Model of a Standard Operating Procedure (SOP) for BTX measurements with automated pumped sampling and in situ gas chromatography

Similar documents
Model of a Standard Operating Procedure (SOP) for SO 2 measurements with a UV fluorescence analyzer

Standard Operating Procedure

Calibration of a GC955

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

FROG-4000 TM Chemical Analysis System

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Pneumatic high-pressure controller Model CPC7000

FROG-5000TM Chemical Analysis System User s Manual

FROG-4000 TM Chemical Analysis System

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

Pneumatic high-pressure controller Model CPC7000

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Gas Diluter Portable Gas Dilution System User s Manual

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

DPC-30 DPC-100. Reference Manual

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

FTC130 Transmitter. Operating Manual

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

Air Monitoring Directive Chapter 7: Calibration

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Cover Page for Lab Report Group Portion. Head Losses in Pipes

DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes

Instruction Manual Dräger MSI P7 and MSI P7 plus

GCMSD-Headspace Analysis SOP

STANDARD OPERATING PROCEDURES

CORESTA RECOMMENDED METHOD N 6

NGP-250/500 Nitrogen Generator Quick Start Guide

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Automatic Isokinetic Sampler. ST5 Evo

Industrial pressure controller Model CPC4000

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Advanced Test Equipment Rentals ATEC (2832)

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

This test shall be carried out on all vehicles equipped with open type traction batteries.

Environmental Protection Division

628 Differential Pressure Decay Leak Tester

AKTA ION EXCHANGE CHROMATOGRAPHY SOP Date: 2/02/05 Author: A DeGiovanni Edited by: C. Huang Reviewed by:

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

Met One E-BAM Particulate Monitor

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

FPG8601 Force Balanced Piston Gauge

MP15 Jockey Pump Controller

_ pressure transducers. User Manual

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

RK-IR Sample Draw Aspirator Adapter Operator s Manual

PERFORM Operating Document

University of Minnesota Nano Center Standard Operating Procedure

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

PRC CO ² -LASER PRESENTATION

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Simrad GD10P Extended On-site Maintenance

Using the UltraRAE. Firmware 2.35

Cover Page for Lab Report Group Portion. Pump Performance

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

5890II GC Standard Operating Procedure 9/2/2005

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

LUMAZOTE T ECHNICAL BRO CHU RE

NMISA New Gas Flow Calibration Facility

PTG100 Precision Test Gauge

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Installation Procedure Esco Miri Multi-Room Incubator

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Pressure Automated Calibration Equipment

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Technical Bulletin. Seametrics Smart Sensors: Barometric Compensation (with optional DTW setting) Introduction. How Pressure is Measured

Experiment GC : Analysis of BTEX by GC-FID

Additel 780 Series Pressure Controller

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

CSA Sample Draw Aspirator Adapter Operator s Manual

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

HumiSys HF High Flow RH Generator

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

BGA244 Binary Gas Analyzer

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Additel 780 Series Pressure Controller

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Section 1: Overview... 6 Features... 6 Supported Software Part 1: Getting Started 7

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Transcription:

Model of a Standard Operating Procedure (SOP) for BTX measurements with automated pumped sampling and in situ gas chromatography How to use this specimen SOP This model SOP aims at giving support to network operators in setting-up or updating a SOP for BTX monitoring. It gives example text for the necessary points which need to be addressed in a SOP. However, it can only serve as an extended template because a SOP needs to describe the actual circumstances of a network (site locations, exact type of an analyzer, organization and planning of the maintenance procedures etc.). Thus, these items have to be formulated for each monitoring network individually and in a specific way. In particular where concrete figures (e.g. for uncertainties, diameter of connection lines etc.) are given in the example text, these have to be verified and adapted individually for each measurement network. Example text is written in normal style, explanations and directions for needed specific input in italic style. SOP version Give date and number of the current version of the SOP. Responsible person Name of the author of the SOP. Implementation of this SOP version Date of the setting into force of the current version of the SOP and signature of the authorized person. Measurement principle A measured volume of sample air is drawn or forced through a pre-concentration tube. The VOCs are retained by the pre-concentration tube and thus are captured form the flowing air steam. The collected VOCs (on each tube) are desorbed by heating and are transferred by inert carrier gas into precolumn and then to the column for separation. The BTX are quantified using a PID detector (Photo Ionisation Detector). The concentrations of the BTX compounds are measured in units of ppbv. For reporting these are converted to units of μg.m -3 at standard temperature and pressure (20 C, 101,325 kpa) using standard conversion factors. AirMonTech Specimen SOP BTX 1/9

