Accu-Tab PowerBase 3012AT by Axiall Corporation

Similar documents
Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab PowerBase 3070AT by Axiall Corporation

Accu-Tab PowerBase 3140AT by Axiall Corporation

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

ECONOMY POOL SUNSHINE IONIZER MODEL SPE INSTALLATION INSTRUCTIONS

Operator's Manual. Model #PS Arch Chemicals, Inc Lake Park Drive Smyrna, GA PULSAR

Arch Feeder: Operator s Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

PURITY INSTALLATION INSTRUCTIONS MODEL P40

Installation Instructions JATCO Environmental Protection Tank Model J-7000

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

Vessel Installation and Operating Manual

There are no NSF-certified substitutes for Accu-Tab 3-inch Blue and Blue SI (scale inhibitor) Tablets.

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Installation and Operating Instructions

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

1. Introduction Part One The business... 2 Part Two The benefits... 3

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Installation and Operating Manual

FLANGED TWO-PIECE BALL VALVES

J Air and Water Kit Instructions Part# 02584

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

FLANGED TWO-PIECE BALL VALVES

INSTALLATION AND OPERATION INSTRUCTIONS

PC1131 Electric Air Compressor

453 Series Steam Heated Vaporizing Regulator

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

FLANGED MULTI-PORT BALL VALVES

INSTALLATION AND OPERATION INSTRUCTIONS

PERSONAL AIR BREATHING UNIT

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

ACCU-MIX 1200 / / 26270

BS Series Basket Strainer

RAM 4021 Operation Manual

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

RG2200 BC Integrated Octopus

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Cocoa Patio Pond with Lit Spillway

Commercial Well Tank Installation Instructions

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

User Instruction Manual

Modular skylight warranty

Model TWBS.SH Tempered Water Blending System

1 Pound Treats Between 10,000 to 15,000 Gallons. 24 x 1lb. pouches

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

D Series Air and Water Kit Part# 02550

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

ULTRA QUIET & OIL FREE

480C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK

Model Portable Eyewash

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Nitrogen Supply System

4-in-1 Professional Inflator Kit

FloWash. Industrial Filter Cart

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

Installation, Operation and Maintenance Manual

Contact Chamber and PoolMoss Packs

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Yoke Block Instruction Manual

G7S Hand Pump Owner s Manual

SPECIFICATIONS APCEPH1

200 PSI COMPRESSORS - MODEL NUMBERS

Model ASSEMBLY and OPERATING INSTRUCTIONS

SERIES BB TRASH BASKETS

Installation and Operating Instructions

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

92831 TEL: (714) FAX:

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

TITAN FLOW CONTROL, INC.

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

ChlorMaker DO OPERATING INSTRUCTIONS DO - DRAPE OVER

Model 9201E Tempered Water Blending System

200 PSI FAST-FILL AIR SOURCE KIT

IMPORTANT SAFETY INSTRUCTIONS

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

SERVICE BULLETIN This service bulletin is for Accu-Tab Blue Calcium Hypochlorite Tablets (EPA Reg. No )

Portable Compressed CO 2 Regulator

Interface Devices, Inc. Hydraulic Mini Mule

400C & 450C DUAL PERFORMANCE VALUE PACKS

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

2 Gallon Air Compressor

RG3100 and RG3100Ice Regulator System

100C Air Compressor Kit

ASAHI/AMERICA EFFECTIVE: 12/01/08. Dimensional Guide. Halar (E-CTFE) Piping & Valves

Transcription:

Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved tablets only. Do not use Cal-Hypo tablets with stabilized chlorine or bromine products, or other sanitizing chemicals. Fire or explosion could result. Rev 06/11/15

System Description The ACCU-TAB tablet chlorinator system incorporates an Axiall Corporation chlorinator, which is designed to utilize Axiall s ACCU-TAB Blue SI calcium hypochlorite tablets. The chlorinator is mounted on an aluminum frame. Included in the system is an integrated, level controlled solution tank, which supplies a centrifugal pump. Using a manually adjusted valve and flow meter the amount of water through the chlorinator is controlled. This results in a constant and predictable rate of chlorine delivery. Additional water is supplied to the solution tank, with float level control, to assure the pump does not run dry. Overflow protection is standard. Two additional level switches in the top area of the Solution Tank (4 apart) will flip a latching relay in the electrical box causing the pump to turn on/off as needed. The chlorination system is designed for use ONLY with Axiall Accu-Tab Blue SI tablets utilizing the Axiall erosion feeder technology that erodes only the bottom layer of tablets on the sieve plate, while keeping tablets above the sieve plate dry and ready for use. Tablets other than Axiall Accu-Tab Blue SI tablets will have different delivery rates, resulting in improper chlorine delivery. 2

