EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Similar documents
EasyLine Continuous Gas Analyzers. So smart, they re simple

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

LFE OEM TCD - Thermal Conductivity Detector

FTC130 Transmitter. Operating Manual

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

GasSense NDIR User Manual

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Supplementary Operator s Manual 42/24-14 EN Rev. 3

better measurement Simply a question of

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

HumiSys HF High Flow RH Generator

Flow metering in gases Introduction to COMBIMASS family

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Best Practice Guide, Servomex 2700

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

deltaflowc deltaflowc Venturi or Probe

Transmitter CS 21 Operation Manual

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Instruction Manual. Biogas Analyzer InCa Bio 04

FAS-W. Features. Applications. Automatic condensation hygrometer

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Technical Data Sheet MF010-O-LC

Gas Module for Series GMS800

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

LT GasAnalyzer beyond standards

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Mass Flow Controller (MFC) for Gases

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Mass Flow Controller (MFC) for Gases

Columbus Instruments

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Transmitter CS 21 Operation Manual

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

PRODUCT CONFORMITY CERTIFICATE

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

ACV-10 Automatic Control Valve

FLAMMABLE GAS SENSOR/TRANSMITTER

Autocalibration Systems For In Situ Oxygen Analyzers

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

PHOENIX L300i Best-in-class Helium Leak Detectors

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

TH-1800-T TRX-700-CNG Converter

Online data sheet FLOWSIC30 GAS FLOW METERS

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

C-Flow Coriolis Mass Flow Meters

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

BUBBLER CONTROL SYSTEM

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Installation and Operation Manual

Model 601CV. Mass Flow Controller. Product Features:

Gas Pressure Regulator HON 200

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Mass Flow Meter (MFM) for Gases

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

BUBBLER CONTROL SYSTEM

Vortex Meters for Liquids, Gas, and Steam

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

MMS Mercury Monitoring System for Natural Gas

Model EXAxt AV550G. Averaging Oxygen Analyzer

Pneumatic high-pressure controller Model CPC7000

PRODUCT OVERVIEW. Gas mixers Test bench systems Leak test and impermeability testing systems High pressure dosing pumps

Visualize Nitrogen Gas Consumption

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

Applications Note: Use of "pentane equivalent" calibration gas mixtures

LUMAZOTE T ECHNICAL BRO CHU RE

Electro-Pneumatic Converter YT-940 SERIES

1 Overview. Extractive continuous process gas analysis Series 6 ULTRAMAT 6. General information

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

ABB MEASUREMENT & ANALYTICS DATA SHEET. EasyLine EL3000 Series Continuous gas analyzers

analytical bulk flow distance FLOW level pressure temperature industrial communication

780S Ultra High Purity Series

High-performance submersible pressure transmitter For level measurement Model LH-20

Model PDT Dewpoint Transmitter

OXYGEN MONITORING SYSTEM OMS

Quick Installation Guide Doc nr.: C Date:

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Transcription:

P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Proven Analyzer Technology Measuring total hydrocarbons The EuroFID measures total hydrocarbons in air, in corrosive as well as in condensing gases at process temperatures up to 350 C. In trace concentrations up to 100 vol%. EuroFID is modular and can be put together in a system using the best components (analyzer, terminal box, control unit) for the particular installation. Typical applications Exhaust gas measurement of hydrocarbon emissions in raw and clean gas Emission measurement in power stations and waste incineration plants Emission measurement after thermal, catalytic and biological oxidation units and after activated charcoal exhaust air cleaning systems Monitoring raw gas concentrations prior to exhaust gas cleaning units LEL measurement of potentially explosive gas mixtures during manufacturing of solvent-based products Cleanliness and quality control of solvent-based coated products Monitoring of workplace environments Monitoring carbon content in ambient air for leak detection from containers filled with solvent-based products Exhaust gas analysis from combustion engines 2 SICK EurOFID

