MASS TRANSFER LAB. Make & Model. S. No. Equipment

Similar documents
Gas Absorption Column CAG

3-PHASE HORIZONTAL SEPARATOR UOP30

MEMORIAL UNIVERSITY OF NEWFOUNDLAND Faculty of Engineering and Applied Science FLUID MECHANICS LABORATORY PIPE FRICTION

Prestige Water Equipment Ltd.

1.5 m. 2.4 m. Fig the pressure exerted by the oil on the base of the tank, the force exerted by the oil on the base of the tank.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Prestige Water Equipment Ltd.

Diffusivity in Gases Experiment ver 5.10b

Flexvent. Venting range and dirt separators. Air pots LTA

Diffusivity in Gases Experiment ver 05.10a

OP CHECKLIST FOR 1D CONSOLIDATION LABORATORY TEST

CORESTA RECOMMENDED METHOD Nº 67

NEW PROGRAM! OIL AND GAS TECHNOLOGY PROGRAM

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

Expert Hydrostatic Level Transmitters

EXTRACTS FROM INSTRUCTION MANUAL

Baffles and Traps Cryotrap

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

Flexvent floatvents: reliable and easy to mount

Old-Exam.Questions-Ch-14 T072 T071

GAS ABSORPTION COLUMN UOP7

Series Environmental Chambers

Experiment 13 Molar Mass of a Gas. Purpose. Background. PV = nrt

PHYS 101 Previous Exam Problems

LAB 7. ROTATION. 7.1 Problem. 7.2 Equipment. 7.3 Activities

HYDRAULICS. H89.8D - Hydraulic Bench

17. CARGO MEASUREMENT AND CALCULATION

Chlorinator. MODEL C-731 (Floor Mounted)

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

Glass tube flowmeters Series 2000

Körting Liquid Jet Vacuum Ejectors

MV5: Automated concentration system

mass of container full of air = g mass of container with extra air = g volume of air released = cm 3

Carbon dioxide absorption in a membrane contactor

Slide 1 / What is the density of an aluminum block with a mass of 4050 kg and volume of 1.5 m 3?

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

Experiment (13): Flow channel

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DETERMINING THE LIQUID LIMIT OF SOIL

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

Self-operated Pressure Regulators for special applications

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

EXPERIMENT 8 Ideal Gas Law: Molecular Weight of a Vapor

Long Win s Educational Facilities for Fluid Mechanics

OVERVIEW METCELL SPECIFICATIONS. Lab scale nanofiltration equipment The METcell Range

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

Density of Brass: Accuracy and Precision

Review of the Hall B Gas System Hardware. George Jacobs

CHAPTER 2 EXPERIMENTAL SETUP AND PROCEDURE

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Summary of the MRA LPG Codes of Practice

OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4

Transferring and Storage

Experiment 1 Introduction to Some Laboratory Measurements

LESSON 3.2 Understanding pressure in liquids

F All types of inert gas systems are to comply with the following:

Niltox Breathing Air Purifier Range

Hydrostatics Bench & Fluid Properties

Chlorinator MODEL MK-I

Type , , S2.20 Specialized test procedure Procedure for testing LPG bulk meters using a vapour displacement prover

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Classes at: - Topic: Gaseous State

Enter your parameter set number (1-27)

Digester Processes. 1. Raw Sludge Pumping System

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

8. Now plot on the following grid the values of T (K) and V from the table above, and connect the points.

States of Matter. Q 7. Calculate the average of kinetic energy, in joules of the molecules in 8.0 g of methane at 27 o C. (IIT JEE Marks)

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

"INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project

Trifecta High-Pressure Systems

INDUSTRIAL TRANSFER PUMPS

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl

Irrigation &Hydraulics Department lb / ft to kg/lit.

Permitted MSS Emissions Tracking, Recordkeeping, and Reporting. Presented by ACES April 24, 2008

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

WP2 Fire test for toxicity of fire effluents

THE GAS STATE. Unit 4. CHAPTER KEY TERMS HOME WORK 9.1 Kinetic Molecular Theory States of Matter Solid, Liquid, gas.

Cover Page for Lab Report Group Portion. Pump Performance

Experiment #2. Density and Measurements

IMPERIAL CHEMICAL INDUSTRIES LIMITED PETROCHEMICAL DIVISION. SAFETY NEWSLETTER No. 55

PTFE-SINGLE GLASS FLOW METERS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Ch. 11 Mass transfer principles

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

The number of test stands can be adapted to the special requirements.

Air Operated Hydraulic Pumping Systems to 50,000 psi

Unit 2 Kinetic Theory, Heat, and Thermodynamics: 2.A.1 Problems Temperature and Heat Sections of your book.

490 Micro GC Site Preparation Checklist

Grit chambers are basin to remove the inorganic particles to prevent damage to the pumps, and to prevent their accumulation in sludge digestors.

