Micro Motion Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation

Similar documents
Micro Motion 7812 Fiscal Gas Density Meter

Micro Motion 3098 Gas Specific Gravity Meter

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Drilling Efficiency Utilizing Coriolis Flow Technology

Micro Motion Multiphase Applications

Installation Manual , Rev BB December Micro Motion H-Series Hygienic Coriolis Flow and Density Sensors

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Case Study Results on Natural Gas Custody Transfer Measurement with Coriolis Meters in Saudi Arabia

A review of best practices for Selection, Installation, Operation and Maintenance of Gas meters for Flare Applications used for Managing facility

Installation Manual MMI , Rev AA April Micro Motion TA-Series Flow and Density Meters

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Appendix 10. Conceptual Measurement, Accounting and Reporting Plan

Micro Motion Advanced Phase Measurement

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Online data sheet FLOWSIC30 GAS FLOW METERS

Oil and Gas Custody Transfer

485 Annubar Primary Flow Element Installation Effects

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Pro-V Multivariable Flowmeter

NEW VERSAFLOW CORIOLIS

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

For Multi-Parameter Meters see mvx

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Measurement & Analytics Wet gas monitoring

For Multi-Parameter Meters see mvx

The ERCB Directive 017 Overview

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

Vehicle-mounted meters, pump supplied

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Truck-mounted Mass Flow Metering for LPG Delivery

ULTRASONIC FLOW METER CALIBRATIONS CONSIDERATIONS AND BENIFITS American School of Gas Measurement Technology, September 2007.

MEASUREMENT BEST PRACTICES FORIMPROVEDREFINERY SAFETY, AVAILABILITY & EFFICIENCY

Application Worksheet

deltaflowc deltaflowc Venturi or Probe

Fisher DVI Desuperheater Venturi Inline

BACK PRESSURE / SUSTAINING

SINGLE VALVE WITH LOW-FLOW BYPASS

Coriolis Mass Flow Meter

BACK PRESSURE / SUSTAINING

ULTRASONIC METER FLOW CALIBRATIONS CONSIDERATIONS AND BENIFITS. Joel Clancy

Differential Pressure Transmiter

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Micro Motion 7835 Series Density and Concentration Meters

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Air Eliminators and Combination Air Eliminators Strainers

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

GAS LIFT IN NEW FIELDS

THERMAL MASS FLOW MEASUREMENT FOR GASES

Cover Page for Lab Report Group Portion. Pump Performance

"BS An overview of updates to the previous ( 2009 ) edition. Andrew Wrath & BS7965 Working Group

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Type 4660 High-Low Pressure Pilot

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Design DSA Steam-Atomized Desuperheater

Installation Operation Maintenance

Accurate Measurement Guidelines

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Vortex Meters for Liquids, Gas, and Steam

Smart Water Application Technologies (SWAT)

Non-intrusive Natural Gas Flow Measurement

Design Features. General Description

General Accreditation Guidance. User checks and maintenance of laboratory balances

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Bubble Tube Installations

Improving distillation tower operation

Installation Manual , Rev BC January Micro Motion R-Series Coriolis Flow Sensors

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Micro Motion 2-Wire Time Period Signal (TPS) Gas Density Meter (GDM)

The Discussion of this exercise covers the following points:

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

Calibrating and Monitoring MUSMs in Natural Gas Service

NFOGM temadag

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Special Documentation Proline Promass 500 Coriolis Flowmeter Modbus RS485 Petroleum Application Package

Manual of Petroleum Measurement Standards Chapter 6 Metering Assemblies Section 3A Pipeline and Marine

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Micro Motion Pressure Drop Testing

780S Ultra High Purity Series

Model Series 62 Constant Differential Relay

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

T208VR Series Tank Blanketing Vacuum Regulator

Fisher 4660 High-Low Pressure Pilot

Transcription:

Micro Motion Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation WWW.micromotion.com This document describes the best practices for selecting a Micro Motion flowmeter, which consists of a sensor and transmitter, and setting up the meter for use. The intent is to establish the best choice when considering the performance level requirements and cost of the meter. While Micro Motion offers an array of sensors and transmitters to meet various application requirements, this document considers only those that are typically used for Oil & Gas metering: ELITE, F-Series, and R-Series sensors, and Series 1000, 2000, and 3000 transmitters. For information about other Micro Motion products, contact your local sales representative. Sizing and Selection Properly sizing a Coriolis meter consists of choosing a meter size that optimizes the trade-off between measurement error at minimum flow rate and pressure loss and/or gas velocity at maximum flow rate. At a constant flow rate, pressure, and temperature, the pressure drop and gas velocity are higher through a smaller diameter meter and may give a higher (mass) accuracy measurement and turndown ratio. Likewise, pressure drop and gas velocity are lower when a larger diameter meter is chosen; however, the potential measurement error at a similar low flow rate may increase, and the turndown ratio may decrease. In some gas measurement applications the sensor size could be one or more pipe sizes smaller than the upstream or downstream piping, requiring pipe reducers and expanders. Excessive lengths of small diameter pipe or abrupt flow diameter reductions such as tees, short radius elbows, etc., can adversely affect pressure drop. In cases where a reduction is required, the use of long or gradual transition swedges is suggested. Measurement errors can typically be avoided by: Ensuring the separation system has enough retention time, pressure drop, and applied temperature as required to remove the free gas Limiting the pressure drop across the meter upstream of the level valve to 0.75 to 3 psid or less All of the specifics guiding these two priorities are dependent on the EVP (equilibrium vapor pressure) of the oil to the process operating pressure/temperature and time in residence of the live oil. Instantaneous Rate vs daily Production Rates. Coriolis flow meters should be sized for the instantaneous rate at the meter rather than the production rate of the well for each fluid (water, oil or gas). Note: The information that follows is complex. Contact your local Emerson Flow expert for additional guidance. Pressure Drop vs. Accuracy The minimum flow rate (min Q) is defined by the lowest flow rate at which the meter error will not exceed the uncertainty specified by the Operator. Use the Micro Motion Sizing Tool to find the best fit for the application. Volatile hydrocarbon (live oil) sizing considerations. It is important to minimize pressure drop on live liquid hydrocarbons as any drop in pressure can cause gas to liberate from the oil resulting in measurement error. GI-001774 / 2013 Micro Motion, Inc. All rights reserved.

MICRO MOTION INC. Page 2 of 8 The instantaneous rate across the meter can be determined by carefully completing the following steps: First, by determining the daily production rates for: - Oil - Water - Total liquid (should be equal to Oil + water) - Total gas Second, by production method (natural lift, pump jack, ESP, gas lift, plunger lift, etc.) Third, by gas vs. liquid centric well characteristics (actual, not predicted GOR, GLR) Fourth, C1 through C5 constituent component stream of the live Oil Fifth, Process operating conditions of the separator &/ or treater to the sales system: - Pressure, Temperature - Level control system including the valve type, size, trim, etc. - Downstream pressure of gathering system or sales/ storage tanks Material of Construction All stainless steel Micro Motion meters can be rated to at least 1450 PSI; nickel alloy C22 meters can be rated to at least 2160 PSI. For other pressure requirements, check with the Micro Motion Factory. Pay attention to material compatibility. For most natural gas applications, 316L stainless steel is sufficient; however, consider carefully if corrosive components are present. Use nickel alloy C22 as warranted; consult Micro Motion regarding corrosives concerns. Communication Requirements In applications where a flow computer is used, the choice of RTU/ Flow computer may determine which Micro Motion products are selected. If the RTU has the capability of processing the mass flow rate directly from the MODBUS registers from the sensor core processer, then only Direct Connect is required. If the above is not applicable then a Micro Motion transmitter is required. Verification Requirements If meter performance verification is required and it can be performed from either the MODBUS registers or traditional I/O via the RTU/ Flow computer, then only Direct Connect is required. Additionally, if Micro Motion Smart Meter Verification (SMV) is desired, then the meter must be purchased with a model 800 enhanced core processer. Installation Orientation In general, sensor orientation does not affect measurement performance; however, when possible, meters should be oriented according to the preferred orientations shown in the table below, which are based on the shape of the meters and their flow tubes. If it is not possible to use the preferred orientation, use the alternate orientation.

Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation Page 3 of 8 Type Gases FLOW Preferred Orientation FLOW FLOW MINIMAL LIQUID PRESENCE (ALL MODEL TYPES) Alternate Orientation Bypass May be considered to provide an alternate path for process during meter maintenance and inspection procedures. Consideration should be given prevent inadvertent bypassing of the meter. Use double block and bleed valves to identify bypass leaks caused by a leaking block valve seat. Isolation Block Valves Allow the sensor to be removed from the process conditions. Isolation valves should be located in close proximity to the meter to facilitate accurate zeroing. If incorporated with a pressure blow down port, the isolation block valve integrity can be verified by monitoring the pressure after blow-down. Liquids FLOW FLOW Pressure and Blow-down Port This port can provide for the monitoring of process pressure if required. If correcting for flow pressure effect, the process connection should be located directly upstream of the sensor. FLOW Thermowell Port Provides for use of a flow temperature reference in the verification of the temperature measurement made by the sensor. The thermowell should be installed upstream of the sensor. Sensor Models ELITE Series The ELITE models CMF, CMFS, or CMFHC are the highest performance sensor, with the best sensor-based flow and density accuracy and turndown, and widest selection of sensor sizes. Fiscal Metering Custody Transfer. API Chapter 5 of stabilized (weathered) products, such as pipeline and LACT.

MICRO MOTION INC. Page 4 of 8 Net Oil. The density measurement is used to determine the percent of water and oil in a single flow stream (i.e., twophase separator). Because of their superior density measurement accuracy, ELITE meters should be used when water cuts are above 85% and the gravity is lower than 40 API. F-Series The F-series sensor is a high performance sensor for accurate flow and density measurement, as well as wide turndown capability. Production and/or Allocation. Measurement where high accuracy, turndown, or performance verification is required. Net Oil. F-series sensors can be used when water cuts are below 85% and the gravity is higher than 40 API. R-Series The R-Series is the Micro Motion general purpose sensor. Allocation. Used for measurements where mechanical or differential pressure meter accuracy and turndown performance are inadequate. Coriolis meters deliver accuracy and turndown benefits plus low maintenance and diagnostics. Transmitter Models All Micro Motion sensors with integral core processors are capable of direct MODBUS communication. In applications where only direct MODBUS communication is desired, a transmitter may not be required. If this option is chosen, then a model 500 Micro Motion barrier is recommended. If the above is not applicable then a Micro Motion transmitter is required. All Micro Motion transmitters have the same basic performance specifications. Selection criteria should be based on features required by the application. Transmitters are required for any flow meter which is proven in order to produce a pulse output. Transmitter NOC Weights & Measures API Analog/Pulse/ HART Modbus Multi-variable 3000 X X X X X X 2500/2700 X X X X X Direct Connect X X X 1500/1700 X X Series 3000 The Series 3000 transmitter/controller has the largest feature set. Net Oil. The series 3000 is used when Net Oil calculations are required. For field mounting, use model 3700. For panel mounting, use model 3500. Series 2000 The Series 2000 transmitters measure multiple variables simultaneously, and they have additional output and digital communication options. Best Fit. High performance multivariable transmitter. The model 2500 is a DIN rail mount transmitter. The model 2700 is a field mount transmitter with the following features: Two-inch pipe mount or integral mount Integral backlit configurable display Hazardous area approval options Series 1000 The Series 1000 transmitters output flow only via analog or frequency, and they also have digital communication options.

Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation Page 5 of 8 Best Fit. Alternative to 2000 Series if only flow output is required. Used with R-Series meter applications. The model 1500 is a DIN rail mount transmitter. The model 1700 is a field mount transmitter with the following features: Two-inch pipe mount or integral mount Integral backlit configurable display Hazardous area approval options To determine the optimal transmitter selection, refer to the Transmitter Decision Tree, below. Transmitter Decision Tree Is NOC Being Used? Yes Use Series 3000 No Features Petroleum Software Weights & Measures Future Features (e.g., Proving) Density on Analog Config I/O Required Need Modbus Only? No Need any features? No Use Series 1000 Yes Yes Use Direct Connect Use Series 2000 Setup Base Configuration Sensors data is in the core. Flow Calibration Factor and Density K factors from the sensor tag are stored in the Core processor. They should always be verified upon start up or after repair. Mass and volume flow cutoff. Mass and Volume Flow Cutoff specify the lowest Mass and/or Volume flow rate that will be reported as measured flow. All flow rates below this cutoff will be reported as zero flow. The appropriate cutoff value must be determined by the end-user as the 'Live Zero' can be influenced by sensor installation, orientation, sudden process temperature changes, and presence of entrained gas in a liquid stream or presence of liquid in a gas stream. Suggested cutoff values range from 0.2% to 0.5% of the maximum flow rate expected through the sensor but may be higher depending on the influences described above. Note: Low Flow Cutoff values higher than 0.5% of the maximum flow rate may indicate a process or installation issue that should be investigated For gas measurement, many users choose to set low flow cut off based on minimum acceptable accuracy: Mass or Volume Flow Cut off = Published Sensor Zero Stability / Minimum Acceptable Accuracy At Pressure Base of 14.73 PSIG, Temperature Base = 60 F, with SG = 0.6, then Gas Density is 45.92 lb/mcf. Example: A model CMF300 has a stated zero stability of 15 lb/hr. If the customer-specified minimum acceptable accuracy is 1%, the mass flow cutoff would be: 15 lb per hour/ 0.01 = 1,500 lb/hr. Note: for gas applications, Density Cut Off should be set to 0.0. Special units. Special Unit are sometimes desired and required to interface with different RTUs. A Tab in ProLink software is used to convert base units to desired unit. For example SCF to MSCF (Thousand Cubic Feet) or lb to Mlb (Thousand pounds).

MICRO MOTION INC. Page 6 of 8 Frequency output. For liquid applications, frequency output provides maximum resolution by setting 10,000 Hz equal to the maximum flow rate. For gas applications, frequency output for gas measurement should be set for maximum resolution related to mass flow. For example, with gas density of 45.92 lb/mcf and a maximum flow rate of 1MMSFD: 1,000 MSCF X 45.92 lb/mscf = 45,920 lb Frequency Output should be set to 10,000 Hz = 45,920 lb - 10,000 pulses/sec X 86,400 sec / 45,920 lb = which is 18,815 pulses/lb - 18,815 becomes the K Factor in the RTU Pressure compensation. Pressure compensation may be used in MMI transmitter or RTU but should not be used in both. The calibration pressure is found on the sensor calibration certificate. Pressure compensation is based on operating pressure minus calibration pressure. Meter Verification and Flow Performance Testing The frequency is at the discretion of the operator. Field Meter Verification of Micro Motion metering system consists of monitoring and evaluating operating conditions and diagnostic indicators to identify possible change in the system performance, as well as the cause. By evaluating the Meter diagnostics the operator can determine if the meter needs to be re-zeroed, if a flow performance test (insitu or laboratory) needs to be initiated, or if the scheduled maintenance frequency needs to be modified. Field Meter Verification. The field verification of the Micro Motion meter involves evaluating and monitoring, metering conditions and meter diagnostics to identify changes in meter performance and their causes. The evaluation of these diagnostics will determine the need to re-zero the Coriolis meter, perform a flow performance test (in-situ or laboratory), or adjust periodic maintenance. Meter/Transmitter Verification - The meter transmitter verification should coincide with the meter zero check. It should include the following procedures: 1. Verify the sensor calibration and configuration parameters of the transmitter. 2. Use ProLink software to verify and record all transmitter diagnostics. Temperature Verification - The Micro Motion transmitter monitors a temperature element bonded to its flow tubes that corrects for Young's modulus of the flow tubes. Using a temperature reference placed in an upstream thermowell or temporarily placed tightly against the upstream flow splitter/inlet and insulated, verify the temperature indicated by the sensor to be within ±1 F of the reference temperature. Meter Zero Verification - It is recommended by AGA that at minimum, the meter zero be checked at flowing pressure and temperature within 1 to 4 weeks of installation and quarterly during the first year of its field service. The frequency of subsequent zero verifications should be guided by the record of meter zero data, operating conditions, and by operator policy. The meter zero verification should include the following procedures: - Create zero flow condition by blocking meter upstream and downstream. Verify meter zero is within the factory specifications for type and size of meter under evaluation. Zero verification cannot be performed correctly without thermal stability. Especially for gas service, be aware that thermal gradients or temperature changes can cause flow within the piping even though the system is blocked in. - Perform zero check using Prolink software. Alternatively Prolink can be used to log the live zero value for a minimum of three minutes. Saved data should be averaged and compared to the zero stability specification. If within the specification, record the as-found zero and then return to service. - If the zero is not within the specification, record the as-found zero, then rezero, record new zero, and compare to factory specification. If meter zero is within specification, record the as-left meter zero value and return the meter to service. Micro Motion Smart Meter Verification - When equipped with this feature, sensor and transmitter diagnostics can be scheduled at some interval or run on demand.

Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation Page 7 of 8 If meter zero is out of specification check the following: - Verify isolation valves are not leaking and check for other potential leak sources. If leaks are present, zero verification cannot be performed correctly. Correct issues, re-zero the meter, and record the new zero value. - Evaluate indicated density, if it is higher than expected by more than 20% for the gas at the blocked-in conditions the sensor may be contaminated and/or have a coating on the flow tubes (e.g., condensates, glycol, amines, water, oil, dirt, etc.) and should be cleaned. A low density reading can also be caused by erosion or corrosion. In this case the sensor will need to be evaluated by Micro Motion. - Incorrect Mounting can result in an offset or drifting zero, as out-of-square components may cause a bias in the meter zero through change in the dynamic balance of the meter's flow tubes. - To confirm, check the sensor drive gain to insure it is low and stable. If the meter zero has a history of drifting or instability, then one side of the meter should be unbolted completely to relieve any potential stress that my be present. While unbolted, inspect the mating flange set for shifting, pulling apart, or a misalignment. If mounting stress is found, correct the issues and retest the zero. Prolink Datalog Instructions Key diagnostics list Process Variables: Density, Mass Flow Rate, Mass Total Temperature, Volume Rate, Volume Total Diagnostics: Drive Gain, Input Voltage, Left Pickoff Voltage, Live Zero, Right Pickoff Voltage Flow performance testing If flow performance testing is required: For liquid, prove according to industry best practices. For gas: - Remove from service and send to the manufacturer or third party lab. - Perform in-situ flow testing via field proving with gas master meters in accordance with industry best practices and/or regulatory requirements.

Page 8 of 8 Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation A field flow performance test verifies meter performance at field operating conditions. Operating conditions can affect the accuracy and repeatability of a meter. When performance testing in the field, use caution to insure the items below are evaluated to minimize their impact on meter performance. Mechanical stress on the meter Flow variations Extreme variations in fluid pressure and temperature Ambient temperature changes Fluid phase and composition If field flow performance testing is desired, the metering system piping should be designed to incorporate the attachment of a reference meter. Coriolis Meter Example Configuration for Field Performance Testing When utilizing a reference meter for field performance testing, a reference meter (master meter) should be used. It should be calibrated in a laboratory traceable to a recognized national or international measurement standard. In any case, the reference meter should have a measurement uncertainty less than the field meter being tested. Note: When a Meter Under Test (MUT) is tested against a field reference, the MUT should not be adjusted if the performance is found to be within the uncertainty of the field reference. Reference Meter P1 P2 Example configuration for Field Performance Testing WWW.micromotion.com 2013 Micro Motion, Inc. All rights reserved. The Micro Motion and Emerson logos are trademarks and service marks of Emerson Electric Co. Micro Motion, ELITE, MVD, ProLink, MVD Direct Connect, and PlantWeb are marks of one of the Emerson Process Management family of companies. All other trademarks are property of their respective owners. Micro Motion supplies this publication for informational purposes only. While every effort has been made to ensure accuracy, this publication is not intended to make performance claims or process recommendations. Micro Motion does not warrant, guarantee, or assume any legal liability for the accuracy, completeness, timeliness, reliability, or usefulness of any information, product, or process described herein. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. For actual product information and recommendations, please contact your local Micro Motion representative. Micro Motion, Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, CO 80301 T +1 303-527-5200 +1 800-522-6277 F +1 303-530-8459 Micro Motion Europe Emerson Process Management Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 318 495 555 F +31 (0) 318 495 556 Micro Motion Japan Emerson Process Management 1-2-5, Higashi Shinagawa Shinagawa-ku Tokyo 140-0002 Japan T +81 3 5769-6803 F +81 3 5769-6844 Micro Motion Asia Emerson Process Management 1 Pandan Crescent Singapore 128461 Rebuplic of Singapore T +65 6777-8211 F +81 6770-8003