INFLATION & INTEGRITY TEST SYSTEM

Similar documents
FlexAct BT (Bag Tester) Validation November, 2015

628 Differential Pressure Decay Leak Tester

Assembly and Installation Procedures

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Glove Management. PDA Ireland Chapter Dublin 04 th Oct Dr. Aidan Harrington DPS Group

Succeeding with Production Air Leak Testing Methods. Paul Chamberlain President, CEO

Finding Leak Testing Success Through Calibration and Validation. Paul Chamberlain President, CEO

Chamber Test Testing Theory

SterileBarrierPackaging: CommonCausesofFailures. PackagingSectionLeader NelsonLaboratories

Providing the Benefits of Seitz Filter Media in the Most Versatile Capsule Format Available

Chapter 6 Leak detection

SÜDMO ASEPTIC PROCESS VALVE SECURE FOOD & BEVERAGE ASEPTIC PROCESS VALVE SECURE

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

BERMAD Fire Protection Hydraulic Control Valves

Data Sheet... RUDOLPH, inc. HANS RUDOLPH,

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Vehicle- or rack-mounted liquefied gas meters, pump supplied

STANDARDS FOR COMPRESSED GAS TESTING

Instruction Manual Dräger MSI P7 and MSI P7 plus

BIOCLOSURE SYSTEM ASSEMBLIES

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Technical Information Conducal CLY421

Int r oduct ion t o Int egr it y Tes t ing Theor y

Quality filter cartridges and customized housings.

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Perform Pressure & Leak Test, Tubing & Piping. Module 12306

OPERATING INSTRUCTIONS

Sterile Sampling Bottle Assembly

Vehicle-mounted meters, pump supplied

SHELL FLAGS INSPECTION CASE STUDY

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

The latest automotive systems require innovative leak test methods and fixturing.

Installation Instructions

DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

ECOBULK FOODCERT + ASEPTIC The highest packaging safety for your food products

Do Not Print This Page.

The New PHD 4 Portable Helium Detector

STANDARD OPERATING PROCEDURES

EKC International FZE. Safety Instructions For Handling & Inspection Manual For Refillable Seamless Steel Gas Cylinders

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

SINGLE VALVE WITH LOW-FLOW BYPASS

Qi Litre Ultrasonic Cleaner

KJ1000 Operating Instructions & Parts Manual NSN

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

REQUIREMENTS FOR PACKAGING. Wim Renders

Sterile Sampling Bottle Assembly

Four common PRESSURE CALIBRATION PAIN POINTS

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Trifecta High-Pressure Systems

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

SEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems

Model 601CV. Mass Flow Controller. Product Features:

Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar

Vacuum Insulated vertical cryogenic CO 2 & N 2 O Tanks

EMT EnvironmentalMonitoringTECHNOLOGIES

BIO GAS STORAGE TANKS. for each Plant Design. Long service life. Maintenance free set-up. Permanently gas-tight. Quickly installed

OPERATION MANUAL PNEUMATIC VALVES

Development of a High Pressure, Oil Free, Rolling Piston Compressor

SRL SEries. Oil Free Scroll Air Compressors hp kw

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

"INOGATE Technical Secretariat & Integrated Programme in support of the Baku Initiative and the Eastern Partnership energy objectives" Project

SKYBOX USER GUIDE EMERGENCY ULTRAFILTRATION PACKAGE. The trusted choice for rapid response potable water solu4ons SKYBOX

MyControl Bathing System Signature Series

Copyright, 2005 GPM Hydraulic Consulting, Inc.

A Perspective on Filter Cartridge Issues

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Pegasus SV4 Virus Removal Filter Cartridges and Kleenpak Nova Filter Capsules with Pegasus SV4 Virus Removal Filter Membrane

Rate of Flow Valve Series 120

APPS-160 Gen 2 User Manual

Float Operated Level Controllers

Tank Blanketing. Application Jordan Valve Product Offering Competition

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

COOPER POWER SERIES. EL Bay-O-Net Current-Limiting Fuse Installation Instructions. Fusing Equipment MN132023EN

OEM Manual. MODEL ½ Digit DRUM SCALE

Table of Contents - ALpHA Filters

Instruction Manual for Configura Cushionair Portable Pump

Inert Air (N2) Systems Manual

Instructions For Use USD3156. Kleenpak Capsule with Pegasus Protect Prefiltration Membrane

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

Filter Integrity Testers for the Pharmaceutical Industry

TECHNICAL INFORMATION

PANACEA P200 STAINLESS STEEL USER MANUAL

R2S Standard Sampling Assembly OPERATION PROCEDURE

OPERATION MANUAL. Hand Held Leak Tester Model # ZUTR-10002

Flow rates to 200 l/min

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

EuroBioConcept s.a.s Hospital Pharmacy Isolator Systems

Transcription:

INFLATION & INTEGRITY TEST SYSTEM

The Power of Knowledge As the value of processes increase with each step downstream, the value of sterility and leak detection become even more critical. insite provides the confidence of a final integrity test prior to use; at the point-of-use. The insite Inflation and Integrity Test System provides an added level of confidence at the point-of-use by testing bags for damage that could occur from the box to the tank. More specifically, insite detects gross or fine leaks that can occur between the end-user s warehouse to the clean room floor from improper handling and loading procedures.

