Productivity. Technician. Maximized. Interpretation Guide

Similar documents
SALX. Interpretation Guide. Salmonella Express System

Productivity. Technician. Maximized. Interpretation Guide. 3M Food Safety 3M Petrifilm Salmonella Express System

EXPERIMENT. Introduction: Microbiology- Rules for Success

SAMPLING GUIDELINES FOR THE BI-AIR FILTER CASSETTE

<788> PARTICULATE MATTER IN INJECTIONS

Corning Microarray Hybridization Chambers

Corning HYPERStack Cell Culture Vessel Closed System

Module 14: Blood Collection and Handling DBS

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

Bt-Cry1Ac & Bt-Cry2A Multi-trait ELISA Kit DAS ELISA for the detection of Bt-Cry1Ac & Bt-Cry2A proteins Catalog number: PSM 14900

CspB ELISA Kit DAS ELISA for the detection of CspB protein Catalog number: PSP 35500

Oct 1, 2002 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of FINE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified)

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

Bt-Cry2Ab and Bt-Cry3Bb1 Multi-trait ELISA Kit DAS ELISA for the detection of Bt-Cry2Ab and Bt-Cry3Bb1 proteins Catalog number: PSM 26800

Tissue-Plus. User Manual. O.C.T. Compound. Optimal Cutting Temperature Embedding Medium for Frozen Tissue Specimens

Detection of Micro-organisms in Compressed Gases

[USING THE VITROBOT April 9, Using the Vitrobot

ASPHALT PLANT LEVEL 1

Ocular Irritation: Dilution Method

Patients Guide for Self Administering Intravenous Antibiotics General points

R2S Standard Sampling Assembly OPERATION PROCEDURE

Version BA D

A Perspective on Filter Cartridge Issues

SuperClear 15mL and 50mL Centrifuge Tubes

EMT EnvironmentalMonitoringTECHNOLOGIES

EcoCell Vertical Electrophoresis Unit

HUMAN IL6 KITS PROTOCOL

Ripple Tank P CONTENTS: DEMONSTRATION SETUP INSTRUCTIONS:

CGMP KITS PROTOCOL ASSAY PRINCIPLE

product manual H-4166 & H-4167 Voluvessel

ab IgG1 Human ELISA Kit

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

3M DICHROIC Glass Finishes

biosensis Mouse CXCL10/IP-10 ELISA Kit Protocol

Handle the film very carefully. As with aluminum foil, once creased, the film will remain creased.

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.

The effect of steam treatment on the total viable count, mould and yeast numbers in hay using the Haygain hay steamer.

UltRo Dual Flow Reverse Osmosis Water System

New AQF Filter Polymer Filtration System

Reinforce design of experiments theory Make individual factorial designs and conduct analysis on responses

Applying 3M Graphic Films With Comply Performance

O P E R A T O R S M A N U A L

amchydroflow HP Validation Guide

Damage Control/Luminous Shipboard Markings

96-well Serum/Plasma Fatty Acid Kit Non-Esterified Fatty Acids Detection 500 Point Kit Cat# SFA-5

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

96-well Serum/Plasma Fatty Acid Kit Non-Esterified Fatty Acids Detection 100 point kit Cat# SFA-1

REQUIREMENTS FOR PACKAGING. Wim Renders

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

Setting up and running a column

BODYFENCE. Protection film: APPLICATION GUIDE FPP.FPS.006 A APPLICATION GUIDE BODYFENCE CONTENTS

according ISO 11014/1 and directive 2001/58/EC Print Date Version 1 ; Revision date

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Chemical Spill Clean-up Protocol

Existing Rule Language Compared to Proposed Rule Language

Bacterial retention within a multi-layered absorbent AIRLOCK Technology Single Use Negative Pressure Wound Therapy (snpwt) dressing

ADAM S CUBE 6 PUZZLES IN 1

RayBio Human vwf ELISA Kit

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

Equipment Standard Operating Procedure Greg Allion and Kimberly Appel

STRUCTURED INQUIRY: Investigating Surface Area to Volume Ratio in Cells

WATER QUALITY REPORT 2017

Factor X Human Chromogenic Activity Assay Kit

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

Production of alcohol-based handrub

AN EXCITING NEW CONCEPT MICROBIOLOGY SLIDE STAINER/ CYTOCENTRIFUGE BIOMEDICAL PRODUCTS WESCOR, INC

STEP 1 A. Lay the two Motor Mount Tubes on a flat surface with ends even and Glue them together with White Glue. Allow Glue to set before moving on.

