Chlorolab 2+ Liquid-phase oxygen electrode system for advanced photosynthesis & respiration studies

Similar documents
Chlorolab 3+ Liquid-phase oxygen electrode system for advanced photosynthesis & respiration studies

PRECISION DISSOLVED OXYGEN MEASUREMENT SYSTEMS

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

LogIT Dissolved Oxygen Probe

Optical Dissolved Oxygen Meter

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

BUYER S GUIDE AQUAlogger 530WTD

NEULOG OXYGEN LOGGER SENSOR GUIDE

Introduction The Smart Q Oxygen Adaptor enables an Oxygen electrode to be connected to an EasySense unit.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Columbus Instruments

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Optical Dissolved Oxygen Meter

DISSOLVED OXYGEN SENSOR BT34i

Heavy Duty Dissolved Oxygen Meter

Oxygen Measurement Systems High Reliability and Wide Application Coverage

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Pneumatic high-pressure controller Model CPC7000

PRODUCT SHEET. Order probe only as RXPROBE02

STERILIZABLE DISSOLVED OXYGEN SENSORS

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

HumiSys HF High Flow RH Generator

Digital Model 10 and Model 20 Controller

Series Environmental Chambers

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Complete Range of Force Tensiometers

Additel 761 Automated Pressure Calibrators Selection Guide

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

BUYER S GUIDE AQUAlogger 520

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Low gas volume & flow measurements made easier Gas Endeavour

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Pneumatic high-pressure controller Model CPC7000

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

Additel 761 Automated Pressure Calibrators

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

628 Differential Pressure Decay Leak Tester

FLUORESCENCE DETERMINATION OF OXYGEN

Specifications for the CMI 2409 Magnetocardiograph

RM-80 respiration monitor

MODEL GT820 OXYGEN SENSOR

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Pool and Spa. Water Testing

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Additel 761 Automated Pressure Calibrators

ADT 761 Automated Pressure Calibrator

High Pressure Chem-SCAN Operating Manual

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Oxygen Sensor with Electrode

The ultra compact photosynthesis system

Convergent Technologys product overview

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Code Basic module and level control complete with optionals code

12mm Dissolved Oxygen Sensor Care and Use Instructions

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

GasSense NDIR User Manual

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Tensiometer For the measurement of surface and interfacial tension

Additel 780 Series Pressure Controller

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Blood Parameter Monitoring System 550

Digital pressure gauges

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

When buying one of our prototypes you agree with this!

QUICK START GUIDE TO DRINKING WATER MONITORING

PHOENIX L300i Best-in-class Helium Leak Detectors

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

STARLOG. Capacitive Water Depth Probe

Solutions for transcutaneous monitoring

CMA4000 Specifications

Microwave Digestion System MWS-3 + Unique optical temperature and pressure monitoring of each individual sample during digestion.

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

PERME- OX2/230 Oxygen Transmission Rate test system

Hand-held pressure calibrator with integrated pump Model CPH6600

D-Opto Dissolved Oxygen Sensor Operation Manual

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Dissolved Oxygen Probe (Order Code DO-BTA)

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

The instrument will process the samples one by one till all the samples have been cleaned up.

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

InFlow Modular perfusion bioreactor

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Highest Quality. Gas Chlorination Systems

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Transcription:

Chlorolab 2+ Liquid-phase oxygen electrode system for advanced photosynthesis & respiration studies

Chlorolab 2+ Liquid-phase oxygen electrode system for advanced photosynthesis & respiration studies > > PC operated USB Oxylab+ electrode control unit > > DW2/2 advanced electrode chamber with 4 optical ports and integral S1 oxygen electrode disc > > LED1/W white LED light source (up to 2,000 µmols m -2 s -1 ) with automated control via user-defined PFD light tables > > Suitable for liquid-phase samples between 0.2-2.5ml (min. 1.5ml if illuminated) with 0 100% oxygen concentration > > 24 bit high resolution measurement of oxygen signals > > Integral systems for measurement of ph & other ionselective electrode (ISE) signals with 16 bit resolution > > Onboard LCD readings of oxygen, auxiliary & ISE signals > > 2 channel capability via purchase of additional systems > > Quantitherm PAR/Temp sensor for light source calibration > > OxyTrace+ Windows software for data acquisition, hardware control & data analysis > > Real time 0 4.5v analogue output of oxygen signal

