Installation Instructions. Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect

Similar documents
Installation Instructions. Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect

Type B Gas Vent. Type B gas venting system. UL 441 and ULC S605. DuraFlex AL Aluminum flexible relining. UL 1777 & ULC S635.

Type B Gas Vent. Type B Gas Vent. DuraFlex AL. Type B gas venting system. UL 441 and ULC S605. Aluminum flexible relining UL 1777 & ULC S635.

Model R Type B Gas Vent Large Diameter

Installation Instructions

Installation & Assembly Instructions

Venting Components PolyPro

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Cocoa Patio Pond with Lit Spillway

Intro: by firechim on October 3, 2013

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

Revolution Gurney Attachment

Pro-Form Direct Vent System

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

SERIES BA TRASH BASKETS

Page 1. Single Scull Car Rack Assembly and User s Manual " "

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

G7S Hand Pump Owner s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

ALTERNATOR RACKS 135, 170 & 190 INSTRUCTIONS

Submittal Package. Viega MegaPress Fitting System. Chilled Water. Hydronic Heating. Fire Protection. Low Pressure Steam. Compressed Air (no oil)

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

SERIES BB TRASH BASKETS

RK-IR Sample Draw Aspirator Adapter Operator s Manual

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Operating and Maintenance Instructions

Remington 700. Disclaimer Limited Warranty Satisfaction Guarantee Installation Instructions

ROUND ASSEMBLY. Positioning

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

4-in-1 Professional Inflator Kit

Nitrogen Supply System

Permanent Roof Anchors

BS Series Basket Strainer

USER MANUAL. DM65 Manual Flush/Tilt Combo Mount

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

Owner s Manual Installation and Operation

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

Modular skylight warranty

Yoke Block Instruction Manual

SASK-A-POLE OWNERS AND USERS MANUAL

MANUAL: IN-LINE PIVOT GAUGE IN-LINE GAUGE

SIMPLAIR PIPING TOOL. JXT Company

CF-SERIES HIGH FLOW REGULATORS

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

Owner s Manual & Safety Instructions

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Please Do Not Return This Product To The Store!

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

Prestan professional Training manikin

Yoke Block Instruction Manual

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

INSTRUCTIONS PARTS LIST

Owner s Manual Tourmaster Storage Cart

Vessel Installation and Operating Manual

TWO KAYAK VERTICAL FOLD-DOWN CARRIER

Declaration of Performance (DOP)

ROBERT H. PETERSON CO.

SIZING AND CAPACITIES OF GAS PIPING

Rescue Ladder Basic Kit Model: LDR-BAS-CTS 18ft (5.48m)

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

Angled Sign Light with Shade

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

IMPACT RING BIT SYSTEM Care & Maintenance Instructions

Your safety and the safety of others are very important.

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

MANUAL: Jumbo Siamese and Jumbo Wye

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

MALONER. Installation & Loading Instructions - Please Read Before Beginning. Step 1: Attaching Blocks to Kayak MPG152

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

2000 lb manual winch

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

Heavy-Duty Hot Knife

Bimini Top, Bimini Top Plus for Jeep Wrangler Vehicles Items # , # and #

E X R A D I N. Parallel Plate Ion Chambers User Manual DOC #

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

AIR HYDRAULIC RIVETER

SIZING AND CAPACITIES OF GAS PIPING

Quadratec Delrin Door Hinge Pin Bushings for Jeep Wrangler YJ & TJ 94-06

Warranty. The VELUX promise. Specific limited product warranty 10-year No Leak installation warranty Warranty claim procedure

Gateway. Parts Book Four Panel, Single & Double Adjustment Frames C-1105 SIEVE & CHAFFER SYSTEM. U.S. PATENT No AND FOREIGN PATENTS PENDING

Installation and Operating Manual

Check with local zoning official for property line distance requirements.

RG2200 BC Integrated Octopus

InstallatIon and owner s InstrUCtIons

Model ASSEMBLY and OPERATING INSTRUCTIONS

Standard Collection Setup Manual

92831 TEL: (714) FAX:

Transcription:

Installation Instructions Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect

A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT DURACONNECT BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS. IMPORTANT: Read through all of these instructions before beginning your installation. Failure to install this product as described in these instructions will void the manufacturer s warranty, may create a fire or other safety hazard, and may affect your homeowner s insurance and safety listing of your appliance. Keep these instructions for future reference. Dear Customer, Installer, or End User: We welcome any comments regarding matters pertaining to our DuraVent products. We welcome any ideas, input or complaints and I ll make sure that someone responds directly back to you. Send your emails to: customerservice@duravent.com If you are searching for tech support or product information, please call us at 800-835-4429. Or email us at: techsupport@duravent.com LISTED MH14089

