GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Similar documents
Old documentation - Only for your information! Product is not available anymore!

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

Pressure regulator FRS

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

Pressure regulator FRS

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

Compact pressure switches for gas and air

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Ratio Regulator Zero Governor. FRG/6 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S06*

Tightness control TC. Product brochure GB 3 Edition AGA

Tightness controls TC 1 3 and TC 4

Solenoid valves VZWF, force pilot operated

GM Series Dual-Block Multi-Function Gas Control Valves

2/2-Way Solenoid Control Valve

Pressure regulators with solenoid valve VAD, VAG, VAV, VAH Flow rate regulator VRH Pressure regulators with double solenoid valve VCD, VCG, VCV, VCH

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Gas Pressure Switch for DMV safety shutoff valves

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Gas Pressure Switch for DMV safety shutoff valves

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

Safety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

4/2 way Pneumatic Solenoid Valve

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

GM-7000 Series CE Approved Gas Control Valve

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

Gas Pressure Regulator HON 300

Pressure Switch for gas and air GGAO-A4

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

VMR VMR-OTN VMR 6 bar

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Pressure Switch for gas and air

Pressure switch for gas and air

Fuel Filters DN15 DN25. elektrogas.com DE

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Double gas valves for biogases and recycling gases

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Gas Pressure Regulator HON 200

Датчики-реле давления GW A5 DUNGS

GAS PRESSURE CONTROL UNIT TYPE 132

Butterfly Control Valve. DMK/6 Series

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION DESCRIPTION INSTRUCTION SHEET

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK

VR46.5V(A)/VR86.5V(A) SERIES

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Regulator R 51

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

Safety Relief Valve HON 832

Transcription:

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-00-VEF 7.03 Max. operating pressure 30 mbar Compact design High flow values Low weight Low power consumption Modulating mode Adjustable outlet pressure up to 300 mbar Other available servo pressure regulator models: - zero pressure - constant pressure Printed in Germany Edition 07.08 Nr. 3 59 Mountable accessories - Pressure switch - VPS Ratio V = / p L = 0.: 3: Zero point correction possible Internal pulse line Technical Description The DUNGS multiple actuator MBC VEF offers filter, valves and servo pressure regulator in one compact unit: - Dirt trap: microfilter - solenoid valves up to 30 mbar as per DIN EN class A group - Servo pressure regulator as per DIN EN 88 class A group ; EN 07- - Fine setting of gas and air pressure ratio - Flange connections with pipe threads as per ISO 7/ or NPT - Easy to install - Low weight As this system has a modular design, we can offer individual solutions with valve inspection system, pressure switches mini/ maxi and pressure limiters. High flow values at low pressure difference. Application The servo pressure regulator permits optimum mixture formation in forced air burners and premix burners; this applies to modulating and multi-stage variable operating modes. Suitable for gases of gas families,, 3 and other neutral gaseous media. Approvals EU type test approval as per EU Gas Appliance Directive: MBC...VEF CE-0085 BM 035 EU type test approval as per EU Pressure Equipment Directive: MBC...VEF CE003 Approvals in other important gas-consuming countries. 8

Functional Description Gas flow. If the V and V valves are closed, chamber a is under inlet pressure.. The min. pressure switch (option) is connected to chamber a via a borehole. If the inlet pressure exceeds the reference value set in the pressure switch, the switch switches through to the automatic burner control. 3. The V and V valves open after they are enabled by the automatic burner control. Gas flow through the chambers a and b is enabled. Functional description of the valveregulator combination Valves V and V can be controlled electrically and independent of each other. Each valve pretensions its own pressure spring when the plunger opens. If both valves are open, a pressure pulse is sent under the working diaphragm M. The intensity of this pressure pulse changes depending on the adjustable restrictor point D. The comparison diaphragms S for burner pressure and S for blower pressure p L are connected with each other via a rod. The ratio V can be set by shifting the bearing point. Zero point correction N acts on this rod mechanism via the air diaphragm S. Ambient pressure p amb or firing chamber pressure p F must be applied to the area between the comparison diaphragms. The firing chamber pressure reduces the burner pressure at a ratio of V >. Changes in the equilibrium of forces result in a change in the flow crosssection. The pressure under the working diaphragm is re-adjusted. The regulator unit adapts the free valve cross-section depending on the new flow requirement. Closing function If the supply voltage of the solenoid coils of V and V valves is interrupted, the pressure springs close the valves in <s. Block diagram MBC...VEF M D S S R Working diaphragm Restrictor Servo diaphragm for burner pressure p BR Servo diaphragm for blower pressure p L Regulator disc 0 Pressure regulator unit Regulator spring 3 Connecting flange Coarse filter and microfilters 5 Valve V Closing spring V 7 Housing 9 8 7 5 3 Pressure taps, gas train diagram MBC...VEF p a p R M V S V S b a, b Pressure chambers in flow direction p Inlet pressure Burner pressure, outlet pressure: P amb Ambient pressure Blower pressure p L V 8 Plunger V 9 Solenoid V 0 Printed circuit board Electrical connection Valve V 3 Closing spring V Plunger V N D internal standard p F p amb p L p F 5 3 8 7 p L external option 5 Solenoid V Solenoid housing Setting: 7 Gas-air ratio 8 Zero point correction 3 5 7,, 3,, 5 Screw plug G /8, 7 Seal plug G /8 3 8

