ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

Similar documents
GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

PRODUCT SHEET. Order probe only as RXPROBE02

Radnoti Liver Perfusion System

DISSOLVED OXYGEN SENSOR BT34i

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

SS32L Dissolved O 2 Probe

LogIT Dissolved Oxygen Probe

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

Aerobic Respiration. Evaluation copy

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Dissolved Oxygen Meter. ino2. Instruction Manual. Serial No..

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

12mm Dissolved Oxygen Sensor Care and Use Instructions

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Oxygen Sensor with Electrode

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

NEULOG OXYGEN LOGGER SENSOR GUIDE

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

iworx Sample Lab Experiment HE-4: Respiratory Exchange Ratio (RER)

Fish Respiration and Q 10

O 6 = 6 CO H 2 O H 2 = 16 CO 2. consumed during the oxidation of fatty acids, a ratio of 0.7.

SOLUBILITY OF A SOLID IN WATER

SOLUBILITY OF A SOLID IN WATER

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Experiment HE-9: Resting, Active, and Exercising Metabolic Rates

Instruction Manual DO 6. Economy Hand-held Dissolved Oxygen Meter. 68X Rev 2 Apr 08. Technology Made Easy... Part of Thermo Fisher Scientific

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

STERILIZABLE DISSOLVED OXYGEN SENSORS

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

QUICK START GUIDE TO DRINKING WATER MONITORING

PRECISION DISSOLVED OXYGEN MEASUREMENT SYSTEMS

Instruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s

Columbus Instruments

HI 9143, HI 9143M HI 9145

Experiment HS-2: Breathing and Gravity

Resting, Active, and Exercising Metabolic Rates

Experiment C-6 Gas Solubility

Dissolved Oxygen Sensor

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

A LAZAR LABORATORIES HANDBOOK DISSOLVED OXYGEN PRIMER

OXYGEN CONSUMPTION AND TEMPERATURE IN THE AQUATIC ENVIRONMENT

LABORATORY INVESTIGATION

Biology Unit 2, Structure of Life, Lab Activity 2-3

OxyProbe II Instruction Manual

Dissolved Oxygen Guide

Recording established using the VO2 and RER graph template file (h19.gtl)

Respiration. Exercise 1A: Breathing in Resting Volunteers Aim: To measure breathing parameters in a resting individual.

Dissolved Oxygen Probe (Order Code DO-BTA)

Free Chlorine Sensor For additional information, please visit our website at

Dissolved Oxygen/Temp Waterproof Tester

Chlorolab 3+ Liquid-phase oxygen electrode system for advanced photosynthesis & respiration studies

1. Photosynthesis and Light. See real-time evidence that light causes photosynthesis to occur!

OXYGEN CONSUMPTION AND TEMPERATURE IN THE AQUATIC ENVIRONMENT

Dissolved Oxygen Probe (Order Code DO-BTA)

Bioreactors Prof G. K. Suraishkumar Department of Biotechnology Indian Institute of Technology, Madras. Lecture - 15 Bioreactor env.par.

APBiology Unit 2, Chapter 8

Experiment B-3 Respiration

Cardiovascular and respiratory adjustments to exercise

BIL 151 Laboratory Enzymes: Practicing the Protocol

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Biology 347 General Physiology Lab Basic Pulmonary Functions: Respirometry and Factors that Effect Respiration

Chlorolab 2+ Liquid-phase oxygen electrode system for advanced photosynthesis & respiration studies

Vinmetrica Dissolved Oxygen System User Manual

Heavy Duty Dissolved Oxygen Meter

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor

BAUSCH & LOMB ENGINEERING ROCHESTER. Title: Membrane Press Procedure Page 1 of 14

Biology 347 General Physiology Lab Human Diving Response

Instruction Manual DO 6+ Dissolved Oxygen/Temp

MODEL GT820 OXYGEN SENSOR

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

Vapor Pressure of Liquids

PRO20 USER MANUAL. English. Français. Español. Deutsch

Vernier Optical DO Probe (Order Code ODO-BTA)

What is photosynthesis? Photosynthesis II: Dissolved O2

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Instruction Manual. DO 700 Dissolved Oxygen/ºC/ºF Bench Meter. Technology Made Easy...

