DEFINING SETPOINT PARAMETERS PARAMETER DESCRIPTION ID OUTPUT CHANGE Setpoint (Target) Weight value desired at end of weighing operation. SP WT > or =

Similar documents
Application Notes. SLP85xD Load Cells

Manual Weighingblock VB2 series and Uniscale

C1960. Multi-recipe profile recorder/controller. Measurement made easy

Hydro-Control V User Guide

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

MONSOON 6V Pump Control System

Scoreboard Operator s Instructions MPC Control

CP3R Quick Start Manual

CPN1 Quick Start Manual

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

StockWeigh 500 D3632 US-B

Touch Screen Guide. OG-1500 and OG Part # T011

OPERATING INSTRUCTIONS FOR

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Ultima. X Series Gas Monitor

Standard Chiller 1/4 compressors Manual version: /10/96

March Asher Operation

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Plasma Asher: March PX-500 User guide (May-30, 2017)

Monsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.

FCO750 LEAK DETECTOR

AX5000 Operational Manual

STANDARD OPERATING PROCEDURE

OPERATING INSTRUCTIONS FOR

Position Controller PS312P_LCD_v2.2

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Standard 1/4 compressor chiller/heat pump with heating recovery Manual version: /02/97

SR-242 USER S GUIDE. Table of Contents

MICRO BASED CONTROL SYSTEM YLCS-SA/HA/AA YAES-SA 2 System YAES-SA 3 System YAES-DSA 4 System

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

DTM 60, DTM60A, DTM 60EL, DT 100, DT 483, DT 483A STOPWATCH OPERATING INSTRUSTIONS

INSTRUCTION MANUAL STATION CONTROLLER SC100 MOTOR PROTECTION ELECTRONICS, INC.

Altimeter and Compass Watch Instruction Manual

OMNISPORT 2000 SWIMMING QUICK REFERENCE

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

Operating instructions Electrical switching facility pco

ACV-10 Automatic Control Valve

WATER CONTROL SYSTEM QUICK START

A4s Operation Manual

Single Pressure/ vacuum decay leak rate, loss, rate of loss, or occlusion tests with standard Cv valves.

Design Envelope Booster. Sequence of operation

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Roller AC Servo System

2. USER INSTRUCTION. Table of contents: Pg.1/14 N:\FAP-2000: LWP

MP-70/50 Series Scoreboard Controller User Guide

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

KEM Scientific, Inc. Instruments for Science from Scientists

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.

MACON R70 FOR 1 OR 2 COMPRESSORS

FRDS GEN II SIMULATOR WORKBOOK

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

User manual CF8-D/W-IN

Series Environmental Chambers

ALGE Water Polo Scoreboard

Controlling the prefeeder

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

M2110P SMART PRESSURE GAUGE USER S MANUAL

E L E V E N C R O Z E R V I L L E R D. A S T O N, P A WEIGH SCALE BLENDER with "FOUR" COMPONENT SOFTWARE SEPTEMBER 26, 2013

Gravimetric Blenders

Rcvr-Acct#: Date: May 3, :31 AM

( ) ( ) *( A ) APPLICATION DATA. Procidia Control Solutions Coarse/Fine Control. Split-Range Control. AD Rev 2 April 2012

Valve Communication Solutions Axiom

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

FCO770 LEAK DETECTOR

STX 165 Operation. Data Knob Enter Pushbutton. Power/Mode Control. Select Knob Ident Pushbutton. VFR Pushbutton

GBA-800. NEW G-SQUAD Sports Line G-SQUAD. Technology & Design Guide. A smartphone-linked model to help you with your daily workout

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

CHILLER CONTROL PANEL PROGRAMMING AND DATA ACCESS

AHE58/59 AC Servo System

Revision 1 AIR & WATER COOLED LIQUID CHILLERS MICRO BASED CONTROL SYSTEM WITH IPUII

APPLICATION NOTE E SQUEEZE DELAY AND RETRACTION OPERATION

Model 130M Pneumatic Controller

PTG100 Precision Test Gauge

CCT-7320/ROC-2313 Reverse Osmosis Controller

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

Digital Vacuum Regulator

DYNATROL REFERENCE INSTRUCTIONS With the 700 Series Processor

TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES

SIP 1000 OPERATION AND PROGRAMMING MANUAL

BT 2000 range Score / Club / Classic / Alpha

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

BUBBLER CONTROL SYSTEM

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

INSTRUCTION MANUAL PS4 SPS-X3 VER 2.0

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

MICROPROCESSOR CONTROLLED DUAL BEAM NDIR ANALYSER MODELS 414/5/6/7

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Auriol LCD sports watch with altimeter and compass

