Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.

Similar documents
Installation Instructions

IPG IGNITION GAS PILOTS BACK-LOADED GAS

Operator: Save these instructions for future use!

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

GM Series Dual-Block Multi-Function Gas Control Valves

ACCESSORY KIT INSTALLATION INSTRUCTIONS

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Propane Conversion Kit Instruction

Installation Instructions

Installation Guide No. 160, 5/7/07. Eclipse AirHeat Burners AH-MA Series Version 2

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

Your safety and the safety of others are very important.

Propane Conversion Kit Instruction

PGM PREPIPED GAS MANIFOLD

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

36H SERIES Combination Gas Valve

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Eclipse AirHeat Burners

Propane Conversion Kit Instructions

330 Installation Guide 11/15/2016. ImmersoJet Burner. Version 3

INSTALLATION & OPERATING INSTRUCTIONS FOR THE DS300 BRAZING HEARTH FLAMEFAST (UK) LIMITED

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Safety. Operating instructions Excess air burner BIC..L DANGER. Contents WARNING CAUTION Elster GmbH Edition 06.17

Propane Conversion Kit Instruction

SL G3. Warning

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

330 Installation Guide 10/25/2011. ImmersoJet Burner. Version 2

Installation Guide No. 111, 8/26/05. Winnox Burners. WX Series. Version 1.00

Tightness control TC. Product brochure GB 3 Edition AGA

USER S INFORMATION MANUAL

Automatic Valve Proving Control

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation, use and maintenance instructions. Gas burner (5)

VR46.5V(A)/VR86.5V(A) SERIES

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

INSTALLATION & MAINTENANCE MANUAL FOR RIVERSIDE HYDRONICS BG400 GAS BURNER 140,000 thru 1,400,000 Btu/h

GAS SUPPLY DESIGN GUIDE

Installation Guide 111 2/26/2010. Eclipse Winnox Burners WX Series Version 2

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Installation Guide 205 1/21/2011. Eclipse ThermJet Burners Models TJ TJ2000 Version 2

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

EDUCATION DEPARTMENT ACCU-TEST

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

North American Orifice Metering System

Safety. Operating instructions Burners for gas BIO, BIOA DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Operator: Save these instructions for future use!

G96 Series BASOTROL Dual Operator Valve

GM-7000 Series CE Approved Gas Control Valve

Mixers. Venturi proportional mixers EMM & EMMTR (E2351 rev /07/2017)

GAS SUPPLY APPLICATION GUIDE

Instructions for High Altitude Conversion

Design Guide /01. ThermAir Burners TA Series version 1.10

Conversion instructions from natural gas to propane

Eclipse Tube Firing Burners

553 Series.

Eclipse ThermAir Burners

Installation and Maintenance Instructions

/2004 US/CA

INSTALLATION MANUAL TDR 8 P GAS FIRED ROTISSERIE OVEN

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Natural Gas to L.P. Gas Conversion Kit

ACCESSORY KIT INSTALLATION MANUAL

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

Installation and Maintenance Instructions

Operating instruction

Gas Countertop Griddle

Tightness controls TC 1 3 and TC 4

Magnetic level switch type MR783 Instruction Manual

Safety. Operating instructions Burners for gas ZIO 165, ZIO 200 DANGER. Contents WARNING CAUTION Edition 11.11

Safety Powder Spray Systems

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

IS YOUR FLAP VALVE IN COMPLIANCE WITH NFPA ?

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

SPECIFICATIONS ATTENTION

Natural Gas to L.P. Gas Conversion Kit

Installation Guide 208 2/4/2013

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

MEGR-1912 Instruction Manual

Dual Solenoid Gas Valve Installation

Installation, Operation and Maintenance Manual for Back Pressure Regulator

BGA158 Series CE Approved Class B Shutoff Gas Valve

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Job Number Plant Location 123 Roadrunner Avenue, Tombstone, AR Fuel Devices

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

DUCT BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

BGA158 Series CE Approved Class A Shutoff Gas Valve

User, Installation, Servicing and Conversion Instructions. Opus 700 Gas Chargrills OG7401, OG7402, OG7403 & OG7404

Eclipse RatioMatic Burners RM Series Version 5

Transcription:

Operating instructions GB VD Burners Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage. To the Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, qualified service technician for installation, start-up or service work. Save this manual for future reference.

