Compresso Connect F INSTALL

Similar documents
Compresso Connect C10.1 / C15.1 / C10.2 / C15.2 INSTALL

Vento VI Connect VI 19/25 INSTALL

Compresso Connect. Pressure maintenance systems with compressors For heating systems up to 12 MW and cooling systems up to 18 MW

Pressure maintenance system with pumps and integrated vacuum degassing

Compresso Connect F. Pressure maintenance systems with compressors For heating systems up to 4 MW and cooling systems up to 6 MW

Pressure maintenance systems with compressors

Transfero TI. Pressure maintenence systems with pumps Pressure maintenance systems up to 40 MW with pumps

Transfero TVI Connect

Pressure maintenance systems with compressors

Transfero T_. Pressure maintenance system with pumps For systems up to 10 MW

Pressure maintenance systems up to 10 MW with pumps

Aquapresso. Pressure stabilisation for potable water Pressure stabilisation for potable water

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

LIKE ME. Expert, highly efficient and customer-orientated

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

1 Notes on the operating manual Liability and guarantee Safety Description of the device... 9

Vacuum spray degassing

Transmitter CS 21 Operation Manual

STAP. Differential pressure controllers DN , ANSI flanges

Transmitter CS 21 Operation Manual

1 Notes on the operating manual Liability and guarantee Safety Description of the device... 9

STAP. Differential pressure controllers DN , ANSI fl anges

Mass Flow Controller (MFC) for Gases

Flamco Flamco-Fill STA Flamco-Fill STM

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Panther 5 Acute Care Ventilator

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Manual Power relay SR853

DK48 - DK800. Quick Start. Variable area flowmeter

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

STAG. Balancing valves Balancing valve with grooved ends DN

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Accessories. Accessories for pressure maintenance

TA-FUSION-P. NPT threads / ANSI flanges

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Tightness controls TC 1 3 and TC 4

Oxymax COS61/COS61D. Technical Information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Airox Supportair Ventilator

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Pressurisation Systems. Variomat. Pump Controlled Pressurisation Systems. Pressure maintenance Deaeration Water make-up. For Control Touch:

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

STA. Double regulating valves DN 15-50

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

System Pressure Manager Standard & System Pressure Manager Plus

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

reflex gigamat Pressure-maintaining station Assembly, operating and maintenance instructions Status 03/07

Mass Flow Meter (MFM) for Gases

STA. Double regulating valves DN 15-50

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

2-Port Seat Valves with Flange, PN 16

Pressure Measurement Single-range transmitters for general applications

Technical Data. General specifications. Rated operating distance s n 5 mm

Installation and Operation Manual

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Oxygen Meter User Manual

STAD-C. Balancing valves DN 15-50

Installation, use and maintenance instructions. Gas burner (5)

2-Port Seat Valves with Flange, PN 16

MANUAL GAS MANIFOLDS

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

BUBBLER CONTROL SYSTEM

Technical Data. Dimensions

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Electronic gas volume corrector model DGVC-04

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

AUTOMATIC GAS MANIFOLDS

Mass Flow Controller (MFC) for Gases

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

Magnetic level switch type MR783 Instruction Manual

Floor heating. Floor heating manifolds Distributors

Expert Hydrostatic Level Transmitters

Tightness control TC. Product brochure GB 3 Edition AGA

Flamco

OPERATORS MANUAL AHCON PCI 1000

I003 Lock Out - Tag Out - Try Out. Document information

Oxygen Dialflow Meter. Instructions for Use

reflex variomat Pressure-maintaining station Assembly, operating and maintenance instructions Status 03/07

DGBOX rev Inverter electronic control panels for single pumps or pumping units OPERATOR S AND MAINTENANCE MANUAL

SonoMeter 30 Energy Meters

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

OC508 Programmable mv Calibrator

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Budget Range Operators Handbook

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

High-performance submersible pressure transmitter For level measurement Model LH-20

Operating Instructions in accordance with the Machines Directive 2006/42/EC

Speed Controller ADR 40 Condensing pressure controller SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP

KTM 50 (DN ) Installation, maintenance and operating instructions

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

Transcription:

en de fr nl SAFETY INSPECTION DISASSEMBLING prescriptions SAFETY INSPECTION Personnel Installing and operating personnel must possess the appropriate knowledge and training. Follow the instructions Installation, operation, maintenance and disassembly must be carried out as stated and showed in the different instruction manuals making integral part of the delivery and in accordance with best practice. If anything is unclear, please contact IMI Hydronic Engineering customer service. Tests for commissioning and periodic inspections Test required for commissioning and periodic inspections must be performed according to the regulations in the country where the device is installed and operated. There are no unified international regulations for the acceptance test prior to commissioning and periodic inspections. It is usually the vessels that determine how the installation is classified. These are CE type-tested in accordance with guideline PED/DEP/97/3/EC for pressurised equipments. For periodic inspections, openings are provided for flange-type or endoscope inspections. In Switzerland, Compresso does not require autorisation from the SVTI if the installation is protected in such a way that psch is not exceeded. Vessels with psv x V up to 3000 bar*litres do not require inspection by the SVTI. Following combinations with TecBox are recommended: Primary vessel () TecBox safety valve (SV) C 10 C15 1000 litres 3 bar on request 800 litres 3.75 bar on request 700 litres 4. bar on request 600 litres 5 bar on request 500 litres 6 bar 6 bar 300 litres 10 bar For Transfero as many extension vessels as required can be connected to the primary vessel. The CE-approved bar safety valve protects the vessels from inadmissible pressures. In Switzerland, SVTI inspection is not required for these types of vessels. Place of installation The access to the place of installation must be restricted to trained and specialised personnel. The floor statics must be able to support the maximum operating and installation conditions. Connections for electricity, communication, main water and waste water must correspond to the requirements of the device. The room must be thouroughly ventilated. Water quality IMI Hydronic Engineering devices are designed to maintain pressure, to degass or to make-up and/or treat water in closed heating, solar and cooling systems with water that contains no aggressive or toxic agents.the entire system must be dimensioned and operated in such a way as to minimise the amount of oxygen admitted through the make-up water or through permeable components. Water treatment systems are to be dimensioned, installed and operated according to the current state of the art. Electrical connection The electrical and the communication wiring and connections should be carried out by a qualified electrician, in accordance with current local regulations. The devices and the potential free outputs must be disconnected from the electrical supply before working on electrical components. Protection on the supply to be done by the contractor: Compresso C10.1; C15; CX: 10 A Compresso C10.; C15.: 16 A Transfero range 4;6;8;10 = 1 x 30 V: 16 A Transfero TPV...P = 3 x 400 V: 10 A Vento range,3,4,6,8,10 = 1 x 30V: 16 A Vento range 13,19 = 3 x 400 V: 10 A Pleno PI9.1; PI6.1: 10 A PI6.: 16 A Residual current device (RCD) following local regulation. If installed in residential building we recommend a commercially available line filter to the junction box. WCMOIN0004 05.016 Compresso Connect F INSTALL Compresso Transfero Vento PlenoI www.imi-hydronic.com

The texts, graphics and diagrams in this document may be subject to alteration without prior notice or reason being given. www.imi-hydronic.com TecBox Compresso CU Compresso CG x3 x5 AVV DLV CDVV CDVV LT LT

DLV 600 mm 0% OK 0% Hygro 80% 100% +5 C - +40 C 0% - 80% 1x30V Cl : < 60 mg/m²/4h 150 mm 3

Compresso CU Compresso CG 3 ACV 4 ACV 3 CDVV CDVV 1 1 4

DNe SVS DNe DNe DNe IMI Hydronic Engineering DNe 30 m DNe 0 5 3 EN 188 Q kw 1000 1700 3000 SWKI 93-1 * Q kw 300 600 900 ts max 50 C Q kw 1600 700 5000 *) CH 5

TecBox SA1 SVV SF1 V1 PT 1 x3 CLICK! 6

3 x5 4 7

x CU / CG CUE / CGE 8

30V/50/60 Hz 10A / 3 x 1,0 mm #1-5 1 L 1! PE N 3 4 L PE N 5 6 BrainCube Connect! www.imi-hydronic.com 9

30V/50/60 Hz Sicherung/ fusible/ fuse 10 A / 50V / 5x0 F00 Klemmen Ausführung C.1 Version des bornes C.1 Terminal execution C.1 30 V 50/60 Hz LINE P/C1 V1 V3 V4 WM V P/C OD1OD OD3 OD4 L N PE L N PE L N PE L N PE 13 14 13 14 13 14 Achtung: Fremdspannung BN BU GNYE BN BU GNYE BN BU GNYE BN BU GNYE Attention: tension externe Attention: external voltage G erätestecker Fiche Main plug 16 A M 1 ~ C NO C NO C NO *A *A max. A Leitungsabsicherung bauseits Protection de la ligne max. A par l `installateur max. A line protection by c ontractor Netzversorgung P1 V1 Alimentation K ompressor Ü berströmv entil electrique Compresseur Network supply C ompressor V anne de 30V/50/60 Hz decharge 10A / 3 x 1,0 mm² Spill valve WM Nachspeisev entil V anne d`appoint d`eau Water make up valve Meldungen Gebäudeleittechnik Programmierbar, Zuordnung nach Menü Parameter Report de messagevers la GTC, affection siuvant menu-parametres B uilding control reports, allocation acc. to menu-parameter 4V Klemmen Ausführung C.1/C. Version des bornes C.1/C. Terminal execution C.1/C. SELV IA5 IA4 IA3 IA IA1 ID4 ID3 ID ID1 OA OA1 IDA IDA1 GND IN + GND IN + GND IN GND IN SHIELD WH PE BN GN BN 1 1 OUT + PE OUT + 1 1 p P P S ensor Gefässinhalt LT C apteur de n iveau LT Level sensor LT S ensor Anlagendruck PT C apteur de pression PT Pressure s ensor PT TAZ+ PAZ- Grenzwertschalter C ontacteur de seuil Limit switch Jumper (RS485) off = Offen / stationne / open on = Gesteckt / branche / connect ID6 ID5 IDA3 RS 485 IN OUT A B S A B S SHIELD SHIELD GND IN GND IN GND IN + LAN / Ethernet A B S A B S RS458 USB 10

11

We reserve the right to introduce technical alterations without previous notice. www.imi-hydronic.com