Instructions and Advices to use the electronic controller Logik 31-S

Proto Matrix Musashi 3 Upgrade Manual

INSTALLATION,OPERATION AND MAINTENANCE INSTRUCTIONS DRY AIR COOLER

Transcription:

(SEL.OP2) SETPOINT CONFIGURATION The 7600E Digital Weight Indicator is available with four (4) control inputs and four (4) control outputs when equipped with the optional Digital Input/Output (DIO) module. Setpoint outputs can be configured in the following modes: Four independent setpoints with pre-act. (V3.98.0 and later) Two Setpoints and zero band. Two Setpoints, with pre-act, and zero band. Two Setpoints, with dribble control. Two Setpoints, with pre-act and dribble control. One setpoint with pre-act, dribble control, tolerance and Zero Band output. "HI - LO" Alarm Control. "OVER/UNDER" Check Weigh Control. Setpoints can be used in a straight setpoint system or as part of either a "Manual Batching" or "Automatic Batching" system. When configured for batching, the setpoints are de-energized except when the batch is in process. When setpoint cutoff is reached, the setpoints are latched OFF and will not reactivate until the next batching sequence. A "Zero Band" (ZBD), around GROSS ZERO is available for monitoring an "empty scale" - in certain setpoint configurations. Rev 0 1

DEFINING SETPOINT PARAMETERS PARAMETER DESCRIPTION ID OUTPUT CHANGE Setpoint (Target) Weight value desired at end of weighing operation. SP WT > or = SP Pre-act Weight value which is set to allow for material in suspension Pr WT > or = SP - Pr Dribble Weight value at which material flow changes, usually from "fast" to "slow" feed. dr WT > or = SP-(dr)-Pr Tolerance Band Weight band around setpoint HI,Lo trg -LO > WT > trg +HI Zero Band Weight band (±) around GROSS ZERO used to define "empty scale". ZBD 0 - x > WT > 0 + x NOTES: 1. Front panel LED's for setpoints 1 and 2 are ON when respective outputs are ON. 2. In Batching modes (BAT1 & BAT2) the setpoint outputs are latched while running. 2

PARAMETER SEL.OP2 (SETPOINT OPERATION) GROSS NET TARE RECALL PARAMETER SELECTION 2.0 OFF SUBPARAMETER DATA SELECTION OFF SP ou bat1 bat2 DEFINITION Setpoints "Off". Zero Band (Parameter "10") is still functional Setpoint mode Over/Under (Check weighing mode) Manual Batch mode, pauses between setpoints Automatic Batch mode, continues without pause between setpoints (2.0 SP) SETPOINT OPERATION (Straight Setpoints) 2.2 OFF Setpoint 1 - "OFF" SI Setpoint 1 S1.P S1.d S1.P.d DUAL Setpoint 1 with Pre-Act Setpoint 1 with Dribble Setpoint 1 with Pre-Act and Dribble Setpoint 1a, 1b Two/four independent setpoints with Pre-Act 2.3 Gr net dsp Setpoint1 tracks GROSS weight only NET weight only Displayed weight 2.4 POS Setpoint 1 is OFF when weight < SP. zer Setpoint 1 is ON when weight < SP. 2.6 OFF Setpoint 2 - "OFF" S2 Setpoint 2 S2.P S2.d S2.P.d DUAL tol Setpoint 2 with Pre-Act Setpoint 2 with Dribble Setpoint 2 with Pre-Act and Dribble Setpoint 2a, 2b Two/four independent setpoints with Pre-Act Tolerance for Setpoint 1 2.7 Gr net dsp Setpoint2 tracks GROSS weight only NET weight only Displayed weight 2.8 POS Setpoint 2 is OFF when weight < SP value zer Setpoint 2 is ON when weight < SP value 2.10 Zbo Zero band value (insert weight value) 2.11 Off Hysteresis, Provides 3 grads to prevent relay chatter s.p.d (i.e) On SP1.trG (1000) SP1.PrE (5) SP1.drb (10) Main and Fast Feed are on until weight reaches 990 (1000-10), then Fast Feed turns off and Main stays on until pre-act at 995. (1000-5) 3