Optical Dissolved Oxygen Meter

Visit us at Code

Digital Model 10 and Model 20 Controller

Instruction Manual. Multiparameter Benchtop Meter

Determination of the Gas-Law Constant (R) using CO2

T02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP

User Manual DOCUMENT # Pro20 Pro20i USER MANUAL. English

Unisense In Situ UniAmp Connector System

Micro600DO_ZI INST /1/17 13:16 Page 1. Palintest. Micro 600 DO Meter. Palintest ZI INST 1240

AP Biology 12 Cellular Respiration Lab

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

SensoDirect Oxi200 Dissolved Oxygen Meter Operating instructions

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

RM-80 respiration monitor

Transcription:

Technical Note ISE-730 and DO2-100 Overview In 1954, Dr. Leland Clark invented the first membrane-covered electrode designed to measure the concentration of oxygen in blood, or solution. This electrode was innovative because it was the first electrode to have both the anode and the cathode under the same nonconductive polyethylene membrane. The limited permeability of the membrane reduced the amount of oxygen depleted from the sample which permitted accurate quantitative measurements of the oxygen concentration to be made. Dr. Clark's electrode was the prototype for many of the biosensors used today, including the sensors used in blood gas analyzers and probes, like the iworx ISE-730, used in teaching and research laboratories. LabScribe is a trademark of 2015 How They Work The ISE-730 Oxygen Electrode has a Teflon membrane that permits a limited amount of oxygen to diffuse from the solution being measured to the electrolyte solution that covers the platinum cathode and silver anode of the electrode. The ISE-730 is supplied with a polarizing voltage of -0.80V from the DO2-100 Currentto-Voltage adapter. The polarizing voltage creates a flow of electrons, or current, between the platinum and silver elements of the electrode. The amount of current that flows between the anode and the cathode is proportional to the concentration of oxygen in the electrolyte that bathes these two electrodes, which is proportional to the concentration of oxygen in solution. In addition to providing a polarizing voltage for the oxygen probe, the DO2-100 converts the current output of the oxygen probe to a voltage output that can be recorded. The DO2-100 also amplifies this output voltage to a level that is easily recorded by a data acquisition unit. The output of the DO2-100 is 10 millivolts for every nanoampere of current that is flowing. If a two-point calibration is performed using room temperature deionized water, saturated with oxygen, and then

deoxygenated water at the same temperature, the voltage output of the DO2-100 adapter can be related to the oxygen concentration in the chamber. How to Use the ISE-730 Oxygen Electrode Equipment Setup 1) Plug the DIN8 cable into a DIN8 transducer input of an iworx data acquisition unit or amplifier. 2) Attach the cable of the oxygen electrode to the BNC connector on the DO2-100 Current-to-Voltage adapter. 3) Place the electrode in the reaction chamber or a beaker of the solution to be measured. Calibration of the ISE-730 Oxygen Electrode 1) Place a magnetic stir bar in a beaker and fill the beaker with with fresh deionized water before proceeding with the calibration procedure. 2) Place the electrode in the beaker and turn up the speed of the stir bar to the maximum rate that allows the stir bar to rotate evenly. If the solution in the chamber is stirred, changes in oxygen concentration reach the electrode instantaneously. If a stirrer is not used, changes in the rate of oxygen production are limited by the rate of diffusion. 3) Begin recording the output of the oxygen electrode. Note on the recording that the measurement is from water saturated with oxygen at room temperature. Note the room temperature. 4) When the trace settles down to steady baseline, record for an additional 10 seconds before going to the next step. 5) Replace the water in the beaker with a 0% oxygen solution, or club soda from a freshly opened container. Do not stir the liquid. Place the electrode in the liquid and immediately record the oxygen concentration in the chamber until the trace is a flat line at a lower amplitude. Note that this is the recording for a liquid depleted of oxygen at room temperature. 6) Stop the recording. 7) Determine the temperature ( C) and the barometric pressure in the lab. The oxygen concentrations in deionized water, over a short range of temperatures at 760mmHg, have been calculated and listed in Table 1. The absorption coefficients of oxygen and the vapor pressures of water at these temperatures are also listed.

