International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) ICO-OSCAR Instructor Directions

Similar documents
International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR)

ASICO Innovative I/A Tip System (Patented) Maximize your I/A efficiency for Today s MICS and FLACS procedure

Manual Small Incision Cataract Surgery

Injector system for implantation of 1stQ foldable intraocular lenses

Getting Started GUIDE LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL pg 1

Basic Concept & Techniques of Phaco Prechop

Ophthalmology Clinical Pearls A Quick Guide To Crystalens

Scleral Fitting Guide

Ophthalmic Surgical Instruments

Ophthalmic Surgical Instruments

Insert to. Sponsored by Alcon Laboratories, Inc. February 2014 EXPLORING THE CATARACT REFRACTIVE SUITE FEATURING. The CENTURION Vision System

Management of corneal wounds: some practical tips. Lee SH, MD, FRCS (C ), FAAO

BIORAPTOR Knotless Suture Anchor Arthroscopic Shoulder Instability Repair. Shoulder Series Technique Guide by: Thomas Youm, MD

surgical instruments catalog German Engineering. American Design. World-Class Quality.

OPESAVER Super Irrigation System

Rating Phaco Chop Techniques

VHC Vitamin-D Accurate Sample Preparation. VHC Vitamin-D Quantitative Vitamin D Test [REF] 1000J-10/-25/-50

In November 1998, the Staar AA4203 toric intraocular. Early rotational stability of the longer Staar toric intraocular lens. Fifty consecutive cases

Reusable Ophthalmic Instruments

Andre Litwin BM FRCOphth Consultant Ophthalmologist and Oculoplastic Surgeon

Single-use Ophthalmic Instruments

Important / remember. Accessing the edge of the crevasse to evaluate the situation

25+ instruments answer the most common barrier to 25G instrument flexibility.

No guesswork. Controllable tension for labral repairs of the shoulder and hip. BIORAPTOR Knotless Suture Anchor

Sterile, Single-use, Instruments

PERFORMANCE MANEUVERS

THERMALLING TECHNIQUES. Preface

Single-use Ophthalmic Instruments

Chest Drains. All Covenant Health Intermediate Care Nursery staff. Needle Aspiration

General Rescuer Task Book

CURETTES - SCRAPERS - SPOON - SPATULAS

K-1. Body Parts in Locomotion! Movement Skills: Locomotor

Veterinary Science Handling and Restraining Practicum. Restraint of the Cat for Cephalic IV Catheter Placement

LENS EXCHANGE WITH IMPLANTATION OF A BITORIC INTRAOCULAR LENS IN EYES WITH SIGNIFICANT ASTIGMATISM AFTER PREVIOUS CORNEAL SURGERIES

CATALOG CATALOG. Pioneer in Ophthalmic Products. BACK FLUSH INSTRUMENTS VITREORETINAL INSTRUMENTS

T H E M O S T I M P O R T A N T L E S S O N O F A L L

OFFICIAL YOUTH CATTLE WORKING CONTEST RULES

Adjust the Volume Display

Chapter 2. Pipetting techniques. Guide to Pipetting

Port - Body in a Box User s Manual

FITTING AND TROUBLESHOOTING SCLERAL LENSES

Balancing/Transferring Weight Rubric-Kindergarten

Appendix C: Skill Stations Examination - Marking Rubric

Triple EK/CE/IOL has a cataract needs both DMEK and CEIOL

Front Cover Picture Mark Rasmussen - Fotolia.com

Unity Sleeveless Elevated Vacuum System

DIAGNOSTIC CARDIOLOGY

Presented By Kirk Walker, Head Softball Coach Oregon State University

The Visual Technique Circuit: An alternative method for teaching marching fundamentals. CBDNA Athletic Band Symposium, 2017

Rotator Cuff Solution. Combined Strengths. Precise Control. TWINFIX Ultra FOOTPRINT Ultra Suture Anchors

DISCLOSURES FITTING AND TROUBLESHOOTING SCLERAL LENSES WHO S A GOOD CANDIDATE SCLERAL LENS ADVANTAGES ANDREW J. BIONDO, OD, FSLS.

Rock, Paper, Scissors Locomotion!

AUSTRALIAN BASEBALL UMPIRE S MANUAL

An introduction to modern scleral lenses

IMPLANTS & INSTRUMENTS FOR TISSUE REPAIR

MyoSure Setup Simplified

INTERNATIONAL SKATING UNION

RayPette Plus Autoclavable Pipette. User Manual

4-H HORSE SHOW JUDGING STANDARDS

Lesson Author: Adapted from Tom Lochhaas How to Tack a Sailboat:

Section 2.9 Decannulation

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

FÉDÉRATION INTERNATIONALE DE GYMNASTIQUE

Introduction to Guideline Procedures - Part 2: Methods

Inflatable Dock Slide Owner s Manual

The DAFO Guide to Brace Selection

Water Rescue Course (Surface- and Swift- Levels I&II) Task Book

Junior Olympic Trampoline & Tumbling Guide To Judging

U16 & U19 Universal Player Evaluation 3. Game Play Offensive Goalie Evaluation Criteria: Skills for Assessment Overview:

Standard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610

KAPPA KWIZ BOWL - Game Play Rules The following are the rules and format for the Kappa Kwiz Bowl

The pipettes cover a volume range from 0.1µl to 10ml.

These guidance notes should be used together with the Climbing Wall Development Instructor handbook.

Tracheostomy Tube Security Device

Pipettor. User Manual

Lesson Author: Adapted from Tom Lochhaas How to Tack a Sailboat:

Teachings From An American Style Fighter Kite

How images are formed in the eye

February 2011 Australasian Road Rescue Organisation Command Guideline

Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide

MAGNETS IN THE EXTRACTION OF INTRA-OCULAR FOREIGN BODIES. foreign bodies were removed from within the globe; in one day,

Study & Manipulative Training Guide

Biometry tips. Marilyn Watkins-Ramdin, COMT ROUB

Eye Injuries. Chapter 25

LENSTAR LS 900 Setting the standard in optical biometry

Sample Biomechanical Report

Ocular hazards of playing squash

5200 Lawrence Place Hyattsville, Maryland 20781, USA Toll Free: Phone: Fax:

Determination of Grades of Execution Singles Skating Free Program

FORCEPS ¾, (12CM) 12 cm long, flat handle 9 mm wide, straight tip 0.3 mm dia. fine ¾, (12CM) fine

Veterinary Science Handling and Restraining Practicum Restraint of the Small Dog for Jugular Venipuncture. Participant Name: Letter/#: School:

XI.C. Power-Off Stalls

OPHTHALMOLOGY THE BRITISH JOURNAL APRIL, 1925 COMMUNICATIONS TONOMETRY* SCHI6TZ. OPHTHALMOLOGY for May and June, 1920, I gave an account

ATA SONGAHM TAEKWONDO JUDGING CERTIFICATION LEVEL 1 TEST

INFUSION SYSTEM (110V) (220V) USER S MANUAL

JULL SURG OPHTHALMIC INSTRUMENTS MOORFIELDS SRTABISMUS HOOK OP-8164 CHAUVASSE STRABISMUS HOOK OP-8165 LENS EXPRESSOR OP-8166 SNELLEN VECTIS OP-8167

Work Instructions. Title: Mouse Restraint Techniques 1. GENERAL GUIDELINES

Rigging it Right. Presented by Ron Barwick Service Manager for Half Hitch Hosted by: Bob Fowler

THE TOP 100 KEYWORDS FOR AN

Transcription:

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) The International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubrics (ICO-OSCARs) are designed to facilitate assessment and teaching of surgical skill. Surgical procedures are broken down to individual steps and each step is graded on a scale of novice, beginner, advanced beginner and competent. A description of the performance necessary to achieve each grade in each step is given. The assessor simply circles the observed performance description at each step of the procedure. The ICO-OSCAR should be completed at the end of the case and immediately discussed with the student to provide timely, structured, specific performance feedback. These tools were developed by panels of international experts and are valid assessments of surgical skill. ICO-OSCAR Instructor Directions 1. Observe resident cataract surgery. 2. Ideally, immediately after the case, circle each rubric description box that you observed. Some people like to let the resident circle the box on their own first. If the case is videotaped, it can be reviewed and scored later but this delays more effective prompt feedback. 3. Record any relevant comments not covered by the rubric. 4. Review the results with the resident. 5. Develop a plan for improvement (e.g. wet lab practice/tips for immediate next case). Suggestions: If previous cases have been done, review ICO-OSCAR data to note areas needing improvement. If different instructors will be grading the same residents, it would be good that before starting using the tool they grade together several surgeries from recordings, so they make sure they are all grading in the same way.