Installation and Start-Up Instructions 1. Uncrate, remove from pallet, and check for damage that may have occurred during shipping. 2. Locate Chlorination System in adequately ventilated area and on level ground. If system is in area subject to standing water, then system should be raised above standing water. Adjust leveling feet as necessary. 3. All systems are tested in full operation at the factory, however fittings may loosen during shipping. Before Installing System, hand-tighten all fittings on pipe unions. 4. Use 1-1/2 minimum piping (2 minimum Model 3140) on the chlorinator inlet and outlet piping to ensure ample supply of water. (Refer to the chart at the end of these instructions for the minimum required system supply water flow rate.) Use isolation valves at main system connections. A check valve MUST be installed on the discharge line from the chlorinator. Inlet Outlet 5. Connect cords to proper power source and controller source. Plugs are labeled. 6. Once the power and water input and output connections are in place, open isolation valves and check for leaks. Supply water will begin filling the tank through the float valve. This will automatically prime the pump. (Any air initially in the pump will vent into the solution tank through the blue prime line.) 3

7. Turn system on using the controller. 8. Open the pump discharge valve slightly to start water flow through system. 9. Open inlet valve and set to desired flow rate. 10. Slowly, and in small increments, continue to open the discharge valve, and adjust inlet valve as necessary to get desired inlet flow. 11. Make incremental changes to the discharge valve until the tank water level drops and stabilizes at approximately ¾ tank level. 12. Turn the system OFF and ON several times, allowing it to operate for several minutes each time. Check all connections for leaks, make sure the delivery pump suction always remains covered with water. 13. To begin chlorinating, remove the chlorinator lid and fill the Chlorinator with ACCU-TAB Blue SI Tablets. 14. Check the system daily for leaks and proper operation of all components. 15. Adjust the flow rate through the chlorinator by adjusting the inlet valve. 4

MINIMUM SUPPLY WATER FLOW REQUIREMENTS Model Minimum supply flow, gpm 3012 AT 15 3070 AT 30 3140 AT 60 Electrical Drawing Base System 5

Operating and Maintenance Instructions A. Solution Tank Leveling (Tank level runs low causing the pump to lose prime) This is caused by the pump moving more water than is fed to the system. This can lead to inconsistent chlorine residuals, and can lead to premature pump motor failure. Follow this procedure to adjust: 1. Slowly, and using small increments, close the pump discharge valve. 2. Make incremental changes to the discharge valve until the tank water level rises and stabilizes, and is approximately at ½ to ¾ tank level. (Tank level runs high causing the solenoid to close) This is caused by either too high a flow through the chlorinator, or the discharge valve is closed too much. Follow the procedure to adjust: 1. Slowly, and using small increments, open the discharge valve. 2. Make incremental changes to the discharge valve until the tank water level drops and stabilizes, and is approximately at ½ to ¾ tank level. 3. If level will not drop, begin reducing the water flow to the chlorinator. If this results in low chlorine residuals, contact PPG Technical Service at 800-245-2974 for assistance. B. Cleaning the chlorination system Over time, and depending on the pool water chemical characteristics, some calcium scale may build up in the system. Following procedure to clean: 1. Prepare 2 gallons of weak acid solution. 2. Open doors and windows for ventilation. 3. Reduce the tablet volume in the chlorinator by operating the system to deplete the tablets. 4. Physically remove any remaining tablets or pieces of tablets. Store in a safe manner (clean pail or surface). 5. Operate the system for 30 minutes to flush out all remaining chlorine solution, and hose down inside of chlorinator walls. 6. Shut down the system, and close isolation valve on line feeding the system 7. Pump tank level down to about ¾ tank if necessary to prevent system from overflowing while adding cleaning acid 8. Close the discharge isolation valve. 9. Turn system on using controller to start flow circulation through tank. 10. Very slowly and carefully pour the weak acid solution into chlorinator. CAUTION: AS ACID DISSOLVES SCALE, CARBON DIOXIDE WILL BE RELEASED, AND FOAMING WILL OCCUR. IF ANY CHLORINE WAS LEFT IN THE TANK OR CHLORINATOR, CHLORINE GAS MAY ALSO BE RELEASED. 11. Operate for 10-15 minutes. 12. Open isolation valves on the inlet and discharge to the system. 13. Be prepared to handle some acid being discharged to the pool. 14. Operate for 30 minutes to flush system, and thoroughly wash out chlorinator with a hose. 15. Switch off. 16. Inspect for any debris in the chlorinator or tank, and remove if found. 17. Add tablets and restart system to resume chlorination. 6

