JPR Task(s): Roll Fire Hose OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-31 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing PPE and provided a section of fire hose, shall demonstrate a straight hose roll and a donut hose roll." Minimum PPE: Helmet and Gloves PERFORMANE andidate must successfully pass this skill in 10 minutes to pass Straight Hose Roll 1. Lays hose out straight and flat. 2. Beginning with the male coupling, begin to roll the hose forming an even, uniform roll. 3. Roll increases in size and concludes with the female coupling finishing the outside. Donut Hose Roll 4. Lays hose out flat. 5. Begins near the center of the section, several feet nearer to the male end. 6. oils the hose, working toward the male end. 7. Upon reaching the male, takes the excess hose of the female end and wraps the roll covering the male coupling to complete the roll. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 5 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.5.2
JPR Task(s): Loading Hose onto Apparatus OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-32 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing PPE and provided with an assistant, shall demonstrate the assigned Accordion, Flat, or Horseshoe Hose Load with 4 sections of hose." Minimum PPE: Helmet and Gloves PERFORMANE andidate must successfully pass this skill in 15 minutes to pass 1. Starts the hose load in the bed, on edge, against the partition. 2. ontinues the load, front to back, on edge. 3. Ensures connections are tight, in line and arranged to deploy smoothly. 4. Transitions to the next tier, when appropriate, and continues until 4 sections are loaded. Flat Hose Load or 1. Starts the hose load with the male coupling in corner, hose flat, against the partition. 2. ontinues to load hose flat, front to back, working across the bed to opposite partition. 3. Ensures connections are tight, in line, and arranged to deploy smoothly. 4. Transitions to the next layer, upon reaching opposite partition, and continues until 4 sections are loaded. Horseshoe Hose Load 1. Starts the hose load in the bed, on edge, against the partition. 2. ontinues the load, on edge, around the perimeter of the bed, working to the middle. 3. Ensures connections are tight, in line, and arranged to deploy smoothly. 4. Transitions to the next tier, when appropriate, and continues until 4 sections are loaded. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 3 Accordion Hose Load or Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.5.2
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION JPR Task(s): Advance Uncharged Hose Line Up Interior Stairs andidate #: Skill No. 1-33 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, in full PPE and on SBA air, shall demonstrate advancing a hose line, uncharged, up a flight of stairs." Minimum PPE: Full PPE with SBA PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. onfirms order with officer to advance the line. 2. andidate goes on air before entering structure. 3. Shoulders adequate amount of hose line and advances to the fire floor. (Assistance provided to feed hose up the stairway behind the candidate) 4. andidate flakes off hose up the stairway leading above the fire floor to make fire floor advance easier. 5. Arranges hose to sides of stairwell to provide for clear traveling path. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 4 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.10
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY JPR Task(s): Load and Deploy Pre-connected Hand line FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-34 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and, provided a pumper, an assistant, and 3 sections of hand line hose, shall demonstrate loading for use and deploying a pre-connected hand line from the apparatus." Minimum PPE: Gloves and Helmet PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. Attach female coupling to the discharge outlet. Flat Hose Load, 2. Lay the first length of hose flat on the hosebed next to the sidewall. 3. Angle the hose to lay the next fold adjacent to the first fold, continue building first tier. 4. Make a fold that extends approximately 8" beyond load point that is one-third the total length of the hose, this will later serve as a pull handle. 5. ontinue laying the hose in the same manner, building each tier with folds laid progressively across the bed. 6. Make a fold that extends approximately 14" beyond the load at a point that is approximately two-thirds the total length of the load. 7. omplete the load, attach the nozzle, and lay it on top of the load. Triple Layer Hose Load or, 2. Extend the hose in a straight line to the rear. 3. Pick up the hose at a point two-thirds the distance from the tailboard to the nozzle. 4. arry this hose to the tailboard. Using several firefighters, pick up the entire length of the three layers. 5. Begin laying the hose into the bed by folding over the three layers into the hose bed, fold the layers over at the front of the bed. 6. Lay them back to the rear on top of the previously laid hose. 7. ontinue to lay the hose into the bed in an S-shape configuration until the entire length is loaded. Optional: Secure the nozzle to the first set of loops using a rope or strap if desired. Minuteman Hose Load 2. Lay the hose flat in the bed to the front, lay the remaining hose out the front of the bed to be loaded later. 3. ouple the remaining hose sections together, attach nozzle to the male end. 4. Place the nozzle on top of the first length at the rear, angle the hose to the opposite side of the bed, and fold to the rear. 5. Make fold at the rear of the bed and angle the hose back to the other side and make a fold to the front. 6. ontinue loading hose to alternating sides of the bed in the same manner until complete length is loaded. 7. onnect male coupling of first section to the female coupling of the last section and lay remainder of first section in the same manner. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 5 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.5.2, 5.3.10
JPR Task(s): Extend a harged Hose Line OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-35 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and provided a charged hose line, hose clamp and a spare section of hose, shall demonstrate extending a hose line." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. andidate directs assistant to slightly flow nozzle. 2. alls for hose line to be shut down. 3. Removes nozzle. 4. onnects the new section of hose. 5. Reattaches nozzle. 6. Recharges hose line. 7. Bleeds air from hose line. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 5 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.10
JPR Task(s): Replace Burst Hose Section OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-36 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and provided a charged hose line and a spare section of hose, shall demonstrate replacing a burst section of hose." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. alls for hose line to be shut down. 2. Removes burst section of hose. 3. ouples replacement section(s) of hose, uses proper coupling techniques. 4. Directs line to be recharged. Bleeds air to achieve water flow. 5. Notifies officer line is back in service. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 4 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.10
JPR Task(s): Operate ombination Nozzle OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-37 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and provided with an assistant, shall demonstrate operation of a combination or fog type nozzle, adjusting patterns and stream while maintaining control of the hose line." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. Positions self and assistant on same side of hose line. Evaluator advises candidate to demonstrate straight stream 2. Adjusts nozzle to straight stream. 3. Opens nozzle fully and controls hose line. 4. Slowly closes nozzle to avoid water hammer. Evaluator advises candidate to demonstrate narrow fog stream 5. Adjusts nozzle to a narrow fog stream. 6. Opens nozzle fully, controls hose line, and achieves 15-45 degree pattern. 7. Slowly closes nozzle to avoid water hammer. Evaluator advises candidate to demonstrate wide fog stream 8. Adjusts nozzle to a wide fog stream. 9. Opens nozzle fully, controls hose line, and achieves 45-80 degree pattern. 10. Slowly closes nozzle to avoid water hammer. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.10
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY JPR Task(s): Deploy and Operate Master Stream Device FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-38 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE, shall demonstrate deployment, set up, and operation of a master stream device, with an assistant directed by the candidate." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 15 minutes to pass 1. onfirms order with officer to set up master stream device. 2. Assembles necessary tools, hose and appliances for set up. 3. With assistance, places master stream device (monitor) into position. 4. Secures device as necessary. 5. Deploys hose lines and connects to device. 6. Ensures connections are tight. 7. Sets nozzle to desired level, directs engineer to charge line(s). 8. Steadies the monitor, signals to shut down if unstable. 9. Demonstrates directing stream. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.8
JPR Task(s): Attack/ontrol a Vehicle Fire OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-39 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and SBA, shall select the proper hose line and shall demonstrate appropriate procedures for extinguishing the vehicle fire." Minimum PPE: Full PPE with SBA PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. onfirms order with officer to attack vehicle fire, chock wheels at earliest convenience. 2. onfirms all crew members have full PPE and are breathing air. 3. Identifies what fuel type vehicle operates. 4. hooses appropriate hose line for the task.(booster line not acceptable) 5. Ensures line is charged or directs line be charged, expels air, checks stream pattern. 6. Sets nozzle to moderate fog stream. 7. Advances to vehicle at 45 degree angle, from upwind and uphill if possible. 8. Extinguishes fire around or under vehicle first. 9. Approaches passenger compartment, knocks down fire and or checks for victims. 10. Approaches engine compartment, checks for extension, extinguishes fire if necessary. 11. Approaches trunk compartment, checks for extension, extinguishes fire if necessary. 12. hecks for leaking fuel and other hazards. ontrols as necessary. 13. Overhaul vehicle. Preserves potential fire cause evidence. 14. Report to officer fire is under control/out. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 10 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.7
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY JPR Task(s): Extinguish Trash ontainer Fire FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-40 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and SBA, and provided a partner and hose line, shall demonstrate appropriate procedures for extinguishing the container fire." Minimum PPE: Full PPE with SBA PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. onfirms order with officer to attack container fire. 2. onfirms all crew members have full PPE and are breathing air. 3. lears air from nozzle. 4. Advances to container and verbalizes inherent dangers with interior contents. 5. ools container with straight stream and protects any exposures. 6. Attacks the fire in container with medium fog pattern until it is knocked down. 7. Directs partner to probe with pike pole and break up material. 8. Extinguishes any hotspots. 9. Performs thorough overhaul. 10. hecks for any extension to exposures, controls if necessary. 11. Ensures fire is completely extinguished. Initial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 8 Evaluator 1 Evaluator 2 requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.8
JPR Task(s): Turn Off Utilities OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION Skill No. 1-41 PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The candidate, wearing full PPE and given simulation utilities props, shall demonstrate proper methods of shutting off residential gas, water, and electricity." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 5 minutes to pass Intial 1. onfirms order with officer to shut off utilities, assesses related hazards of each utility. 2. Demonstrates shutting off electricity at service panel. 3. Demonstrates shutting off natural gas at the meter. 4. Demonstrates shutting off water at the meter box. 5. Notifies officer tasks completed. "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 5 Evaluator 1 Evaluator 2 NFPA 1001, Standard for Fire Fighter Professional Qualifications, 2013 Edition. Requires all Firefighter 2 candidates to be competent in requisite skills and procedures as outlined by job performance requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.18