1. Scope: This document describes the procedure for verifying the performance of vaccine vial monitors.


Gas Pressure Probe. Information Sheet. Total Dissolved Gas

BIOCLOSURE SYSTEM ASSEMBLIES

Manual Tissue Microarrayer

RayBio Human TNF-alpha ELISA Kit

Experimental Procedure

Mix ratio (by volume): (base component) (activator component)

Study & Manipulative Training Guide

IN-PLACE DENSITY WAQTC FOP AASHTO T 209 (16)

Barrel Use and Maintenence

Installation Instructions

Imagine... full flexibility linked to high capacity. Tissue-Tek Prisma & Film. Automated Slide Stainer & Coverslipper

Thank you for choosing Xuma.

CTG Certification Protocol -- Version 3.0 SUMMARY

PRODUCT SHEET. Order probe only as RXPROBE02

RESISTANCE OF COMPACTED ASPHALT MIXTURE TO MOISTURE INDUCED DAMAGE (Kansas Test Method KT-56)

275 RID Assembly Instructions

ROHO QUADTRO SELECT CUSHION ADJUSTMENT INSTRUCTIONS

EtO Micro-Dose Sterilization

*Heart* Pom-pom rug. 1, 2, 3... go! Zweigart & Sawitzki GmbH & Co. KG Fronäckerstraße Sindelfingen. - more than 3 hours -

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

TYPICAL UNCURED PROPERTIES

MOLEBIO LAB #1: Microquantity Measurement

Marking films application guide

POOL PLASTER PROBLEMS AND REMEDIES

Mix ratio (by volume): 513K009 (base component) (activator component)

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Imagine... full flexibility linked to high capacity

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

5 year warranty. Comprehensive selection available. Platforms, Flask Clamps, Tube Racks. VWR Shaker Accessories

Transcription:

3M Food Safety 3M Petrifilm Aqua Enterobacteriaceae Count Plate 3M Petrifilm Aqua Yeast and Mold Count Plate Technician Productivity Maximized Interpretation Guide Introducing 3M Petrifilm Aqua Plates for Water Testing, offering four plates to cover your unique testing needs Heterotrophic Count, Coliform Count, Enterobacteriaceae Count and Yeast & Mold Count. 3M Petrifilm Aqua Plates are ideal for testing bottled water.

Interpretation Guide: 3M Petrifilm Aqua Plates for Water Testing The 3M Petrifilm Aqua Plate system brings the convenience of 3M Petrifilm Plate technology to water testing 1. The 3M Petrifilm Aqua Plate s compact, easy-to-use format brings space savings and reduced waste to the laboratory. An independent, third party study 2 indicates 3M Petrifilm Aqua Plates do not perform statistically different from either SMEWW 3 methods or commonly used bottled water testing methods 4. This guide familiarizes you with results on the 3M Petrifilm Aqua Enterobacteriaceae Count Plate and 3M Petrifilm Aqua Yeast & Mold Count Plate. For more information, contact the official 3M Food Safety representative nearest you. 3M Petrifilm Aqua Enterobacteriaceae Count Plate (AQEB) The 3M Petrifilm Aqua AQEB Plate is a sample-ready culture medium system which contains Violet Red Bile (VRB) nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration. 3M Petrifilm Aqua AQEB Plates are used for the enumeration of Enterobacteriaceae in the bottled water industry. On the 3M Petrifilm Aqua AQEB Plate, Enterobacteriaceae will appear as red colonies with yellow zones, red colonies with gas bubbles, or red colonies with yellow zones and gas bubbles. See Page 3 3M Petrifilm Aqua Yeast and Mold Count Plate (AQYM) The 3M Petrifilm Aqua AQYM Plate is a sample-ready culture medium system which contains nutrients supplemented with antibiotics, a cold-water-soluble gelling agent, and an indicator that facilitates yeast and mold enumeration. 3M Petrifilm Aqua AQYM Plates are used for the enumeration of yeast and mold in bottled water industry. See Product Instructions for more information on differentiating yeast and mold colonies. See Pages 4 5 1 3M has not documented the performance of 3M Petrifilm Aqua Plates for water samples other than bottled water. The use and validation of 3M Petrifilm Aqua Plates to test other types of water samples, such as process or rinse water, is at the sole discretion and responsibility of the end user. 2 Q Laboratories, Inc, Cincinnati, OH, USA study comparing 3M Petrifilm Aqua Plate performance vs. reference methods. Study presented at 2011 International Association for Food Protection (IAFP). 3 Standard Methods for the Examination of Waste Water (SMEWW) 9215A6a and 9222E2b 4 SO 6222, ISO 9308-1 2