Operating and Maintenance Instructions (Con t) C. Cleaning the chlorination system 1. Clean the system as outlined above once per year 2. Float Valve must be free to move. Disassemble valve and clean. 3. Disassemble Solenoid Valve and clean out debris and make sure small orifices are clear 4. Disassemble Discharge Check Valve and soak in muriatic acid solution if necessary. Operating Troubleshooting Guide A. Tank fills and continuously overflows when system shuts down. 1. Solenoid has failed a. Shut inlet isolation valve to verify that it is the solenoid b. Disassemble the solenoid to check for debris. c. Reassemble the solenoid, and open isolation valve. d. If overflowing continues, replace solenoid valve. 2. Check valve has failed 1. Shut outlet isolation valve to verify that it is the check valve. 2. Disassemble the check valve to check for debris or scale. 3. If scale is present, clean with a dilute acid solution. 4. Reassemble the check valve, and open the isolation valve. 5. If overflowing continues, replace check valve. B. Tank fills and overflows slightly, then stops. 1. Level in the solution tank is too high during operation. Refer to Solution Tank Leveling in the Operating and Maintenance Instructions section of this manual. C. Tank continually runs low level/empty, causing pump to lose prime. 1. Float Valve not operating properly a. Remove solution tank lid and verify that float is free to move up/down. b. If the float is in the up position, and cannot be freed, replace float valve. 2. Inlet solenoid failure a. Check flow rate on flow meter. b. If no flow, then check for power to solenoid valve. c. If no power to valve, check electrical system using electrical schematic. d. If power to valve, close inlet isolation valve, disassemble the solenoid and check for debris. e. If no debris, then solenoid is faulty. f. Replace solenoid valve. 3. Improper tank leveling a. Refer to Solution Tank Leveling in the Operating and Maintenance Instructions section of this manual. D. Contact PPG Technical Service (800-245-2974) for assistance. 7

CAL-HYPO COMERCIAL SYSTEM LIMITED WARRANTY Limited System Warranty Axiall Corporation ("Axiall") warrants (subject to the below conditions) only its title to this water treatment system equipment (the "System") and that the System will be free of defects in materials and workmanship for a period of (12) months from its original installation date. THIS IS THE ONLY REPRESENTATION OR EXPRESS WARRANTY THAT AXIALL MAKES AND ALL OTHER EXPRESS WARRANTIES UNDER STATUTE OR ARISING OTHERWISE IN LAW FROM A COURSE OF DEALING OR USAGE OF TRADE WITH RESPECT TO THE SYSTEM ARE DISCLAIMED. ANY IMPLIED WARRANTIES EXISTING AS A MATTER OF LAW SHALL NOT EXCEED THE DURATION OF THIS LIMITED WARRANTY. IN THE EVENT THE SYSTEM FAILS TO CONFORM TO THIS WARRANTY, AXIALL'S EXCLUSIVE OBLIGATION AND YOUR EXCLUSIVE REMEDY SHALL BE LIMITED TO, AT AXIALL'S OPTION, THE FURNISHING OF NEEDED REPLACEMENT PARTS OR THE FURNISHING OF A NEW SYSTEM (BUT THIS DOES NOT INCLUDE INSTALLATION OR THE COSTS FOR INSTALLATION). EXCEPT AS PROVIDED IN THE IMMEDIATELY PRECEDING SENTENCE, IN NO EVENT WILL PPG BE LIABLE UNDER ANY THEORY OF RECOVERY (WHETHER BASED ON NEGLIGENCE OF ANY KIND, STRICT LIABILITY OR TORT) FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES IN ANY WAY RELATED TO ANY USE MADE OF THE SYSTEM. Warranty Conditions. This Limited Warranty shall apply and be effective only if: (i) the Axiall Chlorinator Warranty Registration information has been completed within thirty (30) days of the customer s receipt of the system via the Internet at www.accu-tab.com; (ii) the System is installed and operated and maintained in accordance with this manual and the instructions accompanying the System; (iii) you, at your cost, promptly return the System or defective part to such location as may be specified by Axiall; and, (iv) only Axiall's ACCU- TAB calcium hypochlorite tablets are used in the System. If any of these conditions are not met, this Limited Warranty will not apply and you acknowledge and agree that your purchase of the System will be on an "AS-IS" basis without any warranty of any kind whatsoever having been provided by Axiall. You assume all responsibility and risk and liability arising from: (i) the unloading, installation, storage, handling and use of the System, including use thereof alone or in combination with other materials; (ii) the improper functioning or failure of unloading, installation, transportation or storage equipment you use, whether furnished or recommended by Axiall or not; and, (iii) the failure to comply with laws, rules and regulations governing storage, unloading, installation, handling, and use of the System. You will indemnify, hold harmless, and defend Axiall from and against any claim, suit, damage, cost, expense, fine, liability, or cause of action whatsoever, including reasonable attorney fees, on account of relating to, or arising out of the use, possession, installation or resale of the System. This Limited Warranty gives you specific rights, and you also may have other rights, which vary from jurisdiction to jurisdiction. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. 8