TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

Similar documents
TBV-CM. Combined control & balancing valves for small terminal units For modulating control

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

TA-FUSION-P. NPT threads / ANSI flanges

STA. Double regulating valves DN 15-50

STAP. Differential pressure controllers DN , ANSI flanges

STAD-C. Balancing valves DN 15-50

STAD. Balancing valves DN 15-50

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

STA. Double regulating valves DN 15-50

TRV-2, TRV-2S. Thermostatic radiator valves With presetting

STAD. Balancing valves DN (MD60, MD61, MD62)

STAP. Differential pressure controller DN 15-50

STAP. Differential pressure controllers DN , ANSI fl anges

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE

STAG. Balancing valves Balancing valve with grooved ends DN

STAP. Differential pressure controller DN

Floor heating. Floor heating manifolds Distributors

STAD-C. Balancing valve ENGINEERING ADVANTAGE

STAD BALANCING VALVES

Harmony. Pressure Independent Balancing and Control Valve

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Pressure Reducing Valve DMV 755

Balancing Valves. Applications/ Features: Ordering Information: Accessories:

Pressure Independent Control Series

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Pressure Relief Valve DHV 718

AVP-F. p setting range (bar) Code No. 003H6200

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

HERZ-Motorised flow controler

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

Two-port valves, male threaded, PN25

Overview of types. Technical data. Safety notes

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Automatic balancing valves

Pressure independent control valve (PICV) FLOWMATIC

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Ballorex Dynamic Description. Versions. Benefits. Balancing

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

differential pressure regulating valve - threaded

STA-F Description. STA-F Prefab insulation Measuring nipples

3 & 4-Way Mixing & Diverting Valves

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

Differential Pressure Control Valve. Passim

Tank Blanketing Pressure Regulators RHPS Series

VBS-9263 Series. Application. Features. Applicable Literature

Pressure reduction controller (PN 16, 25, 40)

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

2-port seat valves PN25 with externally threaded connections

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Overview of types. Technical data

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

PVM 15-50, differential pressure valves

WaterSource Heat Pump Hose Kit Performance Specification-Summary

Pressure Independent Control Valve (PICV) Fig DN15-32

VB-7273 Series. Application. Features. Applicable Literature

HYDRAULIC CONTROL VALVES

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

PRESSURE INDEPENDENT CONTROL VALVE (PICV)

V311. Venta. Three-way Plug Valve, Flanged PN 16

Pressure independent balancing and control valve AB-QM DN

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

VB-7263 Series. Application. Features. Applicable Literature

Valve Proving System VDK 200 A S06*

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features:

TECHNICAL DATA. Q= Cv S

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Pressure Relief Valve DHV 718

Upgradable balancing valves USV

Butterfly Control Valve. DMK/6 Series

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure balanced valves (PN 25)

Products no longer available

Technical Data Sheet T 2025

Valve Proving System VDK 200 A S02

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Transcription:

TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads

IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the TBV-CM ensures accurate hydronic control and optimum throughput over a long lifetime. IMI Hydronic Engineering s dezincification resistant alloy, AMETAL, minimizes the risk of leakage. Key features > > Presetting tool For accurate and easy balancing. > > Shut-off function Ensures straightforward maintenance procedures. > > Self-sealing measuring points For quick and easy measurement. Technical description Application: Heating and cooling systems. Functions: Control Balancing Pre-setting Measuring Shut-off (for isolation during system maintenance) Dimensions: 1/ 1 Pressure class: PN 16 (30 psi) Temperature: Max. working temperature: 48 F Min. working temperature: -4 F Lift: 0.157 in Leakage rate: Tight sealing Material: Valve body: AMETAL Valve plug: PPS (polyphenylsulphide) Seat seal: EPDM/Stainless steel (1/ - 3/4 ). EPDM/AMETAL (1 ). Spindle seal: EPDM O-ring Valve insert: AMETAL, PPS (polyphenylsulphide) Return spring: Stainless steel Spindle: AMETAL AMETAL is the dezincification resistant alloy of IMI Hydronic Engineering. Marking: Body: TA, PN 16/150, DN, inch size and flow direction arrow. Identification ring on measuring point: White = Low flow (LF) Black = Normal flow (NF) Actuators: See separate information on EMO TM.

Valve characteristics TBV-CM LF, 1/, Cvs 0.46 TBV-CM NF, 1/, Cvs 1.16 Cv 0,5 Cv 1,5 0,4 0,3 0, 0,1 0 POS 8 1,00 0,75 0,50 0,5 0 POS 8 TBV-CM NF, 3/4, Cvs.33 Cv,5 0,0 POS 8 1,5 1,0 0,5 TBV-CM NF, 1, Cvs 4.65 Cv 5,0 4,0 3,0,0 1,0 0 POS 8 Standardised valve characteristic TBV-CM LF, 1/, Cvs 0.46 TBV-CM NF, 1/, Cvs 1.16 Cv/ [%] 0 50 POS 8 0 Cv/ [%] 0 50 POS 8 0 TBV-CM NF, 3/4, Cvs.33 Cv/ [%] 0 50 POS 8 0 TBV-CM NF, 1, Cvs 4.65 Cv/ [%] 0 50 POS 8 0 = gpm at a pressure drop of 1 psi at each pre-setting and fully open valve plug. Cvs = gpm at a pressure drop of 1 psi and fully open valve. h = lift 3

