(SEL.OP2) SETPOINT CONFIGURATION The 7600E Digital Weight Indicator is available with four (4) control inputs and four (4) control outputs when equipped with the optional Digital Input/Output (DIO) module. Setpoint outputs can be configured in the following modes: Four independent setpoints with pre-act. (V3.98.0 and later) Two Setpoints and zero band. Two Setpoints, with pre-act, and zero band. Two Setpoints, with dribble control. Two Setpoints, with pre-act and dribble control. One setpoint with pre-act, dribble control, tolerance and Zero Band output. "HI - LO" Alarm Control. "OVER/UNDER" Check Weigh Control. Setpoints can be used in a straight setpoint system or as part of either a "Manual Batching" or "Automatic Batching" system. When configured for batching, the setpoints are de-energized except when the batch is in process. When setpoint cutoff is reached, the setpoints are latched OFF and will not reactivate until the next batching sequence. A "Zero Band" (ZBD), around GROSS ZERO is available for monitoring an "empty scale" - in certain setpoint configurations. Rev 0 1
DEFINING SETPOINT PARAMETERS PARAMETER DESCRIPTION ID OUTPUT CHANGE Setpoint (Target) Weight value desired at end of weighing operation. SP WT > or = SP Pre-act Weight value which is set to allow for material in suspension Pr WT > or = SP - Pr Dribble Weight value at which material flow changes, usually from "fast" to "slow" feed. dr WT > or = SP-(dr)-Pr Tolerance Band Weight band around setpoint HI,Lo trg -LO > WT > trg +HI Zero Band Weight band (±) around GROSS ZERO used to define "empty scale". ZBD 0 - x > WT > 0 + x NOTES: 1. Front panel LED's for setpoints 1 and 2 are ON when respective outputs are ON. 2. In Batching modes (BAT1 & BAT2) the setpoint outputs are latched while running. 2
PARAMETER SEL.OP2 (SETPOINT OPERATION) GROSS NET TARE RECALL PARAMETER SELECTION 2.0 OFF SUBPARAMETER DATA SELECTION OFF SP ou bat1 bat2 DEFINITION Setpoints "Off". Zero Band (Parameter "10") is still functional Setpoint mode Over/Under (Check weighing mode) Manual Batch mode, pauses between setpoints Automatic Batch mode, continues without pause between setpoints (2.0 SP) SETPOINT OPERATION (Straight Setpoints) 2.2 OFF Setpoint 1 - "OFF" SI Setpoint 1 S1.P S1.d S1.P.d DUAL Setpoint 1 with Pre-Act Setpoint 1 with Dribble Setpoint 1 with Pre-Act and Dribble Setpoint 1a, 1b Two/four independent setpoints with Pre-Act 2.3 Gr net dsp Setpoint1 tracks GROSS weight only NET weight only Displayed weight 2.4 POS Setpoint 1 is OFF when weight < SP. zer Setpoint 1 is ON when weight < SP. 2.6 OFF Setpoint 2 - "OFF" S2 Setpoint 2 S2.P S2.d S2.P.d DUAL tol Setpoint 2 with Pre-Act Setpoint 2 with Dribble Setpoint 2 with Pre-Act and Dribble Setpoint 2a, 2b Two/four independent setpoints with Pre-Act Tolerance for Setpoint 1 2.7 Gr net dsp Setpoint2 tracks GROSS weight only NET weight only Displayed weight 2.8 POS Setpoint 2 is OFF when weight < SP value zer Setpoint 2 is ON when weight < SP value 2.10 Zbo Zero band value (insert weight value) 2.11 Off Hysteresis, Provides 3 grads to prevent relay chatter s.p.d (i.e) On SP1.trG (1000) SP1.PrE (5) SP1.drb (10) Main and Fast Feed are on until weight reaches 990 (1000-10), then Fast Feed turns off and Main stays on until pre-act at 995. (1000-5) 3
PARAMETER SEL.OP2 (SETPOINT OPERATION) GROSS NET TARE RECALL PARAMETER SELECTION SUBPARAMETER DATA SELECTION DEFINITION (2.0 ou.un) SETPOINT OPERATION (Over/Under) 2.2 OFF Setpoint - "OFF" HL Hi/Lo band tgt Ck1 Ck2 Ck3 Target with +/- band Check Weigher 1 Check Weigher 2 Check Weigher 3 2.3 Gr net dsp Setpoint tracks GROSS weight only NET weight only Displayed weight 2.4 POS Setpoint 1 is OFF when Lo zer Setpoint 1 is ON when Lo 2.5 POS Setpoint 1 is OFF when Accept zer Setpoint 1 is ON when Accept 2.6 POS Setpoint 1 is OFF when Hi zer Setpoint 1 is ON when Hi 2.10 Zbo Zero band value (insert weight value) 2.11 Off Hysteresis, Provides 3 grads to prevent relay chatter On 2.12 Off On Enables Bar Graph Legends HL Lo (950) Lo is ON until weight reaches 950, then Accept is ON until 1050, (i.e) tgt (i.e) Hi (1050) Target (1000) Lo (50) Hi (50) Ck1 Target (1000) Accept (10) OofB (50) Ck2 Target (1000) Accept (10) OofB (50) Ck3 Target (1000) Accept (10) and Hi is ON above 1050 (2.4-2.6 = POS) Lo is ON until weight reaches 950, then Accept is ON until 1050, and Hi is ON above 1050 (2.4-2.6 = POS) Target with Accept and Out of Bounds setpoints. Bar graph 1. Target output is ON with weight within target range, Accept ON within acceptable range, OoB ON when outside acceptable range. Target with Accept and Out of Bounds setpoints. Bar graph 2. Target output is ON with weight within target range, Accept ON within acceptable range, OoB ON when outside acceptable range. Target with Accept setpoint. Bar graph 3. Target output is ON with weight within target range, Accept ON outside of acceptable range. 4
PARAMETER SEL.OP2 (SETPOINT OPERATION) GROSS NET TARE RECALL (2.0 Bat1) SETPOINT OPERATION (Manual Batch) 2.2 OFF Setpoint 1 - "OFF" SI Setpoint 1 S1.P S1.d S1.P.d DUAL Setpoint 1 with Pre-Act Setpoint 1 with Dribble Setpoint 1 with Pre-Act and Dribble Setpoint 1a, 1b Two/Four independent setpoints with Pre-Act 2.3 Gr net dsp Setpoint1 tracks GROSS weight only NET weight only Displayed weight 2.4 POS Setpoint 1 is OFF when weight < SP. zer Setpoint 1 is ON when weight < SP. 2.6 OFF Setpoint 2 - "OFF" S2 Setpoint 2 S2.P S2.d S2.P.d DUAL Setpoint 2 with Pre-Act Setpoint 2 with Dribble Setpoint 2 with Pre-Act and Dribble Setpoint 2a, 2b Two/Four independent setpoints with Pre-Act 2.7 Gr net dsp Setpoint2 tracks GROSS weight only NET weight only Displayed weight 2.8 POS Setpoint 2 is OFF when weight < SP value zer Setpoint 2 is ON when weight < SP value 2.10 Zbo Zero band value (insert weight value) 2.13 Off On Restart after power outage Off: Restart with Start key or remote Start input On: Restart with Start key AND yes to resume 5
PARAMETER SEL.OP2 (SETPOINT OPERATION) GROSS NET TARE RECALL (2.0 Bat2) SETPOINT OPERATION (Auto Batch) 2.2 OFF Setpoint 1 - "OFF" SI Setpoint 1 S1.P S1.d S1.P.d DUAL Setpoint 1 with Pre-Act Setpoint 1 with Dribble Setpoint 1 with Pre-Act and Dribble Setpoint 1a, 1b Two/Four independent setpoints with Pre-Act 2.3 Gr net dsp Setpoint1 tracks GROSS weight only NET weight only Displayed weight 2.4 POS Setpoint 1 is OFF when weight < SP. zer Setpoint 1 is ON when weight < SP. 2.5 1-10 sec Time delay before auto-print and continue Batch 2.6 OFF Setpoint 2 S2 Setpoint 2 S2.P S2.d S2.P.d DUAL Setpoint 2 with Pre-Act Setpoint 2 with Dribble Setpoint 2 with Pre-Act and Dribble Setpoint 2a, 2b Two/Four independent setpoints with Pre-Act 2.7 Gr net dsp Setpoint2 tracks GROSS weight only NET weight only Displayed weight 2.8 POS Setpoint 2 is OFF when weight < SP value zer Setpoint 2 is ON when weight < SP value 2.9 1-10 sec Time delay before auto-print and return to Normal weigh mode 2.10 Zbo Zero band value (insert weight value) 2.13 Off On Restart after power outage Off: Restart with Start key or remote Start input On: Restart with Start key AND yes to resume 6
FUNCTIONAL DESCRIPTION Four setpoint (DUAL) setpoint mode DUAL mode is the (four independent) setpoint operation mode, where cutoff occurs when the weight is greater than or equal to ( ) the setpoint value. B. The display alternates between the setpoint entry parameter (SP1-a) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad, push the ENT key to Save. D. Push the SET key. The display will step to the next selection (SP1-b,.SP2-a,SP2-b.) E. Push SET to exit. F. The setpoint values may be recalled at any time by pushing the SET key repeatedly. If Pre-acts are required for any of the DUAL setpoint outputs: A. Push the SET key and HOLD for 5 seconds. B. The display alternates between the setpoint entry parameter (SP1-a) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad, push the ENT key to Save. D. Push the SET key. The display will step to the next selection (SP1P-a, SP1-b,.SP1P-b, SP2-a, SP2P-a, SP2-b, SP2P-b.). SPx-y = target value, SPxP-y = pre-act value. E. Push SET to exit. 7
FUNCTIONAL DESCRIPTION Straight setpoint mode SP mode is the setpoint (SP) operation mode, where cutoff occurs when the weight is greater than or equal ( ) to the setpoint (SP). Zero Band output is available. B. The display alternates between the setpoint entry parameter (SP1-trg) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP2-trg.) E. Push SET to exit. F. The setpoint values may be recalled at any time by pushing the SET key repeatedly. G. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 8
