Operation manual Oxygen sensor

Similar documents
Electrochemical Sensor

AMS 2710 PCB pressure sensor module with V output

Electrochemical Sensor

ME3-HCL Electrochemical sensor

Gas density monitor With integrated transmitter Model GDM-100-TI

O 2 SENSORS Zirconium Dioxide (ZrO 2 ) Oxygen Sensor Operating Principle Guide

PRELIMINARY DATASHEET

Transmitter CS 21 Operation Manual

AMS 6916 Board mount pressure sensor with ratiometric analog output

O3 3E 1 F Gas Sensor Module

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

M iniature Amplified Pressure Sensors

Technical Data Sheet MF010-O-LC

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

Precision pressure sensor Basic version Model CPT6020

AMS 6915 Board mount pressure sensor with digital output (I²C)

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Amplified Middle Pressure Sensors

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

[Instruments for vacuum measurement, checking and adjustment] 3

MANUAL KPS Pressure Control Valve

AMT-Ex Dewpoint Transmitter

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Transmitter CS 21 Operation Manual

SITRANS P measuring instruments for pressure

METROTEC GSM. Type GSM. Oxygen measurement and control unit. *** Version 1.6 ***

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Instruction and Maintenance Manual

MODEL GT820 OXYGEN SENSOR

OXY 3690 MP. Measuring transducer for air oxygen

Pressure Measurement Single-range transmitters for general applications

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Mass Flow Controller (MFC) for Gases

Application Note AN-107

Under pressure pushing down

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Model PDT Dewpoint Transmitter

SX150A. Features. Typical Applications. Description

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Mass Flow Meter (MFM) for Gases

Application Note Operating Principle and Construction of Zirconium Dioxide Oxygen Sensors

Best Practice Guide, Servomex 2700

Determination of Dissolved Gases in Ground Waters. By Ray Martrano Laboratory Director Seewald Laboratories Inc.

Pressure measurement. Pressure gauges

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Installation and Operation Manual

This test shall be carried out on all vehicles equipped with open type traction batteries.

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Example: 25 C = ( ) K = 298 K. Pressure Symbol: p Units: force per area 1Pa (Pascal) = 1 N/m 2

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Columbus Instruments

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

MD61 Thermal Conductor Gas Sensor

Instruction and Maintenance Manual

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

Thermal Conductivity Gauge

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

NOTES: Behavior of Gases

FTC130 Transmitter. Operating Manual

Differential Pressure Transmiter

SAMPLE RH = P 1. where. P 1 = the partial pressure of the water vapor at the dew point temperature of the mixture of dry air and water vapor

How to specify a product. Process Sensors and Mechanical Instruments

Digital Mass Flow Meters and Controllers for Gases

JUMO dtrans p30 Pressure Transmitter

Pressure Transmitters 36 F-27839

Precision level sensing with low-pressure module MS

Electronic gas volume corrector model DGVC-04

Dissolved Oxygen Guide

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

PROPERTIES OF GASES. [MH5; Ch 5, (only)]

Pressure transmitter PASCAL Ci4

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

Specifications of Oxygen Sensor Module V-8344A

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Mass Flow Controller (MFC) for Gases

Digital dead-weight tester Model CPD8500

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

SPD310/SPD360 Air Differential

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

HTD series digital differential pressure sensors

Oxygen Flue Gas Analyzer BA 2000

Datasheet: K-30 ASCII Sensor

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Selecting the right pressure sensor for your application

86BSD Backside Digital Output

Worksheet 12 - Partial Pressures and the Kinetic Molecular Theory of Gases

Transcription:

Using oxygen sensors made by SENSORE, oxygen can be measured in gaseous media within a concentration range from 10 ppm O 2 up to 96 % O 2 depending on the sensor type. The sensor is thus characterized by the following essential characteristics: High accuracy For many types a more or less linear characteristic Small temperature dependence of the sensor signal Low interference with other gases Long service life In many cases Single point calibration necessary only once Technical data see in the appendix (specification). Definition of types Example SO-B0-250-A100C Customized type completion Measuring range of the sensor (see spreadsheet measuring ranges in the appendix) Housing type (see spreadsheet housing types in the appendix) Sign for oxygen sensors Sensor's function If a voltage is applied to the sensor then this sensor operates as a current source, whose output current is dependent on the oxygen concentration of the measuring gas. For this the current is at a certain oxygen concentration dependent on the measuring range selected and on the sensor's production tolerances. Due to these production tolerances each sensor must be calibrated individually! The required, type-dependent sensor voltages and output current ranges are listed in the Sensor type table in the appendix. For all sensor types and for all calibration gas concentrations the following formula is valid: I s [ O 2] ([ O2 ]) ln 1 100 I ([ O ]) s 2 Sensor current in the measuring medium [ O ] 2 Oxygen concentration in the measuring medium in % Sensor-specific constant To determine the sensor-specific constant the sensor must be put in a gaseous medium with a nown oxygen concentration (calibration). With the sensor current measured in this gas and the following formula the constant can be calculated www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 1 / 9

I ([ O2 ]) [ O2, ] ln 1 100 Sensor-specific constant I [ O ] 2 Sensor current at a given oxygen concentration [ 2, O ] Given oxygen concentration (calibration gas concentration) in % For sensor types SO-xx-250 and SO-xx-960 which can be calibrated in air, the sensor current follows as a function of the oxygen concentration the equation: I s Is(20.9%) [ O ] ln1 2 ([ O2 ]) 0.2345 100 I [ O ] s 2 Sensor current at a given concentration I s (20.9%) Sensor current measured in air [20.9 %] [ O ] 2 Oxygen concentration in % For small oxygen concentrations the formula can be simplified mathematically and a linear connection results: I1([ O2 ]) [ O2 ] in which can be determined under the same conditions as described above: I ([ O2 ]) [ O ] 2, I ([ O ]) 2 Sensor current in the measuring medium [ O ] 2 Oxygen concentration in the measuring medium in % Sensor-specific constant I [ O ] 2 Sensor current at a given oxygen concentration [ 2, O ] Given oxygen concentration (calibration gas concentration) in % The sensor output current can be measured either by using a commercial ammeter or it can be converted into an easily measurable voltage with the help of an operational amplifier circuit. The appendix contains a circuit suggestion for this. Sensor heater operating modes In order to operate the sensor it is necessary to heat it. This is carried out using the sensor heater integrated in the sensor. There are two different modes. Constant heater voltage If the ambient temperature fluctuations are small (a few degrees C), then the heating can be operated by means of a constant voltage with current limitation. The necessary heater voltage depends on the sensor housing and is listed with recommended heater current limitation in the appendix. In this heater operation mode the output signal changes by 0.034 % / C ambient temperature. The appendix also contains a circuit suggestion for this. www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 2 / 9

Constant heater resistance However, if higher variations in temperature (e.g. exhaust gas measurement) or also higher gas flow rates occur, then the sensor temperature must be ept constant to increase the measuring accuracy. To eep the sensor temperature constant a rheostatic control is used, which always adjusts the sensor heater's resistance and thus the sensor temperature to the same value independent from the ambient temperature. This desired value of the rheostat is calculated as follows starting from the cold resistance of the sensor heater: R f R w, soll (25C ) R w, soll Resistance of the sensor heating in operation R Resistance of the sensor heating at 25 C ( 25 C) f Temperature factor 2.8; in some applications also 2.65 SENSORE offers an electronic circuit (EDAB-M1V2-L) by which the sensor can be operated in the simplest way (see description in the appendix). www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 3 / 9

