STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Similar documents
Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

Hydrofluoric Acid SOP

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

Working Safely with Hydrofluoric Acid

TEMPLE UNIVERSITY A Commonwealth University Environmental Health & Radiation Safety (EHRS)

CCM Approval: IACUC Approval:

Biosafety Level 2 (BSL2) Laboratory Safety Inspection Checklist

Fire Escape Hood OPERATION AND INSTRUCTIONS

Laboratory Safety Inspection Checklist

Standard Operating Procedures (v9 5/1/17)

STANDARD OPERATING PROCEDURE (SOP): URETHANE

Standard Operating Procedure (SOP)

Standard Operating Procedure

HVAC Considerations for Gaseous Decontamination of Laboratory Spaces using Hydrogen Peroxide Vapor

Standard Operating Procedure for Solvent use in EMAL

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

VCH Ebola Virus Disease Health Care Worker PPE Checklist/Sign In-Out Sheet

Transfer Procedures. By the end of this chapter, you will be able to: The Transfer Process. Chapter 12

NUS Safety & Health Guidelines Procedure No: OSHE/SOP/GL/08

Hydrofluoric Acid. Syracuse University Laboratory Standard Operating Procedure. I. Purpose: Physical and Chemical Properties: Potential Hazards:

Laboratory Safety Training. Environmental Health and Safety

Date Effective: Date Reviewed: Nebraska Biocontainment Unit. Doffing Biological Protective Suit and PAPR

Cryogenic Materials Operating Procedure and Safety Requirements

Yeo Soh Bee A/Prof Dan Yock Young 28/03/2016 Prepared by Approved By Issue Date

Print PERSONAL PROTECTIVE EQUIPMENT

1. Substance Information

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

Work Method Statement. Prepared for: The Bolton NHS Foundation Trust Prepared by: Mark Fentiman Date:

Instructions in the Use of Radiation Protection. Equipment and Radiation Measuring Instruments by. Disaster Response Personnel in a Nuclear Emergency

Shukla Medical. TITLE: Manual Surgical Orthopedic Instruments Recommendations for Care, Cleaning, Maintenance and Sterilization

Laboratory Self Inspection Checklist LAB01

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

Chemical Spill Clean-up Protocol

Title: Contaminated Equipment

H 2 O 2 Bio-Decontamination and Aseptic Transfer of Heat Sensitive Materials Sergio Mauri, Director, Global Marketing and Business Intelligence

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Health, Safety, Security and Environment

Walk in Modular Material Transfer Chamber Including Integration of a Bioquell Clarus L2 hydrogen peroxide vapour (HPV) generator

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

Standard Operating Procedure

Section 1. Contact Information. Procedure Title: Procedure Author: Date of SOP Creation/Revision: Name of Responsible Person: Location of Procedure:

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

1. The laboratory supervisor must enforce the institutional policies that control access to the laboratory.

UNH Department of Forensic Sciences

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 022 MOD: 1st Issue Page: 1 of 8

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Semi-annual BRD Checklist. Inspection Location(s) P.I. Name. Office Telephone : Contact Telephone : Department. Survey Date : Reviewed Date :

PPE Refresher- Levels of Protection

Ebola Virus Disease PPE Checklist/Sign In-Out Sheet Higher Transmission Risk Option 2: PAPRS

Newport News Shipbuilding Contractor Environmental, Health and Safety Resource Manual Sewage

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

PERSONAL PROTECTIVE EQUIPMENT FOR CHEMICAL EXPOSURES

LABORATORY HAZARD AWARENESS TRAINING

Biological materials manipulated in the laboratory: Bacteria Virus Protozoan

Model XSMKIT. Operations and Instructions WARNING

Personal Protective Equipment

Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE

Respiratory Protection. Program

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Laboratory Standard Operating Procedure: Acutely Toxic Substances

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Tools to Enhance Laboratory Biosafety and Biosecurity Performing Risk Assessments

OPERATIONAL GUIDELINE P R O C E D U R E

Risk Analysis and Hazard Reduction Report V1.0

Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists

Compliance Requirements

EHS-SWP-140. Safe Work Practice. Animal Projects with Chemicals. 1.0 Hazard Description

Using Vaporized Hydrogen Peroxide

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

THE UNIVERSITY OF WESTERN ONTARIO OCCUPATIONAL HEATH & SAFETY

UCSC Laboratory Standard Operating Procedure (SOP) Compressed Gas Cylinder Change for MOCVD and CVD Systems

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Standard Operating Procedure

Hazardous Materials Spill Response

ASSOCIATED DOCUMENTS:

Standard Operating Procedure

Laboratory Standard Operating Procedure: Specimen Preservatives

Viral Haemorrhagic Fever (VHF) - The correct order for donning and the safe order for removal and disposal of Personal Protective Equipment (PPE)

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

Laboratory Inspection Checklist

LABORATORY SAFETY INSPECTION

CHESTERFIELD COUNTY FIRE AND EMERGENCY MEDICAL SERVICES PROCEDURES

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

/16/05 11:24 PM Page 1 DECON IN A BAG. Printed on waterproof paper.