FUNCTIONAL DESCRIPTION Pre-act mode PR adds a "pre-act" value which allows for "in-flight" material compensation. The cutoff occurs when the weight is greater than or equal to ( ) the setpoint (SP) value minus the pre-act (Pr) value. Note: This allows changes in setpoint values while maintaining the pre-act setting. Zero band output is available. B. The display alternates between the setpoint entry parameter (SP1-trg) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP1-PrE.) Enter the pre-act weight value for SP1 target value. Push the "ENT" key to Save. E. Push the SET key. Enter SP2-trg and SP2-PrE as above. F. Push SET to exit. G. The setpoint values may be recalled at any time by pushing the SET key repeatedly. H. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 9
FUNCTIONAL DESCRIPTION Dribble mode Dribble mode adds a "dribble" (dr) which provides a "two-speed" (fast feed, slow feed) cutoff to enhance accuracy. The basic setpoint is used for slow feed, while the additional cutoff (fast feed) occurs when the weight is greater than or equal to ( ) the setpoint minus the dribble value. Note: This allows changes to the setpoint target value while maintaining the same amount of fast to slow feed differential. Zero band output is not available if SP2 is used in (dr) mode.) B. The display alternates between the setpoint entry parameter (SP1-trg) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP1-drb.) Enter the Dribble Weight differential value for SP1 target value. Push the "ENT" key to Save. E. Push the SET key. Enter SP2-trg and SP2-drb as above. F. Push SET to exit. G. The setpoint values may be recalled at any time by pushing the SET key repeatedly. H. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. Not available if SP2 is set for (dr) dribble mode. 10
FUNCTIONAL DESCRIPTION Dribble mode with Pre-act Provides both a dribble (dr) and preact (Pr) to setpoint configuration. The slow feed cutoff occurs when the weight is greater than or equal to ( ) the setpoint minus the pre-act value. The fast feed cutoff occurs when the weight is greater than or equal to ( ) the setpoint minus the pre-act and minus the dribble value. Note: This allows changes in setpoint settings while maintaining the pre-act and dribble settings. Zero band output is not available if SP2 is used in (dr) mode. B. The display alternates between the setpoint entry parameter (SP1-trg) and current setpoint value. C. Enter the desired setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP1-PrE.) Enter the pre-act weight value for SP1 target value. Push the "ENT" key to Save. E. Push the SET key. The display will step to the next selection (SP1-drb.) Enter the Dribble Weight differential value for SP1 target value. Push the "ENT" key to Save. F. Push the SET key. Enter SP2-trg, SP2-PrE, and SP2-drb as above. G. Push SET to exit. H. The setpoint values may be recalled at any time by pushing the SET key repeatedly. I. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. Not available if SP2 is set for (Dr) dribble mode. 11
FUNCTIONAL DESCRIPTION Over/Under Hi/Lo mode Provides High, Low, and Accept outputs with the Low level ON when the weight is less than (<) Lo setpoint (SP LO), the High level ON when the weight is greater (>) than Hi setpoint (SP HI), and Accept is ON in between. This is for applications where High and Low settings require direct changes. Zero band output is available. B. The display alternates between the setpoint entry parameter (SP-LO) and current setpoint value. C. Enter the desired LO setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP-HI.) E. Enter the desired HI setpoint value using the 0-9 keypad. Push the "ENT" key to Save. F. Push SET to exit. G. The setpoint values may be recalled at any time by pushing the SET key repeatedly. H. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 12