PARAMETER SEL.OP2 (SETPOINT OPERATION) GROSS NET TARE RECALL PARAMETER SELECTION SUBPARAMETER DATA SELECTION DEFINITION (2.0 ou.un) SETPOINT OPERATION (Over/Under) 2.2 OFF Setpoint - "OFF" HL Hi/Lo band tgt Ck1 Ck2 Ck3 Target with +/- band Check Weigher 1 Check Weigher 2 Check Weigher 3 2.3 Gr net dsp Setpoint tracks GROSS weight only NET weight only Displayed weight 2.4 POS Setpoint 1 is OFF when Lo zer Setpoint 1 is ON when Lo 2.5 POS Setpoint 1 is OFF when Accept zer Setpoint 1 is ON when Accept 2.6 POS Setpoint 1 is OFF when Hi zer Setpoint 1 is ON when Hi 2.10 Zbo Zero band value (insert weight value) 2.11 Off Hysteresis, Provides 3 grads to prevent relay chatter On 2.12 Off On Enables Bar Graph Legends HL Lo (950) Lo is ON until weight reaches 950, then Accept is ON until 1050, (i.e) tgt (i.e) Hi (1050) Target (1000) Lo (50) Hi (50) Ck1 Target (1000) Accept (10) OofB (50) Ck2 Target (1000) Accept (10) OofB (50) Ck3 Target (1000) Accept (10) and Hi is ON above 1050 (2.4-2.6 = POS) Lo is ON until weight reaches 950, then Accept is ON until 1050, and Hi is ON above 1050 (2.4-2.6 = POS) Target with Accept and Out of Bounds setpoints. Bar graph 1. Target output is ON with weight within target range, Accept ON within acceptable range, OoB ON when outside acceptable range. Target with Accept and Out of Bounds setpoints. Bar graph 2. Target output is ON with weight within target range, Accept ON within acceptable range, OoB ON when outside acceptable range. Target with Accept setpoint. Bar graph 3. Target output is ON with weight within target range, Accept ON outside of acceptable range. 4

PARAMETER SEL.OP2 (SETPOINT OPERATION) GROSS NET TARE RECALL (2.0 Bat1) SETPOINT OPERATION (Manual Batch) 2.2 OFF Setpoint 1 - "OFF" SI Setpoint 1 S1.P S1.d S1.P.d DUAL Setpoint 1 with Pre-Act Setpoint 1 with Dribble Setpoint 1 with Pre-Act and Dribble Setpoint 1a, 1b Two/Four independent setpoints with Pre-Act 2.3 Gr net dsp Setpoint1 tracks GROSS weight only NET weight only Displayed weight 2.4 POS Setpoint 1 is OFF when weight < SP. zer Setpoint 1 is ON when weight < SP. 2.6 OFF Setpoint 2 - "OFF" S2 Setpoint 2 S2.P S2.d S2.P.d DUAL Setpoint 2 with Pre-Act Setpoint 2 with Dribble Setpoint 2 with Pre-Act and Dribble Setpoint 2a, 2b Two/Four independent setpoints with Pre-Act 2.7 Gr net dsp Setpoint2 tracks GROSS weight only NET weight only Displayed weight 2.8 POS Setpoint 2 is OFF when weight < SP value zer Setpoint 2 is ON when weight < SP value 2.10 Zbo Zero band value (insert weight value) 2.13 Off On Restart after power outage Off: Restart with Start key or remote Start input On: Restart with Start key AND yes to resume 5

PARAMETER SEL.OP2 (SETPOINT OPERATION) GROSS NET TARE RECALL (2.0 Bat2) SETPOINT OPERATION (Auto Batch) 2.2 OFF Setpoint 1 - "OFF" SI Setpoint 1 S1.P S1.d S1.P.d DUAL Setpoint 1 with Pre-Act Setpoint 1 with Dribble Setpoint 1 with Pre-Act and Dribble Setpoint 1a, 1b Two/Four independent setpoints with Pre-Act 2.3 Gr net dsp Setpoint1 tracks GROSS weight only NET weight only Displayed weight 2.4 POS Setpoint 1 is OFF when weight < SP. zer Setpoint 1 is ON when weight < SP. 2.5 1-10 sec Time delay before auto-print and continue Batch 2.6 OFF Setpoint 2 S2 Setpoint 2 S2.P S2.d S2.P.d DUAL Setpoint 2 with Pre-Act Setpoint 2 with Dribble Setpoint 2 with Pre-Act and Dribble Setpoint 2a, 2b Two/Four independent setpoints with Pre-Act 2.7 Gr net dsp Setpoint2 tracks GROSS weight only NET weight only Displayed weight 2.8 POS Setpoint 2 is OFF when weight < SP value zer Setpoint 2 is ON when weight < SP value 2.9 1-10 sec Time delay before auto-print and return to Normal weigh mode 2.10 Zbo Zero band value (insert weight value) 2.13 Off On Restart after power outage Off: Restart with Start key or remote Start input On: Restart with Start key AND yes to resume 6

