VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

Similar documents
VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

DRU/HE THREE-WAY ROTARY VALVE PN10 AND HE25/32 EXTENSION

2-port and 3-port seat valves, PN16

2-port and 3-port valves PN 16

VZL valve - 2/3/4-way

3-port seat valves with externally threaded connection, PN 16

Seated valves VRB 3, VRG 3

2-Port and 3-Port Seat Valves with Female Thread, PN16

V5434T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

2-port seat valves PN25 with externally threaded connections

Type overview. R B2 en-gb subject to changes 1

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

V311. Venta. Three-way Plug Valve, Flanged PN 16

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Two-port valves, male threaded, PN25

AVP-F. p setting range (bar) Code No. 003H6200

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

V5012C Kombi-DP Diaphragm Unit RETROFIT AUTOMATIC DP CONTROLLER

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

2-Port Seat Valves with Flange, PN 16

Products no longer available

Overview of types. Technical data. Safety notes

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

2-Port Seat Valves with Flange, PN 16

B2KL: 6-way ball valve with male thread, PN 16

Radiator valves VDN2.. VEN2.. VUN2..

Overview of types. Technical data

Pressure independent control valve (PICV) FLOWMATIC

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Two-port seat valves

Products no longer available

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

Radiator valves VDN1.. VEN1..

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

AVPQ/AVPQ-F, PN 16. Application

Floor heating. Floor heating manifolds Distributors

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Pressure balanced valves (PN 25)

Rotary valves HRB 3, HRB 4

ADCATROL PNEUMATIC CONTROL VALVES V403 (V403 globe valves series with linear actuators PA or EL series)

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Pressure reducing valves Index

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

3-way control valves VK 3

VBS-9263 Series. Application. Features. Applicable Literature

Rotary valves HRB 3, HRB 4

PCTV/PCMTV/PCTVS15-25

HERZ - Compact Flow Controller with

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

3 & 4-Way Mixing & Diverting Valves

Pressure reduction controller (PN 16, 25, 40)

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

HERZ-Motorised flow controler

Pressure Independent Control Series

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

VFPIP/VFPIM/VFPI 15-25

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

D05T Compact Design Pressure Regulating Valves

CALEFFI. Ball zone valves. series /03 GB

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Flow control valves Series RFU - RFO 2/

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

PCMTV Pressure independent control valves, DN20-DN32 with integrated flow limiter for thermal emitters and differential pressure regulator

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

CALEFFI. Motorised temperature regulating unit for heating systems. 167 series 01239/15 GB. replaces dp 01239/13 GB. Function

RA-N radiator valves with integrated presetting and self-sealing tailpiece

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

shutoff valves 900 Series psig Manual Shutoff Valves

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

HERZ - Compact Flow Controller with

Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

Technical Data Sheet T 2025

VB-7263 Series. Application. Features. Applicable Literature

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Propor tional Re lief Valve s

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Transcription:

VGx-xx-xx Externally Threaded Control all Valves PN25 (DN15 TO DN32) PPLICTION The VG2 2-Way and VG3 3-Way Control all Valves control hot and chilled water with glycol solutions up to 50% according to VDI2035 in heating, ventilating, and air conditioning (HVC) systems to provide two-position or modulating functions. Features Sizes from DN15 to DN32 with external (male) SPP (G) connections 1" to 2". Equal percentage flow characteristic. Compatible MVN Rotary Valve ctuators: 2-position, floating, modulating, non-spring return. Removable manual operating handle to control valve during installation or in the event of power failure. ctuator can be mounted on the valve in any of four orientations. Wide range of kv choices from 0.25 to 25. Nickel-chrome plated brass ball and stem. Valve installs in a globe valve "T" pattern, no extra elbows or piping required. Mixing or diverting control for 3-way valves. Leakage rate, air bubble-tight (according to EN 12266-1). Specifications Valve type SPECIFICTION DT Control all Valve ody pattern 2-way (VG2-xx-xx), 3-way (VG3-xx-xx) Nominal pressure rating PN25 Media temperature range +5 +120 C (+41 +248 F) Connection type Male SPP, threaded connections, flat sealing Controlled fluid Leakage rating VG2 VG3 Chilled or hot water according to VDI2035 with up to 50% Glycol. Not for use with steam or fuels. Leakage rate, air bubble-tight according to EN 12266-1 Leakage rate, air bubble-tight according to EN 12266-1 for - port, Rate I according to EN 1349 and EN 60534-4 for - port (0.1% of kv) Capacity index (Kvs) see Table 1 and Table 2 Close-off pressures see Table 1 and Table 2 Materials: ody rass Stem rass all Chrome-plated brass Seat Teflon seals with EPDM O- rings Flow control insert Noryl ody Style: 2-way ball valve 3-way ball valve ody pressure rating Flow Characteristics: 2-way 3-way pprovals/standards Straight-through flow, full or reduced port using patented flow control insert -- flow, full or reduced port using patented flow control insert max. 2482 kpa (360 psi) at 120 C (248 F) Equal percentage with flow control insert Port to : Equal percentage; Port to : Linear CE U.S. Registered Trademark Copyright 2014 Honeywell Inc. ll Rights Reserved EN0-0717GE51 R0914