Pin connection for different sensor types TO39 (Type SO-A0-xxx), TO8 (Type SO-Bx-xxx) 1 H+ (HS+) 2 H- (HS-) 3 Sen+ 4 Sen- (Pin-side view) Sensors with connecting cable for 4-wire operation (SO-Bz-xxx-AxxxC, SO-Dz-xxx-AxxxC) Sensors with connecting leads (teflon isolation with temperature stability up to 250 C): Cable colour Pin Connection Connected to pin No. Violet 1 H+ Violet 2 HS+ 1 White 1 H- White 2 HS 2 Red Sen+ 3 Blac Sen- 4 Schematic drawing of sensor connection cable with plug, view from bacside of the plug Basic circuit of the sensor There are additional leads named sense drawn in the basic circuit shown beside. With this leads the exact heater voltage at the sensor pins can be adjusted. This four wire measuring system is recommended for heater operation with constant voltage. In case of operation with constant heater resistance mode it is absolutely necessary to use this for wire measurement system. Ih<=Ih max + + Uh - - Sense 1 3 2 4 Is = f(o ) 2 Sensor + Us - Warning Permanent damage to the sensor can occur due to the following circumstances: Sensor is in the unheated state in exhaust gas which contains H 2 S or SO x Contact with water or condensed humidity Contact with gases which contains halogens lie F, Cl, Br Contact with organic vapors www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 4 / 9

Appendix: Operating parameters Sensor heater / Constant heater voltage operation mode Sensor type Housing Heater voltage (*) Suggested current limitation SO-A0-xxx TO39 4.0 volt 0.05 volt 0.5 ampere SO-B0-xxx (except 001) TO8 3.6 volt 0.05 volt 0.5 ampere SO-B0-001-xxxxx TO8 3.8 volt 0,05 volt 0.5 ampere SO-B1-xxx-xxxxx TO8 with mounting flange 3.7 volt 0,05 volt 0.5 ampere SO-D0-xxx- xxxxx Screw mountable housing 4.1 volt 0.05 volt 0.5 ampere SO-D1-xxx- xxxxx Screw mountable housing 4.1 volt 0.05 volt 0.5 ampere SO-D2-xxx- xxxxx Aluminium Screw mountable housing 3.8 volt 0.05 volt 0.5 ampere SO-E1-xxx TO8 with hose connection 3.6 volt 0.05 volt 0.5 ampere SO-E2-xxx- xxxxx TO8 3.6 volt 0.05 volt 0.5 ampere (*) In case of deviate heater voltage the voltage is listed separately Sensor heater / Constant heater resistance operation mode Resistance of sensor heating at 25 C: R( 25 C ) = 3.25 0.20 Sensor type Housing Heater resistance during operation Suggested heating limitation SO-xx-xxx All types R operation = R (25 C)*2.8 0,5 ampere or soft start (PWM) Temperature dependence of the sensor signal 0.034 % measuring signal / C ambient temperature in stagnant air(*) (*) A temperature difference of 200 C (e.g. exhausted gas measuring) means a raise of the sensor signal of 6.8%. Pressure dependence of the sensor signal in the range of 150 mbar 800 mbar in the range of 800 mbar 5.0 bar 2.0 % of measuring signal / 100 mbar 0.5 % of measuring signal / 1 bar Drift of sensor current Neglectable Max. potential difference between heater ground and sensor ground 3 Volt Maring of the sensor Example 412 3412 D Code for measuring range (see spreadsheet measuring ranges in the appendix) Date of production (wee / code for the year) Production order number www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 5 / 9

Pacaging SO-A0-xxx, SO-B0-xxx All other types Plastic case Single or bounded to 10 pieces Mounting SO-A0-xxx, SO-B0-xxx All other types suitable to solder into a PCB; distance to PCB at least 3 mm Mountable in any housing Cross sensitivities Gas Max. concentration of the checed gas Cross sensitivity at oxygen concentration [% O 2 / %Gas] CO 2 40 % -0.027 20 % O 2 CO 2 40 % -0.01 5 % O 2 CO 1000 ppm -0.73 20 % O 2 CO 1000 ppm -0.83 5 % O 2 NO 2 1000 ppm 1.06 SO 2 1000 ppm -0.24 CH 4 1000 ppm -1.77 5 % O 2 H 2 S 400 ppm 0.0 H 2 O (humidity) SO-xx-960 excluded 90% abs 0.0 www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 6 / 9