FUNCTIONAL DESCRIPTION Four setpoint (DUAL) setpoint mode DUAL mode is the (four independent) setpoint operation mode, where cutoff occurs when the weight is greater than or equal to ( ) the setpoint value. B. The display alternates between the setpoint entry parameter (SP1-a) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad, push the ENT key to Save. D. Push the SET key. The display will step to the next selection (SP1-b,.SP2-a,SP2-b.) E. Push SET to exit. F. The setpoint values may be recalled at any time by pushing the SET key repeatedly. If Pre-acts are required for any of the DUAL setpoint outputs: A. Push the SET key and HOLD for 5 seconds. B. The display alternates between the setpoint entry parameter (SP1-a) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad, push the ENT key to Save. D. Push the SET key. The display will step to the next selection (SP1P-a, SP1-b,.SP1P-b, SP2-a, SP2P-a, SP2-b, SP2P-b.). SPx-y = target value, SPxP-y = pre-act value. E. Push SET to exit. 7

FUNCTIONAL DESCRIPTION Straight setpoint mode SP mode is the setpoint (SP) operation mode, where cutoff occurs when the weight is greater than or equal ( ) to the setpoint (SP). Zero Band output is available. B. The display alternates between the setpoint entry parameter (SP1-trg) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP2-trg.) E. Push SET to exit. F. The setpoint values may be recalled at any time by pushing the SET key repeatedly. G. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 8

FUNCTIONAL DESCRIPTION Pre-act mode PR adds a "pre-act" value which allows for "in-flight" material compensation. The cutoff occurs when the weight is greater than or equal to ( ) the setpoint (SP) value minus the pre-act (Pr) value. Note: This allows changes in setpoint values while maintaining the pre-act setting. Zero band output is available. B. The display alternates between the setpoint entry parameter (SP1-trg) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP1-PrE.) Enter the pre-act weight value for SP1 target value. Push the "ENT" key to Save. E. Push the SET key. Enter SP2-trg and SP2-PrE as above. F. Push SET to exit. G. The setpoint values may be recalled at any time by pushing the SET key repeatedly. H. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 9

FUNCTIONAL DESCRIPTION Dribble mode Dribble mode adds a "dribble" (dr) which provides a "two-speed" (fast feed, slow feed) cutoff to enhance accuracy. The basic setpoint is used for slow feed, while the additional cutoff (fast feed) occurs when the weight is greater than or equal to ( ) the setpoint minus the dribble value. Note: This allows changes to the setpoint target value while maintaining the same amount of fast to slow feed differential. Zero band output is not available if SP2 is used in (dr) mode.) B. The display alternates between the setpoint entry parameter (SP1-trg) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP1-drb.) Enter the Dribble Weight differential value for SP1 target value. Push the "ENT" key to Save. E. Push the SET key. Enter SP2-trg and SP2-drb as above. F. Push SET to exit. G. The setpoint values may be recalled at any time by pushing the SET key repeatedly. H. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. Not available if SP2 is set for (dr) dribble mode. 10

FUNCTIONAL DESCRIPTION Dribble mode with Pre-act Provides both a dribble (dr) and preact (Pr) to setpoint configuration. The slow feed cutoff occurs when the weight is greater than or equal to ( ) the setpoint minus the pre-act value. The fast feed cutoff occurs when the weight is greater than or equal to ( ) the setpoint minus the pre-act and minus the dribble value. Note: This allows changes in setpoint settings while maintaining the pre-act and dribble settings. Zero band output is not available if SP2 is used in (dr) mode. B. The display alternates between the setpoint entry parameter (SP1-trg) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP1-PrE.) Enter the pre-act weight value for SP1 target value. Push the "ENT" key to Save. E. Push the SET key. The display will step to the next selection (SP1-drb.) Enter the Dribble Weight differential value for SP1 target value. Push the "ENT" key to Save. F. Push the SET key. Enter SP2-trg, SP2-PrE, and SP2-drb as above. G. Push SET to exit. H. The setpoint values may be recalled at any time by pushing the SET key repeatedly. I. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. Not available if SP2 is set for (Dr) dribble mode. 11