3M Petrifilm Aqua Enterobacteriaceae Count Plate (AQEB) Negative Plate and Plates with Colonies Figure 1 AQEB plate Count: 0 Observation: Gas bubbles surrounding filter do not indicate microbial growth. See circle for example. Figure 2 AQEB plate with low count Count: 2 cfu Observation: Enterobacteriaceae are identified by the presence of acid (yellow halo) and/or colony-associated gas bubbles. Figure 3 AQEB plate with high count Count: 17 cfu Observation: Red colonies without acid or gas production (circle) are not counted as Enterobacteriaceae. Figure 4 AQEB plate with high count Count: 43 cfu Observation: Colony color can vary from pink to faint tan. Yellow halo and large gas bubbles can be associated with very faint colonies. Red colony not associated with either acid production or gas are not counted as Enterobactereaceae (see circle). 3

Interpretation Guide: 3M Petrifilm Aqua Plates for Water Testing 3M Petrifilm Aqua Yeast and Mold Count Plate (AQYM) Negative Plate and Plates with Colonies Figure 1 AQYM plate Count: 0 Figure 2 AQYM plate with low count Count: 10 cfu Observation: Mold colonies are large with a dark center and diffuse edge. Figure 3 AQYM plate with low count Count: 10 cfu Observation: Note two small, faint colonies. 4

Plates with High Counts Figure 4 AQYM plate with high count Count: 31 cfu Observation: Yeast colonies. Figure 5 AQYM plate with high count Count: 51 cfu Observation: Estimate colony count when molds merge; darker centers can help enumerate colonies. Count colonies partially or totally off of the filter. 5

Reminders for Use 3M Petrifilm Aqua Enterobacteriaceae Count Plate (AQEB) Storage for Plates Hydration Procedure 8 C A Store unopened packages at 8 C ( 46 F). Use before expiration date on package. In areas of high humidity where condensate may be an issue, it is best to allow packages to reach room temperature before opening. B To seal opened package, fold end over and tape shut. Do not refrigerate opened packages. Use 3M Petrifilm Aqua AQEB Plates within one month after opening. C Place 3M Petrifilm Aqua AQEB Plate on a level surface. With the pipette perpendicular to the 3M Petrifilm Aqua AQEB Plate, place hydration diluent onto the center of the bottom film. D Carefully roll top film down to avoid entrapping air bubbles. Do not let top film drop. E With flat side down, place spreader on top film over hydration diluent. F Gently apply pressure on spreader to distribute inoculum or hydration diluent over circular area before gel is formed. Do not twist or slide spreader. Lift spreader. When inoculating with hydration diluent, allow the hydrated plates to remain closed for a minimum of one hour before use. Proceed to step G. Any additional hydrated 3M Petrifilm Aqua AQEB Plates may be stored in a sealed pouch or plastic bag. Protect plates from light and refrigerate at 2 8 C (36 46 F) for up to 7 days. G Following standard procedures for water analysis, membrane filter water sample using a 47mm, 0.45 micron pore size Mixed Cellulose Ester (MCE) filter. H Lift top film. I Place filter in the center of the well. Roll top film down to minimize air bubbles or gaps between the filter and the 3M Petrifilm Aqua AQEB Plate. J Lightly apply pressure to ensure uniform contact of the filter with the gel and to eliminate any air bubbles. Incubation Interpretation K Incubate 3M Petrifilm Aqua AQEB Plates in a horizontal position, clear side up, in stacks on no more than 20 plates at 34 37 for 24 ± 2 hours. L 3M Petrifilm Aqua AQEB Plates can be counted on a standard colony counter or other illuminated magnifier. Refer to the Interpretation Guide section when reading results. M Colonies may be isolated for further identification. Lift top film and pick the colony from the gel. 6