FUNCTIONAL DESCRIPTION Over/Under Target mode Provides High, Low, and Accept outputs the same as direct entry above, except that a direct entry is made only for a target weight and High/Low settings become dependent upon that weight. The Low level is ON when the weight is less than (<) the Target minus the (Lo) value. The High level is ON when the weight is greater than (>) the Target plus the (HI) value. Accept is ON in between. Zero band output is available. B. The display alternates between the setpoint entry parameter (SP-trG) and current setpoint value. C. Enter the desired Target setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (SP-LO.) E. Enter the desired LO differential setpoint value using the 0-9 keypad. Push the "ENT" key to Save F. Push the SET key. The display will step to the next selection (SP-HI.) G. Enter the desired HI differential setpoint value using the 0-9 keypad. Push the "ENT" key to Save. H. Push SET to exit. I. The setpoint values may be recalled at any time by pushing the SET key repeatedly. J. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 13
FUNCTIONAL DESCRIPTION Over/Under Ck1 Provide Check-Weigh outputs for Within Target Range, Within Acceptable Range, and Out of Bounds Range. Direct entry is made only for a Target value (Ck-cnt) while the Acceptable and Out of Bounds settings become dependent upon that weight. Function of the bar graph as follows: If weight is within acceptable (Target) range, Within Target bar graph segment is ON. If outside target range, but within Out of Bounds range, the Lo (Hi) Acceptable segment will be ON. If outside of the Out of Bounds range, both the Lo (Hi) Acceptable and Out segments will be ON. Zero band output is available. B. The display alternates between the setpoint entry parameter (Ck-Cnt) and current setpoint value. C. Enter the desired Target setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (ACCEPt.) E. Enter the desired setpoint value for the acceptable weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. F. Push the SET key. The display will step to the next selection (Out.bnd.) G. Enter the desired setpoint value for the out of bounds weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. H. Push SET to exit. I. The setpoint values may be recalled at any time by pushing the SET key repeatedly. J. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 14
FUNCTIONAL DESCRIPTION Over/Under Ck2 Same function as CK1 with the exception - Function of the bar graph as follows: Only one bar graph segment is ON at a time. Either Out LO, Accept LO, Within Target, Accept HI, Out HI. Zero band output is available. B. The display alternates between the setpoint entry parameter (Ck-Cnt) and current setpoint value. C. Enter the desired Target setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (ACCEPt.) E. Enter the desired setpoint value for the acceptable weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. F. Push the SET key. The display will step to the next selection (Out.bnd.) G. Enter the desired setpoint value for the out of bounds weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. H. Push SET to exit. I. The setpoint values may be recalled at any time by pushing the SET key repeatedly. J. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 15
FUNCTIONAL DESCRIPTION Over/Under Ck3 Provides Check-Weigh outputs for Within Acceptable Range, and Out of Bounds Range. Direct entry is made only for a Target value (Ck-cnt) while the Acceptable setting becomes dependent upon that weight. Function of the bar graph as follows: If weight is within acceptable range, Within Target bar graph segment is ON. If outside target range, both Lo and Lo-Lo (or High and High-High) bar graph segments are ON. Zero band output is available. B. The display alternates between the setpoint entry parameter (Ck-Cnt) and current setpoint value. C. Enter the desired Target setpoint value using the 0-9 keypad. Push the "ENT" key to Save. D. Push the SET key. The display will step to the next selection (ACCEPt.) E. Enter the desired setpoint value for the acceptable weight range (+/- differential from target) using the 0-9 keypad. Push the "ENT" key to Save. F. Push SET to exit. G. The setpoint values may be recalled at any time by pushing the SET key repeatedly. H. Note: Zero Band (ZBO) is set in SEL.OP2 configuration parameter 2.10. 16