FUNCTIONAL DESCRIPTION Over/Under Hi/Lo mode Provides High, Low, and Accept outputs with the Low level ON when the weight is less than (<) Lo setpoint (SP LO), the High level ON when the weight is greater (>) than Hi setpoint (SP HI), and Accept is ON in between. This is for applications where High and Low settings require direct changes. Zero band output is available. B. The display alternates between the setpoint entry parameter (SP-LO) and current setpoint value. C. Enter the desired LO setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP-HI.) E. Enter the desired HI setpoint value using the 0-9 keypad. Push the "ENT" key to Save. F. Push SET to exit. G. The setpoint values may be recalled at any time by pushing the SET key repeatedly. H. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 12

FUNCTIONAL DESCRIPTION Over/Under Target mode Provides High, Low, and Accept outputs the same as direct entry above, except that a direct entry is made only for a target weight and High/Low settings become dependent upon that weight. The Low level is ON when the weight is less than (<) the Target minus the (Lo) value. The High level is ON when the weight is greater than (>) the Target plus the (HI) value. Accept is ON in between. Zero band output is available. B. The display alternates between the setpoint entry parameter (SP-trG) and current setpoint value. C. Enter the desired Target setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP-LO.) E. Enter the desired LO differential setpoint value using the 0-9 keypad. Push the "ENT" key to Save F. Push the SET key. The display will step to the next selection (SP-HI.) G. Enter the desired HI differential setpoint value using the 0-9 keypad. Push the "ENT" key to Save. H. Push SET to exit. I. The setpoint values may be recalled at any time by pushing the SET key repeatedly. J. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 13

FUNCTIONAL DESCRIPTION Over/Under Ck1 Provide Check-Weigh outputs for Within Target Range, Within Acceptable Range, and Out of Bounds Range. Direct entry is made only for a Target value (Ck-cnt) while the Acceptable and Out of Bounds settings become dependent upon that weight. Function of the bar graph as follows: If weight is within acceptable (Target) range, Within Target bar graph segment is ON. If outside target range, but within Out of Bounds range, the Lo (Hi) Acceptable segment will be ON. If outside of the Out of Bounds range, both the Lo (Hi) Acceptable and Out segments will be ON. Zero band output is available. B. The display alternates between the setpoint entry parameter (Ck-Cnt) and current setpoint value. C. Enter the desired Target setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (ACCEPt.) E. Enter the desired setpoint value for the acceptable weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. F. Push the SET key. The display will step to the next selection (Out.bnd.) G. Enter the desired setpoint value for the out of bounds weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. H. Push SET to exit. I. The setpoint values may be recalled at any time by pushing the SET key repeatedly. J. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 14

FUNCTIONAL DESCRIPTION Over/Under Ck2 Same function as CK1 with the exception - Function of the bar graph as follows: Only one bar graph segment is ON at a time. Either Out LO, Accept LO, Within Target, Accept HI, Out HI. Zero band output is available. B. The display alternates between the setpoint entry parameter (Ck-Cnt) and current setpoint value. C. Enter the desired Target setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (ACCEPt.) E. Enter the desired setpoint value for the acceptable weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. F. Push the SET key. The display will step to the next selection (Out.bnd.) G. Enter the desired setpoint value for the out of bounds weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. H. Push SET to exit. I. The setpoint values may be recalled at any time by pushing the SET key repeatedly. J. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 15

FUNCTIONAL DESCRIPTION Over/Under Ck3 Provides Check-Weigh outputs for Within Acceptable Range, and Out of Bounds Range. Direct entry is made only for a Target value (Ck-cnt) while the Acceptable setting becomes dependent upon that weight. Function of the bar graph as follows: If weight is within acceptable range, Within Target bar graph segment is ON. If outside target range, both Lo and Lo-Lo (or High and High-High) bar graph segments are ON. Zero band output is available. B. The display alternates between the setpoint entry parameter (Ck-Cnt) and current setpoint value. C. Enter the desired Target setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (ACCEPt.) E. Enter the desired setpoint value for the acceptable weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. F. Push SET to exit. G. The setpoint values may be recalled at any time by pushing the SET key repeatedly. H. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 16

