The Company With Connections

Similar documents
This document will provide detailed specifications, a bill of materials (BOM), and assembly instructions for the Official Competition Field.

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Permeability. Darcy's Law

Chapter 11. Culverts and Bridges Design Checklist for Culvert Design

NPCA Buoyancy White Paper

NAVIGATOR PROP BUILDING INSTRUCTIONS & PHOTOS

Precision Duct Systems 4570 Commerce Cir SW Atlanta, GA Phone (404)

ROCKSOLID SINGLE POST ANCHOR

Features. Instructions. Your IDEAL Bender has engineered features which include:

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS880 (retrofit kit) 4/275. Overview

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

American Flagpole & Flag Co. 1(800)

Ultrasonic Fuel Level Sensor - UFLS

VACUUM TESTING PRECAST CONCRETE MANHOLES

Item 404 Driving Piling

LifeJacket saves lives when hydraulic pressure fails

6146XX-X OPEN STYLE HOSE REELS

TORO TITAN TINES CATALOG 2013

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

This ramp features levelling feet with angle and length adjustable legs to guarantee a stable and level base.

Firestop Products and Systems Estimating Guide

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

S Surge Arresters

Dean Pump Self-Priming Chemical Process Pumps

Anchorages. Beam Anchors 136 Horizontal Safety Lines 137 Anchorage Lines 138 Rope Grabs 139 Hard Point Anchors 140 Attachment Slings 141

Sediment Basin 7E-12. Design Manual Chapter 7 - Erosion and Sediment Control 7E - Design Information for ESC Measures BENEFITS.

Installation and Maintenance Manual. Dual Medical Gas Outlets

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Miller DuraHoist Safety Systems

// ADapters GUIDelines

Section 7 AMERICAN. Specials

Glass Steel, Inc. Fiberglass Composite Troughs

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

pvc well casing & drop pipe

SPEED SHORE MANUFACTURER S TABULATED DATA "MHS" MODELS. STEEL MANHOLE SHIELDS 4 Single Wall 4 Double Wall 4 Double Wall with Cut-Outs

Flex Series. Series Specifications & Description... Laminate Table Top & Base Chart... Product by Category. Sample Table Layouts... Bases...

BENDING CONDUIT / TUBING USING HAND BENDERS

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Eric Marchand - ericmarchandphotos.com. AccessorIES

River Bridge - Test Shaft-1 Clarke County, MS, 4/2/2012

Float operated valve TYPE (SWDS)

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

PREDL head-office and production-plants

C-Line Electrical Connectors

BRINGING YOU THE SINCE 1980

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

APPENDIX B TESTING PROTOCOLS. Method A: Straight Test Method B: Angular Deflection Test. Method C: Shear Load Test

Build-A-Clock CLOCK CUSTOMIZATION INSTRUCTIONS. One Plan - One Bit, Endless Possibilities. Cut #1. Cut #4 Cut #2. Cut #5 Cut #3

TAZGO DIVISION. Available Services: Shearing, Plate Burning, Saw Cutting, Drilling

TABLE OF CONTENTS. To order tines call us today:

Features. Points to observe during use. SRT SRTB SRT-C Ratchets Pawls. Gears. Spur. Helical. Gears. Internal. Gears. Racks

Single slide rail system Linear shoring

829S1 Series Flexflo Pilot

ZODIAC 601 XL. Position the main spar parallel to the edge of the workbench. Raise the wing skeleton on steel beams or spacers.

Sewer. Contents. Stormwater: Box Culverts. Manhole Bases...2 Access Chambers...3 Make Up Rings...4 Covers...6 Septic...10 Sewer Sundries...

Installation and Maintenance Manual. Compact Medical Gas Outlets

TRAINING LAB BLOOD AS EVIDENCE BLOOD DROPS FALLING AT AN ANGLE NAME

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

LAZY RIVER 3 3 PUMP LOCATION

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

1.5 m. 2.4 m. Fig the pressure exerted by the oil on the base of the tank, the force exerted by the oil on the base of the tank.