DURACONNECT I AND DURACONNECT II For the most up-to-date installation instructions, see www.duravent.com CONTENTS Introduction, Applications......................................... 4 Connector pipe, Clearances, Fittings................................... 5 Installation Procedure............................................ 6 Technical Report, National Code.................................. 8 DuraConnect II Addendum......................................... 9 DuraConnect 3

It is important that vents and vent connectors be installed only in accordance with DuraVent installation instructions. A major cause of fire related problems with vents and vent connectors is the failure to install with required clearances (air spaces) to combustible materials. Read through all of these instructions before beginning your installation. Failure to install the connector as described in these instructions will void the manufacturers warranty and may have an effect on your homeowners insurance and UL listing. INTRODUCTION DuraConnect & DuraConnect II are flexible aluminum connector systems, with built-in twist-lock fittings for fast, easy professional installations. No more cutting, crimping, fitting, or fastening with screws. Adjustable in length, simply twist-lock, bend, and connect for an 80% labor savings! As safe as it is easy to install, DuraConnect is the first and ONLY single wall connector tested and listed by Underwriter's Laboratories. DuraConnect & DuraConnect II are UL listed for 1 inch clearance to combustibles, and are flexible enough to insure greater earthquake safety. DuraConnect & DuraConnect II are engineered venting systems, developed using the Battelle Laboratories Vent II Computer Program, plus extensive laboratory and field testing. The inside diameter of DuraConnect corrugated flex system has been oversized 1/4 inch to equalize flow resistance to that of smooth wall pipe. By eliminating the use of elbows, DuraConnect & DuraConnect 4 II systems further reduce flow resistance. Due to the high thermal conductivity of aluminum, DuraConnect & DuraConnect II systems heat up rapidly. This reduces condensate "wet time" by up to 50% - a significant factor in vent corrosion. DuraConnect & DuraConnect II are designed to combat condensate corrosion, a common problem with galvanized steel connectors. DuraConnect (single wall) and DuraConnect II (double wall) are constructed of aluminum flex - providing the same metallurgical protection and proven performance as the inner liner material in Type B Gas Vent. APPLICATIONS The DuraConnect & DuraConnect II flexible connector systems may be used as a connector between the gas appliance outlet and a double-wall Type B gas vent or masonry chimney. DuraConnect & DuraConnect II flexible connectors may be used with both draft hood equipped appliances and fan-assisted Category I appliances. Gas appliances may be connected as a single appliance, or in multiples, provided the connectors and the vents are properly sized. DuraConnect & DuraConnect II systems may be installed in conditioned and unconditioned spaces. Refer to National Fuel Gas Code for restrictions on location and operation of equipment and vents. DuraConnect & DuraConnect II systems can not be installed in attic spaces. DuraConnect & DuraConnect II systems may not be used to pass through walls, ceilings, floors, or other combustible materials.

CONNECTOR PIPE DuraConnect & DuraConnect II flexible systems should be installed in as short and straight a run as possible. In accordance with NFPA 211, the appliance should be located as close as possible to the vent or chimney. DuraConnect & DuraConnect II should be installed without any dips or sags, shall have no bends greater than 90 degrees, and shall slope upwards at least 1/4" per foot. Joints between sections of connector pipe, as well as joints between pipe and fittings need not be fastened with screws, and can be connected by the DuraConnect & DuraConnect II twist-lock system. The vent connector shall be firmly attached to the draft hood outlets or flue collars by sheet metal screws or other approved means. The flexible connector may be directly attached to the appliance, or you may use the DuraConnect appliance connector. The DuraConnect & DuraConnect II flexible sections are adjustable in length, providing up to 4 inches per foot of compression. (Zero stretch). Do not cut the flexible pipe. Compress the flexible pipe by setting the female end on the floor, grabbing the pipe approximately 12 inches from the female end, and pressing down, compressing the pipe to the desired length. Warning: do not substitute light gauge aluminum flex such as dryer vent, air duct, or chimney relining materials. CLEARANCES The DuraConnect & DuraConnect II systems are UL listed as flexible connectors with clearances of 1 inch to combustible materials. The DuraConnect & DuraConnect II systems may be installed at a minimum of 1 inch clearance to both walls and ceilings. DuraConnect & DuraConnect II systems are approved for installations located in small furnace rooms, "closets", as well as in open areas such as garages. Due to the high rigidity and natural "spring back" qualities of the DuraConnect & DuraConnect II systems heavy duty flex, no spacers or wall supports are normally required providing the connector is installed at a minimum of 1 inch clearance to combustibles. However, it is important to check the final installation to determine if a reasonable force could deflect the connector to a fixed position less than 1/4 inch from nearby combustibles such as walls, rafters, or framing. If so, DuraConnect wall supports should be installed so as to prevent this close clearance condition. FITTINGS For retro-fit applications, a new appliance may be connected to an existing brand of gas vent previously installed in the wall or ceiling, by use of a DuraConnect adapter or a B-vent adapter for DuraConnect II. These adapters convert competitive brands of gas vent to the DuraConnect & DuraConnect II twist-lock connection. The Type B gas vent chimney may be installed with a DuraConnect round support, or as a low-cost alternative, with a wall strap. When using a wall strap, most Building Codes require installation 5