The measurement ranges are 0-50 μg.m -3 for benzene. Measurement results are fully traceable to internationally accepted standards. The expanded measurement uncertainties for benzene, referred to the reference periods of the EU air quality limit values, have been calculated in conformity with EN 14662-3 to be: - 10.6 % for a one-hour period at the 95% confidence level. Users of the SOP Specify here the group of people who will have to work according to the SOP. Equipment - GC analyzer (give type, manufacturer with contact) - Sampling line, sampling pump, calibration system (zero air source, dilution system, flow meters etc.) (give types and short description including manufacturer/provider with contact) - Calibration gas mixture, benzene, toluene, ethyl benzene, orto xylene, meta and para xylene in nitrogen - Carrier gas nitrogen, quality N 5.0. - Station data logger (give type, manufacturer with contact) General remarks: The procedures described are in conformity with the relevant clauses of EN 14662-3 and the manufacturer s recommendations. The BTX monitor produces 15-minute-average measurement results for benzene, toluene, ethyl benzene, p,m-xylene and o-xylene. These results are acquired by the station data processor and digitally transmitted to the central acquisition system located in the Air Quality building. In addition, monitor status parameters listed below are acquired and transmitted. Give here the list of status parameters. Installation Principle: The analyzer is installed at a monitoring station in a way that allows correct operation, i.e. in a shelter protecting the instrument from dust, rain and snow, direct sun radiation, and with an air conditioning providing sufficient temperature stability to fulfill the requirements of the instrument manual. Transport: AirMonTech Specimen SOP BTX 2/9

The analyzer is transferred to the station with attention not to damage internal components. Whenever it is placed in a vehicle care should be taken to protect the instrument from vibrations, direct sun light etc. Initial Check: Check to make sure the instrument arrived undamaged. If you find damage, report it in the LOG-book of the instrument. Analyzers are shipped ready to use. Occasionally, however, rough handling during the transport can cause disconnected cables or electronic boards, or incorrectly positioned switches. Verify that the instrument is in operating condition. A specific procedure for the instrument or some practical hints may be given here. Rack Installation: Select a suitable location for the analyzer with sufficient ventilation and convenient access to the front panel display and connections. The analyzer is supplied with the chassis slides to be mounted in a rack. The instrument requires a properly ventilated rack enclosure in order to avoid operation of the analyzer outside of specifications. The temperature should be in the range of 20 to 30 ºC inside the rack enclosure. After the analyzer has been mounted, make the pneumatic and electrical connections. All pneumatic connections must be tight to ensure accurate operation of the analyzer. Only use lines and fittings made of polytetrafluoroethylene (PTFE), Kynar, borosilicate glass or stainless steel. Caution: Sample and zero air connections to the GC should be maintained at ambient pressure, with any excess flow vented to the atmosphere. The analyzer is connected to the data logger with an RS232 cable. Ensure that the cable is securely connected to the correct COM port of the logger. Exhaust Connections: Connect the exhaust port of the analyzer to the vacuum pump. Connect the exhaust of the pump to an exhaust line. Setting into operation: When the instrument is initially powered up, several components in the instrument are required to reach operating temperature before the analyzer will begin operation. This process typically requires about 60 minutes. Add here a description of the start-up procedure as described in the manual or refer to the manual. After the instrument has warmed up and has advanced from the start up sequence to the measurement mode perform zero and span check to verify the correct calibration of the instrument. Adjust as necessary. AirMonTech Specimen SOP BTX 3/9

Routine maintenance Perform the scheduled maintenance as required by the maintenance schedule. All performed maintenance steps have to be documented in the LOG-book together with date, time and name of the operator. Here the different maintenance activities should be described. They may comprise e.g.: Flow controls, leak tests, cleaning processes, filter and scrubber replacements, check of sensors and status signals. A full list of required maintenance procedures and schedules can always be found in the instrument manual. Calibration Analysers are fully calibrated and tested for linearity. - Upon receipt (new) - Every 3 months - After preventive/corrective maintenance. The calibrations upon receipt and after corrective maintenance are performed in the laboratory. The 3- monthly calibration is performed in the stations. Calculation of results: Monitor results are expressed in units of ppbv. For reporting, these are converted into units of μg.m-3 at standard temperature and pressure (20 C, 101,325 kpa) as follows: Benzene (μg.m -3, STP) = Benzene (ppbv). 3.25 Toluene (μg.m -3, STP) = Toluene (ppbv). 3.83 Ethyl benzene (μg.m -3, STP) = Ethyl benzene (ppbv). 4.41 p/m/o-xylene(μg.m -3, STP) = p/m/o-xylene (ppbv). 4.41 Quality control Zero and span checks: Zero and span checks are performed automatically every 4 days by the dynamic dilution system. An example of a decision scheme associated with the results of the checks is given below. AirMonTech Specimen SOP BTX 4/9

z0=zero directly after installation; z=measured zero; z(-1) previous zero s0=span directly after installation; s=measured span Possible decision criteria for the decision scheme above are e.g.: a=0.2ppbv; b=0.025; c=0.05 Documentation and forms In the appendix examples of a checklist for general controls in the stations (Appendix 1) and for the documentation of the calibrations (Appendix 2) are given. In addition Appendix 3 shows an example for a detailed description of the calibration procedure. All completed forms are stored in the LOG book together with the following information: name of the operator date, time and location model and serial number of analyser and calibrator gas cylinder serial number and cylinder concentration (observe the cylinder expiry date on the cylinder certificate). AirMonTech Specimen SOP BTX 5/9