REV 26/10/16 2 GB VD Burners Operating instructions -

Table of Contents General information... 4 Introduction... 4 Manufacturer information... 4 Users... 4 Aim... 4 General burner information... 4 Electrical wiring and gas connection... 4 Drawings & specifications... 4 Specifications... 5 Safety... 6 Risks... 6 Professional use... 6 Technical guide... 6 Burner installation... 7 Control system... 8 Burner s adjustment... 9 Burner settings... 9 Maintenance and common issues... 10 Maintenance... 10 List of common issues... 11 Disassembly... 12 Removal of electrical and gas connection... 12 Handling... 12 Storage... 12 Dismantling... 13 Declaration... 13 Plate destruction... 13 List of material... 13 Self-disassembly... 13 Spare parts... 13 VD Burners Operating instructions - 3

General Information 1 INTRODUCTION VD burners is a series designed for air heating solutions in any industrial applications.. Contact our technical support tecnico@bruciatorisantin.com to get VD with gas /air train with blower, command panel with control unit and all devices you need. MANUFACTURER INFORMATION Bruciatori Industriali Santin S.n.c. Via G. di Vittorio, 15 20030 Senago (MI) Phone. +39 02 99 813074 Fax. +39 02 99814391 Email. info@bruciatorisantin.com USERS This Manual has been written for people who will use the product as user or as owner, or installer and/or for maintenance service and/or for the final dismantling of the burner made by BRUCIATORI INDUSTRIALI SANTIN. AIM Used with doc other VD documents - http://www.bruciatorisantin.com/en/reserved - the purpose of this manual is to ensure safety use and installation. GENERAL BURNER INFORMATION Available in the datasheet VD 40-1 The combustion air must be free of any contaminants. Always provide opening to the outdoors in order to have fresh air. O2 min 18% ** Provide access to the burner for inspection and maintenance services ** ELECTRICAL WIRING AND GAS PIPING Electrical wiring and gas piping must comply all applicable local standards as: CEI EN 61439-1 and 746-2. CAUTION! It is very dangerous to use any fuel burning equipment unless it is equipped with flame sensing device and automatic suitable shut off valves. Contact Bruciatori Santin technical support DRAWINGS & SPECIFCATIONS See the datasheet 40-1. 4 VD Burners Operating instructions -

SPECIFICATIONS Model VD Standard version max 880 KW Min inlet air O2% 18 Fuel Natural gas / LPG Pilot Optional Max upstream air T C Max Downstream air T C Max rising temperature About 200 About 500 About 400 Duct air pressure drop On the burner 1 to 3 mbar Ignition With ignition transformer 8 KV Flame detection UV or Flame rod Material Stainless steel wings Connection BSP (Contact us for NPT thread) Declaration of conformity CE VD Burners Operating instructions - 5

Safety 2 Before installation and use, read these instructions carefully. The burner must be installed and commissioned according to the place of use. The Bruciatori Industriali Santin is not liable for damages caused by inobservance of the following manual or incorrect use of the burner. Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage. RISKS WARNING The burner could have hot surface and different parts could be sharp. Always wear personal protective equipment when moving closer to the burner. All gas burners are able to produce explosions if improperly installed. Do not forget to follow any safety steps. Do not switch on the burner if it is damaged. Do not allow exhaust to accumulate in the work area. Poisoning and explosion risks. Contact Bruciatori Industriali Santin for further information. PROFESSIONAL USE Only qualified personnel with specific technical and/or training experience with combustion systems must operate on the burner and on all mechanical and electrical part of the combustion system. Technical guide 3 In this chapter you will find all information to develop the system with the correct control system, install and adjust the burner. Please read thoroughly. 6 VD Burners Operating instructions -