Technical Data Nominal widths Flanges with pipe threads according to ISO 7/ (DIN 999) Max. operating pressure Inlet pressure range Guiding range Burner pressure range Media Ambient temperature Dirt trap device Pressure switch Servo pressure regulator Ratio setting range V Zero point correction N Solenoid valve V, V Measuring gas connection Burner pressure monitor Pulse and connection lines Voltage/frequency Electrical connection Rating / power consumption Switch-on duration Switching cycles Degree of protection Radio interference suppression MBC-00-VEF Rp /, 3/,, / Rp, /, /, Rp, /, /, and their combinations and their combinations and their combinations 30 mbar p e : 5 mbar to 30 mbar p L : 0, mbar to 00 mbar : 0,5 mbar to 00 mbar Gases of gas families,, 3 and other neutral gaseous media. -5 C to +70 C (do not operate MBC VEF below 0 C in liquefied gas systems. Only suitable for gaseous LPG; liquid hydrocarbons destroy the seal materials) Micro-filter made of chopped-strand nonwoven fabric. Filter replaceable without removing fitting The system can be equipped with pressure switch types GW A5, NB A, ÜB A as per DIN EN 85. For further information, refer to data sheets Pressure switch for DUNGS multiple actuators 5.0 Servo pressure regulator with adjustable burner pressure, as per DIN EN 88 class A, group ; EN 07- Gas-air ratio control with adjustable ratio V as well as correction of zero point N and firing chamber pressure connection Ratio V = / p L = 0.: 3:, other ratios on request possible Valves as per DIN EN class A group ; fast closing, fast opening G /8 DIN ISO 8, at inlet and outlet flanges, on both sides downstream of filter, between V and V, downstream of V (fitting the pressure switch may partially exclude measuring gas connection) Downstream of valve V, pressure switch can be mounted on the side of the adapter G /8 connection as per DIN ISO 8 for burner pressure (pbr; GAS), blower pressure (pl; AIR), firing chamber pressure (pf; combustion, atmosphere) Pulse and connection lines must be made of steel and conform to PN, DN. Condensate of pulse and connection lines may not enter the fitting. Strictly follow the operating and mounting instructions. ~(AC) 50-0 Hz 30 V -5 % +0 %, other voltages on request. Other preferred voltages: ~(AC) 00 V - 0 V, =(DC) V - 8 V Plug-in connection as per DIN EN 7530-803 for valves at ~ (AC) 30 V; +0 C: see type overview 00 % duty 0 per hour (30 s on/off) IP 5 as per IEC 59 (EN 059) Interference level N Materials of gas-conveying parts Housing Diaphragms Solenoid drive die-cast aluminium NBR basis steel, aluminium Installation position Vertical with upright solenoid or horizontal with horizontal solenoid, as well as their spacers 3 8

Dimensions [mm] MBC-300/700...VEF MBC-00...VEF e = space required for replacing the solenoid Mounting the pulse lines MBC...VEF p e : gas inlet pressure 5-30 mbar : burner pressure, gas 0.5-00 mbar optional: external pulse standard: internal pulse p F : firing chamber pressure -0 mbar +50 mbar or atmosphere 7 p L max. = p L - p F = 00 mbar max. = - p F = 00 mbar 7 p L : blower pressure, air 0. -00 mbar 8

