HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

Similar documents
Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Laser Gas Analyzer LG2000. The Laser Technologies

FT-IR solutions for laboratory and process gas phase measurements R&D, QA/QC, process optimization and air monitoring

FOURIER TRANSFORM INFRARED SPECTROSCOPY

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

FTIR Users Group Meeting FTIR development

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Overcoming Common Gas Sampling Challenges

MB3000-CH90 and MBGAS-3000CH FT-IR solutions for laboratory and process gas phase measurements R&D, QA/QC, process optimization and air monitoring

LFE OEM TCD - Thermal Conductivity Detector

Purpose and Scope: Responsibilities: Warnings and precautions: Background Beers law

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

CALIBRATION. empanelled laboratories following standard procedures and using certified reference standards.

Dr. Tetsuzo KITAGAWA, Tokihiko YONEDA, Shigefumi NAKAJIMA. 1. Preface

Application Note AN-107

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Alphasense Application Note AAN NDIR: Gas Concentration Calculation Overview

SM8200. SO2/NO In Situ Multi-Gas Analyzer

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Columbus Instruments

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

APPENDIX C. 40 CFR PART 60 App. B SPEC. 1-4, 6

Online DGA-monitoring of power transformers

S on equipment and pipelines along with the constant threat to personnel safety justify major investment in H 2

A Coal Mine Multi-Point Fiber Ethylene Gas Concentration Sensor

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

TGA100A Trace Gas Analyzer Overview

ABB MEASUREMENT & ANALYTICS DATA SHEET. Advance Optima AO2000 Series Continuous gas analyzers

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

What I have learned about SF 6 gas testing.a Practical explanation

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT METHOD INSTRUMENTAL ANALYZER PROCEDURES FOR CONTINUOUS GASEOUS EMISSION SAMPLING

Datasheet: K-30 ASCII Sensor

Analytical Application Sets Continuous emission monitoring

METHOD 3A - DETERMINATION OF OXYGEN AND CARBON DIOXIDE CONCENTRATIONS IN EMISSIONS FROM STATIONARY SOURCES (INSTRUMENTAL ANALYZER PROCEDURE)

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

MMS Mercury Monitoring System for Natural Gas

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Sr. No. General points CPCB Comments 1. Print option, acknowledgement of submission for CPCB OCEMS Protocol

White Paper. Gas Analysis Made Easy Plug and Play Tunable Diode Lasers INGOLD

Gravimetric preparation of NO 2 primary reference gas mixtures at the NMISA. Tshepiso Mphamo 03 September 2012

Autocalibration Systems for In Situ Oxygen Analyzers

8.1 Calibration of gas sensors

Sensepoint XCD. Calibration Guide

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Data Sheet 10/ EN July 2007

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Protocol Gas Verification Program (PGVP)

Standard Operating Procedure for H 2 S and SO 2 Converter

PRODUCT CONFORMITY CERTIFICATE

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

EasyLine Continuous Gas Analyzers. So smart, they re simple

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Advance Optima AO2000 Series Continuous gas analyzers Models AO2020, AO2040. Measurement made easy. Modular continuous gas analyzers

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

Autocalibration Systems For In Situ Oxygen Analyzers

Thermo Scientific Model 146i Principle of Operation

Mid-IR Lasers Market Review and Forecast 2010

Environmental Technology Verification Report

ABB MEASUREMENT & ANALYTICS DATA SHEET. EasyLine EL3000 Series Continuous gas analyzers

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

UT 3000 Mercury Ultratracer

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Technical Paper. Selection of Particulate Monitors. Author: William Averdieck, PCME Ltd

SAF WATER LEAK DETECTION BY THE MEASUREMENT OF GASEOUS WATER VAPOUR

SEC Signature DIR Process Monitor

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.


3. Coupled Techniques in Thermal Analysis

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

Innovative gas and outgassing analysis and monitoring

Pool and Spa. Water Testing

FLOWSIC100 Flare Challenges in Ultrasonic Flare meter field installations. History of Evolution

Best Practice for Calibrating LTH Conductivity Instruments

General Specifications

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

Generating Calibration Gas Standards

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

APTI 464. Analytical Methods for Air Quality Standards. Laboratory Exercise Manual. March 2010

Best Practice Guide, Servomex 2700

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Level MEASUREMENT 1/2016

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Model EXAxt AV550G. Averaging Oxygen Analyzer

Flow metering in gases Introduction to COMBIMASS family

Transcription:

HCL MONITORING ICAC MARAMA WORKSHOP May 18-19th, 2011 Presented by: Ty Smith. CEMTEK 1

HCL MONITORING Applications Existing Measurement Technologies New Technologies Calibration and issues 2

APPLICATION EMISSION REQUIREMENTS CEMENT : Fuel type- coal, biomass, gas. MACT Limit 3ppmvd@7%O2 Requires CEMS UTILITY : Fuel type - Coal Proposed MACT Limit 0.2 lbs/mmbtu Will Require CEMS WASTE INCINERATION: Fuel Type - Biomass SIP Emission Limit 29ppmvd@7%O2 (for affected facilities) May require CEMS, based on source. 3