References EN 14662-3 (2005). Ambient Air Quality - Standard method for the measurement of benzene concentrations - Part 3: Automated pumped sampling with in situ gas chromatography. Revision History In this paragraph the history of revisions of the SOP is documented. It is sufficient to list here the revision dates together with keywords of the revised items. However, all old versions have to be stored at a secure place defined here. Acknowledgement Valuable input was provided by the Air Quality Section of the Department of Labour Inspection of Cyprus and by the Swiss National Monitoring Network NABEL. AirMonTech Specimen SOP BTX 6/9

Appendix 1: Example of a checklist for general controls in the stations: General checks Site: Zurich fulfilled barometric pressure.... 970.2 mbar pump of main sampling line working... yes air conditioning working... yes water from zero air compressor drained.. yes pressure at zero air compressor > 4 bar.. yes temperature in pump compartiment around 20 C... yes inlet filters changed (only NOx and CO ). yes still sufficient filters in stock..... yes VOC-GC: water in H2-generator filled... yes cylinder pressures recorded. yes SO2 cylinder.. NO cylinder. CO cylinder. CH4 cylinder... synthetic air... 69 bar 114 bar 133 bar 138 bar 18 bar Final control All MKAL: Mode = Automatic, Stat = Measure. yes Easycomp: maintenance switched off.... yes PC: backup made, HandyDrive removed from adaptor data acquisition started... climatisation working...... yes yes Remarks: Site possibly influenced by nearby construction work from 3-6 October 2011 AirMonTech Specimen SOP BTX 7/9

Appendix 2: Example of a Calibration protocol Synspec BTX GC955 fulfilled Analyzer working ok (or Alarm: yes yes Date and time noted in Log-Book?. yes yes Calibration: Cylinder: Target 0.64 ± 0.03 ppb benzene values: 0.38 ± 0.10 ppb toluene Span : 0.63 ppb benzene yes 3.61 ppb toluene no End time and cylinder pressure noted in Log-Book?. yes Remarks : AirMonTech Specimen SOP BTX 8/9

Appendix 3: Example for detailed working instructions for calibrations Input provided by the Air Quality Section of the Department of Labour Inspection (DLI) of Cyprus AirMonTech Specimen SOP BTX 9/9

Standard Operating Procedure Air Quality Section Department of Labour Inspection Issue Date: 07/02/2011 DLI-SOP- 261 Calibration, linearity testing of VOCs analysers Rev.: Page #: 1 1 of 5 Prepared by: Date: Reviewed by: Date: Approved by: Date: The coloured ink stamp indicates this is a controlled document. Absence of colour indicates this copy is not controlled and will not receive revision updates. Table of Contents Table of Contents... 1 Purpose... 2 Principle... 2 Staff involved... 2 Equipment... 2 Documentation and forms... 2 Procedure... 2 Finalizing the visit and completing the form... 5 Relevant documentation... 5 Reference Procedures... 5 Revision History... 5 Effective Date: 14/02/2011

Standard Operating Procedure Air Quality Section Department of Labour Inspection Issue Date: 07/02/2011 DLI-SOP- 261 Calibration, linearity testing of VOCs analysers Rev.: Page #: 1 2 of 5 Purpose To describe the procedure to be followed for performing calibrations and linearity tests of the Synspec GC955 analysers. Principle This SOP applies to Synspec GC955 analysers. The procedures described are in conformity with EN 14662-3. Staff involved This SOP is intended for the staff of DLI and the maintenance company who perform the activities described. Equipment Synspec GC955 Sabio 4010 Dynamic Calibrator Certified gas standard of BTEX Station data processor (Ecotech) Documentation and forms For calibration and linearity testing the form DLI-F-1 BTEX Analyser Calibration Report is required. The completed form is stored in electronic form in the file DLI-F-1 BTEX Analyser Calibration Report-sn-yyyy-mm-dd.xls, where sn denotes the analyser serial number, yyyy the year, mm the month and dd the date of the calibration. Paper copies of the forms are stored in the history log book of the analyser. Procedure General Perform the scheduled activities as required by the maintenance schedule (DLI-QD-103). Registration of general information and status parameters Registration of general information: Effective Date: 14/02/2011