VGx-xx-xx EXT. THREDED CONTROL LL VLVES PN25 (DN15 TO DN32) SPECIFICTION DT DN K vs - O.S. no. 15 20 25 32 Table 1. VG2 Two-way control ball valves 0.25 VG2-15-0.25 0.4 VG2-15-0.4 0.63 VG2-15-0.63 1 VG2-15-1 1.6 VG2-15-1.6 2.5 VG2-15-2.5 4 VG2-15-4 6.3 VG2-15-6.3 4 VG2-20-4 6.3 VG2-20-6.3 8.6 VG2-20-8.6 6.3 VG2-25-6.3 10 VG2-25-10 16 VG2-25-16 25 VG2-25-25 16 VG2-32-16 25 VG2-32-25 Close-off pressure with MVN Rotary Valve ctuators (kpa) External thread size 890 1" 890 1 ¼" 680 1 ½" 2" Table 2. VG3 Three-way control ball valves Close-off pressure with MVN DN K vs - K vs - O.S. no. Rotary Valve ctuators (kpa) 15 20 25 32 0.63 0.50 VG3-15-0.63 1 0.80 VG3-15-1 1.6 1.28 VG3-15-1.6 2.5 2.00 VG3-15-2.5 4 3.20 VG3-15-4 6.3 5.04 VG3-15-6.3 4 3.20 VG3-20-4 6.3 5.04 VG3-20-6.3 8.6 6.88 VG3-20-8.6 6.3 5.04 VG3-25-6.3 10 8 VG3-25-10 16 12.8 VG3-25-16 25 20 VG3-25-25 16 12.8 VG3-32-16 25 20 VG3-32-25 340 External thread size 1" 1 ¼" 1 ½" 270 2" EN0-0717GE51 R0914 2

VG EXTERNLLY THREDED CONTROL LL VLVES ND MR3 CTUTORS SPECIFICTION DT V G 2 1 5 0 2 5 LL VLVE 2: 2-WY 3: 3-WY 15: DN15 20: DN20 25: DN25 32: DN32 MLE EXT. THRED Fig. 1. VG product key 0.25: 0.4: 0.63: 1: 1.6: 2.5: 4: 6.3: 8.6: 10: 16: 25: Kvs = 0.25 Kvs = 0.4 Kvs = 0.63 Kvs = 1 Kvs = 1.6 Kvs = 2.5 Kvs = 4 Kvs = 6.3 Kvs = 8.6 Kvs = 10 Kvs = 16 Kvs = 25 Table 3. Valve accessories and replacement parts Part no. Description 5112-19 Replacement stem assembly for 2- and 3-way valve 5112-20 Replacement stem assembly for 2- and 3-way valve 5112-21 Replacement stem assembly for 2- and 3-way valve MVN Replacement valve adaptor, standard profile, pre-assembled on the VG valves C-15TF-1 Fittings accessories DN15 VG valves C-20TF Fittings accessories DN20 VG valves C-25TF Fittings accessories DN25 VG valves C-32TF Fittings accessories DN32 VG valves Table 4. Connection sets Connection Pipe size DN O.S. no. Connection set Description Internal thread G ½" 15 C-15TF-1 G ¾" 20 C-20TF G 1" 25 C-25TF G 1-¼" 32 C-32TF Consisting of 1 union nut, 1 tailpiece, and 1 gasket Table 5. Connection set dimensions Connection set a c O.S. no. G 1" G 1/2" C-15TF-1 G 1-1/4" G 3/4" C-20TF G 1-1/2 G 1" C-25TF G 2 G 1-1/4" C-32TF 3 EN0-0717GE51 R0914