Application Requirements WET SAMPLING: Most applications and measurement methods require the use of wet sampling to avoid any issues that may compromise the sample When measuring a hot wet sample it prevents errors due to absorption, desorption effects from HCl on the wetted parts. Keep the entire sample train hot/insulated to prevent cold spots Conventional Hot/wet systems require sample components be kept at a minimum of 185 o C to prevent cold spots. Low pressure sample systems should be kept above 50 C. Standard hot/wet systems sample at high temperature and high flow rate. This shortens the time the sample is in contact with the system components, minimizing memory effects. Low pressure sample systems require no sample conditioning or moisture removal. 4

Concerns Problems associated with Acid Gases: The sample has to be maintained above acid dew point (normally 140-150 o C) Chlorides not removed in the particulate filter can cause interference problems. NH3 can cause interference. Biggest problem with stability is keeping moisture from reaching the gas. N2 purge on the pressure side is recommended to insure that ambient H2O does not mix with the gas. 5

MEASUREMENT TECHNIQUES FTIR: Fourier Transform IR NDIR: Non Dispersive IR ---------------------------- TDL: Tunable Diode Laser - Cross Duct Extractive Type - Optical Feedback Laser 6

MEASUREMENT TECHNIQUES FTIR: Fourier Transform IR Technique utilizes a moving mirror in an interferometer to generate an interferogram of the sample absorption spectrum Performing a mathematical Fourier transform on the interferogram generates a single beam spectrum. The single beam spectrum must be routinely ratioed against a zero gas single beam spectrum to compensate for drift & linearize instrumental response. FTIR can generate multi-component measurement results, including HCl. Hot wet sample system Internal gas cell available. Typical minimum range for HCl: 0-10ppm 7

Measurement Technique What is Fourier Transform Infrared Spectroscopy (FTIR)? Measurement technique collects all of the infrared spectral data at once. A broadband IR light is sent through the interferometer (modulator) which modulates all of the light wavelengths at once. Once modulated, the signal is passed through the gas cell where various molecules absorb some of the light. The measured signal is demodulated, using the Fourier Transform process, which converts the mirror position into a frequency response that is directly related to the molecules present in the gas sample.

Measurement Technique Fourier Transform Infrared (FTIR) Data Analysis The demodulated signal (interferogram) is converted via the Fast Fourier Transform (FFT) to a single beam spectrum. To remove the FTIR instrument response, a non-ir absorbing gas is passed through the gas cell prior to flowing the sample. This instrument response is removed from the sample signal during the sample process. A logarithmic ratio of the sample beam to the background beam produces the final Absorbance signal over the IR spectrum and contains the response of all compounds that are IR active. The height of the Absorbance peak is directly related to the concentration.

Measurement Technique NDIR: Non-dispersive or filter-based IR systems utilize either the Dual Wavelength / Filter or Gas Filter Correlation (GFC), Cross Flow Modulation techniques to measure gas components. For HCL, GFC is the technique of choice for some CEMS suppliers both sample and reference filters are swung into the light path. In the case of the reference filter, typically nitrogen,or some other gas with no absorbance in the IR region, is passed through the gas cell, leaving a baseline background for comparison. Then the sample gas is run through the gas cell and the sample filter is swung into the light path allowing only a narrow band of light at a specific wavelength region to pass through to the detector, measuring the absorption of the gas that is specific for that filter in question. The background interference is eliminated by ratioing the sample absorbance to that of the reference (N2) absorbance, as they are present in both spectrum. The NDIR can monitor additional gases such as NO, NO2, CO2, CO, SO2 and others by the application of multiple filters tuned to those compounds, providing a more versatile analysis instrument.

Measurement Technique NDIR GAS FILTER CORRELATION Typical GFC configuration 11

HOT WET SAMPLING Sick MCS-100. HCl module can be added to existing systems. Similar to other NDIR systems. 12

Are there other options? Yes there are! 13

Can We Do Better? We don t believe that existing FTIR & NDIR analyzer systems are able to accurately measure the low levels HCl that the rules will require. What other options are available? Can these newer analyzers be more accurate, require less maintenance and still be cost effective? Accurate analyzers are needed to maximize effectiveness of scrubbing systems and reduce the amount of scrubber media required. 14

What are the options? Option 1: Cross Duct TDL s Utilize existing TDL technology used for NH3 and other gasses to measure HCl. Several successful installations measuring less than 2ppm HCl. How do they work? 15

Tunable Diode Laser Measurement Technique Measurement method Very accurate method for measuring emissions of HCL. Several different configurations offer flexibility depending on application. Across Stack Analyzer: non contact sampling, measures flue gas in its natural condition Purge air or blowers to keep optics clean. Shorter path lengths required in high particulate applications. No Zero Drift. Built in Span Calibration Cell. 16

Tunable Diode Laser Measurement Technique How do Tunable Diode Lasers (TDL) Operate? Laser center wavelength depends on composition of crystal Laser wavelength can be changed over narrow range by changing current or over a wider range by changing laser operating temperature By temperature controlling the laser, changing the electric current permits scanning over entire absorption feature By scanning the entire absorption feature, interference from dust is eliminated as the laser signal power is continuously measured.

