Inspection Chambers Project

Similar documents
Inspection Chambers and Covers

KlassikDrain Section. Technical Handbook and Product Catalog. General purpose trench drainage

Lecture 10 : Sewer Appurtenances

104 Chamber System Ostendorf. Ostendorf. Chamber System ISO RV-Systém OSMA

PowerDrain Section S100K/S200K/S300K ACO DRAIN. Introduction Pgs 1-13 Selecting the right product

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

CAISSON SHAFT SYSTEM

KlassikDrain Section K200/K300 ACO DRAIN. Introduction Pgs 1-13 Selecting the right product

FP McCann Tunnels and Shafts 1

ACO External Drainage

Indiana LTAP Road Scholar Core Course #10 Culvert Drainage. Presented by Thomas T. Burke, Jr., PhD, PE Christopher B. Burke Engineering, Ltd.

Egatube Conduit and Fittings

EUROFLO CULVERT PIPE. Fittings / Pipes

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

ASME BPE 2014 DT Range of Bioprocessing Fittings

Pressure reducing valves Index

THE PROCESS OF JOINT INTEGRITY

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

Hynds Manhole System. Technical Guide D4.1

1805 Series Relief Valves

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features.

pdf WATER RETICULATION STANDARD VENTILATION LOUVRE BOXES SINGLE AND DOUBLE DUCT SYSTEMS

2-port and 3-port valves PN 16

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Manual retractable fitting with safe-to-operate rotary drive

Gas Pressure Regulator HON 502

Vertical and Horizontal Bladder Tanks

Pneumatic retractable fitting for simple commercially available control units or process applications

Installation, operation & maintenance manual - original version

Model MTB-ASME Vertical Bladder Tanks

tunnels & shafts brochure

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

Model MTB-ASME Vertical Bladder Tanks

Bermad Model:

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Minnesota

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Rhode Island

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Norval Pressure regulator

APG001. Application Guide for Gas. T: F: E:

GRP Manholes and Chambers. for Gravity and Pressure Applications

CALEFFI. Ball zone valves. series /03 GB

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Float operated valve TYPE (SWDS)

CLASS TLP Pressure Reducing Valve

Aperval Pressure Regulators

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Horizontal Bladder Tanks

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

PRESSURE REGULATOR LBM SERIES

Vertical Bladder Tanks

mullen shower base LIFE TIME Suitable for: ALL Floor Types Floor Coverings V Vinyl Wood Flooring Concrete Slab C Ceramic Tiles

CLEANING, INSPECTION, AND TESTING OF SEWERS

Sewer. Contents. Stormwater: Box Culverts. Manhole Bases...2 Access Chambers...3 Make Up Rings...4 Covers...6 Septic...10 Sewer Sundries...

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

SEries 29 Hydrant valves installation, operation & maintenance manual

Safety shut-off valve Control Control Lock-up Over pressure set point Under pressure set point pressure range accuracy class

Pressure Reducing Valve for Steam Type 2333 A

HIGH-PRESSURE RELIEF VALVES

Gas plug-in hose, straight-through form. Instructions for Use. suitable for gas socket model G2019T, G2016T. G2023 from 01/1990.

2-port and 3-port seat valves, PN16

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Solenoid valves VZWF, force pilot operated

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Reservoir End Covers Type EC

Delta Dual V3 (DMS-164) Installation Instructions For Ground Water Applications T. E. W

Model MTB-ASME Horizontal Bladder Tanks

Expert Hydrostatic Level Transmitters

Safety Shut-Off Valve HON 720

EUROFLO CULVERT PIPE. Fittings / Pipes

CHAPTER 5 CULVERT DESIGN

PERKFILTER. Inspection and Maintenance Guide

R-3501-E2 R-3501-H4. R-3501-HL Mountable Curb Frame, Grate

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

SECTION PRESSURE TESTING OF PIPING

Norval Pressure Regulators

EnerVal. Technical data litre storage capacity. Buffer storage vessels

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

Blowdown vessels Meeting the requirements of HSE PM60

Hand winch MANIBOX VS

Series 100 Slam Shut Valve. Technical Bulletin

Two-port valves, male threaded, PN25

VORTEX REGULATOR Type WAB (UCY / CY-F / CE/V)

Technical Service Bulletin 10001

SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S

Industry Guidelines POLYETHYLENE (PE) PIPES AND FITTINGS FOR COMPRESSED AIR ISSUE 6.8

Flow control valves Series RFU - RFO 2/

Engineering Data Sheet

SECTION BUTTERFLY VALVES

BERMAD Waterworks. Level Control Valve with Bi-Level Vertical Float. 700 Series Model B. Features and Benefits. Major Additional Features

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Hand winch MANIBOX GR

MEASURING INSTRUMENTS Pressure Gauge T-Piece...77 Pressure Gauge TC 25.0, connection below...78 Pressure Gauge TC 25.0, connection behind...