Oxylab+ electrode control unit The next generation Oxylab+ oxygen electrode control unit combines striking aesthetics with enhanced features and functionality offering significant advances in flexibility and performance over previous generations of electrode control unit. As part of a complete system, Oxylab+ provides a convenient yet powerful tool for measurements of oxygen evolution or uptake across a broad range of liquid-phase samples from chloroplast extractions to mitochondrial suspensions with oxygen concentrations up to 100%. Oxylab+ offers unrivalled price vs. performance combining simplicity of operation with an enviable feature set. The outstanding flexibility ensures Oxylab+ is equally useful in both a teaching and research capacity. 24 bit resolution allows detection of minute changes in oxygen tension without needing to apply instrument gain. This results in beautiful, noise free traces even when zoomed close in on areas of interest. Integral electronics provide control over an LED light source with automatic intensity changes handled by user-defined PFD light tables in software. The system allows realtime graphing of signals from auxiliary inputs and ion-selective electrodes providing scope for comprehensive analysis of oxygen activity simultaneously with signals such as ph, TPP+, calcium, potassium and hydrogen ions. Signals from all inputs are additionally displayed on an LCD screen mounted within the front panel of the Oxylab+ control unit. Up to 2 individual Oxylab+ control units may be linked to a single PC and operated simultaneously from OxyTrace+ software providing a powerful, multi-channel system. Oxygen electrode disc Membrane - - - - - - Cathode (Pt) + 2H 2 O + 2e - H 2 + 2OH - H 2 + 2e - 2OH - - + 4e - 0.6-0.7v KCl bridge KCl electrolyte in disc well + + + + + + Anode (Ag) 4Ag 4Ag + + 4e - 4Ag + + 4Cl - 4AgCl Since its original design in the early 1970 s by Tom Delieu and David Walker, the S1 Clark Type Oxygen Electrode disc remains largely unchanged a true testament to the quality and reliability of the sensor. The S1 consists of a platinum cathode and silver anode set into an epoxy resin disc and is prepared for use by trapping a layer of 50% saturated KCl solution beneath an oxygen permeable PTFE membrane. A paper spacer placed beneath the membrane acts as a wick to provide a uniform layer of electrolyte between anode and cathode. When a small voltage is applied across these electrodes (with the platinum negative with respect to the silver), the current which flows is at first negligible and the platinum becomes polarised (i.e. it adopts the externally applied potential). As this potential is increased to 700 mv, oxygen is reduced at the platinum surface, initially to hydrogen peroxide H 2 so that the polarity tends to discharge as electrons are donated to oxygen (which acts as an electron acceptor). The current which then flows is stoichiometrically related to the oxygen consumed at the cathode providing a fast, effective method of detecting small changes in oxygen tension in a liquid-phase sample.