ICO-Ophthalmology Surgical Competency Assessment Rubric: Extracapsular Cataract Extraction (ICO-OSCAR: ECCE) Date Resident Evaluator 1 Draping Novice (score = 2) Unable to start draping without help. Drape needs to be redone. Beginner (score = 3) Drapes with minimal verbal instruction. incomplete lash coverage. Advanced Beginner (score = 4) Lashes mostly covered, drape is at most minimally obstructing view. Competent (score = 5) Lashes completely covered and clear of incision site, drape not obstructing view. Not applicable. Done by preceptor (score= 0) 2 Eye position and stability Unable to stabilize eye in good Achieves acceptable eye position and stability with some difficulty. Achieves good eye position and stability. Precisely and consistently stabilizes eye in good 3 Scleral access & Cauterization Unable to successfully access sclera. Cauterization insufficient or excessive both in intensity and localization. Accesses sclera but with difficulty and hesitation. Cauterization insufficient or excessive in location or intensity. Achieves good scleral access with mild difficulty. Adequate cauterization. Precisely and deftly accesses sclera. Appropriate and precise cauterization. 4 Scleral or Corneo-scleral Incision Inappropriate incision depth, location, and size. Only one of the following is done correctly: incision depth, location or size. Only two of the following are done correctly: incision depth, location or size. Good incision depth, location and size. 5 Viscoelastic: Appropriate Use and Safe Insertion Unsure of when, what type and how much viscoelastic to use. Has difficulty or multiple unsuccessful attempts at accessing anterior chamber through paracentesis. Requires minimal instruction. Knows when to use but administers incorrect amount or type. Requires minimal instruction. Uses at appropriate time. Administers adequate amount and type. Cannula tip in good Viscoelastics are administered in appropriate amount and at the appropriate time with cannula tip clear of lens capsule and endothelium with no instruction. 6 Anterior Capsulotomy Awkward or rough movements of cystitome, digging too deep or too superficial, lens movement endangers zonules, poor control risks radialization. Difficulty initializing and keeping flap everted. Either awkward or rough movements of cystitome but not both; depth of attempts adequate but not optimal, some lens movement, intermittent poor control of capsulotomy. Minor difficulty everting the flap. Gentle but imprecise movements of cystitome; depth of attempts adequate but may not be optimal OR some lens movement OR intermittent poor control of capsulotomy. Gentle precise movements of cystitome; depth and control correct for appropriately sized capsulotomy. 2

7 Wound Enlargement Inappropriate wound architecture and/or size, iris is damaged during the maneuver. Incomplete enlargement, loss of tissue plane, residual strands across incision. Iris prolapse, leakage with local pressure. Provides poor surgical access to and visibility of capsule and bag. May be mild leakage, allows adequate extraction of nucleus. Incision edges not parallel. Beveled precise parallel incision edges, no iris prolapse, allows easy extraction of nucleus. 8 Nucleus Hydrodissection Rough and incomplete hydrodissection of lenscapsular adhesions preventing lens rotation or extraction, not recognized by surgeon. Hydrodissection is rough or incomplete but able to recognize and correct with multiple attempts. Hydrodissection and lens mobilization is imprecise but accomplished in one to several attempts without assistance. Precise and controlled hydrodissection. 9 Nucleus Extraction Attempt causes radialization of capsulorrhexis or tear in posterior capsule; unable to hold and extract lens nucleus. Movements coordinated but still unable to extract nucleus. Uncoordinated and imprecise movements but with successful lens nucleus extraction. Nucleus removed with dexterity, well controlled movements and technique. 10 11 Irrigation and Aspiration Technique With Adequate Removal of Cortex Lens Insertion, Rotation, and Final Position of Intraocular Lens Great difficulty introducing the aspiration tip under the anterior capsule, aspiration hole position not controlled, cannot regulate aspiration flow as needed, cannot peel cortical material adequately, engages capsule or iris with aspiration port. Unable to insert IOL. Moderate difficulty introducing aspiration tip under anterior capsule and maintaining hole up position, attempts to aspirate without occluding tip, shows poor comprehension of aspiration dynamics, cortical peeling is not well controlled, jerky and slow, capsule potentially compromised. Prolonged attempts result in minimal residual cortical material. Insertion and manipulation of IOL is difficult, eye handled roughly, anterior chamber not stable, repeated attempts result in borderline incision for implant type. Repeated hesitant attempts result in lower haptic in the capsular bag, upper haptic is rotated into place. Minimal difficulty introducing the aspiration tip under the anterior capsule, aspiration hole usually up, cortex will engaged for 360 degrees, cortical peeling slow, few technical errors, minimal residual cortical material. Some difficulty in removing sub-incisional cortex. Insertion and manipulation of IOL is accomplished with minimal anterior chamber instability, incision just adequate for implant type, the lower haptic is placed inside the capsular bag with some difficulty, upper haptic is rotated into place. Aspiration tip is introduced under the free border of the anterior capsule in irrigation mode with the aspiration hole up, Aspiration is activated in just enough flow as to occlude the tip, efficiently removes all cortex, The cortical material is peeled gently towards the center of the pupil, tangentially in cases of zonular weakness. No difficulty in removing sub-incisional cortex. Insertion and manipulation of IOL is performed in a deep and stable anterior chamber and capsular bag, with incision appropriate for implant type. The lower haptic is smoothly placed inside the capsular bag; the upper haptic is rotated or gently bent and inserted into place. 3

