Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04

Similar documents
Hydraulic hand test pump Models CPP700-H and CPP1000-H

Neotecha Tank Sampling Sapro

Shafer Gas-Hydraulic Tanks Replacing Hydraulic Fluid Procedure on an Existing Actuator

Product Data Sheet L-TRDD-D Rev. 1 November Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Axial piston pumps type PVC

Axial piston pumps type PVC

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

Introduction. Part one: Identify the Hydraulic Trainer Components

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

directional control valve series cv691

Roxar 2 System Mechanical Retrieval Tool

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

Roxar 2 System Mechanical Retrieval Tool

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Shafer RV-Series Rotary Vane Valve Actuators

MEGR-1627 Instruction Manual

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400

3-Way Safety Block DSV

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

Oil connector 3/8NPT. usable oil Air inlet pressure max. operating Air consumtion. oil capacity capacity min. max.

COP700 / COP1400 Operating manual for comparison test pump COP700 / COP1400

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Pressure reducing valve, pilot operated, Model 3DR

Priority (Swing) Motors Data and Specifications

Accessories. Valves. Adjustable Pressure Relief Valves

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

VACUUM REGULATORS CONTENTS

PRESSURE REGULATORS. Type A/140. Process Management TM

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Fisher 2625 and 2625NS Volume Boosters

Liquid Level Controllers

Pressure Independent Control Series

Accessories. Valves. Adjustable Pressure Relief Valves

Hydraulic Punch Drivers

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

SDM to 8 sections monoblock valve D1WWDA02A

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Leak-Free Load-Control Valve SAE ½ psi flange

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Safety and Shut-off Block SAF/DSV

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

Safety and Shut-off Block SAF/DSV

STAD-C. Balancing valves DN 15-50

Safety and Shut-off Block SAF/DSV

DK ton, Double-acting, Die-type Crimping Tool

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

KJ4000 Operating Instructions & Parts Manual NSN

Leak free Pipe Rupture Valve for Excavators

Float Operated Level Controllers

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

PRESSURE REGULATORS. Type B/240. Process Management TM

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Directional Control Valves Technical Information Model 1500

Types 749B and R130 Changeover Manifolds

Air Eliminators and Combination Air Eliminators Strainers

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Electrically Operated Pressure-Relief Cartridge, Size 10

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Cooler-Bypass Thermostat Valve, Size 16

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Monoblock Directional Control Valve RMB 202

MEGR-1912 Instruction Manual

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Fitted with a main pressure relief valve and a load check valve on every working section.

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Fisher L2sj Low Emission Liquid Level Controller

RESIDENTIAL REGULATORS

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Operating Instructions Model and Hydrostatic Test Pump

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

64 Series Pressure Reducing Regulators

Two-port valves, male threaded, PN25

R S 280 is a modular parallel sect. Directional Control Valve RS RS In relation to its flow capacity its installation

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

Technical Data Sheet TI-F50 Locking Units series KFH

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE

User Manual Pressure Calibration System C and Hydraulic Pressure Pump Models T-620/T-620H Copyright 2008 AMETEK Denmark A/S

RESIDENTIAL - IRRIGATION - WATER TREATMENT OF FLORIDA PUMP PROTECTION - EFFICIENCY - ENERGY SAVER - COMFORT

Transcription:

Damcos PHP 25-05 Portable hand pump unit 5 l Product Data Sheet September 2014 SD 6601-2E04 TM

Damcos PHP 25-05 September 2014 General description Double-acting portable hand pump incl. 5 l. reservoir and built-in 4/3-way pilot valve for opening and closing of valves mounted with actuators or LPU. The pump is mounted with female screw connections, which fit the male part mounted on LPU connection or mounting blocks. This hand pump can be used in different ways: As portable, where it can operate actuators and LPUs in different areas of the vessel. As firmly mounted, with tank mounted on the bulkhead - specially for large actuators, for more details contact Emerson Process Management. As filling device for LPUs and Actuators. Main Data Max. system working pressure: Max. system test pressure: Max. hand pump pressure: Safety valve settings: Weight with 5 l. oil: Material: Oil displacement per double stroke: Oil viscosity range: 135 bar - 1960 lbf/in² 205 bar - 2970 lbf/in² 300 bar - 4300 lbf/in² 180 bar 20 kg - 44 lbs aluminium, painted steel and rubber hoses 25 cm3-525 in3 15-300 cst Temperature range: -15 C to 80 C - 5 F to 176 F Operation for Actuators In a 2-line system (double acting) Recommended oil filtration: Standard hose: Should meet or be better than NAS 1638/10 or ISO Solid contaminant code 21/19/16 4 m, other hoses on request Opening of valve: Close the stop valves on the control block mounted on the actuator. PHP Hydraulic Diagram Connect the hoses B and A to the emergency control block (e.g. CB-block) mounted on the actuator. Turn the pilot valve on the hand pump to open position and continue to pump until the actuator or pressure gauge for nominal working pressure 135 bar. The valve is prevented from closing when the pilot valve is placed in centre position. Closing of valve: Turn the pilot valve on the handpump to closed position - otherwise as above. In a 1-line system (single acting) Opening of valve: Only hose B is used - otherwise as above. Closing of valve: Turn the pilot valve on the hand pump to closed position. The actuator/valve closes without pumping. Oil Filling Only cleaned oil must be added to the hand pump. For more details, see our oil filling instructions. Note!N After operation disconnect the hoses from the control block on the actuator and open the stop valves again. 2 www.emersonprocess.com

Damcos PHP 25-05 September 2014 Operation for LPU/Actuator Manual / Emergency operation of double acting LPU/Actuator OPEN: Manual / Emergency operation of single acting LPU/ Actuator OPEN: Connect hand pump B hose with B-line quick connection at the LPU. Connect hand pump B hose with B-line quick connection at the LPU. 2. Connect hand pump A hose with A-line quick connection at the LPU. 2. 3. Turn the pilot valve on hand pump to open position and continue until the actuator or pressure gauge for nominal working pressure 135 bar. Connect hand pump A hose with T-line quick connection at the LPU. With suction to T and pressure to B the shuttle valve will change over and prevents the oil from flowing to tank. 3. Turn the pilot valve on hand pump to open position and continue until the actuator or pressure gauge for nominal working pressure 135 bar. 4. Valve is prevented from closing when the pilot valve is placed in center position. 4. Valve is prevented from closing when the pilot valve is placed in center position. CLOSE: Turn the pilot valve on the hand pump to closed position - otherwise as mentioned above. CLOSE: www.emersonprocess.com Hose could be removed or handle placed in remote position. 2. To close - open the bypass valve on the actuator. 3. Close the bypass valve after operation and remove the hose if not already done. 3

21 131 Damcos PHP 25-05 September 2014 Main Dimensions Hand pump 150 137 Dimension lever to put inside 15 mm x 30 mm Fitting for pipe Ø 10 mm N 4 holes Ø 11 Check coupling G 1/8 90 24 15 Level gauge 185 316 Aluminium Level gauge 75 135 180 210 26 75 135 168 224 4 www.emersonprocess.com

September 2014 Damcos PHP 25-05 Console www.emersonprocess.com 5

Damcos PHP 25-05 SD 6601-2E04 Product Data Sheet September 2014 2014 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Damcos and the Damcos logotype are trademarks of Damcos A/S. All other marks are the property of their respective owners. Emerson Process Management Damcos A/S Aaderupvej 41 DK-4700 Naestved T +45 5578 7200 F +45 5578 7272 www.emersonprocess.com/mtm The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. Standard Terms and Conditions of Sale can be issued by contacting Damcos A/S. We reserve the right to modify or improve the designs and specifications of our products at any time without notice. Damcos A/S accepts no responsibility for any errors that may appear in this publication. TM