of a firestop plate at the ceiling. For multiple gas installations, such as a furnace and hot water heater, a wide selection of "Tees" and "Y's" are available in single wall or double wall (B-vent). Note: Providing the "TEE" or "Y" connectors are attached to the Type B gas vent in it's fully twist-lock position, no screws are required for fastening. However, if the branch on the "TEE" or "Y" is angled in some desired direction, and as a result the fitting is not in it's fully twist-locked position, the fitting should be fastened with one or more sheet metal screws. INSTALLATION PROCEDURE Step 1. Secure Type B gas vent such that it protrudes a minimum of 1 inch into the room from a combustible ceiling or wall. Use a DuraConnect round ceiling support or wall straps. Step 2. For a single appliance, simply twist-lock the flex pipe directly into the Type B gas vent. As an alternative, the flex pipe may be attached to the branch of a "Tee", with the tee cap installed in the base of the tee. Step 3. For common venting multiple appliances, twist-lock a double wall or single wall "TEE" or "Y" to the Type B gas vent, then simply twist-lock the flexible connectors into the TEE or Y fitting. Step 4. Bend the flexible connector into position. Avoid dips or sags, and maintain a minimum 1/4 inch per foot rise. When possible, use gradual "sweep" type bends for optimum draft and flow performance. Step 5. Attach the flexible pipe to the outlet of the applianceby using a Draft Hood Connector for DuraConnect II 6 SDV SUPPORT 2 FURNACE ROOM, GARAGE WATER HEATER FLEX CONNECTOR 4 5 3 1" 4 5 3 2 FURNACE WATER HEATER B-VENT Figure 1 Figure 2 1 CEILING 1" WALL B-VENT B-VENT FURNACE

1 B-VENT 4" & 5" OVAL GAS VENT WALL STRAP 1" FIRESTOP CEILING 1" COVER PLATE CEILING FIRESTOP 1 4 3 2A 1" 5 3 4 2B 1" CONNECTS TO WATER HEATER OR FURNACE Figure 5 OVAL TEE BASE PLATE SUPPORT 2 X 4 WALL NOTE: 6" OVAL IN 2X6 WALL FURNACE OR WATER HEATER Figure 3 5 B-VENT 1 GRASP AND PUSH DOWN AT THIS POINT GRASP AND PUSH DOWN AT THIS POINT WALL STRAP APPROX 12" FLOOR FIRESTOP 2 B Figure 6 SINGLE WALL OR DOUBLE WALL TEE TEE CAP 3 4 FURNACE OR WATER HEATER Figure 4 5 7

and an Appliance Connector for DuraConnect. Secure with sheet metal screws. TECHNICAL REPORT UL listing: DuraConnect is the first and only single wall vent connector for gas appliances that has been tested and listed by Underwriters Laboratories. The DuraConnect & DuraConnect II flexible connector pipe and fittings are tested and listed under the UL category of "Chimney and Vent Connectors and Accessories." (UL File # MH14089). UL mechanical test requirements include: 1. Torsional load testing. 2. Ceiling support and wall support load test. 3. Load testing of fitting attachment of flexible connectors. 4. Load testing of aluminum flexible connectors. 5. Flexibility and cross-sectional area tests on flexible connectors. 6. Puncture tests. UL temperature test requirements include: 1. Test Procedure: The flue gas generator shall be fired per UL test procedure #441 (470 degrees F). The tests are to be continued until equilibrium temperatures are reached on nearby combustible materials. (four hours). 2. Test Configurations: The vent connector system is tested in both a horizontal configuration (one inch clearance to walls and ceiling), and a vertical configuration (corner test at one inch clearance to both walls). To simulate a close clearance condition, the vent 8 connector was positioned at several locations 1/4 inch from combustible walls and ceilings for the duration of the tests. 3. Test Requirements: Temperature rise on combustible materials may not exceed UL specified limits. NATIONAL CODES DuraConnect meets all requirements for single wall pipe connectors of the National Fuel Gas Code, ANSI Z223.1, and as specified under NFPA 54, section 7.7, "Single Wall Metal Pipe", and is in compliance with minimum wall thickness requirements for single wall aluminum vent connectors, section 7.10.2b. DuraConnect & DuraConnect II meet the requirements of NFPA 211 as specified under Chapter 5 "Chimney and Vent Connectors", Section 5-2.1. DuraConnect also meets the requirements for single wall vent connectors, of the Uniform Mechanical Code. UL test procedures verify that DuraConnect & DuraConnect II materials, (which are identical to the liner thickness of Type B Gas Vent) are "capable of withstanding the flue gas temperatures produced by the appliance." (Section C.) DuraConnect & DuraConnect II are UL listed at 1 inch clearance to combustible materials and are in compliance with the intent of the Uniform Mechanical Code to limit the temperature rise in nearby combustibles as per UL Standard #441. DuraConnect & DuraConnect II meet the requirements and intent of the National, Standard, and Uniform Mechanical Codes. The DuraConnect flexible connector system has been approved by SBCCI, BOCA and ICBO.