Relative O 2 Concentration Operation manual Appendix: Change of oxygen content due to humidity Dalton's law (law of partial pressures) The total pressure exerted by the mixture of non-reactive gases is equal to the sum of the partial pressures of individual gases. Mole fraction of gas i in % Partial pressure of gas i Height-dependent barometric pressure (sea level Vienna ~ 160 m ~ 990 mbar) Dry air contains roughly (by volume) 78.084% nitrogen, 20.942% oxygen, 0.934% argon, and small amounts of other gases. Water vapour which is present by an average of 0.4 vol.% (range: 0 4 vol.%), is not included in the above composition, because this amount depends on several environmental conditions. When air is humid, the water vapour associated partial pressure displaces the surrounding air, resulting in a reduction of the relative oxygen content. This water vapour pressure is directly proportional to the temperature-dependent saturated vapour pressure. Water vapour pressure [mbar] Relative humidity in % Temperature-dependent saturated vapour pressure [mbar] Oxygen content of humid in Vol.% Height independent oxygen content of dry air = 20.942 Vol.% Humidity effect in air 21,0% 20,9% 20,8% 20,7% 20,6% 20,5% 20,4% 20,3% 20,2% 20,1% T = 10 C T = 20 C T = 30 C p bar = 990 mbar 20,0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Relative Humidity Attention: The above-mentioned reduction of oxygen content due to moisture is measurable with all Sensore O 2 sensors except for the SO-xx-960 types. Because of a higher sensor voltage (1.6 V) they are able to split water vapour (H 2 O). This additional oxygen causes a positive cross-sensitivity, which leads to an increase of the sensor signal. www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 7 / 9

Is [ua] Is [ua] Is [ua] Is [ua] Operation manual Appendix: Sensor characteristics for different sensor types 350,0 250,0 SO-XX-001 SO-XX-020 300,0 Manufactoring scatter 200,0 Manufactoring scatter 250,0 200,0 150,0 150,0 100,0 100,0 50,0 50,0 0,0 0,00 0,04 0,08 O2 [%] 0,0 0,00 0,20 0,40 0,60 0,80 1,00 1,20 1,40 1,60 1,80 2,00 O2 [%] 250,0 450,0 SO-XX-250 SO-K-DXX-XX-960 400,0 200,0 Manufactoring scatter 350,0 300,0 150,0 250,0 Manufactoring scatter 200,0 100,0 150,0 50,0 100,0 50,0 0,0 0,00 5,00 10,00 15,00 20,00 25,00 O2 [%] 0,0 0,00 10,00 20,00 30,00 40,00 50,00 60,00 70,00 80,00 90,00 100,00 O2 [%] Different sensor characteristics ATTENTION: In each case only one characteristic applies per sensor! Sensor electronics versions from SENSORE SENSORE offers three electronic versions for easy control of the sensor: CSB: Electronic sensor board for oxygen sensors. EDAB-M1: Electronic board with temperature control and linearization of the characteristic sensor curve. GSB: Compact version of EDAB-N1: temperature control and linearization of the characteristic sensor curve. The CSB (Compact sensor board) provides a plugged/soldered sensor with a fixed heater voltage, is compatible to all SENSORE O 2 sensors of the type SO-xx-xxx and has a current or a voltage output. EDAB-M1 contains the temperature control specified in the description and in addition to the signal conversion mentioned also a linearization of the sensor characteristic so that a complicated conversion of the output signal to the measured oxygen concentration is not applicable. The GSB is compared to EDAB-M1 more compact, has a current output and can be reprogrammed according to customer requirements. A more detailed description of the functions is contained in the respective data sheets. www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 8 / 9

Appendix: Simple circuit suggestion www.sensore-electronic.com info@sensore-electronic.com SO001e-7 / 23.04.2015 9 / 9