Measuring Principle, Customer Advantages Measuring principle The gas concentration is converted into an electrical signal by means of a flame ionization detector (FID). In the FID a hydrogen flame burns in the presence of hydrocarbon-free combustion air. When the sample containing hydrocarbon molecules reaches the center of the flame, the molecules are cracked and stripped causing CH fragments to form. These fragments are oxidized by the oxygen in the combustion air and the CHO+ ions form. The ion current is measured and is proportional to the carbon ratio in the organic compounds in the sample. The sample gas is extracted from the process through the sample gas filter by means of a dual-stage jet. Sample gas is then diluted and compressed and passed on to the bypass. All parts in contact with the sample gas are heated in the sensor block to a constant temperature. The dilution rate depends only on the pressures in the jet device. These values are measured continuously by pressure sensors P1, P2 and P3. The propellant pressure of the jet device is set to a specific value. An ejector characteristic field is used to calculate the dilution from the pressure ratios. A portion of the diluted sample gas flows to the FID detector which continuously measures the gas concentration. Bypass Sample gas Filter FID Secondary nozzle Primary nozzle P1 P2 P3 Key features and advantages: Integrated sample gas dilution reduces maintenance and increases uptime. This is especially important when measuring high concentration gas mixtures which, under normal conditions, can solidify causing clogging problems. No moving parts no wear and tear, through the use of an ejector pump instead of a mechanical diaphragm pump to transport sample gas. Low maintenance because only the easily accessible sample gas filter needs to be replaced. Ideal detector geometry rigid symmetrical construction of the jet and the cylinder limits the formation of deposits within the analyzer assembly to a large extent. Heating of all of the gas contacted parts insures the prevention of condensation within the analyzer assembly. EU Type Approval according to 94/9/EU as an on-site gas warning instrument to measure hydrocarbon and derivatives in a mixture together with air in the measuring range of 0 100% LEL. BVS 05 ATEX G 005 X Heated sensor block Pressure controller Micro-controller SICK EurOFID 3

System Component Overview EuroFID modular system Analyzer unit The EuroFID system is both mechanically and electrically modular and comprises the analyzer unit, terminal box and control unit (optional: I/O terminal module). In-line version Panel version (wall mounting) Analyzer unit selection 42 V AC RS422 Terminal box Power supply 24 V DC Control unit 230/115 V AC RS422 I/O module Power supply 230/115 V AC Digital and analog inputs/outputs Process control system (Host) Printer RS232 RS232 Analog inputs/outputs: 4 x 0...10 V; 2 x 0/4...20 ma Digital inputs/outputs: 3 x 24 V DC/10 ma; 8 x 24 V AC/100 ma 4 SICK EurOFID

EuroFID Analyzer Unit The analyzer unit contains the heated sensor block, pneumatic supply and control electronics. The pneumatic supply provides operating gases for ignition, ensures continuous operation of the detector flame and dilution of the sample gas as well as delivery of calibration gases to set H 2 Instrument air Calibration gas the zero and end points. The control electronics include an electrically isolated mains adapter that supplies the required operating voltages. The analog and digital input and output signals in the analyzer unit are processed by a micro-controller and electronically isolated for data transfer via a serial RS422 interface. All instrument-specific data from the analyzer unit such as the characteristic curve of the two-stage jet device is stored in the non-volatile memory. The analyzer unit is connected to the control unit via the serial interface. Pneumatic control Process FID Pressure and solenoid valve control FID amplifier Flame control Ignition Pressure monitor Heating Power supply 42 V AC Memory Microcontroller RS422 Heated sensor block Control electronics Analyzer unit in wall (panel) mounting enclosure This type is usually fitted on the mounting plate inside of the measuring cabinet. Sample gas is supplied through a heated line. This configuration provides a cost-effective extractive emission measuring unit. In-line analyzer unit The in-line version is flanged directly to the sampling point. All of the other typical sample conditioning components such as heated lines, gas sampling probe and filter are not required. Short gas paths provide a very quick response time of < 1.5 seconds. SICK EurOFID 5

Control Unit and Analyzer Unit in 19" Design Control unit The control unit is designed according to the recommendations of the Standardization Commission of the European Chemical Industry (NAMUR). It combines all the required features such as self-explainatory menu controlled operation where additional information is available in clear text via the help key. The large backlit liquid crystal display and four light-emitting diodes (Alarm, Failure, Maintenance and OK) provide the operator with a quick overview of the measured values and instrument status. Apart from the interface to the analyzer unit, the control unit also has three additional serial interfaces to connect the I/O termi- nal strip and a laptop, a modem or any other computer or to another control unit. The following operating modes are available for instrument functions: Manual operation Fully automatic operation External control via I/O terminal module The control unit is mounted in a 19 rack with 3 height units (133.5 mm) or optionally a half-size 19 rack with 4 height units. 19" rack (3 HU) Half-size 19" rack (4 HU) Analyzer unit in 19" rack: The analyzer unit is integrated in a 19" rack which can be fitted in standard system cabinets. Together with the terminal box integrated in the control unit, the overall height of the complete analyzer is 7 height units. Example: standard system cabinet for multiple devices Industrial housing for Ex Zone 1 The In-line EuroFID in stainless steel housing is approved for use in potentially explosive areas in Zone1 (II2G EEx p IIB+H2 XXX C (XXX = 0...220 C)). Terminal box, heating (optional) and/or process gas lock-out are integrated in the pressurized housing. 6 SICK EurOFID