Transcription:

Inspection Chamber Project Details Project Name Inspection Chambers Project Client Name Wavin Site ddress Parsonage Way, Chippenham, SN15 5PN Produced y dmin 3 Date 29/03/2017 Your components - Calc Ref 1 Reference Calc Ref 1 Incoming Pipe OsmaDrain 110mm Depth 1.3m doptable/non-doptable doptable Outgoing Pipe Diameter 110mm How many properties to serve? Up to 3 properties Range 315 D/S Equal Inspection Chamber ase 34NE300 Range 315 Inspection Chamber lso for use with 150mm UltraRib, using daptor 6UR141 Part Number : 34NE300 Nominal Size(mm) C D E F G 110 514 369 387 110 357 238* 103 * Dimension F = height at centre point of base (all bases have a 15 inlet-to-outlet fall) 315mm dia. base incorporating straight channel and single inlet For use with 110/160mm plastic pipework Range 315 Cover by others Range 315 Inspection Chamber Covers are required to be 12.5 tonnes (125) to comply with Sewers for doption 7th Edition. These will need to be sourced from a cast iron cover manufacturer. Range 315 P/E Inspection Chamber Shaft Range 315 Inspection Chamber Part Number : 30NE002 315 315 2000* * Dimension = effective height 315mm dia. plain-ended corrugated shaft Length: 2 metres For use with all Range 315 bases

Product information - Calc Ref 1 Range 315 Inspection Chamber Description 315mm diameter polypropylene inspection chambers for adoptable and nonadoptable applications. Compliant with Sewers for doption 7th edition [Sf7]. Choice of eight base configurations for equal pipe connections. For use directly with either 110/160mm plastic pipework or 150mm UltraRib system via the appropriate adaptor (6UR141). 315mm diameter shaft may be cut to length to achieve required invert down to a maximum of 2 metres. pplications For above ground access and maintenance inspection of buried pipework down to 2 metres deep For loading applications: 15 (1.5 tonnes) 125 (12.5 tonnes) * D400 (40 tonnes) * * With cover & frame supported by concrete plinth Key Dimensions Invert depth of base: 238mm [for 110mm system] 290mm [for 160mm system] External shaft diameter: 315mm Shaft length: 2m Maximum installation depth: 2m Key Features & enefits Fast, easy installation: no wet trades Lightweight: no lifting equipment required Reinforcing ribs on underside to withstand groundwater pressure Shaft can be cut to required length No additional trench excavation required Compliance Range 315 chambers comply with the following standards and regulations

S EN 13598-2: 2009 Sf7 Typical Chamber Detail Type 4: (Non-entry. Maximum depth from cover level to soffit of pipe: 2m) uilding Regulations Part H1: Shallow only to maximum depth 0.6m Your components - Calc Ref 2 Reference Calc Ref 2 Incoming Pipe Depth 2m Outgoing Pipe Diameter 225mm Twinwall 225mm doptable/non-doptable Non doptable Range 600 D/S Equal Inspection Chamber ase 69NE314 Range 600 Inspection Chamber Part Number : 69NE314 C D E 225 798 720 225 750 705 600mm dia. base incorporating bent 90 channel and single inlet For use with 150mm, 225mm and 300mm UltraRib lso for connection to 150mm, 225mm and 300mm TwinWall using daptors 6TW145 (with 150 ase), 9TW145 (with 225 ase) or 12TW145 (with 300 ase) Range 600 Cover by others Range 600 Inspection Chamber Covers are required to be 12.5 tonnes (125) to comply with Sewers for doption 7th Edition. These will need to be sourced from a cast iron cover manufacturer. Range 600 P/E Inspection Chamber Shaft Range 600 Inspection Chamber Part Number : 60NE003 600 683 3000* * Dimension = effective height 600mm dia. plain-ended corrugated shaft Length: 3 metres For use with all Range 600 bases

ccessories daptor 9TW145 Part Number 9TW145 ccessories Restriction ccess Cap 60NE930 For use with 60NE300 shaft Restricts access to 350mm Supplied with one 600mm sealing ring Part Number 60NE930 600 704 270

