Lung Sound Auscultation Trainer LSAT

Similar documents
Ultrasound Guided Thoracentesis Simulator

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Ultrasound Guided Thoracentesis Simulator Strap-on Type

Arterial Puncture Wrist. Instruction Manual

Ultrasound Compatible Lumbar Puncture/ Epidural Simulator

Table of Contents. Introduction. Preparation Training. After training. Maintenance. Before use P.1 Warning/ Caution. P.2-3 Included parts P.

Difficult Airway Management Simulator Assessment System

RM-80 respiration monitor

Zoll AED Pro with CPR Stat-Padz & audio recording

MEDIANA HEARTON AED A15. Mediana Automated External Defibrillator A15

M58 Newborn Vital Signs Examination Simulator. Instruction Manual

CVC Insertion Simulator

Pre-filter for Brushless Blower Instruction Manual

1. Features CONTENTS. English

Instruction Manual. Auto Inflate Blood Pressure Monitor

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

English. Quick Guide MS-TS Precision and Analytical Balances

SHIMADZU LC-10/20 PUMP

User Manual. Precision and Analytical Balances ME-T

Ultrasound Guided Thoracentesis / Pericardiocentesis Simulator Full set

Arterial Puncture Wrist

Distinguishing Features

AED Trainer NF1200-T. Operator s Manual

Stroller. Sprint S T R O L L E R S P R I N T

Simulation for emergency care

Difficult Airway Management Simulator

6900 Maintenance Instruction System Flush

User s Guide. CO2 & O2 Controller for miniature incubators

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

User Manual for the Mars Calibration Bench

User Manual. Low Shear Viscometer LS 300. prorheo GmbH Bahnhofstr. 40/ Althengstett Tel

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

ACCESSORIES FOR EVERY RESCUE

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

User s Guide. Pressure Controller for liquid delivery systems

77-I0PN230 Rev. A. Model 1030 User Manual

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Hi Flow Stroller H I F L O W S T R O L L E R

User s Guide. CO2 Controller for miniature incubators

CRiSis MANIKIN AUSCULTATION UPDATE PACKAGE LF03967U INSTRUCTION MANUAL

DIRECTIONS FOR USE / ASSEMBLING

ShellPa. Standard Mechanical Cell Stretch System Model No: NNMS Serial #: User Manual

CONSUMER MODEL INSTALLATION GUIDE

INSTALLATION MANUAL JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. Before installation. Installation INSTALLATION MANUAL: B700

LX Compass module 3 Electronic compass device User manual

TME CH LM R L A 7 T- M M L-T CHR ALM TME

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

ANZAI AZ-733VI. Respiratory Gating System. since 1976

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

BMR 2100XL Operating Instructions Page 1 of 13

Overview. The user must follow the instructions below.

MULTITUBE BUBBLE TUBE BY ROMPA (U)

All Purpose AP-Series Operation Manual

Respiration. Exercise 1A: Breathing in Resting Volunteers Aim: To measure breathing parameters in a resting individual.

Defibtech AED Training Equipment. User Manual

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

The ICC Duckworth-Lewis-Stern calculator. DLS Edition 2016

VEVO 2100 ULTRASOUND USER GUIDE

Notes Before Use...2 Notes on charging your watch...2. Your Watch...4 Name of Components...6 About the crown...7

HeartSine samaritan PAD. SAM 450P Trainer model TRN User Manual

Portable oxygen concentrator

Breeze Suite Quick Start Operator Manual. An Introduction to Pulmonary Function Testing

PT-054. PT-054 Instruction Manual Printed in China VM730901

Med Aire Alternating Pressure Pump and Pad System

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

This symbol denotes what could lead to serious injury or death if you misuse the PAR-F27MEA. WARNING CAUTION

1. Features. 3English

Getting Acquainted. Center dial hand

Edge Isolation Tool. Standard Operating Procedure. Version 1.1. Date: Prepared by, Sandeep S S. Department of Electrical Engineering

SOP for use of the SX19 Stopped-Flow Instrument

Approach. S3 Owner s Manual. May _0B Printed in Taiwan

6800 Maintenance Instruction System Flush Procedure

Tru Flight TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM

testo Leakage detector for refrigerants Instruction manual

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Contents. Page. Page. System Settings 10. Components 3. Basic Operation 4. Brightness. Volume (for use with sat nav software only) Play Golf

User s Manual. USB Golf Simulator. Contents

Magic Carbo CMV1.3. Carboxytherapy Equipment. User Manual

Warranty The device shall have a 6-year warranty at minimum

WELCOME TO THE REVOLUTION

Steel, silver - Weight metal frame ~ 30 kg W D H V (speed)

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU

PitchTracker Softball User Guide

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

BEFORE USING B. SETTING THE TIME AND CALENDAR C. FUNCTIONS OF SOLAR POWERED WATCH

UPPER ARM INTRA-MUSCULAR INJECTION SIMULATION KIT USER MANUAL

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

ASG-SD2500 ASG-SD2500

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

ANALYTICAL BALANCE OPERATING MANUAL. U.S. Solid USS-DBS Models All Rights Reserved Page 1 USS-DBS MODELS

Experiment B-18 Heart Rate and Coughing

PT-EP06 Instruction Manual

Tennis...32 Stay above...34 Decimal...36 Bundesliga simulator...38 Shooter management...41 Installation...43 Registration...45 Where do I get the

Safety precautions (IMPORTANT)

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

Transcription:

Lung Sound Auscultation Trainer LSAT This device is a simulator for medical education, which is designed to facilitate total hands-on training in auscultation skills for pulmonary disorder.. Lung Sound Auscultation Trainer LSAT: A single-purpose simulator for lung sound auscultation training The simulator is designed for training in medical diagnosis education. Do not use it for other purposes. Please read the instructions carefully before using. Do not use the system in a way other than hereinafter prescribed by manufacturer. Otherwise it may lead to deterioration in the security function. Lung Sound Auscultation Trainer LSAT: Outstanding sound quality:cases were recorded from actual patients Accurate location and spread of lung sounds The torso rotates on the base allowing examination of both front and back as in a real clinical procedure. Efficient selection of the 35 cases based on classification standards of the American Thoracic Society. Useful explanation windows - including illustrations, chest radiographs and CT images 1

DOs and DON Ts DOs Please operate the system under the designated circumstances Power input: AC 220V-240V 50Hz, 60Hz/ Max220W Temperature range: 10 degrees C 40 degrees C Relative humidity; less than 85 per cent (no condensation) Safe disposition To allow safe operation, please locate the units with sufficient space around the switches on each part of the system. Inappropriate disposition may cause serious accident. Follow the instruction on labels Warning label indicates there is a danger of an electric shock when the part is opened up. Opening up any lids, caps or covers with warning labels is discouraged. Never run the system while the warning labeled part open. When you need to open these parts, cut off the power completely well in advance and use abundance of caution all the time. There will be no compensation considered by the manufacturer for any damage or loss alleged to have been caused by the simulator, if the labeled part(s) have been opened inappropriately. Handle with care The models consists of special compositions of soft resin. Please handle them with the utmost care at all times. Storage The system is precision equipment. Store it room temperature, away from shock, heat, moisture and direct sunlight. Storage under the high temperture over 50 degree C may cause deterioration in the quality of the system.. DON Ts Never wipe the models and pads with thinner or organic solvent. Don t mark on the models with pen or leave any printed materials in contact with their surface. Ink marks on the models are not removable. In the event of the disposal of the simulator, follow the laws and rules by local authorities where it is being disposed.

Name of the Parts 1.LSAT model unit 2. Audio cable (long cable) 1 5 4 3.Power supply cable 4.PC (OS.Windows2000Pro) a 12chD/A PCI board (installed) a power supply cable / a mouse 7 6 a 109 keyboard / Windows2000Pro 5.TFT monitor a power supply cable/ manual (Japanese)/ monitor cable 6. Power amplifier 7.Speaker. 8.Speaker cable 3 NO STETHOSCOPE IS INCLUDED. 2 8 Set includes 1.LSAT Model unit----------------------------------- 1 2.Audio cable (long cable)------------------------- 1 3. Power supply cable (excludes cable for PC/monitors )-- 2 4.PC (OS.Windows2000Pro)----------------------- 1 5.TFT monitor --------------------------------------- 1 6.Power amplifier ------------------------------------ 1 7.Speaker----------------------------------------------- 2 8.Speaker cable---------------------------------------- 2 9.T shirt------------------------------------------------- 1 10. Instruction manual -------------------------------- 1 9 3

Connection of LSAT Simulator K LSAT Amplifier Audio cable PC PS Audio cable Speakers Monitor LSAT model unit PS PS Main power supply cable OUTLET PS: Power supply cable When the LSAT system is installed separately, the power supply codes are pluged directly into outlet. to connect both models simultaneously an audio distributor is required. 1) Connect the power amplifier to the computer. 2) Connect model unit(s)to the power amplifier with the audio cable(s). 3) Plug the power supply cables of the model unit, the PC, the TFT monitor and the power amplifier into the outlets. 5

Operation: Simulator LSAT: D1-D3 D1. Open the LSAT system Going through procedures B1-B5, Microsoft Windows 2000Pro is started up. Open thelsat system by double-clicking at the icon. D2. Chosing a case Opening window OK: open a case Category buttons Case list Choose a group of cases by clicking one of the category buttons. Then select a case by clicking a name listed in the box on the right side. Please note: <H> indicates that the case is replayed with normal heart sounds. Most cases are provided with 2 options, with and without heart sounds. By clicking OK button on the top, or double clicking at the case name, the selected case is opened up. 11

D3. Running the simulation Operation window Speaker numbers Sound chart:anterior Sound chart: Posterior Speaker numbers Click button on the toolbar to start running the simulation. Default duration of the simulation is 30 min. Changes and differences in lung sounds on each area can be distinguished using an actual stethoscope. The numbers at the left side of the sound chart indicates the number of speakers embedded in the torso model. Both posterior and anterior lung sounds are programmed for training. Anterior Posterior Counter clockwise Clockwise The posterior/anterior sounds can be switched over by rotating the torso model. Please note: The sound sets are played on only one side at a time. It is not possible to play both posterior and anterior sound simultaneously. 12

To open another set of cases, click button. To quit the LSAT system, click. When you finish the session completely, follow the shut-down procedure. Explanation button opens useful explanation window for each case. 13

System configuration E1-E4 E1 :Display preferences By clicking monitor button, display configuration window is opened up. When the 'Free' setting is marked each element can be selected separately to create user's own display. The prepared display settings can also be swiched over by using function keys during the simulation. Simulator K F1: Standard LSAT F1: All area F2: ECG and PCG F2: Right area F3: PCG F3: Left area F4: ECG F4: None F5:Free F5:Free E2 :Sound Volume By clicking the volume button, volume adjustment window opens to adjust the sound volume of each embedded speaker. 14

E2 :Air pressure, simulation speed and time of duration. By clicking the volume button, the speed/time control window opens to adjust air pressure for cardiac impulses (Simulator K only), speed of simulation and duration of the running time. Air pressure control works for Simulator K only Please note: The running speed affects the sound frequency. When the simulation runs rapidly, the pitch of the sounds becomes higher and makes a higher tone accordingly. E3 : Display color preference By the control button, color control window is opened. E4 : Toolbar From the toolbar button, elements of toolbar can be selected 15