Phalanx Alpha Phalanx Beta and Ultra Elite

Standard Operating Procedures (v5 5/1/17)

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Laboratory Standard Operating Procedure: Sensitizers

Biological Safety Cabinet Guidelines

Hazardous Materials Spill Response

Laboratory Standard Operating Procedure: Carcinogens

Scarborough Fire Department. Personnel Protection Equipment

Presented by ARAMSCO

Webinar Expert Module 1: Garment Logistics and Gowning. Dupont September GOP-Innovations

Personal Protective Equipment

Safety Tips for Using Germicidal Lamps

Transcription:

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA SOP#: 1016.1 Date Issued: 3/16 Date Revised: 8/17 Page 1 of 6 TITLE: SCOPE: RESPONSIBILITY: PURPOSE: Animal Care Personnel Facility Manager and Technical Staff To Outline the Proper Procedures for Decontamination of Animal Research Facilities and Equipment I. PURPOSE 1. This procedure outlines the proper procedures to be followed for high-level disinfection of animal facility housing rooms, procedural areas, surgical suites, labs, necropsy areas, and equipment. II. RESPONSIBILITY 1. It is the responsibility of the Facility Manager or designee to ensure that all technical staff performing decontamination are adequately trained in the following procedures and these procedures are adhered to. 2. It is the responsibility of the technical staff assigned to decontamination procedures to read, understand, and follow the procedures outlined below. 3. It is the responsibility of the technical staff assigned to decontamination procedures to read and understand the information provided in the Bioquell Hydrogen Peroxide Sterilant SDS. III. GENERAL SAFETY PROCEDURES 1. High-level disinfection of facilities/animal housing is accomplished using a high quality 35% w/w hydrogen peroxide (e.g., medical or food grade) and a Bioquell Z-2 VHP Generator System in accordance with SOP #1162. 2. Hydrogen peroxide (HP) is a strong oxidizer and is irritating to the eyes, skin, and mucous membranes. It is imperative that all personnel using HP wear the appropriate personal protection equipment. a. Protective eyewear (e.g., goggles or face shield) must be worn when performing procedures that could result in HP coming in contact with the eyes. b. Protective eyewear, impervious sleeves and gloves (e.g., neoprene or vinyl) are required when handling concentrated HP solutions (i.e., changing or filing bottles). c. Wash hands after handling HP. d. Flush skin/eyes with water if come in contact with HP. e. HP spills should be cleaned-up with water.

Page 2 of 6 f. If you must enter an area briefly during or immediately after fogging with HP, Tyvek coverall with hood and boots (or long sleeves, long pants, hair cover and shoe covers), gloves, snug-fitting goggles, and half-face respirator with organic vapor filters and a particulate filter (e.g., 3M 6000 half face-piece respirator assembly with 3M 6001 Organic Vapor cartridges and a 5n11 or 5P71 particulate filter) are required. 3. HP should be stored in the dark at ambient room temperature. IV. BIO-DECONTAMINATION PROCEDURES 1. Common procedural areas are decontaminated in accordance with SOP #1015 Decontamination of Common Procedural Areas and as needed using the Bioquell Z-2 Hydrogen Peroxide Vapor Generator System. Animal housing areas are decontaminated in accordance with SOP #016 Animal Room Preparation as they become empty. 2. Thoroughly read and understand all manufacturers instructions and observe all Cautions and Warnings prior to using any equipment or solutions. See SOP #1162 Bioquell Z-2 Hydrogen Peroxide Vapor Generator System. 3. HP is a surface decontaminant and may not penetrate dirt and detritus. Heavily soiled surfaces should be cleaned prior to decontamination with VHP. Microorganisms present in gross contamination (e.g., excessive dust, dirt, feces) could possibly survive the bio-decontamination process. 4. Remove all personnel and animals from area to be contaminated as well as any equipment and materials that are not compatible with VHP and high levels of moisture. Trash/waste receptacle contents must be bagged, sealed and left in place for surface decontamination prior to being removed from the room. 5. Determine the cubic volume of space to be decontaminated (length x width x height in feet) using the laser measuring device stored in the lectern. This information will be uploaded and stored, for future use, into the VHP generator. 6. Shut off HVAC to area to be decontaminated when possible. If HVAC cannot be shut off then all HVAC supplies, returns, dampers, and thimbles, where present, must be sealed to ensure no vapor leaves the area. 7. Open all cabinet doors, drawers, and doors to suites and minimize occluded/covered surfaces to facilitate penetration of VHP. 8. While absorbable materials can remain in the room during bio-decontamination (e.g., paper, clothing, fabrics, etc.) the presence of a large quantity of absorbable material will extend gassing time and aeration time to account for peroxide absorbed. 9. Remove any materials that may be incompatible with HP (e.g., open chemicals and medicines).