SBCCI Compliance Report 9135 ICBO Evaluation Report 4895 BOCA Research Report 90-82 Patent 5,165,732 National, Standard, and Uniform Mechanical Codes. The DuraConnect flexible connector system has been approved by SBCCI, BOCA and ICBO. ADDENDUM This is an addendum to the DuraConnect & DuraConnect II Installation Instructions. Please read the full Installation Instructions for DuraConnect & DuraConnect II in this document, as well as the Installation Instructions for DuraVent Gas Vent systems (L204) in addition to this document. Where the full Installation Instructions for DuraConnect II and this addendum differ, this addendum takes precedence. WARNING: It is important that vents and vent connectors be installed in accordance with DuraVent installation nstructions. A major cause of fire related problems with vents and vent connectors is the failure to install with required clearances (air spaces) to combustible materials. Read through all of these instructions before beginning your installation. Failure to install the connector as described in these instructions will void the manufacturers warranty and may affect your homeowner s insurance and UL listing. DuraConnect II has been approved by Underwriters Laboratories for use as a segment of Type B Gas vent system for installation in conditioned and unconditioned Attics and Crawl Spaces, as explained in these instructions. Please note that this applies only to DuraConnect II (double wall flex segment/connector) and NOT to DuraConnect (single wall flex connector). DuraConnect II is considered to have the equivalent thermal properties as B-Vent (double-wall gas vent), and can be used where a B-Vent connector is required. Please refer to the NFPA 54 (National Fuel Gas Code) or the Sizing Handbook available from DuraVent for proper gas vent sizing. The following restrictions apply to installing DuraConnect II as a Gas Vent Segment: - DuraConnect II may NOT be fully enclosed inside a chase. - DuraConnect II may NOT penetrate or pass through any combustible surface (walls, ceilings, floors, orroofs, etc.). Passing through combustible surfaces can only be done with rigid gas vent sections (see L204 for instructions). - Always maintain at least 1 clearance between DuraConnect II and combustible materials. - When installing DuraConnect II as a segment in an Attic space (Fig 7), rigid Type B Gas Vent must penetrate at least 3 up into the Attic before DuraConnect II can be attached. The Type B Gas Vent extending up into the Attic must be secured using either a Firestop Support, or a combination of Firestop Spacer and Wall Strap. Also, there must be a minimum of 3 of rigid Type B Gas Vent extending down below roof joists. The rigid Type B Gas Vent above the segment of DuraConnect II must also be secured 9

using a Gas Vent Support installed under the flashing. As an alternative to using the Gas Vent Support, you can use a Wall Strap if there is a roof joist nearby, or you can field-fabricate a supportplate that will both support the weight and prevent lateral movement of the vent. Do not penetrate the inner liner of the vent. It is important that the rigid sections of Gas Vent are properly secured for a safe installation. Figure 7 -When installing DuraConnect II as a segment in a Crawl Space, rigid Type B Gas Vent must extend a minimum of 3 through any penetration (wall, floor, ceiling, etc). The rigid Type B Gas Vent must also be supported using a Firestop Support, Gas Vent Support or Wall Strap, in order to remove the weight load from the DuraConnect II section. Please refer to the full instructions for DuraConnect II in the front part of this document, and Type B Gas Vent (L204) for the remainder of the installation. 10