Pulse lines Pulse lines,, 7 must be made of steel and correspond to DN (diameter mm), PN. Other pulse lines materials are permissible as per type test together with the burner. Route pulse lines in such a way that no condensate can flow into the MBC...VEF. Route pulse lines in such a way that they are protected against cracks and deformation. Keep pulse lines short. Type Version Order no. 30 VAC DN Rp Opening time a Dimensions [mm] b c d e f g Solenoid no. Switching ops/h Weight [kg] 030 / - / < s 95 3 73 3 87 3 03/P 0 3,8 3 07 - < s 7 80 8 7 5 0/P 0,5 MBC-00-VEF 3 3 - < s 0 9 38 530 05/P 0,8 MBC-00-VEF P max. [VA] for t = 3 s 0 0 00 P max. [VA] operation 0 0 30 Flange for Rp/NPT Order no. Order no. Rp / Rp 3/ Rp Rp / 3 3 00 0 50 Line socket 3 pole + PE 0 39 Rp Rp / Rp / Rp 33 3 88 9 Adapter, pressure gauge flange set G/ Adapter GW A with G/ Adapter Adapter GW A on flange 75 98 975 30 NPT / NPT 3/ NPT NPT / 37 38 999 3 78 Flanges, plug-in connection and system accessories must be ordered separately. NPT NPT / NPT / NPT 39 370 003 997 5 8

MBC...VEF key data Application Application Gas Type of gas / specific density [kg/m 3 ] Volumetric flow V [m 3 /h] V min. V max. Inlet pressure p e [mbar] p e,min. p e,max. Burner pressure [mbar] at V min. at V max. Blower pressure p L [mbar] at V min. at V max. Firing chamber pressure p F [mbar] at V min. at V max. Control range, output range Time taken to re-adjust air volume restrictors from small load to large load [s] Starting load [m 3 /h] Company / address Name / contact person Telephone f = V used Gas = Air density Density of gas used V Air x f Gas type Natural gas City gas Liquefied gas Air Density [kg/m 3 ] 0,8 0,58,08, dv 0,5 0,7,7,00 f,, 0,77,00 8

Volume flow pressure difference characteristics in steady state with microfilter. 30 300 00 50 00 80 0 50 0 30 Recommended operating range MBC-300-... (Rp 3/) MBC-300-... (Rp /) MBC-300-... (Rp & /) 0 0 8 5 3 Basis + 5 C, 03 mbar, trocken Based on + 5 C, 03 mbar, dry Base + 5 C, 03 mbar, sec Base + 5 C, 03 mbar, secco 3 5 7 8 90 0 30 0 0 80 00 00 Vn [m 3/h] Luft / Air / Aria dv =,00 3 5 7 8 90 0 30 0 0 80 00 00 Vn [m 3/h] Erdgas/Natural gas/gaz Naturel/Gas metano dv = 0,5 Volume flow pressure difference characteristics in steady state with microfilter. 30 300 00 50 Recommended operating range MBC-700-... (Rp /) MBC-700-... (Rp ) 00 80 0 50 0 30 MBC-700-... (Rp / & ) 0 0 8 5 3 Basis + 5 C, 03 mbar, trocken Based on + 5 C, 03 mbar, dry Base + 5 C, 03 mbar, sec Base + 5 C, 03 mbar, secco 3 5 7 8 90 0 30 0 0 80 00 00 Vn [m 3/h] Luft / Air / Aria dv =,00 300 350 3 5 7 8 90 0 30 0 0 80 00 00 Vn [m 3/h] Erdgas/Natural gas/gaz Naturel/Gas metano dv = 0,5 7 8

GasMultiBloc Combined regulator and safety valve Infinitely variable air/gas ratio control mode MBC-00-VEF Volume flow pressure difference characteristics in steady state with microfilter. MBC-00-VEF Recommended operating range Basis + 5 C, 03 mbar, trocken Based on + 5 C, 03 mbar, dry Base + 5 C, 03 mbar, sec Base + 5 C, 03 mbar, secco We reserve the right to make changes in the interest of technical progress. Head Offices & Factory Karl Dungs GmbH & Co. KG Siemensstraße -0 D-730 Urbach, Germany Telefon +9 (0)78-80-0 Telefax +9 (0)78-80- Postal address Karl Dungs GmbH & Co. KG Postfach 9 D-730 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com 8 8