OPERATION OF SPILLWAY GATES HOW TO AVOID THE PROBLEMS AND PITFALLS. Peter Allen. DERM Qld

Similar documents
STRUCTURE S-65 PURPOSE SPILLWAY OPERATION

STRUCTURAL STABILITY ASSESSMENT

APPENDIX A STRUCTURE DESCRIPTIONS AND RATING CURVES

Attached as Exhibit B-2 is BC Hydro's presentation from the Stave Falls Spillway Gates Project Workshop held on January 18, 2010.

Emergency Action Plans for Dam Safety

STRUCTURE 65-B PURPOSE SPILLWAY OPERATION

22. Specialty Valves.

Plan B Dam Breach Assessment

Earthen Embankments. turning into larger, more costly repairs. The following. The State Dam Safety Program has inspection

Design of Spillway Upgrades

Every things under control High-Integrity Pressure Protection System (HIPPS)

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Float Valve Function and Design Considerations

USING A LABYRINTH WEIR TO INCREASE HYDRAULIC CAPACITY. Dustin Mortensen, P.E. 1 Jake Eckersley, P.E. 1

LESOTHO HIGHLANDS DEVELOPMENT AUTHORITY

COST EFFECTIVE STORAGE CAPACITY INCREASE FOR ALUMINA TAILINGS DISPOSAL AREA THROUGH SPILLWAY OPTIMISATION

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

CASE STUDY 1: GRANTHAM AND LOCKYER VALLEY FLOODS 2011

Innovative spillways. PK-weirs. Franska exempel 10/04/2018. Speaker : A. Chapuis,

Pressure Relief Valve Instruction Manual

DAM SAFETY GUIDELINES 2007

What I ve Learned About Dam Safety Good, Bad and Ugly

Using Reliability Centred Maintenance (RCM) to determine which automated monitoring systems to install to new and existing equipment

VIRGINIA SOIL AND WATER CONSERVATION BOARD GUIDANCE DOCUMENT ON DAM BREAK INUNDATION ZONE AND INCREMENTAL DAMAGE ANALYSIS AND MAPPING PROCEDURES

CLAIBORNE LOCK AND DAM PERTINENT DATA

SCOTTISH WATER. Waste Water Treatment Works. Typical WWTW Ellipse Equipment No: XXXX Ellipse Plant No: STW00XXXX

USER MANUAL. MACMAG magnetic separator MHK MHF

Cylinder Tilt Saddle Instruction Manual

Lecture 10 : Sewer Appurtenances

Transient Analyses In Relief Systems

Frequently Asked Questions Directive 056 Facilities Technical

Journal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

NORMAL OPERATING PROCEDURES Operating Parameter Information

COLD WATER STORAGE CONTROL AYLESBURY DELAYED ACTION FLOAT-ACTIVATED VALVES

COASTAL HAZARDS. What are Coastal Hazards?

CONTRACTOR SAFETY INDUCTION HANDBOOK

Greenup Lock Filling and Emptying System Study

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

VALVE CRITICALITY MODELING

IMPACT OF MAKING THE CREST OF WEIR MULTIFACETED ON DISCHARGE COEFFICIENT OF MORNING GLORY SPILLWAY

1 Exam Prep. Tabs and Highlights

OPERATION AND MAINTENANCE MANUAL

PRELIMINARY RISK ASSESSMENT RIDM PROJECT FOR A DAM WITH A VEGETATION- LINED SPILLWAY AND FERC PILOT

Lower Churchill Management Corporation. Nalcor Doc. No. MFA-PT-MD-0000-EN-PL

The Future of Hydraulic Control in Water-Systems

Unit 24: Applications of Pneumatics and Hydraulics

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

WATER LEVEL REGULATION

UNIT 15 WATER HAMMER AND SURGE TANKS

The safety of spillway gates

Modelling of Pressurised Pipes within InfoWorks ICM and CS

Introduction to Emergency Response & Contingency Planning

DIVING SERVICES UK COMMERCIAL & RESCUE DIVING CONTRACTORS

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

Introduction to Pumps

MEWP - Scissor Note: It is recommended that you read the Supporting Information page before you read this factsheet.