RIGID GAS VENT GAS VENT ROOF SUPPORT USED TO SECURE VENT IN PLACE, AND REMOVE WEIGHT FROM FLEX SECTION WALL STRAP USED TO SECURE VENT TO NEARBY JOIST ALTERNATIVE 1 RIGID GAS VENT MUST EXTEND A MINIMUM 3 INCHES BELOW ROOF. DURA -CONNECT II FLEXIBLE GAS VENT SEGMENT RIGID GAS VENT FIELD FABRICATED SUPPORT PLATE TO SUPPORT WEIGHT AND PREVENT VENT FROM MOVING. SECURE PLATE TO NEARBY FRAMING MEMBERS. ALTERNATIVE 2 FIRESTOP SPACER ALTERNATIVE 3 WALL STRAP USED TO SECURE VENT TO NEARBY FRAMING MEMBER Figure 7 11

DURAVENT LIMITED LIFETIME WARRANTY M&G DuraVent, Inc. ( DuraVent ) provides this limited lifetime warranty for all of its products with the exception of Ventinox (lifetime), and PolyPro (ten years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from defects in material or manufacturing, if properly installed, maintained and used. DuraVent products are fully warranted if installed only by a professional installer. This Warranty is transferable from the original homeowner to the buyer of the home. This warranty does not cover normal wear and tear, smoke damage or damage caused by chimney fires, acts of God, or any product that was: (1) purchased other than from an authorized DuraVent dealer, retailer or distributor; (2) modified or altered; (3) improperly serviced, inspected or cleaned; or (4) subject to negligence or any use not in accordance with the installation instructions included with the product as determined by DuraVent. Installation instructions are available online at www.duravent.com under Support/Literature and through our Customer Service Department 800-835-4429 or customerservice@ duravent.com. This limited lifetime warranty applies only to parts manufactured by DuraVent. DuraVent provides the following warranties for its products: One Hundred Percent (100%) MSRP 15 years from the date of purchase, and Fifty Percent (50%) thereafter, except for the following limitations on: all Termination Caps and DuraBlack are warranted at One Hundred Percent (100%) for five years. All warranty obligations of DuraVent shall be limited to repair or replacement of the defective product pursuant to the terms and conditions applicable to each product line. These remedies shall constitute DuraVent s sole obligation and sole remedy under this warranty. This warranty provides no cash surrender value. The terms and conditions of this warranty may not be modified, altered or waived by any action, inaction or representation, whether oral or in writing, except upon the express, written authority of an executive officer of DuraVent. Corn, bio-fuels, driftwood or other wood containing salt, preservative-treated lumber, plastic and household trash or garbage, or wood pellets containing such materials must not be burned in the appliance or fireplace. In case of a chimney fire, the chimney must be inspected and approved by a certified Chimney Sweep before reuse. After each annual inspection, maintenance, and cleaning, the certified Chimney Sweep must fill out and date the appropriate section of the warranty card provided with the chimney liner. LIMITATIONS ON INTERNET SALES: Notwithstanding any other terms or conditions of this Limited Lifetime Warranty, DuraVent provides no warranty for the following specific products if such products are not installed by a qualified professional installer: DuraTech, DuraPlus HTC, DuraChimney II, PelletVent Pro, DirectVent Pro, FasNSeal, FasNSeal W2, FasNSeal Flex, and PolyPro, and DuraVent s relining products including DuraLiner, DuraFlex (SW, Pro, 316, 304), and Ventinox. For purposes of this warranty, a trained professional installer is defined as one of the following: licensed contractors with prior chimney installation experience, CSIA Certified Chimney Sweeps, NFI Certified Specialists, or WETT Certified Professionals. DuraVent must be notified and given the opportunity to inspect defective product prior to replacement under the terms of this limited lifetime warranty. All warranty claims must be submitted with proof of purchase. Labor and installation costs are not covered under this warranty. To obtain warranty service contact: DuraVent Warranty Service, 877 Cotting Ct., Vacaville CA 95688, or call 800-835-4429. WHERE LAWFUL, DURAVENT DISCLAIMS ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL DURAVENT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR SPECIAL DAMAGES OR DIRECT OR INDIRECT LOSS OF ANY KIND, INCLUDING BUT NOT LIMITED TO PROPERTY DAMAGE AND PERSONAL INJURY. DURAVENT S ENTIRE LIABILITY IS LIMITED TO THE PURCHASE PRICE OF THIS PRODUCT. SOME STATES DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES, OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE. For the most up-to-date installation instructions, see www. duravent.com REV 3.22.2012 Manufactured in Vacaville CA and Albany NY Customer Service Support: 800-835-4429 707-446-4740 FAX www.duravent.com DuraConnect is a registered trademark of the M&G DuraVent, Inc. All rights reserved. Made in the USA. 2012, 2017 L206_820003158_Install Instructions_Dura Connect_07-14-17_V2