DW2/2 electrode chamber The DW2/2 electrode chamber has been developed specifically to allow simultaneous spectroscopic and oxygen flux measurements. The reaction vessel of the DW2/2 is constructed from precision bore borosilicate glass tube with a prepared S1 electrode disc forming the floor of the vessel. Precision temperature control of sample and sensor is delivered via a concentric water jacket with suitable connection ports for a thermoregulated circulating water bath. The water jacket is constructed from black acetal which provides the ability for dark adaptation of samples or oxygen measurement in complete darkness. There are four optical ports mounted perpendicular to the reaction vessel at right angles to one another. The LED1 LED light source supplied with the Chlorolab 2+ system fits directly into any of these ports for uniform and high intensity illumination of the sample. Other light sources, fibre optic light guides and detectors may also be mounted on the DW2/2 via the ports enabling spectroscopic measurements to be made. DW2/2 is fitted with a plunger with a capped central bore. The height of the plunger may be adjusted easily to suit liquid-phase sample volumes of between 0.2-2.5ml whilst the central bore easily accommodates Hamilton type syringes allowing additions/subtractions to/from the reaction vessel during an experiment. LED1 light source A LED1 high intensity light source in one of three colours is supplied with the Chlorolab 2+ system. The different light sources that can be supplied are as follows: Spectral power distribution LED1/R LED1/B LED1/W 400 450 500 550 600 650 700 750 800 Wavelength (nm) LED1/R: red LED with a peak wavelength of 627nm LED1/B: blue LED with a peak wavelength of 470nm LED1/W: white LED with a colour temperature of 4100K Light intensity adjustments are made automatically based on userdefined PFD tables within OxyTrace+ software. PFD tables consist of up to 20 individual steps allowing complex light response assays to be configured for automatic execution during a measurement. Each of the LED1 light sources provide a maximum intensity of up to 2,000 µmol m -2 s -1 in DW2/2. Greater intensities are achievable by purchasing additional LED1 housings and an adapter which allows simultaneous automatic control of up to 3 LED1 light units.

Quantitherm PAR/temperature sensor The QRT1 consists of a handheld display unit combined with the QTP1+ probe sensor. For use as a calibration tool for the LED1 light source, the QTP1+ probe connects directly to the rear of the Oxylab+ control unit allowing a 10 step multi-intensity calibration routine within the OxyTrace+ software to be performed. QRT1 may also be operated as a standalone sensor across the range of normal measuring temperatures used for both photosynthesis and cellular respiration studies and offers maximum accuracy in the 10 C 40 C region. For photosynthesis measurements, the PAR quantum sensor provides a displayed resolution of 1µmol m -2 s -1 throughout the 0 to 5,000 µmol m -2 s -1 range and up to a maximum of 50,000 µmol m -2 s -1 with a displayed resolution of 10 µmol m -2 s -1. OxyTrace+ software OxyTrace+ is a multi-function Windows program supplied with Chlorolab 2+ for system configuration, calibration, data acquisition and analysis. An automated 2 step calibration routine guides the user quickly and effectively through the system calibration process using electrode values measured from air-saturated and deoxygenated water. OxyTrace+ allows simple configuration of comprehensive PFD tables consisting of up to 20 individual light steps. Light intensity adjustments are performed automatically during the measurement. OxyTrace+ also allows calibration of the LED1 light source from a simple software routine. This requires the QTP1 PAR/temperature sensor to be connected to the rear of the Oxylab+ control unit and placed into the reaction vessel prior to the addition of any liquids. A tabbed interface allows a simple transition between the different data views including oxygen electrode (and if configured, auxiliary and external ion-selective electrode) real-time output, a split screen showing real-time rate of change above the oxygen signal and tabulated numerical data. Post acquisition analysis tools allow automatic calculation of oxygen rates from user-defined rate intervals. Additional analysis tools automatically calculate rates of change for defined PFD light steps with a calculation of quantum yield presented at the end of a measurement. All files are saved as Comma Separated Values (CSV) data files opening effortlessly in external data processing packages such as MS Excel. OxyTrace+ will run on all supported Microsoft operating systems. System components Chlorolab 2+ systems are supplied with the following components: OXYL1+: Oxylab+ electrode control unit DW2/2: Oxygen electrode chamber S1: Oxygen electrode disc and SMB-SMB connection cable LED1: LED light housing in choice of 3 colours: LED1/W: white LED (4100K - default option) LED1/R: red LED (627nm) LED1/B: blue LED (470nm) QRT1: Quantitherm PAR/temperature sensor A2: Membrane applicator to assist with smooth application of electrode membrane S2/P: Pack of 5 magnetic followers S3: Pack of 2 replacement borosilicate glass reaction vessels S4: PTFE membrane (0.0125mm x 25mm x 33m) S6B: Set of replacement o-rings for DW2/2 electrode chamber S16: Cleaning kit for the S1 electrode disc.