Product information - Calc Ref 2 Range 600 Inspection Chamber Description 600mm diameter polypropylene inspection chamber for adoptable and nonadoptable applications. Compliant with Sewers for doption 7th edition [Sf7]. Choice of twelve bases for equal pipe connections. For use directly with 150mm, 225mm and 300mm UltraRib system. 600mm diameter shaft may be cut to length to achieve required invert down to a maximum of 3 metres. pplications For above ground access and maintenance inspection of buried pipework down to 3 metres deep For loading applications: 125 (12.5 tonnes) * D400 (40 tonnes) * * With cover & frame supported by concrete plinth Key Dimensions Invert depth of base: 646mm [for 150mm system] 705mm [for 225mm and 300mm systems] External shaft diameter: 683mm Shaft length: 3m Maximum installation depth: 3m Key Features & enefits Fast, easy installation: no wet trades Lightweight: no lifting equipment required Reinforced base plate to withstand groundwater pressure Shaft can be cut to required length ll inlets and outlet sockets allow 7.5 movement in all directions Compliance Range 600 chambers comply with the following standards and regulations S EN 13598-2: 2009 Sf7 Typical Chamber Detail Type 3: (Non-entry. Maximum depth from cover level to soffit of pipe: 3m) uilding Regulations Part H1: Shallow and/or Deep Your components - Calc Ref 3 Reference Calc Ref 3 Incoming Pipe OsmaDrain 110mm Depth 0.95m doptable/non-doptable doptable Outgoing Pipe Diameter 110mm How many properties to serve? Up to 3 properties UIC D/S Equal Inspection Chamber ase 4D922

Universal Inspection Chamber Part Number : 4D922 *Note: dimension F = height at centre point of base (all bases have a 15 inlet-to-outlet fall) Nominal Size(mm) C D E F 110 595 595 470 110 476 295* 450mm dia. base incorporating straight channel and 5 inlets including 2 x 45 and 2 x 90 equal branch inlets For use with 110mm OsmaDrain Supplied with 3 blank-off plugs for unused side entries UIC Round Cover & Frame 125 4D942 Universal Inspection Chamber Part Number : 4D942 C D - 522 462 70 35 For medium duty loaded locations For loadings up to 125kN (12.5 tonnes) when frame is supported by a concrete plinth Material: Ductile Iron UIC P/E Inspection Chamber Shaft Universal Inspection Chamber *Note: dimension = effective height Part Number : 4D975 You may require multiple shaft parts for the depth of your chamber. See below for details: 1 shaft = 605mm 2 shafts = 910mm 3 shafts = 1.2m 450 500 305* 450mm dia. plain-ended shaft. Length: 305mm For use with all Universal bases Supplied with integral, co-injected, elastomeric seal

Product information - Calc Ref 3 Universal Inspection Chamber Description 450mm diameter polypropylene inspection chamber for adoptable and nonadoptable applications. Compliant with Sewers for doption 7th edition [Sf7]. Choice of five base configurations for equal and unequal pipe connections. ase configurations available for use with either 110/160mm OsmaDrain or 150mm UltraRib. Shaft may be assembled to required invert depth by using shaft sections 4D975 (maximum 1.2m). pplications For above ground access and maintenance inspection of buried pipework up to 1.2 metres deep Key Dimensions Height of bases: 295mm [for 110mm system] 270mm [for 150mm and 160mm systems] External shaft diameter: 450mm Shaft section length: 305mm Maximum installation depth: 1.2m Key Features & enefits Fast, easy installation: no wet trades Lightweight: no lifting equipment required Push-fit shaft sections: one or more can be used to achieve required invert depth Final shaft section can be cut to required length No additional trench excavation required Square cover and frame for use with 4D975 shaft in situations requiring loading up to 15kN (1.5 tonnes) Compliance Universal Inspection Chambers comply with the following standards and regulations S EN 13598-1: 2010 Sf7 Typical Chamber Detail Type 4 (to max. 1.2m depth only) uilding Regulations Part H1: Shallow only, to maximum depth of 1.2m