Technical Data Overview EuroFID Technical Data Measured Data Inline Wall housing 19" rack Industrial housing Ex Zone 1 Measurements LEL Process, emission Process emission Process emission Process LEL Measured value display 4 ½ digit and analog as bar graph Measuring range: Smallest measuring range Largest measuring range Linear range 6 measuring ranges selectable 10 ppm relative to C 3 H 8 100 % LEL Depends on measuring range, ±1 % within one decade, ±5 % over the whole measuring range. 1) 3) Detection limit < 3 % of measuring range limit value Response time (T 90 ) 2) > 1.5 s (LEL) > 2.5 s (emission) > 2.5 s without sample gas line > 2.5 s without sample gas line > 1.5 s (LEL) > 2.5 s (emission) Zero drift < 0.5 % of measuring range end value/month 1) Sensitivity drift < 3% of measuring range end value/month 1) Flow 2) Min. 0.5 l/min, max. 6.2 l/min Connection Stainless steel tube, OD 6 mm, ID 5 mm Pressure range Atmospheric, ± 50 hpa Protection class IP 54 (outer housing) IP 20 IP 20 IP 65 Approvals Gas warning device BVS 05 ATEX G005 X 2000/76/EC (17 th FICA) 2000/76/EC (17 th FICA) Gas warning device BVS 05 ATEX G005 X 2000/76/EC EX approvals II 2 G EEx p IIB+H2 XXX C with XXX = 170... 220 C Influencing parameters Ambient pressure < 0.5 % of measuring range end value 1) /10 hpa Sample gas pressure < 1.0 % of measuring range end value 1) /10 hpa Zero point < 2 % of measuring range end value 1) /10 K Sensitivity < 1 % of measuring range end value 1) /10 K Start-up time < 1.5 hours Analog outputs 2 outputs: 0/4... 20 ma potential-free, load resistance: 500 Ω maximum Auxiliary gases Calibration gas Depending on the measuring task, approximately 80 % hydrocarbon concentration of the measuring range used relative to the propane equivalent in synthetic air Pressure: 3,000 hpa 2), consumption 2) : approx. 3 l/min (only during the calibration process) Instrument air From compressed air lines with a residual hydrocarbon content < 1 % measuring range, max. 4 ppm, without variations, free of condensate. (Dew point at least 10 C under the lowest possible outside temperature to avoid condensation in lines.) Pressure: Min. 4,000 hpa ±500 hpa, consumption 2) : min. 6 l/min, max. 17 l/min Fuel gas Pure hydrogen H 2 or H 2 /He 5.0 or better; residual hydrocarbon content < 0.5 ppm Pressure: 3,000 hpa; consumption: continuously approx. 1.8 l/h H 2 or 3.5 l/h H 2 /He Auxiliary gas connections Clamping ring screw connection for 6 mm pipes Power supply 230 V AC/48... 63 Hz or 115 V AC/48... 63 Hz; Power inputs: Approx. 330 VA during start-up, 280 VA during continuous operation 1) Measuring range limit value = 10 ppm C 3 2) Depending on equipment fitted 3) Under field conditions SICK EurOFID 7

8009777/2009-08 DIV03 Printed in Germany Subject to change without notice SICK MAIHAK GmbH Nimburger Straße 11 79276 Reute Germany Phone +49 7641 469-0 Fax +49 7641 469-1149 E-Mail: info.pa@sick.de www.sick.com Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com Handed over by: Our Competence in the Business Segments Factory automation With its intelligent sensors, safety systems, and auto ident applications, SICK realizes comprehensive solutions for factory automation. Logistics automation Sensors made by SICK form the basis for automating material flows and the optimization of sorting and warehousing processes. Process automation Optimized system solutions from SICK ensure efficient acquisition of environmental and process data in many industrial processes. Non-contact detecting, counting, classifying, and positioning of any types of object Accident protection and personal safety using sensors, as well as safety software and services Automated identification with bar code and RFID reading devices for the purpose of sorting and target control in industrial material flow Detecting volume, position, and contours of objects and surroundings with laser measurement systems Precise measurement of gases, liquids and dust concentrations for continuous monitoring of emissions and the acquisition of process data in production processes Gas flow measurements with maximum accuracy thanks to compact gas meters SICK MAIHAK GmbH Reute Germany www.sick.com