IMI TA / Control valves / TBV-CM Installation Application example STAD Installation of actuator Approx. 0.60 in of free space is required above the actuator. TBV-CM 1/ = 4.5 3/4 = 4.17 1 = 4.53 STAP ~ 0.6 Flow direction TBV-CM + EMO TM IP54 IP54 IP54 IP54 Sizing When Δp and the design flow are known, use the formula to calculate the Cv value. Cv 1.5 q in GPM, p in Ft Cv q in GPM, p in psi Setting TBV-CM is delivered with a red protective cap, Article No 5 143-0, which must be used when isolating the valve. TBV-CM is delivered with the pre-setting fully open. Pre-setting of a valve for a given value, e.g. corresponding to position 5, is done as follows: 1. Place the presetting tool, Article No 5 133-0, at the valve.. Turn the presetting tool so that position 5 is pointing at the index* of the valve body. 3. Remove the adjustment tool. The valve is now pre-set. *) There is a diagram for every valve size that shows the flow for different pressure drops and settings. 4

Noise In order to avoid noise in the installation the flows must be correctly balanced and the water de-aerated. Excessive differential pressures can cause noise in the installations, and in that case, differential pressure controllers should be used. The maximum recommended pressure drop in order to avoid noise is 4.35 psi. Measuring accuracy Maximum flow deviation at different settings TBV-CM LF ±% 0 18 16 14 1 8 6 4 1 3 4 5 6 7 8 9 *) TBV-CM NF ±% 0 18 16 14 1 8 6 4 1 3 4 5 6 7 8 9 *) *) Position Try to avoid mounting taps and pumps, immediately before the valve. D 5 D D D Closing force Necessary force (F) to close the valve versus the differential pressure (ΔpV). p [psi] 80 70 60 50 1 1/ - 3/4 40 30 0 0 15 0 5 30 F [lbf] 5

IMI TA / Control valves / TBV-CM Diagram TBV-CM LF, size 1/ p [PSI] Position Posi on 1 3 4 56789 7 5 3 1 0,7 0,5 0,3 0, 0,1 0,01 0,0 0,05 0,1 0, 0,3 0,5 0,7 1 Q [GPM] Position 1 3 4 5 6 7 8 9 0.06 0.19 0.4 0.7 0.9 0.34 0.36 0.38 0.41 0.46 = gpm at a pressure drop of 1 psi at each pre-setting and fully open valve plug. 6

Diagram TBV-CM NF, size 1/ p [PSI] Position Posi on 1 3 4 5 6 7 8 9 7 5 3 1,5 1 0,7 0,5 0,3 0, 0,1 0,07 0,1 0, 0,3 0,5 0,7 1 3 5 Q [GPM] Position 1 3 4 5 6 7 8 9 0.7 0.37 0.49 0.5 0.64 0.73 0.84 0.90 1.03 1.16 = gpm at a pressure drop of 1 psi at each pre-setting and fully open valve plug. 7

IMI TA / Control valves / TBV-CM Diagram TBV-CM NF, size 3/4 p [PSI] Position Posi on 1 3 4 5 6 7 8 9 7 5 3 1,5 1 0,7 0,5 0,3 0, 0,1 0,1 0, 0,3 0,5 0,7 1 3 5 7 Q [GPM] Position 1 3 4 5 6 7 8 9 0.44 0.55 0.73 0.87 1.08 1.8 1.39 1.74.0.3 = gpm at a pressure drop of 1 psi at each pre-setting and fully open valve plug. 8

Diagram TBV-CM NF, size 1 p [PSI] Position Posi on 1 3 4 5 6 7 8 9 7 5 3 1 0,7 0,5 0,3 0, 0,1 0, 0,3 0,5 0,7 1 1,5 3 5 7 15 Q [GPM] Position 1 3 4 5 6 7 8 9 0.93 1.8 1.6 1.97.44.90 3.5 3.71 4.9 4.64 = gpm at a pressure drop of 1 psi at each pre-setting and fully open valve plug. 9

IMI TA / Control valves / TBV-CM Articles L D Female thread Da H Size (DN) D Da* L [in] H [in] Cvs lb Article No ** North America Article No International TBV-CM LF, low flow 1/ 15 1/ NPT M30x1,5 5.04.8 0.46 1.08 5 143-715 5 143-515 TBV-CM NF, normal flow 1/ 15 1/ NPT M30x1,5 5.07.8 1.16 1.15 5 144-715 5 144-515 3/4 0 3/4 NPT M30x1,5 5.47.4.3 1.41 5 144-70 5 144-50 1 5 1 NPT M30x1,5 6.46.5 4.64.18 5 144-75 5 144-55 *) Connection to actuator. **) Distributed by Victaulic. Cvs = gpm at a pressure drop of 1 psi and fully open valve. = Flow direction TBV-CM Sets Kit package Valve TBV-CM and actuator EMO TM Boxed separately Kit No ** Size Description TBV-CM + EMO TM NC KIT 1/ 1/ TBV-CM LF (5 143-715) + EMO TM 4 V NC (1868-0.500) KIT09 1/ 1/ TBV-CM NF (5 144-715) + EMO TM 4 V NC (1868-0.500) KIT11 3/4 3/4 TBV-CM NF (5 144-70) + EMO TM 4 V NC (1868-0.500) KIT1 1 1 TBV-CM NF (5 144-75) + EMO TM 4 V NC (1868-0.500) **) Distributed by Victaulic.

Accessories Presetting tool For TBV-C, TBV-CM, TBV-CMP, KTCM 51 Article No 5 133-0 Ø0.866" Actuator EMO TM For more details of EMO TM, see separate catalogue leaflet. TBV-CM is developed to work together with the EMO TM actuator. Actuators of other brands require a working range of: X = 0.45-0.6 (closed - fully open) IMI Hydronic Engineering will not be held responsible for the control function if actuators other brand than IMI TA are used. 11

IMI TA / Control valves / TBV-CM The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. 5-5-8 US TBV-CM NPT threads v. 03.016