8) The concentration of oxygen dissolved in deionized water, or its solubility (S), can be determined more accurately by using the following equation: S = (a/22.414) ((P-p)/P) (r%/100) where a is the absorption coefficient of O2 at temperature, p is the vapor pressure of water at temperature, P is the barometric pressure, and r% is the percent oxygen in the air. At 26 C and 760mmHg, assuming the concentration of oxygen in air is 21%, S = 252µMO2: (0.02783/22.414L/mole) ((760-25.09mmHg)/760mmHg) (21/100) = 252µMO2 Units Conversion 1) Scroll to the beginning of the calibration data. 2) Use the Display Time icons to adjust the Display Time of the Main window to show the complete calibration data on the same window. 3) Click the 2-Cursor icon on the LabScribe toolbar so that two blue cursors appear on the Main window. 4) Place Cursor 1 on the section of data collected when the ISE-730 was in the solution of oxygen-saturated deionized water, and Cursor 2 on the section of data collected when the electrode was in the oxygen-depleted water. 5) Open the channel menu by clicking on the down arrow to the left of the channel's title. Select Units from this menu and Simple from the submenu to open the Simple Units Conversion dialog. 6) In the Simple Units Conversion dialog window, make sure 2 point cal is selected in the pull-down menu in the upper left corner of the window. Put check marks in the boxes next to Apply Units to new data and Apply Units to all blocks. 7) Notice that the voltages from the two conditions are automatically entered into the value equations. Enter the values for the two oxygen concentrations in the calibration recording in the corresponding boxes on the right side of the conversion equations. For Cursor 1, enter the saturated oxygen concentration taken from Table 1 or derived from the calculation. For Cursor 2, enter zero. 8) Enter the name of the units, μm, in the box below the values. 9) Click on the OK button to activate the units conversion. 10) Select Save in the File menu and type a name for the file.

Table 1: Oxygen Concentration [O2] in Air-Saturated Deionized Water at 760mmHg H2O Vapor Temperature ( C) O2 Absorbance Coefficient (a) Water Vapor Pressure (p) (mmhg) 20 0.03102 17.54 284 21 0.03044 18.65 278 22 0.02988 19.83 273 23 0.02934 21.07 267 24 0.02881 22.38 262 25 0.02831 23.76 257 26 0.02783 25.09 252 27 0.02736 26.74 247 28 0.02691 28.35 243 29 0.02649 30.04 238 [O2] (μm) Experiments LabScribe experiments using the ISE-730 Oxygen Electrode and the DO2-100 Current-to-Voltage include: Experiment CM-3: Mitochondrial Respiration (found in the Cellular Metabolism category of the LabScribe Settings menu as Mitorespiration) Experiment CM-5: Carbon Dioxide Fixation in Intact Cells (found in the Cellular Metabolism category of the LabScribe Settings menu as CO2Fixation) Experiment CM-1: Oxygen Consumption and Size (found in the Cellular Metabolism category of the LabScribe Settings menu as O2Consumption- Size) Experiment CM-4: Photosynthesis in Isolated Thylakoids (found in the Cellular Metabolism category of the LabScribe Settings menu as Photosynthesis) Experiment CM-7: Oxygen Consumption and Aerobic Respiration in Goldfish (found in the Cellular Metabolism category of the LabScribe Settings menu as O2Consumption-AerobicResp) Experiment GB-3: Water Quality (found in the General Biology-Ecology category of the LabScribe Settings menu as WaterQuality) Care and Maintenance of the ISE-730 Micro-electrode Assembly and Preparation 1) Unscrew the acrylic housing with the affixed Teflon membrane from the oxygen electrode. 2) Check the level of electrolyte solution in this housing. The minimum height of electrolyte in the housing should be 6 mm.

3) If solution needs to be added to the housing, attach a filling tip to the bottle of electrolyte and fill the housing to the minimum height. To fill the housing without adding bubbles, gently place the bubble-free end of the filling tip against the inside of the Teflon membrane and add electrolyte until its level reaches the minimum height. 4) Insert the electrode tip into the housing. Be careful not to trap any air bubbles near the electrode tip. Screw the housing onto the body of the electrode until it stops. 5) Check the tip of the electrode for proper seating within the housing. If the electrode protrudes slightly beyond the end of the housing, it is seated correctly. Handling When necessary, the membrane of the electrode can be replaced by following the assembly and preparation procedure above. Note: When removing and replacing a membrane as well as when calibrating or making measurements, be careful not to apply pressure against the internal electrode. Any excessive pressure against the internal electrode can cause the electrode to crack rendering it useless and unrepairable. Cleaning When using the electrode in solutions containing protein, the electrode should be soaked in an enzyme cleaning solution after each use for a couple of minutes to remove the protein from the membrane surface. This will prolong the useful life of the membrane. Storing Always clean and rinse the electrode before storing. For long-term storage over 1 month: Remove the membrane housing from the electrode. Rinse the internal electrode with distilled water and pat dry. Place a new, unfilled membrane housing over the internal electrode and attach loosely (do not seat completely). This membrane will serve to keep the dust off of the electrode tip. For short-term storage, the electrode can be left in room air with the membrane housing still attached. Electrode Filling Solution (included) 95% Ethylene Glycol 268 mm NaHCO3 10mM KCl 62 Littleworth Road, Dover, New Hampshire 03820 (T) 800-234-1757 / 603-742-2492 (F) 603-742-2455