Page 3 of 6 10. Turn off equipment that may operate above or below ambient room temperature (e.g., autoclaves, incubators, refrigerators, and cold rooms) and allow them to return to ambient room temperature prior to cycle initiation to ensure VHP distribution. 11. Bioquell VHP-CI (chemical indicators) are used during each room decontamination process to assess the distribution of VHP within the room. The CI will change color and fades from blue towards white when exposed to the parameters (i.e., time, concentration and micro-condensation) of the VHP surface decontamination process. a. Avoid skin and or liquid contact with the indicator portion of the CI when handling/placing. b. Since VHP is heavy, CIs should be placed throughout the room, high on the wall in corners at the wall/ceiling junction, and the farthest distance from the VHP generator. c. CIs can also be placed in drawers, biological safety cabinets, and within equipment to evaluate the VHP distribution and surface decontamination. CIs should be placed deep within drawers, and on surfaces not directly exposed to VHP to challenge the efficacy of decontamination. d. CIs are labeled to identify their location in the room with permanent marker on the printed-side of the card, away from the indicator portion. For wall/ceiling interface placement, number the CIs beginning with #1 from the corner immediately on your left as you enter the rooming and continuing consecutively around the room to the last corner. e. CI cards should be used within 14 days after opening foil package. 12. HP biological indicators (BI) are used to validate efficacy of the biodecontamination cycle. a. BI should be stored refrigerated at 2-8 0 C. b. Since VHP is heavy, BIs should be placed in the room, high on the wall in corners at the wall/ceiling junction, and the farthest distance from the VHP generator. c. BIs can also be placed in drawers, biological safety cabinets, and within equipment to evaluate the VHP distribution and surface decontamination. BIs should be placed deep within drawers, and on surfaces not directly exposed to VHP to challenge the efficacy of decontamination. d. BIs are labeled to identify their location in the room with permanent marker on the upper right-hand corner of printed-side of the Tyvek pouch. For wall/ceiling interface placement, number the BIs beginning with #1 from the corner immediately on your left as you enter the rooming and continuing consecutively around the room to the last corner. e. Tape the BIs on the wall with the writing side of the Tyvek pouch facing up and folded so that the indicator disc is parallel to the floor. f. Masking tape can used to affix BIs to surfaces/equipment. g. One BI will serve as control and should not be exposed to VHP. 13. Place the Z-2 generator in the center of most rooms for even VHP distribution. Other positioning may be required for alcoves or side rooms are connected to the main room. 14. The Bioquell R-30 unit is used to aid in the distribution of VHP and for aeration of the room to remove VHP after decontamination.

Page 4 of 6 a. When using the unit for aeration only, place unit so that air can flow, unimpeded into all six filters. Blocking filters will prolong the aeration process. b. When using the unit to aid in VHP distribution, the front of the unit is positioned so that the fans are directed toward side rooms, alcoves or areas not in the line of sight of the VHP generator. 15. Changing stations, Class A2A laminar flow hoods, and equipment that recirculates air can be left ON during the cycle to obtain a more thorough decontamination of the equipment. However, if equipment contains internal filtration, aeration may need to be extended to counteract absorption into the filters. 16. To decontaminate hard ducted BSCs during room decontamination: a. If sash can be left open without creating excessive draw, leave power ON. b. Shut OFF power at the breaker. c. Turn unit on at breaker when room is fully saturated for a minute or two to draw VHP into the unit. d. Turn unit OFF at breaker after a couple minutes. e. At the end of the VHP cycle the BSC can be turned on again at the breaker to aid in aeration of the room. 17. Check the area again for people, ensure all doors are shut and secured, that all possible openings where significant amounts of gas could escape are sealed, and the ventilation is off or the ductwork/thimbles are sealed. 18. Check that the hand-held low level H 2 O 2 sensor (stored in the lectern) is fully charged. 19. Place the flat cable that connects the lectern to the VHP generator under the door carefully, so as not to damage the cable, as you shut the door and leave the room. 20. Seal outer door edges with tape. Bioquell sells tape however most any tape will work (e.g., paper, masking, or duct tape). Use the hand held H 2 O 2 sensor during first 10 minutes of the VHP gassing cycle to test seals at bottom of door to ensure it is properly sealed. 21. Follow the procedures described in SOP #1162 Bioquell Z-2 Hydrogen Peroxide Vapor Generator System to start VHP decontamination and aeration. 22. When aeration begins hard ducted biosafety cabinet can be started at the breaker to speed-up the process. 23. After the appropriate aeration time, the screen will display Aeration Target Achieved Check Concentration <1ppm Before Ending Cycle. Use the hand-held low HP sensor to check the area s actual HP concentration. 24. Place the handheld sensor inside the door for a few minutes, then retrieve the sensor. 25. If the displayed level is <1ppm it is safe to end the cycle and enter the room. 26. If the handheld HP reads >1ppm the sensor will give both audible and visual alarms. Let the unit continue to aerate and repeat testing until <1ppm is achieved.