776 Cryogenic Safety Valve

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Drass. 700 Series Surface Diving System

CTB3365x Introduction to Water Treatment

Unit 24: Applications of Pneumatics and Hydraulics

Cryostream 800 Series

BASIC PHYSICS APPLIED TO ANAESTHESIOLOGY

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

Measurements of k L a. Steady-State Mass Balance Method:

Transcription:

MASS TRANSFER LAB S. No. Equipment Make & Model Manufacture Qty 1 Liquid / Liquid Extraction Unit UOP5-A Armfield 1 2 Gas Liquid Absorption UOP7-A Armfield 1 3 Diffusion of a Liquid Apparatus CER A-A Armfield 1 4 Gaseous Diffusion Coefficient Apparatus CER B Armfield 1

LIQUID/LIQUID EXTRACTION UNIT Liquid/liquid extraction is a valuable process in chemical engineering where the separation of one or more of the components from a liquid mixture is required. The Armfield UOP5 unit demonstrates this process in the laboratory so that students may gain a thorough understanding of this industrial technique. Meaningful experiments may be conducted within a two hour laboratory period and students benefit from visual observation of the process.

SERVICES REQUIRED Electrical supply: UOP5-A: 220-240V/1ph/50Hz UOP5-B: 120V/1ph/60Hz UOP5-G: 220V/1ph/60Hz Cold water supply: mains pressure Vapour extraction system OVERALL DIMENSIONS Height: 2.5m Length: 1.30m Depth: 0.75m SPECIFICATION Volume: 3.3m3 Gross weight: 380kg

GAS LIQUID ABSORPTION COLUMN The Armfield Gas Absorption Column has been designed to demonstrate the principles of gas absorption and to provide practical training in the operation of gas absorption plant. The packed absorption column is made up of two 75mm diameter borosilicate glass sections joined end to end and installed vertically on a mild steel floor standing framework. The column is filled with 10mm x 10mm Raschig rings, also glass, which are representative of the type of packing used in gas absorption. Liquid for the process is stored in a 50.0 litre rectangular feed tank and a centrifugal pump is used to deliver the liquid to the top of the column where it falls through the packing and returns to the tank. A variable area flow meter in the recirculation line gives a direct reading of flow rate. TECHNICAL DETAILS Feed tank capacity: 50.0 litres Diameter of column: 0.075m Volume of packing: 7.0 litres Height of absorptioncolumn: 1.4m Type of packing: Raschig rings 10x10mm Air compressor capacity: 0.15m3/min@0.3bar Column feed pump capacity: Air flow meter range: 20-180 l/min Gas flow meter range: 1.0-22.0 l/min

Water flow meter range: 1.0-10.0 l/min SERVICES REQUIRED Electrical supply: UOP7-A: 220-240V/1ph/50Hz UOP7-B: 120V/1ph/60Hz UOP7-G: 220-240V/1ph/60Hz Initial water fill ESSENTIAL ANCILLARY EQUIPMENT CO 2 Cylinder with pressure regulator RECOMMENDED ANCILLARY EQUIPMENT Vent piping to outside laboratory Titration glassware for liquid analysis Separate drain tank for treatment of effluent OVERALL DIMENSIONS Height: 2.53m Width: 0.90m Depth: 0.65m SPECIFICATIONS Volume: 2.0m 3 Gross weight: 220kg

MASS TRANSFER AND DIFFUSION COEFFICIENTS CERa/CERb Two separate items of laboratory equipment have been designed to allow measurement of molecular diffusivities and, in so doing, to familiarise students with the basic notions of mass transfer theory. The gaseous diffusivity apparatus (CERa) involves diffusion with bulk flow, whilst the liquid diffusivity apparatus (CERb) relates to an equi-molar counter-diffusion process. CERa Gaseous Diffusion Coefficients Apparatus The diffusion of a vapour A from a volatile liquid into another gas B can be conveniently studied by confining a small sample of the liquid in a narrow vertical tube, and observing its rate of evaporation into a stream of gas B passed across the top of the tube. CERb Liquid Diffusion Coefficients Apparatus

Armfield has developed a unique diffusion cell which overcomes the traditional problem of slow diffusion rates in liquids requiring long observation times, but without sacrificing accuracy or introducing convective effects. Essentially, the cell consists of a honeycomb of accurately dimensioned capillaries, positioned between two liquids of differing concentration of the solute whose diffusion coefficient is to be determined. SERVICES REQUIRED Electricity supply: CERa-A: 220-240V/1ph/50Hz CERa-B: 120V/1ph/60Hz CERb: Battery operated OVERALL DIMENSIONS CERa Gaseous Diffusion Coefficient Apparatus Height: 355mm Width: 450mm Depth: 390mm CERb Diffusion Apparatus Height: 310mm Diameter: 190mm Conductivity Meter Height: 130mm Width: 150mm Depth: 250mm SPECIFICATION CERa: Volume: 0.20m3 Gross Weight: 30kg CERb: Volume: 0.10m3 Gross Weight: 10kg