BURNER INSTALLATION Process air stream Heated air Tips: Duct profile plate Use adjustable profile plate in order to set the air pressure drop (2,5 mbar) across the burner Keep the burner in the middle of the duct Straight duct after the burner must be min 1500 mm Any reduction of the duct after the burner must be an angulation not more than 7 Mounting plate may vary according to customer and application needs. Please note. Do not forget to inert the gasket insulation between duct wall and burner. Contact us for the correct product tecnico@bruciatorisantin.com VD Burners Operating instructions - 7

Please note. The pipe connection is a critical choice. The following suggestions can help you: Ensure that size of air and gas pipe are large enough to avoid excessive pressure loses. The number of elbows is kept to a minimum. Flexible pipe can cause more pressure drop than standard pipe. Check flexible detail. Put in a pipe union in a burner can simplify maintenance service. Note For all and full information about VD series, refer to the Datasheet 40-1. For all information about gas and air piping, refer to the Gas/air pipes Guide Before switch on the burner please make the following checks: Control air and gas leaks Ensure that bolts and all components are properly installed Ensure that power supply is correct, according to wiring diagram Ensure that gas train is properly installed and in the correctly oriented. Ensure the correct blower rotation. CONTROL SYSTEM: ü Gas input range is controlled by a actuator and butterfly valve placed on the gas pipe. Pilot is an optional for VD1 and VD2 (185 and 370 mm) ü Ignition voltage should be 8KV (ask for our model 1820) ü Air pressure switches must control duct air flow ü Use suitable control unit to control the system 8 VD Burners Operating instructions -

Burner s adjustment 4 BURNER SETTINGS In this chapter you will find all steps on how to adjust the burner system. WARNING Do not bypass any steps. Fire or explosion could result. All gas valve and cocks must be closed. Don not touch electrodes. Electroshock could result. Air / gas taps must be open during measures. Do not forget to close after that. Leak could result. Set the ratio regulator in order to have a stable pressure. The pressure should not exceed the maximum pressure rating of gas pressure switch. Set the air pressure switch 15 mbar below the blower pressure. Set the low gas pressure switch 15 mbar below the gas pressure inlet the gas train. Set the high gas pressure switch 15 mbar above the gas pressure inlet the gas train If the system doesn t start and stop automatically you must close all gas cocks. Fire or explosion could result. 1. Start the duct fan and check the correct rotation. During this operation gas valves must be closed. Set the air pressure drop using a manometer as in the picture below. AIR FLOW Heated air Duct profile plate Tap 1 Tap 2 VD Burners Operating instructions - 9

2. Ignite the burner. Make sure that the supply air fan is running. Adjust the gas regulator 20/30 Mbar. Move the gas control vale at low fire, open all manual gas valve and initiate the ignition sequence. If the burner does not ignite, try again and purge out the air into the piping. 3. Set the high fire gas, open taps on the gas and measure the pressure drop between the tap on the burner and and tap on the duct. If max input is not achieved, check the butterfly valve and/or the gas regulator. See the chart in the datasheet 4. Set the low fire gas moving the control valve to minimum position. The burner should work with a stable and blue flame uniform along the length of the burner. 5. Check gas setting and all devices in low and high fire gas. 6. Stop the system and repeat again. To stop the system, close the following valves: -All manual gas cock valves -All automatic shut-off valves Maintenance and common issues 5 MAINTENACE An accurate maintenance program extends the life of the machine and assures high performance. The general cleaning of the machine represents a very important security factor together with the compliance of the following instructions: WARNING We suggest checking yearly the parts in the list below. If the environment is dirty the check must be monthly. a) Leak test on gas train. b) Check the correct operation of control unit sequence and all alarm system. c) Check gas and air pressure switches. d) Check flame rod and ignition electrode conditions. e) Control air and gas ratio f) Test valves and solenoids. g) Visual check of cable and gas/air connections. h) Control the flame thought the pipe sight in order to control the flame conditions. i) Control all components and clean / replace if necessary. 10 VD Burners Operating instructions -