3M Petrifilm Aqua Yeast and Mold Count Plate (AQYM) Storage for Plates 8 C A Store unopened packages at 8 C ( 46 F). Use before expiration date on package. In areas of high humidity where condensate may be an issue, it is best to allow packages to reach room temperature before opening. B To seal opened package, fold end over and tape shut. Do not refrigerate opened packages. Use 3M Petrifilm Aqua AQYM Plates within one month after opening. Inoculation or Hydration Procedure C Following standard procedures for water analysis, membrane filter water sample using a 47mm, 0.45 micron pore size Mixed Cellulose Ester (MCE) filter. D Place filter in the center of bottom film. E With the pipette perpendicular to the 3M Petrifilm Aqua AQYM Plate, place 1mL of sample or hydration diluent onto the center of the filter. F Carefully roll top film so that it contacts the sample or hydration diluent and then drop the top film. G Lightly apply pressure to the Yeast and Mold Spreader to ensure uniform contact of the filter with the gel and to eliminate any air bubbles. Incubation Interpretation H Incubate 3M Petrifilm Aqua AQYM Plates in a horizontal position, clear side up, in stacks on no more than 20 plates at 20 25 C for 3 5 days. At day 5, additional colonies may be visible. I 3M Petrifilm Aqua AQYM Plates can be counted on a standard colony counter or other illuminated magnifier. Refer to the Interpretation Guide section when reading results. J Colonies may be isolated for further identification. Lift top film and pick the colony from the gel. 7

3M Food Safety offers a full line of products to accomplish a variety of your microbial testing needs. For more product information, visit us at www.3m.com/foodsafety. 3M Food Safety 3M Center Building 275-5W-05 St. Paul, MN 55144-1000 USA 1-800-328-6553 www.3m.com/foodsafety 3M Canada Post Office Box 5757 London, Ontario N6A 4T1 Canada 1-800-364-3577 3M Europe & MEA 3M Deutschland GmbH Carl-Shurz Strasse 1 D41453 Neuss/Germany +49-2131-14-3000 3M Latin America 3M Center Bldg 275-5W-05 St. Paul, MN 55144-1000 USA 1-651-737-2239 3M Asia Pacific No 1, Yishun Avenue 7 Singapore, 768923 65-64508869 3M and Petrifilm are trademarks of 3M. Please recycle. Printed in U.S.A. 3M 2011. All rights reserved. 70-2009-9450-0 (21.3)ii

3M Food Safety 3M Petrifilm Aqua Heterotrophic Count Plate 3M Petrifilm Aqua Coliform Count Plate Technician Productivity Maximized Interpretation Guide Introducing 3M Petrifilm Aqua Plates for Water Testing, offering four plates to cover your unique testing needs Heterotrophic Count, Coliform Count, Enterobacteriaceae Count and Yeast & Mold Count. 3M Petrifilm Aqua Plates are ideal for testing bottled water.

Interpretation Guide: 3M Petrifilm Aqua Plates for Water Testing The 3M Petrifilm Aqua Plate system brings the convenience of 3M Petrifilm Plate technology to water testing 1. The 3M Petrifilm Aqua Plate s compact, easy-to-use format brings space savings and reduced waste to the laboratory. An independent, third party study 2 indicates 3M Petrifilm Aqua Plates do not perform statistically different from either SMEWW 3 or ISO 4 bottled water testing reference methods. This guide familiarizes you with results on the 3M Petrifilm Aqua Heterotrophic Count Plate and 3M Petrifilm Aqua Coliform Count Plate. For more information, contact the official 3M Food Safety representative nearest you. 3M Petrifilm Aqua Heterotrophic Count Plate (AQHC) The 3M Petrifilm Aqua Heterotrophic Count (AQHC) Plate is a sample-ready culture medium system which contains Standard Methods nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration in the bottled water industry. Count all red colonies on 3M Petrifilm Aqua AQHC Plates regardless of size or color intensity. See Pages 3 5 3M Petrifilm Aqua Coliform Count Plate (AQCC) The 3M Petrifilm Aqua AQCC Plate is a sample-ready culture medium system which contains Violet Red Bile (VRB) nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration. 3M Petrifilm Aqua AQCC Plates are used for the enumeration of coliforms in the bottled water industry. On 3M Petrifilm Aqua AQCC Plates, coliform colonies are indicated by red colonies associated with gas. See Pages 6 7 Low number of colonies with gas bubbles 1 3M has not documented the performance of 3M Petrifilm Aqua Plates for water samples other than bottled water. The use and validation of 3M Petrifilm Aqua Plates to test other types of water samples, such as process or rinse water, is at the sole discretion and responsibility of the end user. 2 Q Laboratories, Inc, Cincinnati, OH, USA study comparing 3M Petrifilm Aqua Plate performance vs. reference methods. Study presented at 2011 International Association for Food Protection (IAFP). 3 Standard Methods for the Examination of Waste Water (SMEWW) 9215A6a and 9222E2b 4 SO 6222, ISO 9308-1 2