Emily Winslow, MD April 1, 2014 SSAT Career Development Grant Update. Summary

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

I N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries

Hynds Manhole System. Technical Guide D4.1

mullen shower base LIFE TIME Suitable for: ALL Floor Types Floor Coverings V Vinyl Wood Flooring Concrete Slab C Ceramic Tiles

MSA Confined Space Entry Equipment

GASKET CUTTER SYSTEMS

2018 MTB Components. Frame Fit Specifications. GEN Rev C 2018 SRAM, LLC

Chapter 9 Accessories for the Kirby Morgan BandMasks

2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

with self-sealing gas valve system

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

CLEANING, INSPECTION, AND TESTING OF SEWERS

Rolled Rotary Ball Screw

TECHNICAL MEMORANDUM 002 EMORANNO. 001

ROCKSOLID DUAL POST ANCHOR

INFACT CORPORATION WATERWORKS PRODUCTS FLEX T-2 SPECIFICATION S TOLL FREE:

HEAVY DUTY H.S. DISCUS CAGE NET POLE NET POLE INSTALLATION

Hydro-Mech Bridge Plug

APT Electrofusion Ducting

Chlorine Supply Containers And Piping

LIFTING MAGNETS ERIEZ MAGNETICS

provides an increased stiffness and strength compared with standard cee studs, resulting in lighter headers which require less labor to install.

MSA Confined Space Entry Equipment

Work Better, Feel Better, Effortlessly. Fellowes Sit-Stand Solutions

Visit: 27

A Low Cost Digital Angle Gage, version 3

SPWE Series. Setup Instructions. Version 2.0

STATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING

Moai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

dumont Minute Man Broaches

CAISSON SHAFT SYSTEM

Thread Gages Tolerances

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

WAVE CYBER HANDLING &

Technical Service Bulletin 10001

Transcription:

SECONDARY INVERT FORMING SYSTEM TRU-CONTOUR The Company With Connections TRU-CONTOUR The Tru-Contour standard system allows for 2/3 invert depth and is compatible with a variety of flexible pipe to manhole connectors. Full depth systems are also available. The Tru-Contour assembly consists of: 1) A hole adapter which is designed to align the invert assembly with the flexible pipe to manhole connector. This insures pipe to invert compatibility. 2) A series of 4 wedges and straight sections which when combined provides an unlimited selection of angles to create enough flexibility to form an in invert within 1.5 degrees. 3) A stabilizing jack which prevents from floatation during casting operations. This insures that correct fall is maintained across the manhole base. AVAILABILITY CHART A-LOK Products, Inc. and Tru-Contour have joined forces to bring together the best in secondary precast inverts available today. The Tru-Contour Invert Forming System offers the manhole producer a very durable, systematic and versatile method of forming all invert configurations from 4" through 48" diameter. KEY ADVANTAGES Two, three, and four way configurations including dead end combinations with a standard.2 ft. of elevation difference (fall) can be made easy and rapidly without the need for skilled labor. Greater fall can be obtained based on the operators' ability to experiment. The system's versatility is due to an unlimited combination of four basic wedges. With the combination of one or more of these wedges, any angle can be obtained within 1.5 degrees. This allows enough flexibility to effectively form an invert which aligns perfectly with the entering pipeline. SIZE (IN/DIA.) 2-WAY 3-WAY 4-WAY 4" 6" 8" 10" 12" 15" 18" 21" 24" 27" 30" 36" 42" 48" System also available in Single Piece construction. The Tru-Contour system cuts costly labor both in set-up and concrete finishing time. A basic three way can be set up in approximately fifteen minutes and depending on pouring procedures, can allow an average of four inverts per day to be formed from a single system. Finishing time is kept to a minimum due to the accuracy of flows the forms create. Each invert in regard to channel width, depth and radial turn is form finished. Patent #4,484,724

INSTALLATION INSTRUCTIONS #1 ASSEMBLY STARTS WITH CENTERING TRIANGLE IN LOW HOLE #4 POSITION ANTI FLOTATION BAR AND ADDITIONAL CHANNEL #2 ASSEMBLE SMALLEST ANGLE WITH CENTERING ADAPTOR #5 POSITION HUBS #3 SMALLEST ANGLE ASSEMBLE IN LOW HOLE AND UPSTREAM SIDE. #6 COMPLETED THREE-WAY ASSEMBLY READY TO POUR ANY QUESTIONS REGARDING TRU-CONTOUR INSTALLATION, PLEASE CALL 1-800-822-2565 A LOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com 800-822-2565 215-547-3366 215-547-5260 FAX