Bat1 - FUNCTIONAL OPERATION - "MANUAL BATCHING" MODE The "Manual Batching" Mode operates as follows: A. The START/STOP key is pushed. B. The "Setpoint" indicator LED turns "On". C. The unit automatically switches to the "NET" weighing mode. (If configured for NET batching.) D. An automatic "AUTO TARE" operation takes place. E. Ingredient 1 Setpoint (if enabled) is activated. All keys except CLEAR and START/STOP are locked out during Run. F. When the displayed weight reaches or exceeds the target value *, the output is deactivated. G. A Demand printout takes place. H. The unit enters a "Pause" mode. (During Pause the Tare key is functional.) PAUSE mode is indicated with a flashing P. I. When the START/STOP key is again pushed, Ingredient 2 output (if enabled) is activated. J. An automatic "AUTO TARE" operation takes place. K. When the displayed weight reaches or exceeds the Setpoint 2 target value *, the output is deactivated. L. A Demand printout takes place and the unit returns to normal operation with all keys active. Note: Pressing the "CLEAR" key at any time during the batching process deactivates the Setpoints, STOPS the Batch Routine and the unit returns to the normal operating mode. Pressing the START/STOP key either STARTS PAUSES or RESTARTS the batch process, depending on where in the batch routine the key was pressed. PAUSE mode is indicated with a flashing P. Outputs are de-energized except when the batch is in process. When target cutoff is reached, the outputs are latched OFF and will not reactivate until the next batching sequence. The following setpoint configurations can be used with the Bat1 and Bat2 batch routines: Sx, Sx.P, Sx.d, Sx.P.d, and DUAL. *Note: in DUAL mode, target pre-act values can be set by pressing and holding the SET key for 5 seconds. Set Time and Date position to Un for TNG printout. (OP3-3.5). 17
Bat2 - FUNCTIONAL OPERATION - "AUTOMATIC BATCHING" MODE The "Automatic Batching" Mode operates as follows: A. The START/STOP key is pushed. B. The "Setpoint" indicator LED turns "On". C. The unit automatically switches to the "NET" weighing mode. (If configured for NET batching.) D. An automatic "AUTO TARE" operation takes place. E. Ingredient 1 Setpoint output (if enabled) is activated. All keys except CLEAR and START/STOP are locked out during Run. F. When the displayed weight reaches or exceeds the target value *, the output is deactivated. G. The "Setpoint" indicator LED turns "off". H. Timer 1 phase begins. The unit "Pauses" for 1 to 10 seconds, depending on the Timer 1 value. If timer 1 is turned "Off", the unit enters an indefinite "Pause" mode, and the START/STOP key must be pushed to continue. PAUSE mode is indicated with a flashing P. During Pause the Tare key is functional. I. Upon timeout (or pushing the START/STOP key), the unit will do a "Demand" printout. J. An "AUTO TARE" operation takes place. K. Ingredient 2 output (if enabled) is activated. L. When the displayed weight reaches or exceeds the target value *, the setpoint is deactivated. M. The "Setpoint" indicator LED turns "off". N. If enabled, Timer 2 phase begins, otherwise a Demand printout is initiated when the weight is stable. (No motion). O. Upon timeout, the unit will do a "Demand" printout. P. The unit returns to normal operation in the "Gross" mode. Note: Pressing the "CLEAR" key at any time during the batching process deactivates the outputs, STOPS the Batch Routine and the unit returns to the normal operating mode. Pressing the START/STOP key either STARTS PAUSES or RESTARTS the batch process, depending on where in the batch routine the key was pressed. PAUSE mode is indicated with a flashing P. Outputs are de-energized except when the batch is in process. When target cutoff is reached, the outputs are latched OFF and will not reactivate until the next batching sequence. The following setpoint configurations can be used with the Bat1 and Bat2 batch routines: Sx, Sx.P, Sx.d, Sx.P.d, and DUAL. * Note: in DUAL mode, target pre-act values can be set by pressing and holding the SET key for 5 seconds. Set Time and Date position to Un for TNG printout. (OP3-3.5). 18