3M Petrifilm Aqua Heterotrophic Count Plate (AQHC) Negative Plate and Plates with Colonies on Filters Figure 1 AQHC plate with filter Count: 0 Figure 2 AQHC plate with low count on filter Count: 8 cfu Observation: Count all colonies regardless of their size or color intensity. Figure 3 AQHC plate with high count on filter Count: 24 cfu Observation: Note colony morphology is altered by colony-associated gas production. See circle for example. Figure 4 AQHC plate with high count on filter Count: 71 cfu 3

Interpretation Guide: 3M Petrifilm Aqua Plates for Water Testing 3M Petrifilm Aqua Heterotrophic Count Plate (AQHC) Plates with High Counts on Filters Figure 5 AQHC plate with colonies too numerous to count on filter Observation: Colonies vary in size and color intensity. Figure 6 AQHC plate with colonies too numerous to count on filter 4

Negative Plate and Plates with Colonies 1mL Direct Plate (No Filter) Figure 7 AQHC plate Count: 0 Figure 8 AQHC plate with high count Count: 64 cfu Observation: Count all colonies regardless of their size or color intensity. Figure 9 AQHC plate with colonies too numerous to count Count: estimate 10 3 cfu Observation: Determine the average number of colonies in one square (1cm 2 ) and multiply it by 20 to estimate the total count per plate. 5

Interpretation Guide: 3M Petrifilm Aqua Plates for Water Testing 3M Petrifilm Aqua Coliform Count Plate (AQCC) Negative Plate and Plates with Colonies on Filter Figure 1 AQCC plate with filter Count: 0 Observation: Gas bubbles surrounding filter do not indicate microbial growth. See circle for example. Figure 2 AQCC plate Count: 0 cfu Observation: Red colonies without closely associated gas bubbles may be coliforms and should be picked and tested with appropriate confirmation methods. Figure 3 AQCC plate with low count on filter Count: 3 cfu Observation: Coliforms produce acid (faint pink halo associated with colonies) and are associated with gas bubbles. 6

Plates with High Counts on Filter A C B Figure 4 AQCC plate with high count on filter Count: 10 cfu Figure 5 AQCC plate with high count on filter Count: 30 cfu Observation: Gas bubbles influence colony morphology: Coliform distorted by gas bubble (circle A ); faint colony underneath gas bubble (circle B ). Note large artifact gas bubble in the center of the plate (circle C ). 7

Reminders for Use 3M Petrifilm Aqua Heterotrophic Count Plate (AQHC) Storage for Plates 8 C A Store unopened packages at 8 C ( 46 F). Use before expiration date on package. In areas of high humidity where condensate may be an issue, it is best to allow packages to reach room temperature before opening. Inoculation or Hydration Procedure B To seal opened package, fold end over and tape shut. Do not refrigerate opened packages. Use 3M Petrifilm Aqua AQHC Plates within one month after opening. C Place 3M Petrifilm Aqua Plate on a level surface. With the pipette perpendicular to the 3M Petrifilm Aqua AQHC Plate, place 1mL of sample OR hydration diluent onto the center of the bottom film. D Carefully roll top film down so that it contacts the sample or hydration diluent and then drop the top film. E With ridge side down, place spreader on top film over inoculum or hydration diluent. F Gently apply pressure on spreader to distribute inoculum or hydration diluent over circular area before gel is formed. Do not twist or slide spreader. Lift spreader. When direct plating a sample, wait a minimum of one minute for gel to solidify. Proceed to step J. When inoculating with hydration diluent, allow the hydrated plates to remain closed for a minimum of one hour before use. Proceed to step G. Any additional hydrated 3M Petrifilm Aqua AQHC Plates may be stored in a sealed pouch or plastic bag. Protect plates from light and refrigerate at 2 8 C (36 46 F) for up to 14 days. IMPORTANT If you are direct plating, skip to step J. If you are using a 3M Petrifilm Aqua AQHC Plate with a filter, proceed to step G. 8