Technical specifications Oxylab+ electrode control unit Measuring range: Signal inputs: Resolution: Polarising voltage: Input sensitivity: Magnetic stirrer: Sampling rate: Electronics: Display: Communications: Analogue output: Dimensions (HWD): Power: DW2/2 electrode chamber Suitability: Construction: Sample chamber: Sample volume: Plunger: Temperature control: Optical ports: Dimensions: Oxygen: 0-100%, ph: 0-14pH, Aux: 0-4.096V S1 electrode (SMB), ph/ise (BNC), Aux (8 pin Mini Din), QTP1 PAR/Temp probe (6 pin Mini Din) Oxygen: 0.0003% (24 bit), ph: 0.0006pH (16 bit), Aux: 62.5µV/bit (16 bit) 700mV 0-9000nA Software controlled 150-900rpm in % steps 0.1-10 readings/s Microcontroller: 16 bit high performance CPU running at 32 MHz ADC: Dual, Low power, 16/24 Bit Sigma Delta 61 x 2 character blue LCD USB2.0 0-4.5V signal 250 x 125 x 65mm - 0.63 Kg 95-260V universal input mains supply. Output 12V DC 2.5A Liquid-phase photosynthesis/ respiration Black acetal Precision bore, borosilicate glass tube 0.2-2.5ml (1.5ml min. for illumination) Variable height, capped central bore Water jacket connected to circulating water bath 4 x optical port with 16mm diameter 105 x 65mm - 0.4Kg S1 oxygen electrode disc Electrode type: Clark type polarographic sensor Electrode output: Typically 1.6µA at 21% Residual current: Typically 0.04µA in 0% Response time: 10-90% typically < 5 seconds Oxygen consumption: Typically <0.015µmol/hr -1 LED1 light source Light source: Control: Wavelength: Cooling: Intensity: Dimensions: Single LED Via Oxylab+ & OxyTrace+ software LED1/W - 4100K (colour temperature) LED1/R - 627nm peak wavelength LED1/B - 470nm peak wavelength Integral automatic cooling fan 2,000 µmols m -2 s -1 (greater intensities possible with multiple LED1 units) 64 (dia) x 60 mm (h) - 270g QRT1 PAR/Temperature sensor Measuring range: 0-50000μmol m -2 s -1 (+/- 5%) in 2 ranges (0-5000 & 0-50000) in 400-700nm band Resolution: 1µmol m -2 s -1 at 0-5000 PAR sensor: Temperature sensor: Signal display: Power requirements: Dimensions (display): Dimensions (QTP1): 10μmol m -2 s -1 at 5001-50000 Silicon photodiode & optical filter with white acetal diffuser RT curve matched bead thermistor. 0-50 C/32-122 F (0.02 C resolution) Handheld display unit. 16 x 2 LCD display. 0-5V analogue output of PAR/ temperature values 4 x 1.5V AA (LR6) cells Typically 100 hours battery life 146 x 92 x 32mm - 300g 9.5 x 107mm - 50g Hansatech Instruments is a British company that has been developing high quality scientific instrumentation for over 40 years. Our systems are used widely for teaching & research in cellular respiration & photosynthesis programs in more than 100 countries throughout the world. We have gained an enviable reputation for quality, reliability & excellent price/performance. Our product range consists of a range of modular solutions for the measurement of oxygen using Clark type polarographic sensors. We also develop chlorophyll fluorescence measurement systems using both continuous excitation & pulse-modulated measurement techniques with further optical instrumentation for the measurement of sample chlorophyll content. Purchasers of Hansatech Instruments products can be assured of ongoing support & prompt & efficient attention to enquiries at all times. Support is available both directly & from our global distributor network. Customers are encouraged to register their instruments on our website which allows access to our Support Ticketing System in addition to instruments manuals & software upgrades. Hansatech Instruments Ltd Narborough Road, Pentney, King s Lynn, Norfolk PE32 1JL, UK Tel: +44 (0)1760 338877 Fax: +44 (0)1760 337303 info@hansatech-instruments.com www.hansatech-instruments.com