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION JPR Task(s): Attack Structure Fire Interior Grade Level andidate #: Skill No. 1-42 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and SBA, and provided with an assistant, shall demonstrate an appropriate aggressive attack on an interior structure fire at grade level." Minimum PPE: FULL PPE w/ SBA PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. onfirms order with officer to make interior fire attack. 2. hecks nozzle and bleeds air from line prior to entry. 3. Ensures all crew is breathing air appropriately. 4. Extinguishes any fire at or around doorway. 5. Advances hose line as necessary. Keeps hose to the side of exterior stairs. 6. Extinguishes fire by either direct, indirect, or combination attack as directed by officer. 7. Upon extinguishing fire, FF and crew will back out of the structure facing fire at all times. 8. Report to officer fire is under control/out. Intial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Evaluator 2 NFPA 1001, Standard for Fire Fighter Professional Qualifications, 2013 Edition. Requires all Firefighter 2 candidates to be competent in requisite skills and procedures as outlined by job performance requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.10
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION JPR Task(s): Attack Structure Fire Above Grade Level andidate #: Skill No. 1-43 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and SBA, and provided with an assistant, shall demonstrate an appropriate aggressive attack on an interior structure fire at above grade level." Minimum PPE: FULL PPE w/sba PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. onfirms order with officer to make interior fire attack. 2. hecks nozzle pattern and bleeds air from line prior to entry. 3. Extinguishes any fire at or around doorway. 4. Ensures all crew is breathing air appropriately. 5. Advances hose line as necessary. 6. Advances hose line up stairwell to fire floor, keeping the hose line to the side of the stairs. 7. Extinguishes fire by either direct, indirect or combination attack as directed by officer. 8. Upon extinguishing fire, FF and crew will back out of the structure facing fire at all times. 9. Report to officer fire is under control/out. Intial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 7 Evaluator 1 Evaluator 2 NFPA 1001, Standard for Fire Fighter Professional Qualifications, 2013 Edition. Requires all Firefighter 2 candidates to be competent in requisite skills and procedures as outlined by job performance requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.10
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION JPR Task(s): Attack Structure Fire Below Grade Level andidate #: Skill No. 1-44 PERFORMANE RITERIA AND INSTRUTIONS INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE and SBA, and provided with an assistant, shall demonstrate an appropriate aggressive attack on an interior structure fire at below grade level." Minimum PPE: FULL PPE w/sba PERFORMANE andidate must successfully pass this skill in 10 minutes to pass 1. onfirms order with officer to make interior fire attack. 2. hecks nozzle pattern and bleeds air from line prior to entry. 3. Ensures basement is ventilated prior to entry. 4. Extinguishes any fire at or around doorway. 5. Ensures all crew is breathing air appropriately. 6. Advances hose line into structure. 7. hecks integrity of stairs, evaluates fire conditions. 8. Advances downstairs quickly to minimize exposure to superheated gases/smoke. 9. Extinguishes fire by either direct, indirect, or combination attack as directed by officer. 10. Upon extinguishing fire, FF and crew will back out of the structure facing fire at all times. 11. Report to officer fire is under control/out. Intial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 8 Evaluator 1 Evaluator 2 NFPA 1001, Standard for Fire Fighter Professional Qualifications, 2013 Edition. Requires all Firefighter 2 candidates to be competent in requisite skills and procedures as outlined by job performance requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.10
OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION JPR Task(s): Extinguish Ground over (Wildland) Fire Skill No. 1-45 PERFORMANE RITERIA AND INSTRUTIONS andidate #: INSTRUTIONS TO THE ANDIDATE "The andidate, wearing full PPE, either structural or wildland, shall demonstrate control and/or extinguishment of a ground cover fire." Minimum PPE: Full PPE w/o SBA PERFORMANE andidate must successfully pass this skill in 15 minutes to pass 1. onfirms order with officer to attack fire. 2. Identify exposure threats based on fire spread potential. 3. Identify safe zones and escape routes. 4. Monitors weather conditions. 5. Monitors fire and smoke conditions. Direct Attack 6. Demonstrates proper fire attack using backpack pump. 7. Attacks from the black. 8. Demonstrates fire attack using proper fire swatter techniques. 9. Attacks from the black. 10. Demonstrates proper fire attack using hose line. 11. Attacks from the black. 12. Mops up hot spots, moves to safe area when extinguished or conditions worsen. Indirect Attack 13. Demonstrates proper use of fire rake. 14. lears ground well ahead of fire in green area and maintains integrity of fire line. 15. Maintains situational awareness, moves to safe area as conditions worsen. 16. Reports to officer upon completion of task. Intial "" Indicates a critical step. ure to complete this step constitutes failure of the station. Score needed to pass: 11 Evaluator 1 Evaluator 2 NFPA 1001, Standard for Fire Fighter Professional Qualifications, 2013 Edition. Requires all Firefighter 2 candidates to be competent in requisite skills and procedures as outlined by job performance requirements contained within hapter 5 of the standard, toward eligibility for certification. Objective(s): 5.3.19