Quality Assurance The advantages of the insite System extend the level of Quality Assurance that ASI employs to the end user. Although ASI maintains stringent standards for all of its products such as raw material inspections, in-process pressure decay testing, sealing validations, packaging and shipping procedures and more, there is potential for damage after the product leaves ASI s facility; specifically during bag handling and placement. insite offers a level of confidence to bio-pharmaceutical manufacturers at the critical stage of fluid filling, ensuring that their product will enter an integral bag. insite 3

Pressure Decay Testing Pressure decay refers to the change of pressure (P) inside a pressurized containment during a leak test. The test is an inflation test in which a bag is pressurized to a preset level. After the bag system has stabilized, the decay in pressure over time is evaluated to determine if a leak is present. ASI chose the pressure decay method of testing due to its sensitive results and practicality at the point-of-use. In comparison to alternative methods of leak detection, pressure decay yields quantitative information and measurable data points that can be recorded and upon which decisions can be made. The sensitivity of pressure decay testing is dependent upon three factors: the size of the bag, the change in temperature and the amount of time allotted for the test. Any variances in these conditions can affect test results making it important to have a consistent environment and setup for each test. There are four distinct phases to the pressure decay testing process; each step is unique to pressure decay and ultimately makes the placement and filling cycle easier for the operator and gentler to the bag. 1. Inflation cycle 3. Settle Time Inflation is the period of time in which the bag system The settle phase is the time allowed for the volume of is being pressurized to a predetermined test pressure the bag system to change and stabilize due to stresses through an onboard blower. The air is forced through a introduced by pressurization. The adiabatic temperature 0.2 micron (μm), sterilizing grade filter. also stabilizes during the settle phase. 2. Charge Time 4. Test Time During the charge time phase, the bag system The test time is the period during which the decay stretches allowing any creases that may be present of pressure is measured and recorded. This decay in to unfold. If necessary, the blower will add air to pressure will distinguish between a flawed and maintain the initial predetermined test pressure. non-flawed bag system. 4 www.asisus.com

insite Specifications OVERALL SIZE: 32 W x 30 D x 58 H WEIGHT: Approximately 340 Lbs. Standard MODEL NUMBERS: IN1003 (Battery Powered- US) IN1005 (AC Powered US) IN1004 (Battery Powered Europe) IN1006 (AC Powered Europe) Air Outlet Touchscreen Monitor Pressure Input Wire Pressure Monitor Bar Code Scanner Onboard Label Printer (Prints Test Results) Clean Room Grade Casters insite 5

More than Just a Test In addition to the long-term value that the Integrity Testing functions provide, insite has a host of additional features that ease the operator s tasks and manage the overall quality of the bag all the way up to the liquid filling cycle. Inflation CYCLE - The inflation cycle assists the operator in the loading of bags with minimal intervention and reduces the risk of flaws from handling. Gross Leak Detection - This detection test quickly finds small leaks (between 250 μm 1000 μm) and confirms connection and setup of the bag system. Fine Leak Detection - A unique validated detection test for each tank and bag assembly. It is dependent on time allotment and environment. Very fine leak detection is possible. LIQUID FILLING CYCLE- This cycle moderates the internal pressure within the bag while fluid is being introduced. The cycle is configured to regulate the pump or valve and will terminate the filling process if the bag system becomes over-pressurized. 6 www.asisus.com

Validation Setup and Testing Results Due to the sensitivity of the insite system, the testing results can vary from any changes in external pressure, tank size or room temperature so it is a vital rule of thumb to have a consistent environment for each setup and test. During the setup procedure, the programs walk the user through a Validation Setup. The Validation is unique to each bag and tank combination and is stored for quick access for future tests. During this phase, users are instructed to run a minimum of three or a maximum of ten successful bag tests and three to ten (intentionally) flawed tests. Pressure Pressure Non-Flawed Bag Non-Flawed Bag Flawed Bag Inflation Charge Settle Test Inflation Charge Settle Test Time Figure 1: The four phases of the testing cycle of a non-flawed Bag. Time Figure 2: A comparison of a flawed bag and a non-flawed bag. NF-1 (ΔP NF-2 (ΔP NF-3 (ΔP Pressure F-1 (ΔP1 F-2 (ΔP2 F-3 (ΔP3 Pressure Buffer Zone Non-Flawed Bag Flawed Bag Non-Flawed Bag Flawed Bag Test Cycle Test Cycle T1 T2 T3 Time Figure 3: A comparison of the three successful bag tests and the three intentionally flawed bags. The measurements between the Delta P s for each will determine the allowable variance. Time Figure 4: The variance between the highest Delta-P of a non-flawed bag and the lowest Delta-P of a flawed bag determines the buffer zone. The buffer zone is the established point of time for the fine leak flag. This also establishes the validated pass / fail point criteria. insite 7

ASILife Sciences ASI 163 Research Lane, Millersburg, PA (717) 692-2104 (800) 724-4158 www.asisus.com ASI is an FDA Registered, ISO 13485:2003 Certified Manufacturer Rev: 04-03-13 MK-00213