VGx-xx-xx EXT. THREDED CONTROL LL VLVES PN25 (DN15 TO DN32) SPECIFICTION DT I I CLERNCE OVE CTUTOR: 19 mm (3/4") CLERNCE OVE CTUTOR: 19 mm (3/4") J K K O D C H G J O D C G E H Fig. 2. MVN with 2-way ball valve (see also Table 6) Fig. 3. MVN with 3-way ball valve (see also Table 7) Table 6. VG2 dimensions (in mm) DN C D G H I J K O 15 74.0 67.1 19.1 48.0 G1" 92.3 71.0 142.1 123.0 36.0 20 85.5 77.2 24.7 52.7 G1¼" 98.05 71.0 152.2 127.7 46.0 25 84.5 84.1 26.8 57.5 G1½" 97.55 71.0 159.1 132.5 50.0 32 102.0 98.1 36.0 63.4 G2" 106.3 71.0 173.1 138.4 65.0 Table 7. VG3 dimensions (in mm) DN C D E G H I J K O 15 74.0 107.1 41.1 49.1 44.0 G1" 92.3 71.0 182.1 124.1 41.0 20 85.5 109.4 46.9 49.1 49.5 G1¼" 98.05 71.0 184.4 124.1 46.0 25 84.5 118.4 44.4 53.1 53.5 G1½" 97.55 71.0 193.4 128.1 50.0 32 107.5 142.3 50.9 63.0 69.0 G2" 109.05 71.0 217.3 138.0 65.0 EN0-0717GE51 R0914 4

VGx-xx-xx EXT. THREDED CONTROL LL VLVES PN25 (DN15 TO DN32) SPECIFICTION DT Mounting When installing the valve care must be taken that the flow direction is correct (see section "Typical Operation" below). The valve must not be mounted with the stem pointing downward. The valve is supplied complete with mounting instructions. The water quality must meet VDI 2035 requirements. NOTE: Mount the actuator by hand, only. Do not use a tool, as this could result in damage Typical Operation ll types of valves should be mounted in the return flow. If the Dp-values exceed 300 kpa, attention should be paid to the development of noise. Fig. 6. Three-way diverting valve operation Two-Way Valves Direction of flow always from port to port Port : Outlet OUTLET OUTLET Fig. 4. Two-way valve operation Three-Way Valves These valves are used preferably as mixing valves. This means: Port : Total flow outlet Port : Controlled flow inlet Port : ypass inlet Fig. 5. Three-way mixing valve operation EN0-0717GE51 R0914 5

OPEN FLOW 2-WY: D 3-WY: - OPEN OPEN OPEN - 2-WY 3-WY - FLOW HONEYWELL 2-WY: OPEN 3-WY: - OPEN IP40 OPEN - 2-WY 3-WY - Fig. 7. Orientation of ball in valve Fig. 8. cceptable valve orientation DISPOSL OF VG CONTROLL LL VLVES OSERVE LOCL REQUIREMENTS ON PROPER WSTE RECYCLING / DISPOSL! Dezincification-resistant brass body Chrome-plated brass ball Teflon seals with EPDM O-rings Noryl flow control insert Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.. La Pièce 16, Switzerland by its uthorized Representative: utomation and Control Solutions Honeywell GmbH öblinger Strasse 17 71101 Schönaich, Germany Phone +49 (0) 7031 637 01 Fax +49 (0) 7031 637 740 http://ecc.emea.honeywell.com EN0-0717GE51 R0914 Subject to change without notice