Page 5 of 6 27. When 1ppm is reached, stop the cycle by pressing END CYCLE button (password required). 28. Enter room adhering to appropriate practices to prevent re-contamination of the area (e.g., appropriate PPE, essential personnel and work flow). 29. Remove any HVAC plenum and thimble covers. 30. Wearing gloves retrieve all CIs, and BIs when used, from the room. VI. VALIDATION 1. Inspect CIs to ensure adequate color change. CIs change color in the presence of HP by fading from blue towards white. a. CIs provide a crude assessment of vapor distribution by visually comparing the degree of color change. b. The color of the CI should be compared with each of the 2-log, 4-log, 6-log and >6-log printed reference colors on the product insert sheet. c. The color change gives an indication of the progressive bioburden reduction. d. CIs should be used for indicative purposes only and not as a direct replacement for BIs. 2. BIs are the industry standard method for validation of hydrogen peroxide biodecontamination. Preparing BI for incubation: a. While wearing gloves collect BIs and place in a sealable plastic bag. b. Ideally BI disk transfer to growth media should be conducted in a BSC. Disinfect inside of BSC with a sporicidal disinfectant (e.g. Sporicidin) and allow surface to dry c. Label trypticase soy broth (TSB) tubes (Fisher Scientific cat # BB21093, stored between 5-25 0 C) to coincide with BI pouch labeling and date. In addition label one TSB tube positive control and one tube negative control. d. Remove BIs from the plastic bag and transfer the BIs to their corresponding TSB tube using the pinch and peel method described below: 1. While wearing gloves, select the corresponding TSB tube. 2. Unscrew cap until freely spinning, DO NOT REMOVE CAP from tube. 3. With thumb and forefinger, pick up corresponding BI pouch, ensuring the small hole is at the bottom. 4. Using the other thumb and forefinger, pinch and flex the sides of the indicator pouch so that the metal tab drops to the bottom of the pouch. 5. Ensuring the BI disc can be felt between both thumbs; hold the flaps of the BI pouch between thumbs and forefingers. 6. Holding the pouch directly over the top of the tube, use the third and fourth finger of one hand to carefully lift the cap and hold to one side of the tube. 7. Apply pressure to the wing tabs to open pouch. Use thumbs to control the metal tab and direct it to fall into the tube ensuring that neither the tab nor the pouch touches the tube during the transfer. 8. While still holding the cap between the third and fourth finger, replace cap on tube.

Page 6 of 6 9. Dispose if tyvek pouch. 10. Tighten TSB tube cap. e. After all exposed BI have been transferred, prepare the positive control by transferring a BI tab from a pouch that has not been exposed to VHP following the pinch & peel technique described above. f. The negative control is an unopened tube that contains only TSB. g. Incubate all the tubes containing BIs including the negative control at 60 0 C + 2 0 C. h. Record the time and date incubation is initiated directly on the tube. 3. Contaminated media tubes, caps, or BI tabs (i.e., touched by outside of pouch or dropped during transfer) should be noted in the Comments section of the Bioquell VHP Decontamination Record. Caps that are dropped can be replaced with a cap from a spare/extra tube. 4. Incubation and interpretation: a. BIs should be examined after overnight (>18 hours) incubation to give an initial indication, and after 7 days to confirm the final results. b. Turbidity indicates spore growth. Turbid media in test vials indicates VHP was not effective in achieving complete bio-decontamination. c. Positive controls should be turbid. Lack of turbidity indicates a problem with the BIs. d. Negative controls should be clear. Turbid liquid indicates a problem with the sterility of the media. 5. Results of CIs and BIs are recorded on CMDC # 217 Bioquell VHP Decontamination Record. 6. Z-2 printed report tapes and the Bioquell VHP Decontamination Record are maintained with the facility sanitation records for a period of 6 months. 7. The facility manager or their designee will submit the Bioquell VHP Decontamination Record to the Microbiological Monitoring Program Manager at the end of the month following decontamination procedures. VII. REFERENCES 1. Bioquell Z-2 Hydrogen Peroxide Vapor Generator System User Manual. 2. Bioquell R-30 Aeration Unit User Manual. 3. Bioquell Hydrogen Peroxide SDS. 4. Bioquell SOP #7 entitled Biological Indicator Handling and Positioning. 5. For additional information contact Bioquell Technical Support at (215) 682-0225 Approved: Date: