare the syringe and perform the injection can affect the quality of the separation and the reproducibility of the results. Take care not to bend the needle when inserting it into the injection port. Syringes are expensive! Develop a consistent technique of injection using the following steps. 1. Prime the syringe. Draw in sample. Eject the sample outside the vial. Wipe the needle. Repeat several times. 2. Draw one microliter of air into the syringe. 3. Draw one microliter of sample into the syringe after the slug of air. 4. Draw another microliter of air into the syringe, sandwiching the sample between the slugs of air as shown below. Wipe the needle. 1 In this lab we use a homemade flowmeter made of an overturned graduated cylinder and a water bath. Your TA will demonstrate how to use it. 3

5. Smoothly and quickly insert the needle its full depth into the injection port, press the plunger, withdraw the needle, and tap the space bar on the computer keyboard to start the data collection. Measurements 1. Tap the space bar to start data acquisition. 2. Click on the Z button to zero the display. You can adjust the position of the zero line on the display by clicking and dragging it. 3. Terminate the run by tapping the End key. Display limits can be adjusted by clicking the + and - buttons. You should start with a range of about 100 mv. You can also set the default limits for the display through the Edit menu. 4. Click Edit/Channels/Details and enter numbers for the maximum and minimum default display limits. Isothermal measurements 1. Set the chromatograph for isothermal measurements at a column temperature of 60º C. 2. Inject 1 µl of pentane. The pentane peak should appear in about 2 minutes. Once the pentane peak has returned to the baseline you can terminate the run. By adjusting the scaling (clicking on the + button) you should also be able to see a weak air peak that occurs a little before the pentane peak. 3. Right click on the pentane peak. A menu will appear. Select add component. A retention time and range bar will appear. Right click on the peak again and select edit component. Enter the name of the component (pentane) in the appropriate space. 4. Click on the Results tab. Record the retention time and peak area. Close the window. 5. Repeat injecting and recording pentane chromatograms until you have five sequential measurements with a range of less than 0.1 minutes in the retention time. The peak areas should have a range of about 20% of the peak area. 6. Determine retention times for air and the normal hydrocarbons (pentane, hexane, heptane, octane) using 1 µl injections of the four-component mixture. Run and record values at least three times. Save these chromatograms as both binary (CHR) and Ascii (ASC) files, with the names nnn4isox, where nnn is your initials and x is a run number. Are all the peaks resolved? Air is a non-retained component. You need to know the time at which it appears to be able to calculate adjusted retention times for the sample components. If you have trouble seeing the air peak try injecting only air (up to 5 µl) and running a chromatogram. You do not need to save any air-only chromatograms, but record the air retention times. To enable the software to detect the air peak and display its retention 4

time you may need to adjust the integration parameters. Click on Edit/Channels/Integration and set Area reject to a small value (1 or 2). Temperature programmed measurements 1. Set the chromatogram to run at 50º C for 1 min and then to ramp up at 20º per minute for 6 minutes. (Right click in display space and select Temperature. ) 2. Since you have changed the conditions the component markers are no longer relevant. To clear them select Edit/Channels/Components/Clear. 3. Record a chromatogram for your four-component mixture. Label the components. Are all the peaks resolved? Record the retention times and peak areas for the components. Save CHR and ASC files. Label them with the name nnn4pgmx. 4. Record and save CHR and ASC chromatograms for your unknown. Label them nnnunkx. Record the areas for all the components. Lab Report Read the ASC files of one of your isothermal chromatograms and one of your temperature-programmed chromatograms of the four-component mixture into Excel. Prepare a graph plotting the two chromatograms on the same time axis, detector response in A.U. (arbitrary units) versus time in minutes. You will need to generate data for the x- axis. The data points are acquired at intervals of 1 second. For each peak in your isothermal chromatogram calculate the retention factor, k, and the number of theoretical plates,,. Calculate from: = 5.55 t R 2 /(W 1/2 ) 2. You can find W 1/2 by looking at the data in your spreadsheet to find the points at which the signal drops to half the maximum value for each peak. If your peaks are sitting on a pedestal (that is, the baseline value is not zero), you need to remove the pedestal before finding the peak maximum and the half-maximum points. Tabulate your isothermal results in a table organized as shown in the lab report template. Put in a caption for the table that includes the temperature, flow rate, and the identity of the chromatograph (GC1, GC2, ) you used. Calculate and report the resolution for the pentane/hexane pair of peaks for the isothermal and temperature-programmed chromatograms. Resolution is defined as the ratio of the peak separation divided by the average base at half width of the two peaks. To get the base half width, find the width of the peak at the half-maximum point and multiply by 2. 5

Following is the resolution expressed by formula: = / /, where t r represents the component s retention time and W 1/2 that component s half width at full maximum. Prepare a graph (using Excel) of log t R versus carbon number (as abscissa). Have the equation of the linear regression line and the R2 value appear on the graph. Prepare a separate graph showing the chromatogram of your unknown. Tabulate your quantitative analysis results in a table organized as shown in the lab report template. Be sure to include the identifying code for your unknown. Cut and paste your tables and graphs into the lab report template. 6