A study on the relation between safety analysis process and system engineering process of train control system

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Guidance Note. Hydropower Guidance Note: HGN 8 Fish Passage. When do you need to install a fish pass?

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

DESIGN OF BELL-MOUTH SPILLWAY AT BARVI DAM

NOVEMBER 2006 FLOOD DOWNSTREAM OF THE KATSE DAM STRUCTURE

Good things come in threes

TSS21 Sealed Thermostatic Steam Tracer Trap

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Experiment Instructions

OIL & GAS. MTS DP Committee. Workshop in Singapore Session 4 Day 2. Unwanted Thrust

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

The Best Use of Lockout/Tagout and Control Reliable Circuits

CARGO OPERATIONS (TANKER) MANUAL CH.05 BALLAST HANDLING. Rev. No: 2. Page: 1 of PURPOSE

APPENDIX C VEGETATED EMERGENCY SPILLWAY. VERSION 1.0 March 1, 2011

for the of and the EM55-1

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Engineering Safety into the Design

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Designing Labyrinth Spillways for Less than Ideal Conditions Real World Application of Laboratory Design Methods

Hydraulic Punch Drivers

Reliability Assessment of the Whistler Propane Vaporizers

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

Water Storage for Agriculture

O&M MANUAL HIGHLIGHTS

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Product Bulletin No.: D99-RRV2015-PIB-001

Active Hydrophore System AHS-01

DF1 and DF2 Diffusers

Installation and maintenance of twin 45kg LPG cylinder systems

T130/T131/T147. Economy Basket Stretcher with Lifting Kit

The Development of Multi-Rig Trawling Systems in the UK Past, Present and Future?

Report to COUNCIL for decision

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.

Reliability of Safety-Critical Systems Chapter 10. Common-Cause Failures - part 1

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

XXI Commonwealth Games. Gold Coast, Australia April Selection Policy and Standards December 2016

Transcription:

OPERATION OF SPILLWAY GATES HOW TO AVOID THE PROBLEMS AND PITFALLS Paper Presented by: Peter Allen Author: Peter Allen, Director Dam Safety DERM Qld 34th Annual Qld Water Industry Operations Workshop Indoor Sports Stadium, Caloundra 16 to 18 June, 2009 34 th Annual Qld Water Industry Operations Workshop Page No. 98

OPERATION OF SPILLWAY GATES HOW TO AVOID THE PROBLEMS AND PITFALLS Peter Allen, Director Dam Safety, DERM ABSTRACT The regulation of dam safety in Queensland is administered by the Dam Safety group of the Department of Environment and Resource Management. The department applies dam safety conditions to dams that would put lives at risk if they were to fail. Spillway gates allow the dam owner some flexibility in the operation of a dam both in terms of flood operations and for environmental releases. However, this flexibility comes at a cost. They require ongoing preparedness and trained personnel need to be on hand at all times. The paper details how spillway gates are normally operated; the systems and training necessary to operate spillway gates effectively; the regulatory arrangements that apply to referable dams in Queensland; some of the problems encountered and how to avoid these problems. KEY WORDS Referable dams, Spillway gates, Regulation of gated spillways, Incidents at gated dams 1.0 INTRODUCTION The responsibility for dam safety in Queensland rests solely with the dam owner. The chief executive of the Department of Environment and Resource Management (DERM) is responsible for administering the dam safety provisions in the Water Supply (Safety & Reliability) Act 2008. This is done by applying dam safety conditions which require the establishment of a dam safety management system for all referable dams. Referable dams are those dams that would put population at risk if they were to fail. If you are an operator of a referable dam in Queensland you should familiarise yourself with the conditions which apply to your dam. These conditions reference the Queensland Dam Safety Management Guidelines (NRM 2002) which giver further details. They are tailored for individual dams but tend to cover: Design and construction standards The maintenance and storage of dam documentation Reporting of incidents and failures The maintenance of dam data books, standing operating procedures and operation and maintenance manuals Periodic (annual) and comprehensive (5 yearly) inspections Periodic safety reviews The preparation and maintenance of Emergency Action Plans This paper will discuss the operation of gated spillways for large referable dams. These tend to be owned by water boards or government owned corporations but also include some local authorities. The operation of inflatable rubber bags that are seen on some Queensland weirs is not covered. 34 th Annual Qld Water Industry Operations Workshop Page No. 99

2.0 TYPES OF SPILLWAY GATES Spillway gates are designed to maximise the storage capacity of a dam while increasing the spillway capacity for a given headwater level. They can also be used for environmental releases which cannot be discharged from the outlet works. Gated spillways have been around for a long time and have been used at a number of Queensland dams. The examples include: Table 1: Examples of Gated Spillways Type of Gate Radial or tainter gates Vertical lift gates Sector or drum gates Tops gates Queensland Examples Somerset, Wivenhoe, North Pine, Leslie, Coolmunda, Ross River Beardmore, Leslie Harrison, Fitzroy Barrage Little Nerang Lenthalls Gates tend to be raised or lowered by winch systems or hydraulic rams but some have automatic systems based on balancing of water loads. There needs to be some redundancy in such systems to ensure they can operate on demand in stressful circumstances. The amount a gate is opened in response to floodwaters has to be determined in response to pre-determined operating rules. These operating rules must ensure the safety of the dam in the event of a maximum design flood. For major dams this is typically the probable maximum flood which is the theoretically greatest flood that could occur on the dam catchment. Operators need to: Be fully trained to operate their flood gates and to periodically exercise the gates Be onsite whenever gate operations are likely to be needed Be aware of the dam safety conditions and requirements that apply to their dam Know what gate operations are expected during a flood event including what to do in the event of a gate failing to operate Know how to maintain and do running repairs to gate opening systems Know when they are not operating as expected 3.0 TYPICAL GATE OPERATING RULES The most common operating rule is to set gate opening for a nominated headwater level. There is sometimes a minimum time between successive gate openings but, if the reservoir rise is too rapid and the gates fails to keep up, there is usually provision to progressively halve the gate movement intervals to allow the gate operations to keep pace with reservoir rises. The overriding rules are generally that the safety of the dam is paramount and that the rate of outflow does not exceed the rate of inflow during the rising stage of an incoming flood. In Queensland, the pinnacle of gate operations occurs at Wivenhoe and Somerset Dams in the Brisbane valley. They are operated as a tandem system to maximise the flood mitigation potential of the storages to protect the downstream areas of Brisbane, Ipswich 34 th Annual Qld Water Industry Operations Workshop Page No. 100

and a number of other communities. This degree of operation requires major investments in ALERT rainfall and river height sensors and real time modelling systems. In smaller floods decisions on gate openings are based on limiting the flows at Lowood and Moggill with the magnitude of the discharge being dependent on the reservoir level. The Wivenhoe Dam rules are illustrated in Table 1. Not all these criteria will be achievable at all times. To achieve them we may have to open and close gates during the initial stages of the flood event. e.g. If the flow in the Lockyer is increasing, we may need to close down the discharge from Wivenhoe to keep a bridge open but once the Lockyer flow inundates the bridge, the release from Wivenhoe can be increased to satisfy the next limit. Table 2: Flood operating rules for Wivenhoe Dam 4.0 GATE OPERATING INCIDENTS There have been several incidents at gated dams in Queensland. Fortunately none of these has led to a major failure although that is not a reason to relax. There was an incident at Leslie Dam near Warwick in the mid-late 1980s when, during a heavy mist, a water level sensor misread the reservoir level and the automatic gate operating system thought there was a flood in progress and it opened a gate prematurely. Fortunately, the reservoir level was below the gates and no water was lost but it caused a lot of rethinking on level sensors and the way the automatic operating system was employed. North Pine Dam just north of Brisbane had an incident in January 1982 when, it is understood, the flood engineer concluded that a flood event was over and shut down the flood control centre and went home (the flood engineer was the only person who could authorise gate movements). Soon after, there was another major burst of rainfall on an already saturated catchment. 34 th Annual Qld Water Industry Operations Workshop Page No. 101

Because none of the operators on site was authorised to open the gates, the water level rose rapidly to inundate the electrically powered gate lifting gear (which was housed under the bridge decking) and the gates were unable to be opened and the gates were overtopped. Figure 1: North Pine Dam Spillway Gates Figure 2: North Pine Dam Overtopping of gates during January 1982 I remember going out to the dam and seeing the Channel 7 helicopter hovering overhead and sure enough, it featured on the news that night with the story indicating what a good thing it was to see the dams overflowing. Those who knew anything about what was actually happening realised what a close run thing it was to dam failure and were horrified. There have been many changes to the North Pine operating rules and data gathering systems since that time. These developments, which have also been enshrined at other similar dams, include: improved real time rainfall and river height monitoring throughout the catchment 34 th Annual Qld Water Industry Operations Workshop Page No. 102

in combination with weather radar and improved forecasting and flood modelling; greater redundancy in gate opening systems; better trained operators who are empowered to operate gates in the event of loss of communications with flood controllers. There was an incident at Coolmunda Dam near Inglewood during a flood in 1978 when there was a blockage of a screen at the inflow into the automatic gate operating system which caused a gate to prematurely close. Fortunately the operators noticed something was going on and manually operated the gates until they eventually succeeded in removing the weeds blocking the inlet. Most recently there has been an incident at Lenthalls Dam just north of Maryborough in 2008. TOPS spillway gates were installed as part of a two metre raising of the full supply level (FSL) in 2007. Gates were designed to operate automatically in a progressive manner with water filling or draining from the buoyancy tank which formed the downstream skinplate of the gate. The operating system is illustrated in Figure 3. Figure 3: Lenthalls Dam opening sequence 34 th Annual Qld Water Industry Operations Workshop Page No. 103

Figure 4: Lenthalls Dam spillway Figure 5: Lenthalls Dam bottom gate seal During a flood event of Feb 2008, the gates failed to operate and the headwater rose to 1.27 metres above FSL without the gates opening as designed. Another lesser flood event occurred in July 2008 and one gate had to be manually operated. Figure 6: Lenthalls Dam during February 2008 flood Investigations eventually concluded that there was too much bottom seal friction to allow the gates to drop open when the buoyancy tank was filled. When you consider the deformation of the gates under load and the consequential additional compression on the seals with the addition of the overtopping water load, it also explains why the gates could be operated manually in test mode prior to the onset of the flood. The seals have since been modified to reduce this seal friction and there is every expectation that they will operate as designed during the next flood event. One outcome of this event was that people who lived upstream of the dam felt their safety was compromised by the failure of the gates to open and they increased their pressure for action by the dam owner to respond to both reduce the risk to them and to inform 34 th Annual Qld Water Industry Operations Workshop Page No. 104

downstream residents of the risks they were being exposed to. At the time of writing of this paper this is still to be resolved. 5.0 CONCLUSIONS Spillway gates are complex structures which need to be designed, operated and maintained by specialists who know what they are doing. Dam owners need to be aware of the responsibilities they incur when they own them. Operators need to be fully trained in their operation and to be eternally vigilant and aware of incoming events and of the consequences of failure. 6.0 REFERENCES NRM, Queensland Dam Safety Management Guidelines, 2002. These guidelines can be downloaded from: http://www.nrw.qld.gov.au/compliance/wic/referable_dams.html 34 th Annual Qld Water Industry Operations Workshop Page No. 105