Bat1 - FUNCTIONAL OPERATION - "MANUAL BATCHING" MODE The "Manual Batching" Mode operates as follows: A. The START/STOP key is pushed. B. The "Setpoint" indicator LED turns "On". C. The unit automatically switches to the "NET" weighing mode. (If configured for NET batching.) D. An automatic "AUTO TARE" operation takes place. E. Ingredient 1 Setpoint (if enabled) is activated. All keys except CLEAR and START/STOP are locked out during Run. F. When the displayed weight reaches or exceeds the target value *, the output is deactivated. G. A Demand printout takes place. H. The unit enters a "Pause" mode. (During Pause the Tare key is functional.) PAUSE mode is indicated with a flashing P. I. When the START/STOP key is again pushed, Ingredient 2 output (if enabled) is activated. J. An automatic "AUTO TARE" operation takes place. K. When the displayed weight reaches or exceeds the Setpoint 2 target value *, the output is deactivated. L. A Demand printout takes place and the unit returns to normal operation with all keys active. Note: Pressing the "CLEAR" key at any time during the batching process deactivates the Setpoints, STOPS the Batch Routine and the unit returns to the normal operating mode. Pressing the START/STOP key either STARTS PAUSES or RESTARTS the batch process, depending on where in the batch routine the key was pressed. PAUSE mode is indicated with a flashing P. Outputs are de-energized except when the batch is in process. When target cutoff is reached, the outputs are latched OFF and will not reactivate until the next batching sequence. The following setpoint configurations can be used with the Bat1 and Bat2 batch routines: Sx, Sx.P, Sx.d, Sx.P.d, and DUAL. *Note: in DUAL mode, target pre-act values can be set by pressing and holding the SET key for 5 seconds. Set Time and Date position to Un for TNG printout. (OP3-3.5). 17

Bat2 - FUNCTIONAL OPERATION - "AUTOMATIC BATCHING" MODE The "Automatic Batching" Mode operates as follows: A. The START/STOP key is pushed. B. The "Setpoint" indicator LED turns "On". C. The unit automatically switches to the "NET" weighing mode. (If configured for NET batching.) D. An automatic "AUTO TARE" operation takes place. E. Ingredient 1 Setpoint output (if enabled) is activated. All keys except CLEAR and START/STOP are locked out during Run. F. When the displayed weight reaches or exceeds the target value *, the output is deactivated. G. The "Setpoint" indicator LED turns "off". H. Timer 1 phase begins. The unit "Pauses" for 1 to 10 seconds, depending on the Timer 1 value. If timer 1 is turned "Off", the unit enters an indefinite "Pause" mode, and the START/STOP key must be pushed to continue. PAUSE mode is indicated with a flashing P. During Pause the Tare key is functional. I. Upon timeout (or pushing the START/STOP key), the unit will do a "Demand" printout. J. An "AUTO TARE" operation takes place. K. Ingredient 2 output (if enabled) is activated. L. When the displayed weight reaches or exceeds the target value *, the setpoint is deactivated. M. The "Setpoint" indicator LED turns "off". N. If enabled, Timer 2 phase begins, otherwise a Demand printout is initiated when the weight is stable. (No motion). O. Upon timeout, the unit will do a "Demand" printout. P. The unit returns to normal operation in the "Gross" mode. Note: Pressing the "CLEAR" key at any time during the batching process deactivates the outputs, STOPS the Batch Routine and the unit returns to the normal operating mode. Pressing the START/STOP key either STARTS PAUSES or RESTARTS the batch process, depending on where in the batch routine the key was pressed. PAUSE mode is indicated with a flashing P. Outputs are de-energized except when the batch is in process. When target cutoff is reached, the outputs are latched OFF and will not reactivate until the next batching sequence. The following setpoint configurations can be used with the Bat1 and Bat2 batch routines: Sx, Sx.P, Sx.d, Sx.P.d, and DUAL. * Note: in DUAL mode, target pre-act values can be set by pressing and holding the SET key for 5 seconds. Set Time and Date position to Un for TNG printout. (OP3-3.5). 18

(This page not printed) Revision history Rev 0 JDS INITIAL RELEASE 19