LIST OF COMMON ISSUES Problem Possible Cause Possible solution Burner does not start There is incorrect power supply Check the wiring diagram Burner has an insufficient flame signal The low fire flame is unstable and burner has an incorrect air/gas ratio The burner is unstable and produces smoke and soot The burner does not reach maximum capacity The system can not start the ignition sequence The burner does not reset after block The spark electrode is dirty The spark electrode is not grounded to the burner UV or flame sensor are dirty Flame sensor is grounded to the burner Insufficient air Insufficient gas Incorrect air / gas ratio Incorrect air /gas ratio Devices on gas train are dirty Gas pressure low Solenoids/valve gas flow regulator have closed Blower rotates in incorrect direction Air pressure switch does not work Min gas pressure switch does not work Max gas pressure switch does not work Control unit is damaged Power supply is off Control unit is damaged Clean the spark electrode Clean the spark electrode Clean the flame sensor Check and adjust the position of ceramic insulation Adjust the air regulator Adjust gas regulator Adjust the gas/air setting Adjust the gas/air setting Clean all possible devices on gas train or replace them Adjust gas pressure Adjust gas flow regulators Check blower wiring Check air pressure switch adjustment Check min gas pressure switch adjustment Check max gas pressure switch adjustment Check the correct operation of control unit Check the wiring diagram and main power line Check the correct operation of control unit VD Burners Operating instructions - 11

Disassembly 6 REMOVAL OF ELECTRICAL AND GAS CONNECTIONS WARNING Only qualified personnel with specific technical and/or training experience with combustion systems must operate on the burner and on all mechanical and electrical part of the combustion systems. During this operation all gas valve and cocks must be closed. HANDLING There are two possible ways of handling: By wooden box containing the machine; By simple shifting of the machine. For both handlings, risks of falls, bumps or upsetting due to the movement of load should be avoided. Suitable accessories should be used to move the box. Protect the components from: Weather Dirt Moisture Excessive temperature and humidity STORAGE If the machine has to be stored for a considerable period of time, it has to be protected from humidity and dust. Wrap up with plastic material for better isolation. 12 VD Burners Operating instructions -

Dismantling 7 DECLARATION Burner dismantling can be done directly by the customer, following the indications below. PLATE DISTRUCTION Remove all machine plates on the burner and destroy them completely. LIST OF MATERIALS The burner does not contain any unsafe material. Materials for possible disassembling are classified as follows: ü Metallic parts of iron, copper, stainless steel, cast iron and aluminium; ü Plastic; SELF-DISASSEMBLY If the Customer wish to disassemble the machine by himself, it is necessary to separate different materials and commit local companies for waste disposal. Spare parts 8 For spare parts information contact our technical support Note. In accordance with the manufacturer s policy of continual product improvement, the product presented in this document is subject to change without notice or obligation. All data / graphs shown in this document are approximate. Copyright 2015 By Bruciatori Industriali Santin S.n.c. All right reserved. This publication shall not be copied, distributed, transmitted, translated, in any form or by any means, to any third parties, without express written consent of Bruciatori Industriali Santin S.n.c. VD Burners Operating instructions - 13

BRUCIATORI INDUSTRIALI SANTIN Snc Di Santin Massimiliano & Santin Alessandro HEADQUARTERS: VIA DON MAURO BONZI 32 2033 DESIO (MI) HEAD OFFICE: VIA G. DI VITTORIO 15 20030 SENAGO (MI) TEL: 02/99813074 FAX: 02/99814391 P.I. 03075700967 Email: info@bruciatorisantin.com Website: www.bruciatorisantin.com Non è possibile visualizzare questa immagine. 14 VD Burners Operating instructions -