Across Stack TDL Analysis DUCT Fiber-optic & coax cables Analyzer

Across Stack TDL Analysis CALIBRATION Internal Calibration Cells 19

Daily Calibration: Across Stack TDL Analysis Calibration Capabilities: Calibration check using Internal Cal Cell. Checks Zero by analyzing background signal Span Cal value typically 20ppm Timing controlled by Analyzer Additional Calibration Verification Option: Calibration using Inline Flow Thru Cell Zero Air purge for cell to ensure no false indication, Zero check as per daily cal check Span gas flow thru (approx 8 minutes, 3 for stabilization, 5 for detection) 20

SECOND OPTION Optical Feedback Cavity Enhanced Absorption Spectroscopy. The challenge was developing a sampling method that would allow this technology to be used in almost any application. This lead to Patented Low Pressure Sampling Technology being used from probe to analyzer. No sample conditioning required. No interference from other gasses or moisture. 21

CEMTEK OFL-CEM for HCl 22

Extractive OFL-CEM Analyzer Utilizing the latest advancements in Scanning Laser Analyzer technology. Optical Feedback improves analytical performances in terms of accuracy, stability & sensitivity. Up to 20 KM path length allows for PPM, PPB & in some cases PPT measurements. Optical Feedback stabilizes the spectrometer by monitoring & compensating for source variations in the optical system & monitoring in real time (10Hz) the output signal of the spectrometer to automatically correct for any drift. 23

OFL-CEM Analyzer Optical Feedback improves laser accuracy 100x, reducing noise & interference & increases sensitivity by 1,000 x over standard metric gas cells by increasing path length a thousand fold. Low pressure sampling in the gas cell narrows the absorption bands to a point where no spectral overlapping occurs. Range of 0-3ppm with 30 ppb accuracy 24

Low pressure sampling probe 25

Optical Feedback Cavity Enhanced Absorption Spectroscopy + Low Pressure Sampling for HCl (g) Measurement A Scanning TDL or QCL - 200 data points spectra @ 1 picometer resolution B Hyper-Reflective Gas Cell - up to 20km path length equivalent C Detector - high speed - (100 msec. scan) High MTBF D Beam splitter - Rugged, non-hygroscopic optics E Detector - high MTBF F Sampling Probe - low flow rate, low fouling sonic nozzle G Vacuum Pump - cost effective, low maintenance 26

LOW PRESSURE SAMPLING 1 Laser - Multiple Gases (50 mbar 45 C 10 km 50-100 mbar Patented LPS sampling 10% H2O 1ppm HCL 10% H2O NO 1000PPM No Spectral Overlapping (@ 50-100 mbar) = No Possible Cross Response / Interference Can be used to measure H2O, NO, CO, CO2, H2S, NH3, SO3, CH4, N2O, CO3, O3, Methanol's etc. 27

LOW PRESSURE SAMPLING Lowering the pressure of a gas sample therefore also reduces the dew point of all chemicals present. A flow rate of 3 l/h results in extremely low fouling est. 4g deposit over a 12 month period. Because H2O remains in gas phase there is no spectrally overlapping, unlike in most FTIR s where spectral overlapping can occur. Additional particulate filters ensure that the gas cell remains clean. 28

CALIBRATIO N Self-referencing spectrometer No zero gas required Zero Reference Information is contained in the signal itself. Raw Spectrum Calibration Method: Beer- Lambert s Law Can be verified with calibration gas at the probe tip or directly into the analyzer. N.I.S.T Traceable direct measurement. I 0 (ZERO) I (conc.) 0.00112nm 0.005cm-1 29

CALIBRATION Calibration Gas Requirements: Keep Calibration gas cylinders and associated hardware dry Cylinders should have nickel coating on the walls Pressure regulators must be nickel lined stainless steel, No protocol gas at present. EPA & manufacturers in discussion on this. Cylinders available in the range of 10ppm and higher. Keep all moisture out of regulator & cal lines. 30

CALIBRATION Calibration Gas Issues: Biggest issue is moisture in the sample and sample line. Sample temperature should be maintained above 180C, for FTIR & NDIR Systems. Should be kept above 50 C for OFL-CEM Systems. Keep Calibration gas cylinders and associated hardware dry The OF-CEAS analyzer system eliminates the typical calibration issues of instability. Recommend using silica coated probes and silica coated stainless steel tubes for sample & calibration gas.. 31

QUESTIONS? Thank you for your time this morning, for more information contact: Ty Smith President CEMTEK GROUP Ph: (908) 474-9630 ty@cemteks.com Acknowledgements to: Dan Kietzer - Sick Optics Alak Chandra Unisearch Lucien Lonigro AP2E Bertrand Lahner Sensors Inc. Ken Greaves National Sales Manager CEMTEK INSTRUMENTS Ph: (215) 290-4593 kgreaves@cemteks.com 32