Standard Operating Procedure Air Quality Section Department of Labour Inspection Issue Date: 07/02/2011 DLI-SOP- 261 Calibration, linearity testing of VOCs analysers Rev.: Page #: 1 3 of 5 Enter name of customer, analyser model, analyser serial number and job number in Customer, Instrument, ID No. and System/Job No. fields respectively. Enter name of operator, date, time of test and where the test was performed in Calibration Performed by, Date, Time Begin (left field) and Location fields respectively. Registration of reference information (section Calibration Equipment, where applicable): Enter calibrator model, calibrator serial number, zero air generator model and zero air generator serial number in Calibrator Model, ID/Serial No., Zero Air Source Model and ID/Serial No. fields respectively. Enter gas cylinder serial number and cylinder concentration in Gas Std. Cylinder Serial No. and Cylinder concentration fields. Observe the cylinder expiry date on the cylinder certificate and enter it into the Cylinder Expiry Date field. Observe the cylinder pressure (right gauge) and enter the reading including its unit in the Cylinder Pressure field. Remember to read on the Bar scale. Registration of analyser status parameters (section Displayed Instrument Parameters): On the analyser menu select View mode / Actual run. Record the follow parameter Flow Sample pressure Pressure Oven temperature Ambient temperature Preconcentration temperature Compare the recorded values with the acceptance limits. If any values are outside the limits the cause must be investigated. Record if any alarms appear on the screen of the analyser. Check chromatogram base line and peak shape. Single point calibration Calibration check: Make sure that logger and GC955 clock have the same time. Zero check: Start zero point calibration from the logger at hh:00, hh:15, hh:30 or hh45 After 15 minutes in the GC955 will start the analysing the first zero sample. Record the zero for each component. Effective Date: 14/02/2011

Standard Operating Procedure Air Quality Section Department of Labour Inspection Issue Date: 07/02/2011 DLI-SOP- 261 Calibration, linearity testing of VOCs analysers Rev.: Page #: 1 4 of 5 Single point calibration Calibration of GC955 should be done every two weeks Make note of the current file used for the calibration, view mode\calibration curve Start the calibration point from the logger at hh:00, hh:15, hh:30 or hh45 Check if the writing Span gas valve open appear on the screen After 15 minutes in the GC955 will start to analyse of the first span gas sample, skip it. After 31 minutes under option \ set calibration mode. Select Start new calibration Edit the sample concentration for the component that you are going to calibrate and save. After the GC955 ended the cycle, the main screen will be CALIBRATION CURVE. Visualize the chromatogram under view Mode /data file and File / Load data file, chose the path: c/gc955/calibdat/c_yymmdd. Pre calibration Check: under option / edit peak windows adjust the attributes to have the best integration of each component. Wait until one more cycle is ended. Chose View mode/calibration curve and Option/data selection calibration file, Select / Deselect the file that you want to use for calibration. Under Option/Calculate calibration line, calculate the calibration line. Repeat the previous two points for each component. The calibration curves will be active until the next calibration. Chose View mode/program/edit and file/save program file as and save it under the GC955 file with the name ACT_RUN.PRG. Stop calibration: Option/Set calibration mode, stop calibrator. Copy from the directory c:\gc955 to the directory c:\gc955\calidat\c_yymmdd the files AUTOLINDS3.DAT, ACT_RUN.PRG, GC955_id.txt and ActCalib.DAT. To stop the calibration chose options/set calibration mode/normal data mode (no calibration) and press OK. Post-calibration check: Compare the calibration files with the previous one. Autolinearization Make sure that logger and GC955 clock have the same time. Start the calibration point from the logger at hh:00, hh:15, hh:30 or hh:45. After the second cycle, adjust the peak windows on the data file: View mode/data file, file/load data file and option/edit peak windows. Wait until the readings are stable. Effective Date: 14/02/2011

Standard Operating Procedure Air Quality Section Department of Labour Inspection Issue Date: 07/02/2011 DLI-SOP- 261 Calibration, linearity testing of VOCs analysers Rev.: Page #: 1 5 of 5 Start the autolinearisation: from view mode \autolinearisation. Click options and then start autolinearisation, it will take 7 hours. The second order regression is calculated and shown afterwards in the mode autolinearisation. The parameters calculated can be used to improve the linearity of the instrument. Check the binary files in the directory LIN_DATA, if the picks are not well integrated correct them and calculate linearity again. Finalizing the visit and completing the form Enter the end time of the calibration in the Time Begin/End field in the form. Sign the form in the Technicians Signature and Date fields. Before leaving the station record the visit in the station visit log. After returning to the lab store the form in the instrument history log book. Relevant documentation DLI-F-41 Schedule_Yearly Maintenance DLI-F-1 BTEX Analyser Calibration Report. Reference Procedures Synspec GC955 manual Sabio 4010 Dynamic Calibrator manual. Revision History Revision 0 Effective Date: 14/02/2011