TRU-CONTOUR PARTS GALLERY STRAIGHTS TC-ST-L WEDGES TC-W-22 TC-W-11 TC-W-45 CENTERING TRIANGLE A-LOK PIPE CORE HUB TC-W-06 TC-ST-M TC-CT-A TC-PCH TC-ST-S ANGLES LEFT CENTERING PIN TC-CP RIGHT RING HUB TROWEL TC-TF TC-RA TC-LA TC-RH TC-CJ MANHOLE JACK COMPLETE TC-MJC TC-C CENTERING PIN TOOL ANTI-FLOATATION DEVICE TC-MJB TC-CPT TC-AD STABILIZATION JACK BOOT TC-SJ-B CENTERING TRIANGLE BOOT TRANSITION DROP TRANSITION CENTERING ADAPTOR HOLE ADAPTOR TC-CT-B TC-TP TC-DT SADDLE SHIM PROTRACTOR TC-PRO TC-CA TC-HA STABILIZATION JACK A-LOK TC-HA To order any of the above parts please call A-LOK Products the distributor of Tru-Contour Seconday Invert Systems. Please refer to name or code letters. Call 800-822-2565. TC-SJ-A HOLE ADAPTOR 2004 A LOK Products, Inc. Supercedes all previous literature A LOK PRODUCTS INCORPORATED P.O. BOX 1647, 697 MAIN STREET TULLYTOWN, PA 19007 215-547-3366 215-547-5260 FAX Web- www.a-lok.com E-mail- info@a-lok.com

General Information Tru-Contour Secondary Invert Forming System Guide to Convert 48" Systems to a Larger System System Size 4"-18" 4"-18" 21"-24" 27"-48" Type 2 way 4 way 2 way 2 way To Fit 48" MH (2) 6" Straight (4) 6" Straight No parts needed Yes To Fit 60" MH (2) 6" Straight (4) 6" Straight No Parts Needed Yes To Fit 72" MH (2) 12" Straight (4) 12" Straight (2) 6" Short Straight (2) 6" Short Straight Extra Parts Needed to convert a 2 way into a 3 way This is only applicable with systems 4" to 12" with 3/4 or full height. (1) Long Straight (1) Medium Straight (1) Short Straight (1) 45 Degree Wedge (1) 22 Degree Wedge (1) 11 Degree Wedge (1) 6 Degree Wedge (1) Left Angle (1) Right angle Note: One extra hole adapter or centering triangle will be needed depending on customer preference with hub, per customer choice. Formulas to Create Angles using Tru-Contour Wedges If angle is greater than 180 degrees: Example: 250 Degrees 250-180=70 Example: 210 Degrees 210-180=30 If angle is less than 180 Degrees: Example: 153 Degrees 180-153=27 Example: 135 Degrees 180-135=45 Subtract 180 from higher number. (1) 45 Degree and (1) 22 Degree = 67 (1) 22 Degree and (1) 6 Degree = 28 Subtract from 180. (1) 22 Degree and (1) 6 Degree = 28 (1) 45 degree wedge A LOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com 800-822-2565 215-547-3366 215-547-5260 FAX

General Information Tru-Contour Secondary Invert Forming System Systems are available from 4 to 48 inches. When ordering full height systems, or systems 15 inch and above for boots, half height forms must be ordered (one for each hole). When ordering Tru-Contour accessories for boots, please always give the type of pipe used. In some cases, 3 way and/or 4 way prices are not listed, but available upon request. For diameters 24 inches and above, the anti-flotation device takes the place of the manhole jack. All prices are for 48 inch diameter manholes only. For full height systems add 15% to the base price, including hole adapters and hubs. Custom lenght straight pieces and wedges are available by special order for the price of the next largest standard size. Standard straight lenghts and wedges are as follows: 4 to 12 Diameter Long 20.5 45 Degrees Medium 12 Short 4.25 22 Degrees 15 to 18 Diameter Long 18 Medium 9 11 Degrees Short 4.25 21 to 24 Diameter Long 15.5 6 Degrees Medium 9 Short 4 27 and up Diameter No long Medium 10 Short 5 A LOK PRODUCTS INCORPORATED P.O. BOX 1647 697 Main Street Tullytown, PA 19007 www.a-lok.com email: info@a-lok.com 800-822-2565 215-547-3366 215-547-5260 FAX

Invert Elevation Detail Note: See shim chart for correct measurement. Quality Control Steps 1. Identify the pipe wall thickness and run the invert calculation to determine if the QC check will be a positive or negative set-up 2. Check the nose and hole dimensions of the connector to confirm it has been cast in properly with respect to dimensions and orientation 3. Place a level on the concrete invert as shown in the drawing and assure it is level with respect to the centerline of the invert and connector 4. Use a suitable measuring device such as a tape measure or ruler to accurately document the A dimension from the calculation A-LOK Products PO Box 1647 697 Main Street Tullytown PA 19007 800-822-2565 215-547-3366 215-547-5260 Fax www.a-lok.com