Inoculation Steps for Plates with Filters G Following standard procedures for water analysis, membrane filter water sample using a 47mm, 0.45 micron pore size Mixed Cellulose Ester (MCE) filter. H Lift the top film. Place filter in the center of the hydration area, grid side up. Roll top film down to minimize air bubbles or gaps between the filter and the 3M Petrifilm Aqua AQHC Plate. I Lightly apply pressure to ensure uniform contact of the filter with the gel and to eliminate any air bubbles. Incubation J Incubate 3M Petrifilm Aqua AQHC Plates in a horizontal position, clear side up, in stacks on no more than 20 plates: Plate with Filter Procedure: 35 ± 2 C for 48 ± 3 hours Direct Plate Procedure: 22 ± 2 C for 68 ± 4 hours or 36 ± 2 C for 44 ± 4 hours Interpretation K 3M Petrifilm Aqua AQHC Plates can be counted on a standard colony counter or other illuminated magnifier. Refer to the Interpretation Guide section when reading results. L Colonies may be isolated for further identification. Lift top film and pick the colony from the gel. 9

Reminders for Use 3M Petrifilm Aqua Coliform Count Plate (AQCC) Storage for Plates 8 C A Store unopened packages at 8 C ( 46 F). Use before expiration date on package. In areas of high humidity where condensate may be an issue, it is best to allow packages to reach room temperature before opening. B To seal opened package, fold end over and tape shut. Do not refrigerate opened packages. Use 3M Petrifilm Aqua AQCC Plates within one month after opening. Hydration Procedure C Place 3M Petrifilm Aqua AQCC Plate on a level surface. With the pipette perpendicular to the 3M Petrifilm Aqua Plate, place hydration diluent onto the center of the bottom film. D Carefully roll top film down to avoid entrapping air bubbles. Do not let top film drop. E With flat side down, place spreader on top film over hydration diluent. F Gently apply pressure on spreader to distribute inoculum or hydration diluent over circular area before gel is formed. Do not twist or slide spreader. Lift spreader. Allow the hydrated plates to remain closed for a minimum of one hour before use. Proceed to step G. Any additional hydrated 3M Petrifilm Aqua AQCC Plates may be stored in a sealed pouch or plastic bag. Protect plates from light and refrigerate at 2 8 C (36 46 F) for up to 7 days. 10

G H Following standard procedures for water analysis, membrane filter water sample using a 47mm, 0.45 micron pore size Mixed Cellulose Ester (MCE) filter. Lift top film. I Place filter in the center of the well. Roll top film down to minimize air bubbles or gaps between the filter and the 3M Petrifilm Aqua AQCC Plate. Incubation J Lightly apply pressure to ensure uniform contact of the filter with the gel and to eliminate any air bubbles. K Incubate 3M Petrifilm Aqua AQCC Plates in a horizontal position, clear side up, in stacks on no more than 20 plates at 35 ± 1 C for 24 ± 2 hours or 36 ± 1 C for 24 ± 2 hours. Interpretation L 3M Petrifilm Aqua AQCC Plates can be counted on a standard colony counter or other illuminated magnifier. Refer to the Interpretation Guide section when reading results. M Colonies may be isolated for further identification. Lift top film and pick the colony from the gel. 11

3M Food Safety offers a full line of products to accomplish a variety of your microbial testing needs. For more product information, visit us at www.3m.com/foodsafety. 3M Food Safety 3M Center Building 275-5W-05 St. Paul, MN 55144-1000 USA 1-800-328-6553 www.3m.com/foodsafety 3M Canada Post Office Box 5757 London, Ontario N6A 4T1 Canada 1-800-364-3577 3M Europe & MEA 3M Deutschland GmbH Carl-Shurz Strasse 1 D41453 Neuss/Germany +49-2131-14-3000 3M Latin America 3M Center Bldg 275-5W-05 St. Paul, MN 55144-1000 USA 1-651-737-2239 3M Asia Pacific No 1, Yishun Avenue 7 Singapore, 768923 65-64508869 3M and Petrifilm are trademarks of 3M. Please recycle. Printed in U.S.A. 3M 2011. All rights reserved. 70-2009-9449-2 (21.3)ii