12 13 14 Wound Closure: Suture handling & Placement Wound Closure: Suture tying & Knot rotation Global Indices 15 16 17 18 Wound Closure: viscoelastic removal, wound hydration, wound security Wound Neutrality and Minimizing Eye Rolling and Corneal Distortion Eye Positioned Centrally Within Microscope View Conjunctival and Corneal Tissue Handling Intraocular Spatial Awareness 19 Iris Protection Cannot reliably load suture. Instruction is required and stitches are placed in an awkward, slow, non-radial fashion with much difficulty, consistently in the wrong 13tissue plane, has to repeat same stitch. Unable to get tension correct, multiple corneal striae present, incorrect number of throws, knots often not buried. Unable to remove viscoelastics thoroughly. Unable to make incision water tight or does not check wound for seal. Improper final IOP. Nearly constant eye movement and corneal distortion. Constantly requires repositioning. Tissue handling is rough and damage occurs. Instruments often in contact with capsule, iris or corneal Iris constantly at risk, handled roughly. Some difficulty loading and placing sutures, often in wrong tissue plane, resuturing may be needed. Sutures not radial or appropriately spaced. Uneven suture tension, some corneal striae, number of throws usually correct, most knots buried. Questionable whether all viscoelastics are thoroughly removed, Extra maneuvers are required to make the incision water tight at the end of the surgery. May have improper IOP, but recognizes possibility. Eye often not in primary position, frequent distortion folds. Occasional repositioning required. Tissue handling borderline, minimal damage occurs. Occasional accidental contact with capsule, iris and corneal Iris occasionally at risk. Needs help in deciding when and how to use hooks, ring or other methods of iris protection. Able to load sutures consistently. Stitches are placed with minimal difficulty usually in correct tissue plane. Sutures mostly radial and of adequate length and space between sutures. Sutures tied tight enough to maintain the wound closed, may have slight corneal distortion, rare knot not buried adequately. No corneal striae. Viscoelastics are adequately removed after this step with some difficulty. The incision is checked and is water tight or needs minimal adjustment at the end of the surgery. May have improper IOP but recognizes and treats IOP. Eye usually in primary position, mild corneal distortion folds occur. Mild fluctuation in pupil Tissue handling appropriate but potential for damage exists. Rare accidental contact with capsule, iris and corneal Iris generally well protected. Slight difficulty with iris hooks, ring, or other methods of iris protection. No difficulty loading or placing sutures consistently in correct tissue plane. All sutures radial and of adequate length and space between sutures. Sutures are tied tight enough to maintain the wound closed, but not too tight as to induce astigmatism. All knots buried. Viscoelastics are thoroughly removed after this step, the incision is checked and is water tight at the end of the surgery. Proper final IOP. The eye is kept in primary position during the surgery. No distortion folds are produced. The length and location of incisions prevents distortion of the cornea. The pupil is kept centered during the surgery. Tissue is not damaged nor at risk by handling. No accidental contact with capsule, iris or corneal Iris is uninjured. Iris hooks, ring, or other methods are used as needed to protect the iris. 4

20 Overall Speed and Fluidity of Procedure Hesitant, frequent starts and stops, not at all fluid. Case duration greater than 60 Occasional starts and stops, inefficient and unnecessary manipulations common, case duration about 60 Occasional inefficient and/or unnecessary manipulations occur, case duration about 45 Inefficient and/or unnecessary manipulations are avoided, case duration is appropriate for case difficulty. In general, 30 minutes should be adequate. Comments: Golnik KC, Beaver H, Gauba V, Lee AG, Mayorga E, Palis G, Saleh GM. Cataract surgical skill assessment. Ophthalmology. 2011 Feb;118(2): 427.e1-5. Adapt and translate this document for your non-commercial needs, but please include ICO attribution. Access and download ICO-OSCARs at icoph.org/ico-oscar 5